Suggested threshold sound pressure levels for frequency-modulated (warble) tones in the sound field.

The problems inherent in using frequency-specific stimuli in the sound field to determine threshold sensitivity are reviewed, including a discussion of some of the specific problems encountered when introducing pure tones, narrow bands of noise, and frequency-modulated (FM) tones. The results of two experiments are reported. In Experiment I, the relationship between pure tones and frequency-modulated tones is developed under earphones in an anechoic chamber, and in two sound-isolated auditory test rooms (not anechoic). Experiment I resulted in the development of a reference threshold sound pressure level for frequency-modulated signals in the sound field. In Experiment II the reference level was applied to a clinical test facility and evaluated with a group of hearing-impaired individuals. The results suggest that the sound-field reference levels accurately reflect monaural threshold under earphones, when the earphone is calibrated to the ANSI, 1969 standard, and the sound field is calibrated to the suggested standard.

Acoustic Stimulation↗

Bone conduction calibration: current status.

Attempts to specify normal threshold sensitivity by bone conduction have been unsuccessful because of problems in obtaining reliable measurements from commercially available artificial mastoids. Recent design modifications incorporated in the Bruel and Kjaer 4930 artificial mastoids have resulted in greater uniformity among these units. However, the new design has resulted in impedances that are higher than those recommended in current standards. Bone-conduction thresholds referenced to measurements made on B & K 4930 artificial mastoids with the new design were performed on 60 normal listeners by three participating laboratories. The results are reported for consideration in the development of a reference threshold for hearing by bone conduction.

Acoustic Impedance Tests↗

Loudness discomfort level and acoustic reflex threshold for speech stimuli.

Loudness discomfort level (LDL) and acoustic reflex threshold (ART) measurements were obtained from subjects with normal hearing using several speech stimuli, as well as broad-band and speech-spectrum noise. The purpose of the investigation was to determine the LDL for a variety of representative speech samples, and to determine the relationship between the LDL and ART for selected speech and noise stimuli. For all stimuli, LDL measurements were relatively constant, but ART measurements decreased significantly for wide-band noise stimuli as compared with the speech stimuli. Mean differences between the two measures were consistent, but individual subject data were characterized by wide variability precluding accurate prediction of the LDL from ART measurements.

Acoustic Stimulation↗

Exploring azimuth effects with an anthropometric manikin.

In these experiments, the effects of sound direction on the eardrum response of an anthropometric manikin (the KEMAR manikin) were investigated. Pure tones and pink noise (analyzed in 1/3-octave bandwidths) over a wide frequency range were used as signals as the manikin rotated 360 degrees with respect to a point source in a anechoic chamber. The simulated eardrum SPL was compared with the averaged human field-to-eardrum data reported by Shaw [J. Acoust. Soc. Am. 56, 1848--1861 (1974)]. It was concluded that the KEMAR manikin can be used up to frequencies of approximately 8.0 kHz, with (1) 1/3-octave pink noise signals to measure a response equivalent to tht obtained by averaging over a number of humans, and (2) pure-tone signals to measure the response equivalent to that of a single human having average head and ear dimensions.

Anthropometry↗

Effect of sensorineural hearing loss on loudness discomfort level and most comfortable loudness judgments.

A simple up-down adaptive procedure was used to estimate the 50% point on the psychometric function for loudness discomfort level (LDL) and the two functions describing the range of most comfortable loudness (MCL) for listeners with sensorineural hearing impairment. For pure tone and speech stimuli, median LDL and MCL levels were observed at relatively constant SPLs for subjects with hearing loss less than or equal to dB HL and at progressively higher SPLs with further increase in hearing loss. Correlation analysis verified a statistically significant relationship between LDL and magnitude of hearing loss. The nonlinear relationship between LDL and hearing loss together with the large intersubject variability in the data suggest that prediction of LDL from hearing threshold would often be highly inaccurate. These results also demonstrate that averaging LDL data across a group of subjects with a wide range of hearing loss may lead to inaccurate conclusions regarding the effects of sensorineural hearing loss on LDL.

Adolescent↗

The influence of middle-ear muscle contraction on auditory threshold for selected pure tones.

The influence of middle-ear muscle (MEM) contraction on auditory threshold has been measured for pure tones of 0.25, 0.5, and 1.5 kHz. The reflex-activating signal was a 3-kHz pure tone. Signal paradigms were chosen to reduce or eliminate the effects of binaural loudness summation, contralateral direct masking, and contralateral remote and backward masking effects, and to maximize the influence of MEM contraction. Results indicate that under no condition was behavioral threshold affected by the MEM contraction induced using a pure-tone stimulus of 3 kHz, 105 dB SPL.

Adult↗

Use of performance-intensity functions for diagnosis.

Performance-intensity (PI) functions for phonetically balanced (PB) word lists were obtained for a group of normal listeners (27 ears), and for two groups of patients with cochlear (89 ears) and retrocochlear disorders (eight ears). Listeners with normal hearing or cochlear disorders exhibited mild to moderate reductions in discrimination score as the speech level was raised above the PB maximum. In contrast, patients with retrocochlear disorders showed a pronounced rollover phenomenon, characterized by a rapid decline in performance as the speech level was raised above the maximum discrimination score.

Audiometry↗

Bone conduction thresholds for normal listeners in force and acceleration units.

In a previous article we reported on the standardization of normal hearing for bone conduction. All of our findings were reported in force units. Because many international users of this information express such findings in units of acceleration, we have, at the Editor's request, converted our force units into acceleration units to increase the scope of our results and to enhance their comparison with other investigations. This note presents data which may be useful to organization concerned with the development of standards for normal hearing by bone conduction.

Acceleration↗

Psychometric functions for loudness discomfort and most comfortable loudness levels.

Adaptive procedures were used to determine psychometric functions for loudness discomfort level (LDL) and most comfortable loudness (MCL) for pure tones and speech using normal and hearing-impaired listeners. For the LDL, both groups demonstrated steeply rising functions with the 50% point at approximately 100 dB SPL. The MCL data resulted in two functions, one (Function A) differentiating MCL from less intense stimulus levels and the second (Function B) differentiating between MCL and more intense levels. Function A may be considered a lower bound and Function B an upper bound for MCL. For the normal listeners, the difference between the functions at 50% response ranged from 9.9 to 19.9 dB depending upon the experimental condition. For the hearing-impaired subjects, this range was restricted to approximately 4.5 dB, primarily as a result of a shift in Function A toward higher sound pressure levels.