Search PubMed⌕ Search

Biomedical subjects

D H Sheafor

Publications and source records attributed to D H Sheafor.

26 records · Page 2Linked to original sources

PACS in sonography: accuracy of interpretation using film compared with monitor display. Picture archiving and communication systems.

OBJECTIVE: The goal of this study was to determine the relative accuracy of interpretation of sonography when viewed on a monitor or on film. MATERIALS AND METHODS: Four radiologists twice interpreted a series of 440 sonograms using the following sequences of display formats for initial and second interpretations: film-film, film-monitor, monitor-film, and monitor-monitor. Reporting discrepancies between the initial and subsequent interpretation were reviewed by an arbitration panel unaware of the display mode. Results were analyzed for differences in error rate attributable to film versus monitor display format, chronology of interpretation, individual observer, and observer seniority. RESULTS: We found no statistically significant difference in the error rate for film (10.3%) versus monitor display format (14.6%) (p = .09). Likewise, we found no significant differences in the error rates attributable to chronology of interpretation (p = .13), individual observer (p = .54), or observer seniority (p = .87). CONCLUSION: Interpretative accuracy is similar whether sonograms are interpreted on a monitor or on film.

Artifacts↗

Percutaneous liver biopsy: a cost-benefit analysis comparing sonographic and CT guidance.

OBJECTIVE: We compared the relative cost of a liver biopsy performed with sonographic guidance with that of one performed with CT guidance in a cost-benefit analysis model. MATERIALS AND METHODS: Variables were estimated from a search of the literature and from clinical experience with 437 hepatic biopsies at our institution. Probability variables included the probability of obtaining an adequate sample and the probability of a major complication. Cost variables included the direct and indirect costs, the cost of a major complication, and the opportunity costs of foregone revenue from preempted diagnostic studies. One-way and two-way sensitivity analyses were performed. RESULTS: Using baseline values, CT guidance was 1.89 times more expensive than sonographic guidance. Sensitivity analyses indicate that CT and sonographic guidance costs would be equivalent if the success rate with sonographic guidance was 39.8%, the opportunity costs of CT guidance were 3.13 times less than best estimates, and the opportunity costs of sonography were 3.15 times greater than best estimates. CONCLUSION: Sonographic guidance for hepatic biopsies is substantially more economical than CT guidance across a wide range of estimated costs.

Biopsy, Needle↗

Dynamic helical CT of the abdomen: prospective comparison of pre- and postprandial contrast enhancement.

PURPOSE: To investigate effects of a liquid meal on contrast material enhancement at dynamic helical computed tomography (CT). MATERIALS AND METHODS: Twenty healthy, fasting subjects underwent intravenous injection of nonionic contrast material at 4 mL/sec. Axial CT sections were obtained at a single level 15 seconds after injection, then every 5 seconds for 2 minutes. This protocol was repeated 1 week later, after ingestion of a 360-calorie liquid meal. Hepatic, splenic, and aortic attenuation were measured before and after contrast material administration. Peak enhancement level, time to peak enhancement, slope of hepatic enhancement, and hepatic, splenic, and aortic enhancement ratios were determined. RESULTS: Postprandial time to peak enhancement was 4.4 seconds earlier than preprandial (59.6 seconds +/- 9.0 [1 standard deviation] vs 64.0 seconds +/- 9.5; P < .02). No differences in maximum attenuation were found (P > .27). Postprandial maximum slope of hepatic enhancement and temporal and quantitative enhancement characteristics in aorta and spleen did not significantly differ. Postprandial hepatic-to-splenic enhancement ratios increased (P = .04), and aortic-to-hepatic ratios decreased (P = .01). Aortic-to-splenic ratios did not differ (P = .45). CONCLUSION: A liquid meal before intravenous injection of contrast material produces more rapid peak hepatic enhancement, with slightly increased relative hepatic enhancement. A patient's dietary status, however, should not influence the CT protocol.

Adult↗

Abdominal percutaneous interventional procedures: comparison of CT and US guidance.

