Search PubMed⌕ Search

Biomedical subjects

Christoph R Becker

Publications and source records attributed to Christoph R Becker.

At least 19 recordsLinked to original sources

ECG-gated 64-MDCT angiography in the differential diagnosis of acute chest pain.

OBJECTIVE: The most important differential diagnoses of acute chest pain include myocardial infarction, aortic dissection, and pulmonary embolism. The purpose of this study was to evaluate the diagnostic value of an ECG-gated 64-MDCT angiography protocol for simultaneous assessment of the pulmonary arteries, coronary arteries, and aorta within a single breath-hold. SUBJECTS AND METHODS: In 55 patients with acute chest pain, ECG-gated CT angiography was performed with a CT system in which 64 slices per gantry rotation were acquired. Density measurement and visual assessment of motion artifacts were performed to evaluate image quality. CT findings were correlated with results of laboratory tests and clinical follow-up. For 20 patients, two independent blinded reviewers compared findings on CT angiography with those on X-ray coronary angiography. RESULTS: Adequate contrast enhancement of the pulmonary vessels, coronary arteries, and aorta was achieved in all cases. Regarding image quality of the coronary arteries, there was minor blurring in seven patients, and in one examination the images did not provide enough information for diagnosis. The average image quality rating was 1.2 on a scale in which 1 indicated no artifacts; 2, minor motion artifacts; and 3, image insufficient for diagnosis. The cause of chest pain was correctly identified with MDCT in 37 patients. The diagnoses included pulmonary embolism (n = 10), coronary stenosis (n = 9), and aortic dissection (n = 1). In four patients, additional diagnoses were found with other examinations. CONCLUSION: With current techniques, ECG-gated CT angiography of the entire chest has very good image quality. The protocol proved helpful in the differential diagnosis of acute chest pain.

Acute Disease↗

Visual and automatic grading of coronary artery stenoses with 64-slice CT angiography in reference to invasive angiography.

The aim of this study was to assess the performance of a software tool for quantitative coronary artery analysis of computed tomography coronary angiography (CT-QCA) in comparison with invasive coronary angiography with quantitative analysis (CAG-QCA) as standard of reference. Two radiologists reviewed the CT angiography data sets (Siemens Sensation 64) of 25 patients, grading coronary artery stenoses visually and with a software tool (Circulation, Siemens). Twenty-three data sets with sufficient image quality were included in the final analysis. CAG revealed a total of 30 wall irregularities and 28 stenoses, of which 17 were graded as moderate and nine as hemodynamically significant. CT-QCA showed a better agreement to CAG-QCA, with a systematic overestimation of the degree of stenosis of 6.1% and limits of agreement of +36.1% and -23.9; the correlation coefficient was 0.82 (p < 0.0001). Using CT-QCA, sensitivity, specificity, and positive and negative predictive value were 89%, 100%, 89%, and 100%, respectively, for significant area stenoses greater than 75%. The positive predictive value for the visual assessment amounted to 53%. Interobserver variability between CT-QCA and visual assessment showed a kappa value of 0.72. In conclusion, software-supported CT-QCA makes it possible to quantify significant coronary artery stenoses automatically, with good agreement to CAG-QCA.

Contrast Media↗

Material differentiation by dual energy CT: initial experience.

The aim of this study was to assess the feasibility of a differentiation of iodine from other materials and of different body tissues using dual energy CT. Ten patients were scanned on a SOMATOM Definition Dual Source CT (DSCT; Siemens, Forchheim, Germany) system in dual energy mode at tube voltages of 140 and 80 kVp and a ratio of 1:3 between tube currents. Weighted CT Dose Index ranged between 7 and 8 mGy, remaining markedly below reference dose values for the respective body regions. Image post-processing with three-material decomposition was applied to differentiate iodine or collagen from other tissue. The results showed that a differentiation and depiction of contrast material distribution is possible in the brain, the lung, the liver and the kidneys with or without the underlying tissue of the organ. In angiographies, bone structures can be removed from the dataset to ease the evaluation of the vessels. The differentiation of collagen makes it possible to depict tendons and ligaments. Dual energy CT offers a more specific tissue characterization in CT and can improve the assessment of vascular disease. Further studies are required to draw conclusions on the diagnostic value of the individual applications.

