Endovascular treatment of a noninfected anastomotic juxtarenal aortic aneurysm.

An 82-year-old man underwent an endovascular procedure with a commercially available endovascular graft for an anastomotic juxtarenal abdominal aortic aneurysm. The anastomotic aneurysm, which showed no sign of infection, developed 4 years after implantation of an aortic end-to-end graft for an infrarenal aortic aneurysm. The aneurysm was diagnosed during routine ultrasonographic follow-up; there was no apparent infection of the graft. Aortography confirmed the diagnosis and also revealed a small pseudoaneurysm at the level of the distal aortic anastomosis. Endovascular surgery was performed in the operating room with the guidance of C-arm fluoroscopy and intravascular ultrasound. Two Vanguard Straight Endovascular Aortic Graft Cuffs (26 x 50 mm and 24 x 50 mm) were implanted, successfully excluding both the anastomotic juxtarenal aortic aneurysm and the distal pseudoaneurysm. The renal arteries were preserved and no early or late endoleaks were observed. The patient was discharged 2 days after the procedure. Sixteen months later, he was alive and well, with no endovascular leakage, no enlargement of the aortic aneurysms, and no sign of infection. In our opinion, this experience shows that commercially available endovascular grafts may be used successfully to treat anastomotic aortic aneurysms and pseudoaneurysms.

Aged↗

Comparison of immediate and follow-up results of the short and long NIR stent with the Palmaz-Schatz stent.

The intrinsic characteristics of a stent including stent length may affect both procedural success and long-term outcome. The present study evaluated the immediate and follow-up results after implantation of the short and long NIR stent and compared these results with the Palmaz-Schatz stent. Between July 1995 and December 1996, stenting with a 16-mm NIR stent (NIR-16), a 32-mm NIR stent (NIR-32), or a Palmaz-Schatz stent (PS) was performed in 68, 57, and 155 lesions, respectively. There were no significant differences in the incidences of delivery failure (PS, 2.6%: NIR-16, 4.4%; NIR-32, 5.3%; p = NS) and procedural success (PS, 92%; NIR-16, 93%; NIR-32, 93%; p = NS) among the 3 groups. The reference vessel diameter was smaller in lesions with a 32-mm NIR stent than in those with a Palmaz-Schatz stent (PS, 3.14+/-0.58, NIR-16, 3.00+/-0.50; NIR-32, 2.90+/-0.47 mm; p <0.05). The lesion length was longer in lesions with a 32-mm NIR stent than in those with a Palmaz-Schatz or a 16-mm NIR stent (PS, 8.9+/-5.0; NIR-16, 11.0+/-4.1; NIR-32, 26.1+/-9.7 mm; p <0.01). After the procedure, the lesions with a 32-mm NIR stent had a smaller minimal lumen diameter than those with a Palmaz-Schatz stent (PS, 3.17+/-0.61; NIR-16, 2.99+/-0.51; NIR-32, 2.89+/-0.49 mm; p <0.01). At follow-up, a smaller minimal lumen diameter was observed in lesions with a 32-mm NIR stent than in those with a Palmaz-Schatz or a 16-mm NIR stent (PS, 2.32+/-0.98; NIR-16, 2.25+/-0.80; NIR-32, 1.68+/-0.79 mm; p <0.01). Restenosis rates were 16.5% in lesions with a Palmaz-Schatz stent, 13.3% in those with a 16-mm NIR stent, and 47.4% in those with a 32-mm NIR stent (p <0.01). Although stent delivery and procedural success of a long NIR stent were acceptable, the restenosis rate of a long NIR stent was high compared with a short NIR stent or a Palmaz-Schatz stent.

Adult↗

Prevention of distal embolization during saphenous vein graft lesion angioplasty. Experience with a new temporary occlusion and aspiration system.

BACKGROUND: Repeat coronary artery bypass graft surgery (CABG) is associated with a high morbidity and mortality, rendering percutaneous treatment of saphenous vein graft (SVG) lesions an attractive alternative. However, percutaneous interventions of degenerated SVGs carries high risk of distal embolization. METHODS AND RESULTS: This study reports our initial experience with the PercuSurge GuardWire, a new device developed to prevent embolization during treatment of degenerated SVG. This device consists of a 190-cm-long, hollow 0.014-in guidewire with a central lumen connected to a distal occlusion balloon. A dedicated inflation device (the MicroSeal Adapter) was used to inflate the distal balloon and maintain complete lumen occlusion during balloon dilatation and stent implantation. A monorail aspiration catheter, connected to a vacuum syringe, was used to evacuate atherosclerotic and thrombotic debris. Angioplasty with stent implantation was performed in 15 degenerated SVGs (18 lesions). Procedural success was achieved in all patients with normal postprocedure flow (Thrombolysis in Myocardial Infarction grade 3). No distal embolization was observed. There were no major in-hospital adverse clinical events, including Q-wave or non-Q-wave myocardial infarction, emergency CABG, or death. All patients were asymptomatic at discharge. CONCLUSIONS: This preliminary series supports the feasible use of the PercuSurge GuardWire for retrieval of plaque debris and prevention of embolization in degenerated SVGs. The good tolerance of temporary occlusions without angiographic or clinical evidence of distal embolization represents encouraging early findings.

