Atrial fibrillation-induced atrial contractile dysfunction: a tachycardiomyopathy of a different sort.

OBJECTIVE: Although AF-induced atrial contractile dysfunction has significant clinical implications the underlying intracellular mechanisms are poorly understood. METHODS: From the right atrial appendages of 59 consecutive patients undergoing mitral valve surgery (31 in SR, 28 in chronic AF) thin muscle preparations (diameter<0.7 mm) were isolated. Isometric force of contraction was measured in the presence of different concentrations of Ca(2+) and isoprenaline. To assess the function of the sarcoplasmic reticulum, the force-frequency relationship and the post-rest potentiation were studied. The myocardial density of the ryanodine-sensitive calcium release channel (CRC) of the sarcoplasmic reticulum was determined by [3H]ryanodine binding. Myocardial content of SR-Ca(2+)-ATPase (SERCA), phospholamban (Plb), calsequestrin (Cals) and the Na(+)/Ca(2+)-exchanger (NCX) were analyzed by Western blot analysis. Adenylyl cyclase activity was measured with a radiolabeled bioassay using [32P]ATP as a tracer. RESULTS: In 72 muscle preparations of SR patients contractile force was 10.9+/-1.8 mN/mm(2) compared to 3.3+/-0.9 mN/mm(2) (n=48, P<0.01) in AF patients. The positive inotropic effect of isoprenaline was diminished but the stimulatory effect on relaxation and the adenylyl cyclase were not altered in AF patients. The force-frequency relation and the post-rest potentiation were enhanced in atrial myocardium of AF patients. The protein levels of CRC, SERCA, Plb, and Cals were not different between the two groups. In contrast, the Na(+)/Ca(2+)-exchanger was upregulated by 67% in atria of AF patients. CONCLUSIONS: AF-induced atrial contractile dysfunction is not due to beta-adrenergic desensitization or dysfunction of the sarcoplasmic reticulum and thus is based on different cellular mechanisms than a ventricular tachycardia-induced cardiomyopathy. Instead, downregulation or altered function of the L-type Ca(2+)-channel and an increased Ca(2+) extrusion via the Na(+)/Ca(2+)-exchanger seem to be responsible for the depressed contractility in remodeled atria.

Adenylyl Cyclases↗

Preserved parasympathetic cardiac innervation after atrioventricular node modification: evidence from circle maps of respiratory sinus arrhythmia.

INTRODUCTION: Respiratory sinus arrhythmia (RSA) and heart rate variability (HRV) are parameters of autonomic cardiac innervation. They decrease with age and after atrioventricular nodal modification (AVNM) suggesting vagal denervation in both situations. We hypothesized, however, that AVNM causes only a transient, functional decline in vagal activity, whereas aging causes permanent vagal denervation. A new method of analyzing RSA phase dynamics based on circle maps (CM) can potentially differentiate between both forms of reduced vagal activity. METHODS: In 18 younger and 14 older healthy control subjects 24-hour Holter ECGs were recorded for HRV analysis. Repeated measurements of RSA were acquired during paced breathing (PB). In 16 consecutive patients undergoing AVNM the same measurements were applied before, 1 day and 3 months after the procedure. CM were calculated from consecutive RR intervals and the similarity between different CM quantified by the Kullback information gain (KIG). RESULTS: HRV analysis revealed lower HF bands, LF bands and RSA amplitudes in older vs. younger control subjects. KIG revealed less similarity between younger and older control subjects than within the respective age groups. After AVNM a decrease in HF bands was noted in HRV analysis. Three months after AVNM, HF bands returned to pre-ablation values. CM obtained before and 1 day after AVNM displayed comparable similarity to CM acquired 1 day before and 3 months after ablation. CONCLUSIONS: In contrast to conventional HRV parameters, CM of RSA are not altered by ablation in the posteroseptal space but by aging. Thus, this new method appears to differentiate between transient autonomic modification and chronic denervation.

Adult↗

European clinical experience with a dual chamber single pass sensing and pacing defibrillation lead.