Algorithms↗

Screening for bone metastases: whole-body MRI using a 32-channel system versus dual-modality PET-CT.

The diagnostic accuracy of screening for bone metastases was evaluated using whole-body magnetic resonance imaging (WB-MRI) compared with combined fluorodeoxyglucose (FDG) positron emission tomography (PET) and computed tomography (CT) (FDG-PET-CT). In a prospective, blinded study, 30 consecutive patients (18 female, 12 male; 24-76 years) with different oncological diseases and suspected skeletal metastases underwent FDG-PET-CT as well as WB-MRI with the use of parallel imaging (PAT). With a 32-channel scanner, coronal imaging of the entire body and sagittal imaging of the complete spine was performed using T1-weighted and short tau inversion recovery (STIR) sequences in combination. PET-CT was conducted using a low-dose CT for attenuation correction, a PET-emission scan and diagnostic contrast-enhanced CT scan covering the thorax, abdomen and pelvis. Two radiologists read the MRI scans, another radiologist in combination with a nuclear medicine physician read the PET-CT scans, each in consensus. The standard of reference was constituted by radiological follow-up within at least 6 months. In 28 patients, 102 malignant and 25 benign bone lesions were detected and confirmed. WB-MRI showed a sensitivity of 94% (96/102), PET-CT exams achieved 78% (79/102; P<0.001). Specificities were 76% (19/25) for WB-MRI and 80% (20/25) for PET-CT (P>0.05). Diagnostic accuracy was 91% (115/127) and 78% (99/127; P<0.001), respectively. Cut-off size for the detection of malignant bone lesions was 2 mm for WB-MRI and 5 mm for PET-CT. WB-MRI revealed ten additional bone metastases due to the larger field of view. In conclusion, WB-MRI and FDG-PET-CT are robust imaging modalities for a systemic screening for metastatic bone disease. PAT allows WB-MRI bone marrow screening at high spatial resolution and with a diagnostic accuracy superior to PET-CT.

Adult↗

Dual-source CT cardiac imaging: initial experience.

The relation of heart rate and image quality in the depiction of coronary arteries, heart valves and myocardium was assessed on a dual-source computed tomography system (DSCT). Coronary CT angiography was performed on a DSCT (Somatom Definition, Siemens) with high concentration contrast media (Iopromide, Ultravist 370, Schering) in 24 patients with heart rates between 44 and 92 beats per minute. Images were reconstructed over the whole cardiac cycle in 10% steps. Two readers independently assessed the image quality with regard to the diagnostic evaluation of right and left coronary artery, heart valves and left ventricular myocardium for the assessment of vessel wall changes, coronary stenoses, valve morphology and function and ventricular function on a three point grading scale. The image quality ratings at the optimal reconstruction interval were 1.24+/-0.42 for the right and 1.09+/-0.27 for the left coronary artery. A reconstruction of diagnostic systolic and diastolic images is possible for a wide range of heart rates, allowing also a functional evaluation of valves and myocardium. Dual-source CT offers very robust diagnostic image quality in a wide range of heart rates. The high temporal resolution now also makes a functional evaluation of the heart valves and myocardium possible.

Algorithms↗

Strategies to reduce the risk of contrast-induced nephropathy.

In view of the clinical importance of contrast-induced nephropathy (CIN), numerous potential risk-reduction strategies have been evaluated. Adequate intravenous volume expansion with isotonic crystalloid (1.0-1.5 mL/kg per hr) for 3-12 hours before the procedure and continued for 6-24 hours afterward can lessen the probability of CIN in patients at risk. There are insufficient data on oral fluids (as opposed to intravenous volume expansion) as a CIN-prevention strategy. No adjunctive medical or mechanical treatment has been proved to be efficacious in reducing risk for CIN. Prophylactic hemodialysis and hemofiltration have not been validated as effective strategies. The CIN Consensus Working Panel considered that, of the pharmacologic agents that have been evaluated, theophylline, 3-hydroxy-3-methylglutaryl coenzyme A reductase inhibitors (statins), ascorbic acid, and prostaglandin E(1) deserve further evaluation. N-acetylcysteine is not consistently effective in reducing the risk for CIN. Fenoldopam, dopamine, calcium channel blockers, atrial natriuretic peptide, and l-arginine have not been shown to be effective. Use of furosemide, mannitol, or an endothelin receptor antagonist is potentially detrimental. Nephrotoxic drugs should be withdrawn before contrast administration in patients at risk for CIN.

