Prospective MR signal-based cardiac triggering.

A cardiac motion compensation method using magnetic resonance signal-based triggering is presented. The method interlaces a triggering pulse sequence with an imaging sequence. The triggering sequence is designed to measure aortic blood velocity, from which cardiac phase can be inferred. The triggering sequence is executed repeatedly and the acquired data processed after each sequence iteration. When the desired phase of the cardiac cycle is detected, data are acquired using the imaging sequence. A signal-processing unit of a conventional scanner is used to process the triggering data in real time and issue triggering commands. Alternatively, a workstation, with a bus adaptor, can access data as they are acquired, process and display the data, and issue triggering commands. With a graphical user interface, the triggering pulse sequence and data-processing techniques can be modified instantaneously to optimize triggering. The technique is demonstrated with coronary artery imaging using both conventional two-dimensional Fourier transform scans and spiral trajectories.

Aorta, Thoracic↗

Flow quantification using low-spatial-resolution and low-velocity-resolution velocity images.

In this report, a flow-quantification method using Fourier velocity encoding (FVE) with limited spatial and velocity resolution is presented. The total flow rate in a vessel corresponds to the first moment of the velocity histogram of spins in the vessel, whereas the spin density of flowing spins is the normalization constant. Because the measured histogram using FVE is distorted by RF saturation effects, the RF saturation effects are first estimated and then accurately compensated by acquiring five velocity-encoded images. The spatial resolution in each image can be relatively low because all stationary spins vanish in the resultant flow map. In a phantom study, the errors in measured flow rates were within +/-10% even when the pixel size was greater than the vessel size. This method was also successfully applied to measure flow in the femoral artery. In general, this method constitutes a basis for analyzing multiple velocity-encoded images and is particularly useful for quantifying slow flow or flow in small vessels. Magn Reson Med 42:682-690, 1999.

Blood Flow Velocity↗

MR imaging of articular cartilage using driven equilibrium.

The high incidence of osteoarthritis and the recent advent of several new surgical and non-surgical treatment approaches have motivated the development of quantitative techniques to assess cartilage loss. Although magnetic resonance (MR) imaging is the most accurate non-invasive diagnostic modality for evaluating articular cartilage, improvements in spatial resolution, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) would be valuable. Cartilage presents an imaging challenge due to its short T(2) relaxation time and its low water content compared with surrounding materials. Current methods sacrifice cartilage signal brightness for contrast between cartilage and surrounding tissue such as bone, bone marrow, and joint fluid. A new technique for imaging articular cartilage uses driven equilibrium Fourier transform (DEFT), a method of enhancing signal strength without waiting for full T(1) recovery. Compared with other methods, DEFT imaging provides a good combination of bright cartilage and high contrast between cartilage and surrounding tissue. Both theoretical predictions and images show that DEFT is a valuable method for imaging articular cartilage when compared with spoiled gradient-recalled acquisition in the steady state (SPGR) or fast spin echo (FSE). The cartilage SNR for DEFT is as high as that of either FSE or SPGR, while the cartilage-synovial fluid CNR of DEFT is as much as four times greater than that of FSE or SPGR. Implemented as a three-dimensional sequence, DEFT can achieve coverage comparable to that of other sequences in a similar scan time. Magn Reson Med 42:695-703, 1999.

Cartilage, Articular↗

Nonsubtractive spiral phase contrast velocity imaging.

Phase contrast velocity imaging is a standard method for accurate in vivo flow measurement. One drawback, however, is that it lengthens the scan time (or reduces the achievable temporal resolution) because one has to acquire two or more images with different flow sensitivities and subtract their phases to produce the final velocity image. Without this step, non-flow-related phase variations will give rise to an erroneous, spatially varying background velocity. In this paper, we introduce a novel phase contrast velocity imaging technique that requires the acquisition of only a single image. The idea is to estimate the background phase variation from the flow-encoded image itself and then have it removed, leaving only the flow-related phase to generate a corrected flow image. This technique is sensitive to flow in one direction and requires 50% less scan time than conventional phase contrast velocity imaging. Phantom and in vivo results were obtained and compared with those of the conventional method, demonstrating the new method's effectiveness in measuring flow in various vessels of the body. Magn Reson Med 42:704-713, 1999.

Aorta, Abdominal↗

High-resolution three-dimensional in vivo imaging of atherosclerotic plaque.

The internal structure of atherosclerotic-plaque lesions may be a useful predictor of which lesions will rupture and cause sudden events such as heart attack or stroke. With lipid and flow suppression, we obtained high-resolution, three-dimensional (3D) images of atherosclerotic plaque in vivo that show the cap thickness and core size of the lesions. 3D GRASE was used because it provides flexible T(2) contrast and good resistance to off-resonance artifacts. While 2D RARE has similar properties, its resolution in the slice-select direction, which is important because of the irregular geometry of atherosclerotic lesions, is limited by achievable slice-excitation profiles. Also, 2D imaging generally achieves lower SNR than 3D imaging because, for SNR purposes, 3D image data is averaged over all the slices of a corresponding multislice 2D dataset. Although 3D RARE has many of the advantages of 3D GRASE, it requires a longer scan time because it uses more refocusing pulses to acquire the same amount of data. Finally, cardiac gating is an important part of our imaging sequence, but can make the imaging time quite long. To obtain reasonable scan times, a 2D excitation pulse was used to restrict the field of view. Magn Reson Med 42:762-771, 1999.

