Search PubMed⌕ Search

Biomedical subjects

D J Weber

Publications and source records attributed to D J Weber.

227 records · Page 13Linked to original sources

Encoding mechanisms for sensory neurons studied with a multielectrode array in the cat dorsal root ganglion.

Recent advances in microelectrode array technology now permit a direct examination of the way populations of sensory neurons encode information about a limb's position in space. To address this issue, we recorded nerve impulses from about 100 single units simultaneously in the L6 and L7 dorsal root ganglia (DRG) of the anesthetized cat. Movement sensors, placed near the hip, knee, ankle, and foot, recorded passive movements of the cat's limb while it was moved pseudo-randomly. The firing rate of the neurons was correlated with the position of the limb in various coordinate systems. The firing rates were less correlated to the position of the foot in Cartesian coordinates (x, y) than in joint angular coordinates (hip, knee, ankle), or in polar coordinates. A model was developed in which position and its derivatives are encoded linearly, followed by a nonlinear spike-generating process. Adding the nonlinear portion significantly increased the correlations in all coordinate systems, and the full models were able to accurately predict the firing rates of various types of sensory neurons. The observed residual variability is captured by a simple stochastic model. Our results suggest that compact encoding models for primary afferents recorded at the DRG are well represented in polar coordinates, as has previously been suggested for the cortical and spinal representation of movement. This study illustrates how sensory receptors encode a sense of limb position, and it provides a general framework for modeling sensory encoding by populations of neurons.

Action Potentials↗

Functional electrical stimulation using microstimulators to correct foot drop: a case study.

This paper presents a case study that tested the feasibility and efficacy of using injectable microstimulators (BIONs) in a functional electrical stimulation (FES) device to correct foot drop. Compared with surface stimulation of the common peroneal nerve, stimulation with BIONs provides more selective activation of specific muscles. For example, stimulation of the tibialis anterior (TA) and extensor digitorum longus (EDL) muscles with BIONs produces ankle flexion without excessive inversion or eversion of the foot (i.e., balanced flexion). Efficacy was assessed using a 3-dimensional motion analysis of the ankle and foot trajectories during walking with and without stimulation. Without stimulation, the toe on the affected leg drags across the ground. BION stimulation of the TA muscle and deep peroneal nerve (which innervates TA and EDL) elevates the foot such that the toe clears the ground by 3 cm, which is equivalent to the toe clearance in the less affected leg. The physiological cost index (PCI) measured effort during walking. The PCI equals the change in heart rate (from rest to activity) divided by the walking speed; units are beats per metre. The PCI is high without stimulation (2.29 +/- 0.37, mean +/- SD) and greatly reduced with surface (1.29 +/- 0.10) and BIONic stimulation (1.46 +/- 0.24). Also, walking speed increased from 9.4 +/- 0.4 m/min without stimulation to 19.6 +/- 2.0 m/min with surface and 17.8 +/- 0.7 m/min with BIONic stimulation. These results suggest that FES delivered by a BION is an alternative to surface stimulation and provides selective control of muscle activation.

Adult↗

New disinfection and sterilization methods.

New disinfection methods include a persistent antimicrobial coating that can be applied to inanimate and animate objects (Surfacine), a high-level disinfectant with reduced exposure time (ortho-phthalaldehyde), and an antimicrobial agent that can be applied to animate and inanimate objects (superoxidized water). New sterilization methods include a chemical sterilization process for endoscopes that integrates cleaning (Endoclens), a rapid (4-hour) readout biological indicator for ethylene oxide sterilization (Attest), and a hydrogen peroxide plasma sterilizer that has a shorter cycle time and improved efficacy (Sterrad 50).

Disinfectants↗

Zoonotic infections.

More than 200 diseases are transmitted from animals to humans. Zoonotic infections can be transmitted via animal bites, arthropod vectors, especially ticks and mosquitoes, and direct contact with animals. Infections also can be contracted indirectly by ingestion of contaminated food or water or contact with contaminated hides, wool, or fur. Persons at risk of zoonotic infections include people who enjoy outdoor leisure activities such as hiking, camping, hunting, spelunking, and fishing. Occupational groups at risk include animal control officers, hunters, abattoir workers, farmers, fisherpersons, persons working with hides or wool, and laboratory workers working with zoonotic pathogens. The risk of infection can be reduced by appropriate use of personal protective equipment, immunizations, and measures to avoid insect bites.

Animal Husbandry↗