Acute Kidney Injury↗

High-resolution ex vivo imaging of coronary artery stents using 64-slice computed tomography--initial experience.

The aim of the study was to evaluate the potential of new-generation multi-slice computed tomography (CT) scanner technology for the delineation of coronary artery stents in an ex vivo setting. Nine stents of various diameters (seven stents 3 mm, two stents 2.5 mm) were implanted into the coronary arteries of ex vivo porcine hearts and filled with a mixture of an iodine-containing contrast agent. Specimens were scanned with a 16-slice CT (16SCT) machine; (Somatom Sensation 16, Siemens Medical Solutions), slice thickness 0.75 mm, and a 64-slice CT (64SCT, Somatom Sensation 64), slice-thickness 0.6 mm. Stent diameters as well as contrast densities were measured, on both the 16SCT and 64SCT images. No significant differences of CT densities were observed between the 16SCT and 64SCT images outside the stent lumen: 265+/-25HU and 254+/-16HU (P=0.33), respectively. CT densities derived from the 64SCT images and 16SCT images within the stent lumen were 367+/-36HU versus 402+/-28HU, P<0.05, respectively. Inner and outer stent diameters as measured from 16SCT and 64SCT images were 2.68+/-0.08 mm versus 2.81+/-0.07 mm and 3.29+/-0.06 mm versus 3.18+/-0.07 mm (P<0.05), respectively. The new 64SCT scanner proved to be superior in the ex vivo assessment of coronary artery stents to the conventional 16SCT machine. Increased spatial resolution allows for improved assessment of the coronary artery stent lumen.

Animals↗

Contrast medium use.

Various properties of iodinated contrast media (osmolality, ionic versus nonionic, and viscosity) may contribute to contrast-induced nephropathy (CIN). Therefore, the choice of contrast medium affects the risk for CIN. There is good evidence that low-osmolar contrast media are less nephrotoxic than high-osmolar contrast media in patients at increased risk for CIN who receive intra-arterial iodinated contrast. Current evidence suggests that nonionic isosmolar contrast presents the lowest risk for CIN in patients with chronic kidney disease (CKD), particularly in those patients with diabetes mellitus. Intra-arterial administration of contrast media may be associated with a greater risk for CIN above that observed with intravenous administration. The use of gadolinium or CO(2) as alternative contrast media to avoid the risk of nephrotoxicity cannot be substantiated by clinical trials and therefore cannot be recommended. Most studies show that, within a class, higher volumes (>100 mL) of iodinated contrast medium are associated with a higher risk for CIN. However, in patients at high risk, such as those with CKD and diabetes, even small volumes of contrast medium can have adverse effects on renal function.

Acute Kidney Injury↗

Risk prediction of contrast-induced nephropathy.

In order to make appropriate decisions about clinical management, it is important for physicians to be able to stratify patients according to their risk for contrast-induced nephropathy (CIN). The most important risk marker for nephropathy after exposure to iodinated contrast media is preexisting renal impairment. The risk of CIN is elevated and becomes clinically important in patients with chronic kidney disease characterized by an estimated glomerular filtration rate <60 mL/min per 1.73 m(2). In patients with renal impairment, diabetes mellitus amplifies the risk of CIN and complicates postprocedure management. Other markers associated with an increased risk of CIN include cardiovascular disease, periprocedural hemodynamic instability, use of nephrotoxic drugs, and anemia. The effect of risk factors is additive, and the presence of multiple risk factors in the same patient can create a very high risk for CIN and acute renal failure requiring dialysis. Risk models incorporating baseline and periprocedural characteristics have been developed using data from large databases of percutaneous coronary intervention patients. These schemes are potentially valuable, but at present the most practical approach to risk prediction is based on a simple model incorporating renal function and diabetes mellitus.