Aorta, Thoracic↗

Fluctuating equilibrium MRI.

A new fast, spectrally selective imaging method called fluctuating equilibrium magnetic resonance is presented. With all gradients refocused over a repetition interval, certain phase schedules of radiofrequency excitation pulses produce an equilibrium magnetization that fluctuates from excitation to excitation, thus permitting simultaneous acquisition of several images with different contrast features. For example, lipid and water images can be rapidly acquired. The effective echo time can be adjusted using the flip angle, thus providing control over the T(2) contribution to the contrast. Several applications of the technique are presented, including fast musculoskeletal, abdominal, breast, and brain imaging, in addition to MR angiography. A technique for combining lipid and water images generated with this sequence for angiography is described and other potential applications are suggested. Magn Reson Med 42:876-883, 1999.

Abdomen↗

One-shot spatially resolved velocity imaging.

For quantitative velocity measurement, we have developed a technique that acquires full velocity spectra without cardiac gating. After a cylindrical excitation restricts imaging to one spatial dimension, data are acquired while an oscillating gradient is played out. After each excitation, an image of velocity versus spatial location is obtained. For a given spatial location, a series of these images can be used to form an image of velocity versus time. Acquisition times are much shorter than for phase-contrast imaging or Fourier-encoded velocity imaging, obviating the need for cardiac gating. Although a two-shot version of this technique has been presented previously, we have developed a one-shot version that offers higher temporal resolution for a given velocity resolution and superior off-resonance properties.

Aorta, Thoracic↗

3D MR coronary artery segmentation.

Coronary arteries are segmented from the blood pool using mathematical morphology operations from a 3D magnetic resonance spiral acquisition on a continuously breathing healthy volunteer. The segmented volume is maximal intensity projected at different views to yield coronary angiograms showing the left anterior descending artery (LAD), right coronary artery (RCA), and left circumflex artery (LCX). Magnetic resonance coronary angiography provides a retrospective rotating view of the coronary artery tree that complements oblique reformatted sections.

Algorithms↗

Improved 2D time-of-flight angiography using a radial-line k-space acquisition.

For flow imaging applications, radial-line k-space acquisition methods offer advantages over conventional 2DFT methods. Specifically, radial-line acquisition methods mitigate artifacts resulting from pulsatile flow while offering a potential reduction in scan times. In this paper, radial-line and 2DFT acquisitions are compared in a two-dimensional time-of-flight angiography sequence. The twisting radial-line (TwiRL) trajectory, a variant of 2D projection reconstruction, is used to represent the family of radial-line trajectories. In both phantom and in vivo studies, the TwiRL images demonstrate improved vessel depiction including a more uniform signal intensity and better delineation of the vasculature in comparison with images obtained via the 2DFT method.

Arterial Occlusive Diseases↗

Reducing flow artifacts in echo-planar imaging.

Echo-planar imaging (EPI) is very susceptible to flow artifacts. Two ways to improve its flow properties are presented. First, "partial flyback" is proposed to reduce artifacts arising from flow in the readout direction. Near the center of k-space, only the even echoes of the EPI echo-train are used. Partial flyback is shown to improve the readout-flow properties at the expense of a slight worsening of the phase-encode flow and off-resonance properties. We recommend that the flyback region acquire 95% of the energy in k-space. Second, "inside-out" EPI is used to reduce artifacts arising from flow in the phase-encode direction. Data collection begins at the center of k-space, with separate interleaves to acquire the top and bottom, halves of k-space. Partial flyback is combined with partial-Fourier EPI and inside-out EPI. Partial-flyback inside-out EPI has worse off-resonance properties than partial-flyback partial-Fourier EPI but demonstrates better flow properties and does not require partial k-space reconstruction.

Heart↗

Three-dimensional flow-independent peripheral angiography.

A magnetization-prepared sequence, T2-Prep-IR, exploits T1, T2, and chemical shift differences to suppress background tissues relative to arterial blood. The resulting flow-independent angiograms depict vessels with any orientation and flow velocity. No extrinsic contrast agent is required. Muscle is the dominant source of background signal in normal volunteers. However, long-T2 deep venous blood and nonvascular fluids such as edema also contribute background signal in some patients. Three sets of imaging parameters are described to address patient-specific contrast requirements. A rapid, spiral-based, three-dimensional readout is utilized to generate high-resolution angiograms of the lower extremities. Comparisons with x-ray angiography and two-dimensional time-of-flight angiography indicate that this flow-independent technique has unique capabilities to accurately depict stenoses and to visualize slow flow and in-plane vessels.

Angiography↗

Real-time interactive MRI on a conventional scanner.