PURPOSE: To compare ultrasound (US) with computed tomography (CT) as a guidance modality for percutaneous interventional procedures. MATERIALS AND METHODS: A database of abdominal interventional procedures was reviewed for the 6 months preceding and 6 months after the opening of a dedicated US interventional suite. Changes in the number and type of procedures performed, room time, number of needle passes, and complication rates were calculated. RESULTS: In the first 6 months, 305 interventional procedures (138 tissue biopsies and 167 fluid aspirations) were performed (CT guidance in 87% [n = 120] and 95% [n = 159], respectively). In the 6 months after installation of the suite, 395 procedures (195 tissue biopsies and 200 fluid aspirations) were performed (US guidance in 76% [n = 148] and 34% [n = 67], respectively). The largest increase in US utilization was for guidance of tissue biopsies, rising from 6% (18 of 305) to 37% (148 of 395) of all procedures. Room time was significantly less for US-guided procedures (mean US room time, 77 minutes +/- 33 [1 standard deviation]; mean CT room time, 99 minutes +/- 38; P < .0001). CONCLUSION: US guidance often allows performance of quicker, more accurate procedures than does CT guidance, probably because of its real-time capabilities.

Abdomen↗

Scrotal pathology as the cause for hip pain. Diagnostic findings on bone scintigraphy.

Scrotal scintigraphy has become a relatively uncommon examination in many nuclear medicine departments. However, scrotal perfusion is visualized during three-phase bone imaging of the pelvis and hips. The authors present a compilation of three cases of hip pain secondary to unsuspected scrotal pathology documented on routine three-phase bone scintigraphy, discussing this topic for the first time in the literature. A short review of the pathophysiology of referred hip pain, differential diagnosis, and imaging alternatives emphasize the unique contribution of nuclear imaging.

Adolescent↗

Small lymph nodes of the abdomen, pelvis, and retroperitoneum: usefulness of sonographically guided biopsy.

PURPOSE: To evaluate the usefulness of sonographically guided percutaneous biopsy of small lymph nodes in the abdomen, retroperitoneum, and pelvis. MATERIALS AND METHODS: From May 1995 through January 1997, 35 sonographically guided lymph node biopsies were performed in 34 patients. All biopsies were performed with a 20- (n = 18) or 22-gauge (n = 10) self-aspirating needle alone or in combination (n = 7). To determine the amount of compression achieved with the transducer, the skin-to-lesion distance on reference computed tomographic (CT) scans was compared with that on sonograms. A biopsy was considered successful if a specific benign or malignant diagnosis was rendered by the pathologist. RESULTS: Of 35 sonographically guided biopsies, 30 (86%) were successful. Diagnoses included 26 (74%) cases of carcinoma, three (9%) cases of benign reactive lymphocytosis confirmed at open biopsy, and one (3%) case of a lymph node with a positive acid-fast bacilli stain. The average lymph node diameter was 2.1 cm (range, 0.9-4.3 cm). With sonography, a mean of 2.5 needle passes (range, 1-5) were made per biopsy. Transducer compression reduced the skin-to-lesion distance from an average of 8.8 cm (at CT) to 4.5 cm. CONCLUSION: Sonographic guidance seems to provide a reasonable alternative to CT in biopsy of small abdominal, pelvic and retroperitoneal lymph nodes.

Abdomen↗

Pancreatic malignancy: effect of dual-phase helical CT in tumor detection and vascular opacification.

PURPOSE: To determine the relative value of hepatic arterial and portal venous phase helical computed tomographic (CT) scans for tumor detection and vascular opacification in patients with pancreatic malignancy. MATERIALS AND METHODS: Ninety-five patients who had or were suspected of having pancreatic disease underwent dual-phase helical CT. Arterial phase scans were acquired 20-40 seconds after contrast material administration; venous phase scans, 70-100 seconds after administration. Three readers independently scored images in a blinded fashion for the presence of tumor, for lesion attenuation relative to normal pancreas, and for vascular opacification. RESULTS: The final diagnosis was pancreatic malignancy (n = 60), acute or chronic pancreatitis (n = 22), and normal pancreas (n = 13). The readers identified possible or definite tumors on arterial phase studies in 47-50 patients and on venous phase studies in 48-53 patients (P > .10). There was no statistically significant difference in tumor attenuation between scans from the two phases (P > .05). Agreement between the readers for tumor detection was not affected by the scanning phase (P > .10). Opacification of arteries and of veins was greater on arterial phase scans and on venous phase scans, respectively (P < .001). CONCLUSION: The acquisition of arterial phase scans in addition to venous phase scans does not result in improved detection of pancreatic malignancies.

Adult↗