Cardiovascular Diseases↗

Baseline renal function screening.

Renal impairment at baseline (estimated glomerular filtration rate [eGFR] <60 mL/min/1.73 m(2)) is the most important risk marker to predict the risk of contrast-induced nephropathy (CIN) in patients receiving iodinated contrast media. Hence, it is important to assess renal function before administration of contrast medium to ensure that appropriate steps are taken to reduce the risk. Serum creatinine alone does not provide a reliable measure of renal function, hence the National Kidney Foundation Kidney Disease Outcome Quality Initiative (K/DOQI) recommends that clinicians should use an eGFR calculated from the serum creatinine as an index of renal function. The CIN Consensus Working Panel agreed that eGFR should be determined before contrast administration, using the abbreviated Modification of Diet in Renal Disease (MDRD) formula, recommended by K/DOQI as the preferred equation for the calculation of eGFR in adults. Where a serum creatinine measurement or eGFR is not available, a simple survey or questionnaire can be used before contrast agent administration to identify patients at higher risk for CIN compared with the general population. In emergency situations, where the benefit of very early imaging outweighs the risk of waiting, the CIN Consensus Working Panel agreed that the procedure can be performed without assessment of renal function.

Consensus Statements as Topic↗

High-risk situations and procedures.

With the wider use of imaging and interventional techniques that require the use of iodinated contrast media in seriously ill patients, many clinical situations occur where patients may be at increased risk for contrast-induced nephropathy (CIN). There is little guidance for clinicians in these areas. The aim of this review is to assess the available literature. Acute renal failure is a common complication following coronary artery bypass surgery, and exposure to contrast medium may increase the risk for this condition, although there is insufficient evidence to make a definitive statement. Evidence is also limited for patients with liver disease: in those undergoing transarterial chemoembolization, cirrhosis may be a risk factor for renal failure. There is some evidence that periprocedural hypotension may be a risk factor for CIN after percutaneous coronary intervention, but no published information was identified on the significance of shock or hypotension in other groups of patients. The published evidence on the risk of CIN in renal transplant recipients is inconsistent. In emergency situations, the course of action is usually dictated by clinical circumstances; the renal status of a patient is likely to be unknown and it is important to ensure adequate volume expansion, especially after the procedure. In all clinical situations that are potentially associated with a high risk for CIN, the decision to administer contrast medium is a matter for clinical judgment, based on the clinical status of the patient and the expected benefits of the investigation or procedure.

Acute Kidney Injury↗

Pathophysiology of contrast-induced nephropathy.

Contrast-induced nephropathy (CIN) is the third leading cause of acute kidney injury in hospitalized patients and is associated with significant patient morbidity. The pathogenesis of CIN is complex and not fully understood, but iodinated contrast agents induce intense and prolonged vasoconstriction at the corticomedullary junction of the kidney. Moreover, high-osmolar dyes directly impair the autoregulatory capacity of the kidney through a loss of nitric oxide production. These effects, coupled with direct tubular toxicity of contrast media, lead to overt acute tubular necrosis and the syndrome of CIN.

Acute Kidney Injury↗

Epidemiology and prognostic implications of contrast-induced nephropathy.

Contrast-induced nephropathy (CIN), usually defined as an increase in serum creatinine of 0.5 mg/dL (44.2 mumol/L), or a 25% increase from the baseline value 48 hours after the procedure, is a common and potentially serious complication of the use of iodinated contrast media in patients at risk of acute renal injury. It is an important cause of hospital-acquired renal failure, responsible for approximately 11% of cases. CIN may be difficult to distinguish from cholesterol embolization, another cause of postprocedure renal impairment. The reported incidence of CIN varies depending on the patient population studied. The impact of postprocedural renal impairment on clinical outcomes has been evaluated most extensively in patients undergoing percutaneous coronary intervention. CIN is associated with increased mortality both in hospital and at 1 year. A higher incidence of in-hospital and late cardiovascular events, as well as longer hospital stays, has been reported in patients developing CIN. In a small proportion of patients, CIN is severe enough to require dialysis, and these patients have a particularly poor prognosis. Many of the risk markers for CIN are also predictive of a worse prognosis.

