Search PubMed⌕ Search

PubMed · 9055235

Reducing flow artifacts in echo-planar imaging.

Abstract

Echo-planar imaging (EPI) is very susceptible to flow artifacts. Two ways to improve its flow properties are presented. First, "partial flyback" is proposed to reduce artifacts arising from flow in the readout direction. Near the center of k-space, only the even echoes of the EPI echo-train are used. Partial flyback is shown to improve the readout-flow properties at the expense of a slight worsening of the phase-encode flow and off-resonance properties. We recommend that the flyback region acquire 95% of the energy in k-space. Second, "inside-out" EPI is used to reduce artifacts arising from flow in the phase-encode direction. Data collection begins at the center of k-space, with separate interleaves to acquire the top and bottom, halves of k-space. Partial flyback is combined with partial-Fourier EPI and inside-out EPI. Partial-flyback inside-out EPI has worse off-resonance properties than partial-flyback partial-Fourier EPI but demonstrates better flow properties and does not require partial k-space reconstruction.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G T Luk Pat, C H Meyer, J M Pauly, D G Nishimura. 1997. Reducing flow artifacts in echo-planar imaging.. https://doi.org/10.1002/mrm.1910370323

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Acute effects of continuous positive airway pressure on cardiac sympathetic tone in congestive heart failure.

BACKGROUND: Depressed ventricular performance and neurohormonal activation are key pathophysiological features of congestive heart failure (CHF). Although angiotensin-converting enzyme inhibitors and beta-adrenoceptor blockers exert beneficial effects in CHF, mortality remains unacceptably high, and the development of further therapeutic approaches is warranted. Recent data suggest that continuous positive airway pressure (CPAP) may be of benefit in the treatment of CHF, although the mechanism for this action is incompletely understood. METHODS AND RESULTS: In the present study, we examined the effect of short-term CPAP (10 cm H(2)O for 10 minutes) on hemodynamics (Swan Ganz catheter) and total systemic and cardiac sympathetic activity (norepinephrine spillover method) in 14 CHF patients in New York Heart Association class III. The application of CPAP was associated with a fall in cardiac output (4.8+/-0.3 to 4.4+/-0.2 L/min; P<0.05) and a significant reduction in cardiac norepinephrine spillover (370+/-58 to 299+/-55 pmol/min; P<0.05), although total systemic norepinephrine spillover was unchanged. CONCLUSION: The short-term application of CPAP results in an inhibition of cardiac sympathetic nervous activity. Further investigation into the potential value of long-term CPAP in CHF patients is warranted.

Heart↗