Search PubMed⌕ Search

Biomedical subjects

D H Sheafor

Publications and source records attributed to D H Sheafor.

At least 19 recordsLinked to original sources

Hepatic parenchymal enhancement during triple-phase helical CT: can it be used to predict which patients with breast cancer will develop hepatic metastases?

PURPOSE: To evaluate the efficacy of hepatic enhancement characteristics for identification of patients with breast cancer who are at risk for future hepatic metastases. MATERIALS AND METHODS: Triple-phase helical computed tomography (CT) was performed in 60 patients with known breast cancer without visible hepatic metastases. Peak hepatic attenuation and enhancement, and attenuation and enhancement at 25 and 30 seconds were obtained. Ratios of hepatic attenuation or enhancement at 25 and 30 seconds to peak hepatic attenuation or enhancement were calculated. A Wilcoxon rank sum test was used to compare patients with and those without subsequent hepatic metastases. RESULTS: During a mean 18-month follow-up, 18 patients (30%) developed hepatic metastases. Decreases in peak hepatic attenuation and enhancement and increases in hepatic attenuation and enhancement ratios at 25 and 30 seconds were seen in patients who developed metastases compared with those who did not (P < .05). When corrected for chemotherapy interval, these differences were not statistically significant. Using a threshold value of 0.40 or more for the enhancement ratio at 30 seconds resulted in sensitivity of 28%, specificity of 92%, and accuracy of 55%. CONCLUSION: Patients with breast cancer who develop subsequent hepatic metastases have higher relative hepatic arterial perfusion during triple-phase CT; however, after correction for chemotherapy interval, this difference was not statistically significant. Threshold values cannot be used reliably to identify patients who will develop metastases.

Adult↗

Treatment of iatrogenic femoral arterial pseudoaneurysms: comparison of US-guided thrombin injection with compression repair.

PURPOSE: To evaluate and compare the treatment of iatrogenic femoral arterial pseudoaneurysms by using ultrasonographically (US) guided direct thrombin injection with US-guided compression repair. MATERIALS AND METHODS: Twenty-six patients with iatrogenic femoral arterial pseudoaneurysms were treated with direct thrombin injection. With US guidance, a 22-gauge needle was placed into the pseudoaneurysm flow lumen and thrombin (mean volume, 0.35 mL; range, 0.10-0.60 mL) was injected with continuous color Doppler US guidance. Demographics, clinical variables, pseudoaneurysm characteristics, and results in these patients were compared with those in 281 consecutive patients who underwent US-guided compression repair. RESULTS: The success rate of thrombin injection was 96% (25 of 26 patients), which was significantly higher than that of compression, 74% (209 of 281 patients) (P =.013). Twenty of 26 (77%) patients required a single injection, and six (23%) required two injections. Mean thrombosis time for thrombin injection was 6 seconds, compared with 41.5 minutes for compression. For thrombin injection, there were no complications, foot pulses did not change and no patients required conscious sedation. Follow-up US at 24 hours showed no recurrent pseudoaneurysms. CONCLUSION: For the treatment of iatrogenic femoral arterial pseudoaneurysms, thrombin injection with US guidance appears to be superior to compression repair.

Aged↗

Nonenhanced helical CT and US in the emergency evaluation of patients with renal colic: prospective comparison.