Acute Kidney Injury↗

Accuracy of 64-slice computed tomography to classify and quantify plaque volumes in the proximal coronary system: a comparative study using intravascular ultrasound.

OBJECTIVES: We evaluated the accuracy of a new 64-slice computed tomography (CT) scanner, compared with intravascular ultrasound, to visualize atherosclerosis in the proximal coronary system. BACKGROUND: Noninvasive determination of plaque composition and plaque burden may be important to improve risk stratification. METHODS: In 20 patients, a 64-slice CT scan (Sensation 64, Siemens Medical Solutions, Forchheim, Germany) and an intravascular ultrasound investigation of vessels without stenosis >50% was performed. Diagnostic image quality with 64-slice CT was obtained in 36 vessels in 19 patients. RESULTS: In these vessels, which were divided in 3-mm sections, 64-slice CT enabled a correct detection of plaque in 54 of 65 (83%) sections containing noncalcified plaques, 50 of 53 (94%) sections containing mixed plaques, and 41 of 43 (95%) sections containing calcified plaques. In 192 of 204 (94%) sections, atherosclerotic lesions were excluded correctly. In addition, 64-slice CT enabled the visualization of 7 of 10 (70%) sections revealing a lipid pool and could identify a spotty calcification pattern in 27 of 30 (90%) sections. The correlation coefficient to determine plaque volumes per vessel was r2 = 0.69 (p < 0.001) with an underestimation of mixed and noncalcified plaque volumes (p < 0.03) and a trend to overestimate calcified plaque volumes by 64-slice CT. The interobserver variability to determine plaque volumes was 37%. Interobserver agreement to identify atherosclerotic sections was good (Cohen's kappa coefficient = 0.75). CONCLUSIONS: We conclude that 64-slice CT reveals encouraging results to noninvasively detect different types of coronary plaques located in the proximal coronary system. The ability to determine plaque burden currently is hampered by mainly an insufficient reproducibility.

Coronary Angiography↗

Assessment of coronary artery stent patency and restenosis using 64-slice computed tomography.

RATIONALE AND OBJECTIVES: Restenosis remains a major limitation of coronary catheter-based stent placement. Therefore, a reliable noninvasive diagnostic method for the evaluation of stented coronary arteries would be highly desirable. Our aim was to evaluate the diagnostic accuracy of high-resolution 64-slice computed tomography (64SCT) in a pilot study for the assessment of the lumen of coronary artery stents. MATERIALS AND METHODS: Twenty-five patients underwent 64SCT of the coronary arteries and quantitative x-ray coronary angiography (QCA) after coronary artery stent placement. 64SCT coronary angiography was performed with the following parameters: spatial resolution = 0.4 x 0.4 x 0.4 mm; temporal resolution = 83-165 milliseconds; contrast agent = 80 mL at a flow rate of 5 mL/second; retrospective electrocardiogram gating. The 64SCT scans were evaluated for image quality and for the presence of significant in-stent and peri-stent (proximal and distal) stenoses. Determinations were made of the sensitivity, specificity, diagnostic accuracy, and positive and negative predictive values (PPV and NPV) of 64SCT for the detection or exclusion of stenoses. RESULTS: A total of 46 stents were evaluated, of which 45 (98%) were of diagnostic image quality. Significant in-stent restenosis or occlusion was detected on QCA in 8/45 cases (>/=50% stenosis = 6; occlusion = 2). The sensitivity, specificity, accuracy, PPV, and NPV of 64SCT for the detection of significant in-stent disease was 75%, 92%, 89%, 67%, and 94%, respectively. Both occluded coronary artery stents were correctly identified. The sensitivity, specificity, and accuracy values of 64SCT for the detection of significant proximal peri-stent stenoses were 75%, 95%, and 93%, respectively, whereas the values for detection of significant distal peri-stent stenoses were 67%, 85%, and 84%, respectively. CONCLUSION: The high spatial and temporal resolution of 64SCT may permit improved assessment of stent occlusion and peri-stent disease, although detection of in-stent stenosis remains difficult.

