Search PubMed⌕ Search

Biomedical subjects

D F Bruley

Publications and source records attributed to D F Bruley.

61 records · Page 4Linked to original sources

Highly scattering optical system identification via frequency response analysis of NIR-TRS spectra.

Frequency response analysis via pulse testing is often used for the characterization of engineering systems. Near infrared-time resolved spectroscopy (NIR-TRS) is a frequently used technique for the analysis of biological system properties. Since the TRS input is a very sharp photon pulse, a well designed TRS input pulse can produce a multi-frequency response over the useful frequency range for the system identification. This new approach for analyzing NIR-TRS provides new optical system parameters (e.g., magnitude ratio and phase shift at multi-frequencies, system time constant, system order, and steady state gain) that are not available by traditional TRS spectra analysis. In this paper, the basic theory of pulse reduction is introduced for the multi-modulation frequency response of TRS spectra. Homogeneous system response with various absorption and scattering properties were analyzed for the multi-system parameters. In heterogeneous systems, the position of the localized absorber is correlated with the multi-parameters, which can ultimately be used to enhance medical imaging.

Absorption↗

Application of near-IR time-resolved spectroscopy and frequency response analysis for deep vein thrombosis detection.

Frequency response analysis is applied to analyze NIR-TRS spectra in a tissue model with a simulated thrombus. The value changes in parameters obtained from frequency response analysis are correlated with heterogeneity position in three dimensions. The goal of this research is to noninvasively localize deep vein thrombosis in the human leg through the use of this novel combination.

Humans↗

Homologous human blood protein separation using immobilized metal affinity chromatography: protein C separation from prothrombin with application to the separation of factor IX and prothrombin.

Protein C (PC) is a natural anticoagulant and antithrombotic present in human blood at a concentration of 4 microg/mL. Its deficiency can result in excessive clotting and thrombosis. Protein C can be obtained from human blood plasma; however, there are other coagulant proteins in blood, including prothrombin (factor II), which is present in relatively large amounts and is one of the most active components. Protein C and prothrombin are homologous proteins with similar biochemical features; therefore, immunoaffinity chromatography is used for their separation. However, this technology is very expensive, protein C recovery and activity is low, and contamination problems with mouse antibody are likely. Immobilized metal affinity chromatography (IMAC) utilizes the protein metal-binding properties for protein separation. Protein C has twelve surface-accessible histidines, which are the major metal-binding groups for IMAC separation. After investigating metal ion-binding properties of protein C, we used an IDA-Cu column to separate protein C and prothrombin. Following protein adsorption to the column, prothrombin was washed out using a sodium phosphate buffer containing 2 mM imidazole and protein C was recovered with 15 mM imidazole in the buffer. The mild elution condition allows a high protein C activity and a high recovery. Also, this technology introduces no immunoglobulins, and it is relatively inexpensive. IMAC could replace the immunoaffinity technology for the large-scale separation of protein C from blood plasma Cohn Fraction IV-1. In addition, this work demonstrates a significant application of this technology for the separation of factor IX from prothrombin. Prothrombin has proven to be a harmful contaminant in factor IX cocktails that have been administered to humans in the treatment of hemophilia B.

Blood Proteins↗

Localization of a fluorescent object in highly scattering media via frequency response analysis of near infrared-time resolved spectroscopy spectra.

Frequency response analysis via pulse testing for engineering systems and near infrared (NIR) time resolved spectroscopy (TRS) for biological system characterization involve identical principles: the system of interest is disturbed by an input pulse and the output response is observed. Since a sharp pulse, such as the Dirac delta function, contains the information of multimodulation frequencies (theoretically from 0 to infinity in frequency) a narrow pulse TRS input can produce a wide range frequency response for identifying any system of interest. Currently used NIR-TRS spectral analyses either fit the spectra with a known theoretical solution or use photon mean time-of-flight. Transforming the system time domain representation to the frequency domain generates five system parameters that can be valuable for process identification utility: steady state gain, time constant, system order, and magnitude ratio and phase shift over a wide frequency range. Optical contrast agents or fluorescent agents can be used to enhance the capability of optical instruments in detecting biological heterogeneities. In this article, magnitude ratio, phase shift, and other system parameters derived from the transfer function of systems with both a fluorescent absorber and a regular absorber are correlated with the position of the absorber. This technique is important in that ultimately it can be used to enhance optical medical imaging.

Artifacts↗

Feasibility study of a single- and multiple-source near-infrared phase-modulation device for characterizing biologic systems.

Near-infrared (NIR) spectroscopy is an inexpensive and noninvasive optical method to characterize biologic and physiologic systems. Measurements of oxygen saturation in various organs, cytochrome oxidase concentration, and glucose concentration in tissue are examples of NIR spectroscopy applications. This instrument also has potential for diagnostic imaging by comparing the optical properties of a given point in tissue with those of the surrounding areas, e.g., tumor localization, hematoma detection, or deep vein thrombosis detection. Currently, NIR spectroscopy is available in three modalities: time-resolved spectroscopy (TRS), continuous-wave spectroscopy (CWS), and a phase-modulation device. This paper describes a single-source phase-modulation device and a multiple-source (in- and anti-phased) device and their application to system identification. The phase and intensity information for homogeneous systems is correlated with system and instrumental parameters. Phase and intensity changes resulting from the presence of one and two absorbers are illustrated. The sensitivity of in- and anti-phased phase-modulation devices (phased arrays) is demonstrated. The use of amplitude-modulated phased array for heterogeneity detection is described.

Computer Simulation↗