A real-time interactive MRI system capable of localizing coronary arteries and imaging arrhythmic hearts in real-time is described. Non-2DFT acquisition strategies such as spiral-interleaf, spiral-ring, and circular echo-planar imaging provide short scan times on a conventional scanner. Real-time gridding reconstruction at 8-20 images/s is achieved by distributing the reconstruction on general-purpose UNIX workstations. An X-windows application provides interactive control. A six-interleaf spiral sequence is used for cardiac imaging and can acquire six images/s. A sliding window reconstruction achieves display rates of 16-20 images/s. This allows cardiac images to be acquired in real-time, with minimal motion and flow artifacts, and without breath holding or cardiac gating. Abdominal images are acquired at over 2.5 images/s with spiral-ring or circular echo-planar sequences. Reconstruction rates are 8-10 images/s. Rapid localization in the abdomen is demonstrated with the spiral-ring acquisition, whereas peristaltic motion in the small bowel is well visualized using the circular echo-planar sequence.

Abdomen↗

Inhomogeneity correction using an estimated linear field map.

A fast and robust method for correcting magnetic resonance image distortion due to field inhomogeneity is proposed and applied to spiral k-space scanning. The method consists of acquiring a local field map, finding the best fit to a linear map, and using it to deblur the image distortions due to local frequency variations. The linear field map is determined using a maximum likelihood estimator with weights proportional to the pixel intensity. The method requires little additional computation and is robust in low signal regions and near abrupt field changes. Additionally, it can be used in combination with other deblurring methods. The application of this method is illustrated in conjunction with a multislice, T2-weighted, breath-held spiral scan of the liver.

Abdomen↗

A velocity k-space analysis of flow effects in echo-planar and spiral imaging.

A velocity k-space formalism facilitates the analysis of flow effects for imaging sequences involving time-varying gradients such as echo-planar and spiral. For each sequence, the velocity k-space trajectory can be represented by kv(kr); that is, its velocity-frequency (kv) position as a function of spatial-frequency (kr) position. In an echo-planar sequence, kv is discontinuous and asymmetric. However, in a spiral sequence, kv is smoothly varying, circularly symmetric, and small near the kr origin. To compare the effects of these trajectory differences, simulated images were generated by computing the k-space values for an in-plane vessel with parabolic flow. Whereas the resulting echo-planar images demonstrate distortions and ghosting that depend on the vessel orientation, the spiral images exhibit minimal artifacts.

Artifacts↗

Fast three dimensional magnetic resonance imaging.

To reduce the scan time in three-dimensional (3D) imaging, the authors consider alternative trajectories for traversing k-space. They differ from traditional 3D trajectories, such as 3DFT, in that they employ time-varying gradients allowing longer readouts and in turn a reduced scan time. Some of these trajectories reduce by an order of magnitude the number of excitations compared with 3DFT and provide flexibility for trading off signal-to-noise ratio for scan time. Other concerns are the minimum echo time and flow/motion properties. As examples, the authors show two applications: A 3D data set of the head (field of view of 30 x 30 x 7.5 cm and resolution of 1.5 x 1.5 x 1.5 mm) acquired in 56 s using a stack of spirals in 3D k-space; and a 3D movie of the heart (20 x 20 x 20 cm field of view, 2 x 2 x 2 mm resolution, and 16 time frames per cardiac cycle) acquired in 11 min using a cones trajectory.

Fourier Analysis↗

Coronary angiography with magnetization-prepared T2 contrast.

A magnetization-prepared, T2-weighted sequence (T2 Prep) is used to suppress muscle and venous structures. When combined with lipid suppression, this technique improves the visualization of the coronary arteries. T2 Prep was designed to be rebust in the presence of flow as well as B0 and B1 inhomogeneities and may be combined with virtually any imaging technique. Here, it is implemented with both a single-slice spiral acquisition and a multi-slice spiral method that acquires up to 15 slices in a single breath-holding interval.

Arteries↗

The diminishing variance algorithm for real-time reduction of motion artifacts in MRI.

A technique has been developed whereby motion can be detected in real time during the acquisition of data. This enables the implementation of several algorithms to reduce or eliminate motion effects from an image as it is being acquired. One such algorithm previously described is the acceptance/rejection method. This paper deals with another real-time algorithm called the diminishing variance algorithm (DVA). With this method, a complete set of preliminary data is acquired along with information about the relative motion position of each frame of data. After all the preliminary data are acquired, the position information is used to determine which data frames are most corrupted by motion. Frames of data are then reacquired, starting with the most corrupted one. The position information is continually updated in an iterative process; therefore, each subsequent reacquisition is always done on the worst frame of data. The algorithm has been implemented on several different types of sequences. Preliminary in vivo studies indicate that motion artifacts are dramatically reduced.

Algorithms↗

Real-time motion detection in spiral MRI using navigators.

A technique has been developed whereby motion can be detected in real time during the acquisition of data. This enables the implementation of an algorithm to accept or reject and reacquire data during a scan. Frames of data with motion are rejected and reacquired on the fly so that by the end of the scan, a complete motion-free data set has been acquired. The algorithm has been implemented on several different types of sequences. Preliminary in vivo studies indicate that motion artifacts are dramatically reduced.

Abdomen↗