Adult↗

Image quality, motion artifacts, and reconstruction timing of 64-slice coronary computed tomography angiography with 0.33-second rotation speed.

OBJECTIVES: We sought to evaluate the impact of patients' heart rate (HR) on coronary CTA image quality (IQ) and motion artifacts using a 64-slice scanner with 0.33/360 degrees rotation. MATERIALS AND METHODS: Coronary CTA data sets of 32 patients (HR 65 bpm to 75 bpm, n = 7) examined on a 64-slice scanner (Sensation 64, Siemens Medical Solutions, Forchheim, Germany) with 0.33s/360 degrees gantry rotation speed were analyzed. All patients had suspicion of coronary artery disease. Data acquisition was performed using 64 x 0.6-mm collimation, and contrast enhancement was provided by injection of 80 mL of iopromide (5 mL/s + NaCl). Images were reconstructed throughout the RR interval using half-scan and dual-segment reconstruction. IQ was rated by 2 observers using a 3-point scale from excellent (1) to nondiagnostic (3) for coronary segments. Quality was correlated to the HR, time point of optimal IQ analyzed, and the benefit of dual-segment reconstruction evaluated. RESULTS: Overall mean IQ was 1.31 +/- 0.32 for all HR, with IQ being 1.08 +/- 0.12 for HR 65 bpm 75 bpm (P = 0.0003). Dual-segment reconstruction did not significantly improve IQ in any HR group (P = NS). Mean IQ was significantly better for LAD than for RCA (P < 0.0001) and LCX (P < 0.01). A total of 3.5% (11/318) of coronary artery segments were rated nondiagnostic by at least one reader based on motion artifacts. Although in HR < 65 bpm, the best IQ was predominately in diastole (93%), in HR > 75 bpm, the best IQ shifted to systole in most cases (86%). CONCLUSIONS: Temporal resolution at 0.33-second rotation allows for diagnostic IQ within a wide range of HR using half-scan reconstruction. With increasing HR the time point of best IQ shifts from mid-diastole to systole.

Adult↗

Contrast bolus optimization for cardiac 16-slice computed tomography: comparison of contrast medium formulations containing 300 and 400 milligrams of iodine per milliliter.

OBJECTIVES: The aims of our study were to compare contrast injection protocols with contrast media containing 300 and 400 mg iodine per milliliter for optimal contrast enhancement in cardiac multidector row computed tomography (CT) and to evaluate the correlation of test bolus curve parameters with the final contrast density of the main bolus. MATERIALS AND METHODS: Sixty patients with known or suspected coronary artery disease were included in a prospective double-blind study. Patients were randomized to 2 groups. Group 1 received 83 mL of a contrast medium (CM) containing 300 mg of iodine (Iomeron 300, Bracco Imaging SpA, Milan, Italy) at a flow rate of 3.3 mL/s, whereas group 2 received 63 mL of the same agent containing 400 mg of iodine (Iomeron 400) at a flow rate of 2.5 mL/s. The test bolus volumes were 20 mL and 15 mL, respectively. Imaging was performed using a 16-slice CT system (16DCT; Somatom Sensation 16, Siemens Medical Solutions, Forchheim, Germany). Contrast densities (Hounsfield Units [HU]) were determined in the cardiac chambers and in the main coronary arteries. The peak density and area under the curve of the test bolus were calculated for each patient. RESULTS: The mean contrast densities of the coronary arteries were 259.1 +/- 46.7 HU for group 1 and 251.6 +/- 51.0 HU, for group 2. No noteworthy differences between groups were noted for density measurements in the cardiac chambers or for the ratio of right-to-left ventricle density. Whereas a positive correlation was noted for both groups between the area under the curve of the test bolus and the mean density of the main bolus, a positive correlation between peak density of the test bolus and mean density of the main bolus was noted only for group 1. CONCLUSION: Equivalent homogenous enhancement of the ventricular cavities and coronary arteries to that obtained using a CM with standard iodine concentration (Iomeron 300) can be achieved with lower overall volumes of administered CM and reduced injection flow rates when a CM with high iodine concentration (Iomeron 400) is used.

Adult↗