PURPOSE: To compare nonenhanced helical computed tomography (CT) with ultrasonography (US) for the depiction of urolithiasis. MATERIALS AND METHODS: During 9 months, 45 patients (mean age, 44 years; mean weight, 92.5 kg) prospectively underwent both nonenhanced helical CT (5-mm collimation; pitch of 1.5) and US of the kidneys, ureters, and bladder. US evaluation included a careful search for ureteral calculi. Presence of calculi and obstruction and incidental diagnoses were recorded. Clinical, surgical, and/or imaging follow-up data were obtained in all patients. The McNemar test was used to compare groups. RESULTS: Diagnoses included 23 ureteral calculi and one each of renal cell carcinoma, appendicitis, ureteropelvic junction obstruction, renal subcapsular hematoma, cholelithiasis, medullary calcinosis, and myelolipoma. CT depicted 22 of 23 ureteral calculi (sensitivity, 96%). US depicted 14 of 23 ureteral calculi (sensitivity, 61%). Differences in sensitivity were statistically significant (P: =.02). Specificity for each technique was 100%. When modalities were compared for the detection of any clinically relevant abnormality (eg, unilateral hydronephrosis and/or urolithiasis in patients with an obstructing calculus), sensitivities of US and CT increased to 92% and 100%, respectively. One case of appendicitis was missed at US, whereas medullary calcinosis and myelolipoma were missed at CT. CONCLUSION: Nonenhanced CT has a higher sensitivity for the detection of ureteral calculi compared with US.

Adult↗

Evaluation of pseudoenhancement of renal cysts during contrast-enhanced CT.

OBJECTIVE: The purpose of our study was to evaluate renal cyst pseudoenhancement during helical CT in a phantom model and in patients. MATERIALS AND METHODS: Iodine baths containing water-filled spheres and cylinders were constructed to simulate cysts in enhancing renal parenchyma. Iodine concentration, cyst size and location, collimation, and peak kilovoltage were varied and cyst attenuation was measured. Data were analyzed with the mixed linear models and Mantel-Haenszel tests. Subsequently, a paired t test compared CT attenuation values before and after contrast material enhancement in 40 patients with 68 renal cysts (radiographic stability >3 months). RESULTS: The attenuation values of phantom cysts increased when placed in a contrast media bath (p = 0.001). The increase in attenuation values became more pronounced with increasing iodine concentrations, decreasing peak kilovoltage, and smaller sphere sizes. In patients, mean cyst attenuation increased 3.4 +/- 6.2 H after administration of contrast material (p = 0.00002). The attenuation did not increase more than 10 H in any of the 37 cysts larger than 2 cm found in patients. Eight (26%) of the 31 cysts smaller than 2 cm found in patients increased by at least 10 H. CONCLUSION: In a phantom model, at simulated physiologic levels of renal enhancement, cysts may pseudoenhance by more than 10 H. Similarly, in patients, cysts may also pseudoenhance; however, most pseudoenhancement does not exceed 10 H. In patients, pseudoenhancement of at least 10 H is more likely in cysts smaller than 2 cm.

Humans↗

Comparison of sonographic and CT guidance techniques: does CT fluoroscopy decrease procedure time?

OBJECTIVE: Procedure times for percutaneous biopsies were compared for various guidance techniques including helical CT, CT fluoroscopy, sonography with an attached needle guide, and freehand sonography with computer guidance. MATERIALS AND METHODS: Three interventional radiologists experienced in CT- and sonographically guided procedures performed biopsies on a phantom model. The phantom simulated hepatic metastases of various sizes and depths with subcostal or intercostal locations. Lesion sizes were 7, 10, and 20 mm, at 3- and 7-cm depths. Using self-aspirating needles, two passes were performed in each lesion. Mean procedure time per biopsy pass was calculated. A two-tailed Student's t test was used to compare guidance techniques. RESULTS: Mean procedure time per biopsy pass for the four guidance techniques was sonography with a needle guide, 36+/-9 sec; sonography with computer guidance, 43+/-10 sec; helical CT, 146+/-42 sec; and CT fluoroscopy, 50+/-18 sec. CT fluoroscopy required 2.6+/-1.0 sec per biopsy. Helical CT required more procedure time than sonography with a needle guide, CT with computer guidance, and CT fluoroscopy (p < 0.0001). Sonography with a needle guide required less procedure time than sonography with computer guidance (p < 0.002) and CT fluoroscopy (p = 0.0003). Procedure times for CT fluoroscopy and sonography with computer guidance were not statistically different (p = 0.06). CT and sonographic guidance were equally effective regardless of lesion size, depth, or location. CONCLUSION: Traditional sonographic biopsy techniques are faster and more cost-effective than traditional CT techniques; however, CT fluoroscopy offers the localization advantages of CT with improved procedure times.

