Search PubMed⌕ Search

Biomedical subjects

C Gianturco

Publications and source records attributed to C Gianturco.

59 records · Page 4Linked to original sources

Occlusive effect of metallic stents on canine ureters.

A three-part study, with successive modifications based on preceding results, was conducted to evaluate ureteral placement of metallic stents. Gianturco self-expanding (10 mm and 4 mm diameter) and balloon-expanded (4 mm diameter) metallic stents were placed in normal and stenotic canine ureters. No migration or ureteral perforation occurred during the follow-up of 10 mm stents. Varying degrees of hydronephrosis and hydroureter were found on all 1-week pyelograms. At 4 weeks, complete occlusion of the stented ureter was noted in all cases because of mucosal hyperplasia around the stent wires. To prevent this reaction, 4 mm self-expanding stents constructed of smaller wire that was uncoated or coated with either Teflon or poly-urethane were tested in five dogs. In all cases, results were similar to those obtained with the larger prostheses. Finally, 4 mm balloon-expanded stents were placed in a normal ureter of three dogs. In one dog, the stent migrated out of the ureter. No migration or ureteral perforation occurred in the two remaining dogs. In these animals, mucosal hyperplasia and complete ureteral occlusion occurred 6 and 8 weeks after placement. Therefore, ureteral placement of Gianturco self-expanding as well as balloon-expanded metallic stents leads to occlusion of the ureter instead of maintaining its patency. Stents, therefore, may be useful as ureteral occlusion devices.

Animals↗

Treatment of experimentally induced atherosclerosis in swine iliac arteries: a comparison of self-expanding and balloon-expanded stents.

Atherosclerosis was induced in 20 Hanford miniature swine. Subsequently, one iliac artery lesion in each of 16 pigs was stented with either a self-expanding (8 pigs) or a balloon-expanded (8 pigs) stent. Immediately after stent placement, 4 animals in each group were taken off the atherogenic diet and continued on normal chow for the remainder of the study. Four months after stents were placed, atherosclerosis and the mural changes associated with the stent were more clearly evident in the arteries of the pigs continued on the atherogenic diet. These pigs also exhibited significantly more neointimal proliferation. In addition, the arteries containing the balloon-expanded stents showed more extensive and complex intimal changes when compared with arteries with self-expanding stents. Although both stent designs were equally effective in maintaining vascular patency, the balloon-expanded stent was more traumatic to the vessel wall which resulted in a significantly greater neointimal thickness.

Animals↗

Placement of covered self-expanding metallic stents in the common bile duct: a feasibility study.

PURPOSE: Gianturco self-expanding metallic stents have been useful in cases of benign biliary stenoses; however, the stents have not worked well in the presence of intraluminal tumor because of tumor growth between the wire struts. Stents were covered with polymeric membranes, which may prevent tumor ingrowth, and the feasibility of using these covered stents in the common bile duct was studied in healthy adult dogs. MATERIALS AND METHODS: Initially, stents (10 x 6 mm) covered with polycaprolactone (PCL), segmented polyether polyurethane (SPP), and silicone were placed in the common bile duct of dogs and were followed up for 3-12 months. Subsequently, four types of modified silicone-covered stents were evaluated. Rough-surface, small-diameter (3-mm), half-covered, and tapered stents were placed and followed up for 3 months. RESULTS: In the initial study, the SPP and silicone membranes remained intact, but the PCL covering broke in all dogs. In all but two dogs, luminal narrowing caused by varying degrees of papillary mucosal hyperplasia at both ends of the stent was observed. In the subsequent study, mucosal hyperplasia was considerably reduced by using half-covered stents and was virtually eliminated with tapered stents. All small-diameter stents migrated into the bowel. CONCLUSION: These studies suggest that tapered Gianturco self-expanding stents covered with silicone may be useful in the biliary tract in cases of intraluminal tumor.

Animals↗

Experimental transcatheter intraarterial infusion-occlusion chemotherapy.

Dogs were used to develop transcatheter vascular techniques to improve local tissue accumulation of a radiolabeled chemotherapeutic agent. A double lumen balloon catheter was used for short term (10 minute) intraarterial infusions of 14C labeled Fluorouracil (5-FU) during temporary vascular occlusion with the balloon. Local tissue (hind limb musculature) as well as venous blood concentrations of 5-FU draining the area of infusion were compared to those obtained following intraarterial infusion alone or following intravenous administration of the drug. Combining intraarterial infusion with temporary vascular occlusion increased (7 to 9 times) the local tissue concentration of the 5-FU when compared to intraarterial infusion alone. The local tissue levels of the drug during intraarterial infusion and temporary vascular occlusion were 30 to 50 times greater than those obtained by intravenous administration. Levels of 5-FU were also significantly higher in the venous blood draining the infusion area when the combined intraarterial infusion-occlusion technique was employed.

Animals↗