Dual chamber ICDs are increasingly implanted nowadays, mainly to improve discrimination between supraventricular and ventricular arrhythmias but also to maintain AV synchrony in patients with bradycardia. The aim of this study was to investigate a new single pass right ventricular defibrillation lead capable of true bipolar sensing and pacing in the right atrium and integrated bipolar sensing and pacing in the right ventricle. The performance of the lead was evaluated in 57 patients (age 61 +/- 12 years; New York Heart Association 1.9 +/- 0.6, left ventricular ejection fraction 0.38 +/- 0.15) at implant, at prehospital discharge, and during a 1-year follow-up. Sensing and pacing behavior of the lead was evaluated in six different body positions. In four patients, no stable position of the atrial electrode could intraoperatively be found. The intraoperative atrial sensing was 2.3 +/- 1.6 mV and the atrial pacing threshold 0.8 +/- 0.5 V at 0.5 ms. At follow-up, the atrial sensing ranged from 1.5 mV to 2.2 mV and the atrial pacing threshold product from 0.8 to 1.7 V/ms. In 11 patients, an intermittent atrial sensing problem and in 24 patients an atrial pacing dysfunction were observed in at least one body position. In 565 episodes, a sensitivity of 100% and a specificity of 96.5% were found for ventricular arrhythmias. In conclusion, this single pass defibrillation lead performed well as a VDD lead and for dual chamber arrhythmia discrimination. However, loss of atrial capture in 45% of patients preclude its use in patients depending on atrial pacing.

Aged↗

Temporary disturbances of the QT interval precede the onset of ventricular tachyarrhythmias in patients with structural heart diseases.

An increase in sinus rate prior to ventricular tachyarrhythmias has been demonstrated in previous studies. There is no clear data available concerning changes in ventricular de- and repolarization prior to ventricular tachyarrhythmias, especially in patients with structural heart disease. Therefore, the aim of this study was to analyze the QT and QTc interval (Bazett's formula immediately before the onset of ventricular tachyarrhythmias in stored electrograms of patients with ICDs. The study analyzed 228 spontaneous ventricular tachyarrhythmia episodes in 52 patients (mean age 64 +/- 10 years, 49 men, 3 women) and compared them with 146 electrograms of baseline rhythm recorded during regular ICD follow-up. Mean ventricular cycle length (CL), QT interval, and QTc were measured before the onset of ventricular tachyarrhythmia and during baseline rhythm. Prior to ventricular tachyarrhythmias onset, CL was significantly shorter than during baseline rhythm (714 +/- 139 vs 828 +/- 149 ms, P < 0.0001). By contrast, the QT interval (430 +/- 67 ms) and QTc interval (518 +/- 67 ms) were significantly prolonged before the onset of ventricular tachyarrhythmias as compared to baseline rhythm (QT 406 +/- 67 ms, QTc 450 +/- 61 ms; P < 0.0001). CL, QT, and QTc changes were independent of concomitant treatment with antiarrhythmic drugs. Ventricular tachyarrhythmias are preceded by a significant prolongation of the QT and QTc intervals. This phenomenon may represent a greater than normal disparity of repolarization recovery times possibly facilitating the development of ventricular tachyarrhythmias.

Cardiomyopathies↗

Acute effects of cardiac resynchronization therapy on left ventricular Doppler indices in patients with congestive heart failure.

BACKGROUND: Patients with heart failure frequently exhibit intraventricular conduction delays, which contribute to asynchronous contraction patterns and impaired hemodynamic performance. Cardiac resynchronization therapy (CRT) with biventricular (BV) and left ventricular (LV) pacing has been shown to improve both hemodynamic and clinical performance. This study investigated the effects of CRT on LV Doppler indices in these patients. METHODS AND RESULTS: Thirty-two patients with advanced heart failure (New York Heart Association class > or =III, QRS >120 milliseconds, PR interval >150 milliseconds) were studied 4 weeks after implantation of a CRT system. Doppler echocardiography was conducted in 3 separate CRT modes, right ventricular, LV, and BV stimulation at 3 different atrioventricular delays. CRT resulted in significant improvement of Doppler parameters such as filling time (FT, 313 +/- 111 milliseconds at baseline --> 363 +/- 154 milliseconds [BV], P <.05), aortic velocity time integral (AO(VTI) 23.2 +/- 7.4 cm at baseline --> 26.8 +/- 8.8 cm [LV], P <.05), and the myocardial performance index (MPI, 1.21 +/- 0.51 at baseline --> 0.85 +/- 0.34 [BV], P <.05). The most improvement was observed with LV and BV stimulation at short and intermediate atrioventricular delays (80-120 milliseconds), independent of ischemic or idiopathic origin. CONCLUSIONS: CRT improves hemodynamic performance in patients with heart failure with intraventricular conduction delays. Doppler echocardiography allows noninvasive evaluation of acute CRT effects in patients with heart failure. In particular, FT, AO(VTI), and MPI are useful parameters for noninvasive follow-up and optimization of pacing parameters.

Analysis of Variance↗