Abdomen↗

Transjugular intrahepatic portosystemic shunts (TIPS): effects of respiratory state and patient position on the measurement of Doppler velocities.

OBJECTIVE: The purpose of this prospective study was to examine the effects of patient position and respiratory state on the measurements of Doppler velocities in transjugular intrahepatic portosystemic shunts. SUBJECTS AND METHODS: Thirty-eight transjugular intrahepatic portosystemic shunts in 34 consecutive patients were studied using Doppler sonography. Peak velocities were measured in the mid shunt with the patient in three positions (supine, sitting upright, and left lateral decubitus) and two respiratory states (deep inspiration and quiet respiration). A mixed linear regression model was used to assess statistically significant differences among the six velocity measurements. RESULTS: Peak velocities in the mid stent averaged 22 cm/sec greater in quiet respiration than in deep inspiration, which was a significant difference (p < 0.00001). Differences in velocities in the three patient positions were not significant (p = 0.53). Using 90-190 cm/sec as the normal range, the peak velocity shifted from normal to abnormal levels by changing respiratory state in 17 (45%) of 38 studies. Using 60 cm/sec as the lower normal limit, the peak velocity fell below the normal range with inspiration in 10 (26%) of 38 studies. In 12 (32%) of 38 studies, a decline in peak velocity exceeding 50 cm/sec could be induced by inspiration. CONCLUSION: Peak systolic velocity in transjugular intrahepatic portosystemic shunts is substantially altered by the respiratory state of the patient at the time of the measurement, but not by the patient position. Respiratory state must be taken into account in the interpretation of peak velocity for shunt stenosis.

Adult↗

Fine-needle aspiration findings in idiopathic retroperitoneal fibrosis.

Idiopathic retroperitoneal fibrosis (IRF) is an inflammatory and fibrosing process that can be complicated by periureteral encasement, ureteral obstruction, and subsequent renal failure if left untreated. Unfortunately, treatment is often delayed due to the nonspecific nature of the presenting signs and symptoms. Clinical, radiologic, and microscopic findings in IRF, if examined independently, are all nonspecific for its diagnosis. Rendering a diagnosis of IRF by fine-needle aspiration (FNA) requires supportive clinical and radiologic data and systematic evaluation of entities in the differential diagnosis. Herein we report 2 cases of IRF diagnosed by FNA with subsequent histologic confirmation. Smears prepared from the aspirates revealed a combination of inflammatory cells and fibrous tissue. The inflammatory component was comprised of a mixture of lymphocytes, plasma cells, and rare eosinophils and mast cells. These 2 cases represent, to our knowledge, only the second report of IRF diagnosed by FNA.

Aged↗

Comparison of unenhanced, hepatic arterial-dominant, and portal venous-dominant phase helical CT for the detection of liver metastases in women with breast carcinoma.

OBJECTIVE: The purpose of this study was to evaluate triple-phase helical CT for detection of hepatic metastases from breast carcinoma. SUBJECTS AND METHODS: Breast cancer patients were studied prospectively with triple-phase helical CT in 300 consecutive examinations. Hepatic arterial-dominant and portal venous-dominant phase scans were initiated at 20 and 65 sec, respectively, after IV injection of 175 ml of iopamidol (30 mg/ml) at 5 ml/sec. Three independent observers each reviewed 200 cases of the portal venous-dominant phase for lesion number, conspicuity, and attenuation. Subsequently, portal venous-dominant phase images were reevaluated in conjunction with hepatic arterial-dominant phase or unenhanced images. RESULTS: Hepatic metastases were identified in 79 (26%) of 300 cases. Lesions detected on portal venous-dominant, hepatic arterial-dominant, and unenhanced images were as follows: observer 1, n = 198, 164, and 171; observer 2, n = 254, 233, and 233; and observer 3, n = 291, 270, and 276 (p > .05). The mean total lesion count was 387, with more lesions detected on portal venous-dominant phase than on either hepatic arterial-dominant phase or unenhanced images (p < .001 and p < .0001, respectively). For individual observers, 10-26% of lesions were hypervascular on hepatic arterial-dominant phase images. Two to 4% of lesions were identified only on hepatic arterial-dominant phase or unenhanced images. However, in these few cases, the lesions either were false-positives or were seen in conjunction with additional metastases on portal venous-dominant images. CONCLUSION: Routine use of triple-phase CT in patients with breast carcinoma may not be warranted: Addition of the hepatic arterial-dominant phase or unenhanced images revealed few additional lesions in our group of 300 patients.

Adult↗

PACS in sonography: accuracy of interpretation using film compared with monitor display. Picture archiving and communication systems.

OBJECTIVE: The goal of this study was to determine the relative accuracy of interpretation of sonography when viewed on a monitor or on film. MATERIALS AND METHODS: Four radiologists twice interpreted a series of 440 sonograms using the following sequences of display formats for initial and second interpretations: film-film, film-monitor, monitor-film, and monitor-monitor. Reporting discrepancies between the initial and subsequent interpretation were reviewed by an arbitration panel unaware of the display mode. Results were analyzed for differences in error rate attributable to film versus monitor display format, chronology of interpretation, individual observer, and observer seniority. RESULTS: We found no statistically significant difference in the error rate for film (10.3%) versus monitor display format (14.6%) (p = .09). Likewise, we found no significant differences in the error rates attributable to chronology of interpretation (p = .13), individual observer (p = .54), or observer seniority (p = .87). CONCLUSION: Interpretative accuracy is similar whether sonograms are interpreted on a monitor or on film.

Artifacts↗

Percutaneous liver biopsy: a cost-benefit analysis comparing sonographic and CT guidance.

OBJECTIVE: We compared the relative cost of a liver biopsy performed with sonographic guidance with that of one performed with CT guidance in a cost-benefit analysis model. MATERIALS AND METHODS: Variables were estimated from a search of the literature and from clinical experience with 437 hepatic biopsies at our institution. Probability variables included the probability of obtaining an adequate sample and the probability of a major complication. Cost variables included the direct and indirect costs, the cost of a major complication, and the opportunity costs of foregone revenue from preempted diagnostic studies. One-way and two-way sensitivity analyses were performed. RESULTS: Using baseline values, CT guidance was 1.89 times more expensive than sonographic guidance. Sensitivity analyses indicate that CT and sonographic guidance costs would be equivalent if the success rate with sonographic guidance was 39.8%, the opportunity costs of CT guidance were 3.13 times less than best estimates, and the opportunity costs of sonography were 3.15 times greater than best estimates. CONCLUSION: Sonographic guidance for hepatic biopsies is substantially more economical than CT guidance across a wide range of estimated costs.

Biopsy, Needle↗

Dynamic helical CT of the abdomen: prospective comparison of pre- and postprandial contrast enhancement.

PURPOSE: To investigate effects of a liquid meal on contrast material enhancement at dynamic helical computed tomography (CT). MATERIALS AND METHODS: Twenty healthy, fasting subjects underwent intravenous injection of nonionic contrast material at 4 mL/sec. Axial CT sections were obtained at a single level 15 seconds after injection, then every 5 seconds for 2 minutes. This protocol was repeated 1 week later, after ingestion of a 360-calorie liquid meal. Hepatic, splenic, and aortic attenuation were measured before and after contrast material administration. Peak enhancement level, time to peak enhancement, slope of hepatic enhancement, and hepatic, splenic, and aortic enhancement ratios were determined. RESULTS: Postprandial time to peak enhancement was 4.4 seconds earlier than preprandial (59.6 seconds +/- 9.0 [1 standard deviation] vs 64.0 seconds +/- 9.5; P < .02). No differences in maximum attenuation were found (P > .27). Postprandial maximum slope of hepatic enhancement and temporal and quantitative enhancement characteristics in aorta and spleen did not significantly differ. Postprandial hepatic-to-splenic enhancement ratios increased (P = .04), and aortic-to-hepatic ratios decreased (P = .01). Aortic-to-splenic ratios did not differ (P = .45). CONCLUSION: A liquid meal before intravenous injection of contrast material produces more rapid peak hepatic enhancement, with slightly increased relative hepatic enhancement. A patient's dietary status, however, should not influence the CT protocol.

Adult↗

Abdominal percutaneous interventional procedures: comparison of CT and US guidance.

PURPOSE: To compare ultrasound (US) with computed tomography (CT) as a guidance modality for percutaneous interventional procedures. MATERIALS AND METHODS: A database of abdominal interventional procedures was reviewed for the 6 months preceding and 6 months after the opening of a dedicated US interventional suite. Changes in the number and type of procedures performed, room time, number of needle passes, and complication rates were calculated. RESULTS: In the first 6 months, 305 interventional procedures (138 tissue biopsies and 167 fluid aspirations) were performed (CT guidance in 87% [n = 120] and 95% [n = 159], respectively). In the 6 months after installation of the suite, 395 procedures (195 tissue biopsies and 200 fluid aspirations) were performed (US guidance in 76% [n = 148] and 34% [n = 67], respectively). The largest increase in US utilization was for guidance of tissue biopsies, rising from 6% (18 of 305) to 37% (148 of 395) of all procedures. Room time was significantly less for US-guided procedures (mean US room time, 77 minutes +/- 33 [1 standard deviation]; mean CT room time, 99 minutes +/- 38; P < .0001). CONCLUSION: US guidance often allows performance of quicker, more accurate procedures than does CT guidance, probably because of its real-time capabilities.

Abdomen↗

Scrotal pathology as the cause for hip pain. Diagnostic findings on bone scintigraphy.

Scrotal scintigraphy has become a relatively uncommon examination in many nuclear medicine departments. However, scrotal perfusion is visualized during three-phase bone imaging of the pelvis and hips. The authors present a compilation of three cases of hip pain secondary to unsuspected scrotal pathology documented on routine three-phase bone scintigraphy, discussing this topic for the first time in the literature. A short review of the pathophysiology of referred hip pain, differential diagnosis, and imaging alternatives emphasize the unique contribution of nuclear imaging.

Adolescent↗

Small lymph nodes of the abdomen, pelvis, and retroperitoneum: usefulness of sonographically guided biopsy.

PURPOSE: To evaluate the usefulness of sonographically guided percutaneous biopsy of small lymph nodes in the abdomen, retroperitoneum, and pelvis. MATERIALS AND METHODS: From May 1995 through January 1997, 35 sonographically guided lymph node biopsies were performed in 34 patients. All biopsies were performed with a 20- (n = 18) or 22-gauge (n = 10) self-aspirating needle alone or in combination (n = 7). To determine the amount of compression achieved with the transducer, the skin-to-lesion distance on reference computed tomographic (CT) scans was compared with that on sonograms. A biopsy was considered successful if a specific benign or malignant diagnosis was rendered by the pathologist. RESULTS: Of 35 sonographically guided biopsies, 30 (86%) were successful. Diagnoses included 26 (74%) cases of carcinoma, three (9%) cases of benign reactive lymphocytosis confirmed at open biopsy, and one (3%) case of a lymph node with a positive acid-fast bacilli stain. The average lymph node diameter was 2.1 cm (range, 0.9-4.3 cm). With sonography, a mean of 2.5 needle passes (range, 1-5) were made per biopsy. Transducer compression reduced the skin-to-lesion distance from an average of 8.8 cm (at CT) to 4.5 cm. CONCLUSION: Sonographic guidance seems to provide a reasonable alternative to CT in biopsy of small abdominal, pelvic and retroperitoneal lymph nodes.

Abdomen↗