Aged↗

Does the specific intravascular ultrasound criterion used to optimize stent expansion have an impact on the probability of stent restenosis?

Intravascular ultrasound (IVUS) imaging has been used to optimize stent implantation in coronary arteries, but the criteria used were chosen on an empiric basis. The aim of this study was to determine whether any of these criteria have an independent role in predicting the probability of freedom from restenosis. The study population consisted of 425 patients (496 lesions) who underwent angiographically successful IVUS-guided stenting. Five IVUS criteria were studied: (1) intrastent minimal lumen cross-sectional area (ISMLCSA) > or =9 mm2; (2) ISMLCSA (> or =9 mm2 and > or =80% of average reference lumen cross-sectional area [CSA]); (3) ISMLCSA > or =90% of average reference lumen CSA; (4) ISMLCSA > or =90% of distal reference lumen CSA; and (5) ISMLCSA > or =55% of average reference vessel CSA. These criteria were met in 33%, 29%, 68%, 82%, and 69% of lesions, respectively. Angiographic follow-up was performed in 335 of 421 eligible patients (80%) at 5.3 +/- 2.7 months. An absolute ISMLCSA > or =9 mm2 was associated with the lowest restenosis, but this criterion was primarily achieved in large vessels. The only criterion that was associated with higher probability of freedom from restenosis independently from vessel size was an ISMLCSA > or =55% of average reference vessel CSA. Therefore, when IVUS is used to guide stent implantation an effort should be made to achieve the largest lumen safely possible. An ISMLCSA > or =55% of the average reference vessel CSA seems to be the most appropriate criterion in terms of frequency of achievement and in terms of increasing the probability of freedom from restenosis.

Coronary Angiography↗

In-stent neointimal proliferation correlates with the amount of residual plaque burden outside the stent: an intravascular ultrasound study.

BACKGROUND: The aim of this study was to evaluate the relationship between residual plaque burden after coronary stent implantation and the development of late in-stent neointimal proliferation. METHODS AND RESULTS: Between January 1996 and May 1997, 50 patients underwent intravascular ultrasound (IVUS) interrogation at 6+/-1.2 months after coronary stent implantation in native coronary arteries. IVUS images were acquired with a motorized pullback, and cross-sectional measurements were performed within the stents at 1-mm intervals. The following measurements were obtained: (1) lumen area (LA), (2) stent area (SA), (3) area delimited by the external elastic membrane (EEMA), (4) percent neointimal area calculated as (SA-LA/SA)x100, and (5) percent residual plaque area calculated as (EEMA-SA)/EEMAx100. Volume measurements within the stented segments were calculated by applying Simpson's rule. In the pooled data analysis of 876 cross sections, linear regression showed a significant positive correlation between percent residual plaque area and percent neointimal area (r=0.50, y= 45.03+0.29x, P<0.01). There was significant incremental increase in mean percent neointimal area for stepwise increase in percent residual plaque area. Mean percent neointimal area was 16.3+/-10.3% for lesions with a percent residual plaque area of <50% and 27.7+/-11% for lesions with a percent residual plaque area of >/=50% (P<0.001). The volumetric analysis showed that the percent residual plaque volume was significantly greater in restenotic lesions compared with nonrestenotic lesions (58.7+/-4.3% versus 51.4+/-5.7%, respectively; P<0.01). CONCLUSIONS: Late in-stent neointimal proliferation has a direct correlation with the amount of residual plaque burden after coronary stent implantation, supporting the hypothesis that plaque removal before stent implantation may reduce restenosis.

Aged↗

Lower restenosis rate with stenting following aggressive versus less aggressive rotational atherectomy.

The present study evaluated the acute and follow-up results of stenting following aggressive rotational atherectomy compared with stenting following less aggressive rotational atherectomy. Recent work has demonstrated that stenting following rotational atherectomy is a promising strategy for complex and calcified lesions. However, there is little information available regarding the optimal procedural technique of rotational atherectomy to be employed before stent implantation. Between May 1995 and February 1997, 162 lesions in 126 patients were stented following rotational atherectomy because of the presence of severe calcification on fluoroscopy or intravascular ultrasound (95%). The lesions were divided as to whether aggressive rotational atherectomy was performed or not. Aggressive rotational atherectomy, defined as the use of a final burr size > or =2.25 mm and/or final burr/vessel ratio > or =0.8, was performed in 56 lesions. A less aggressive rotational atherectomy strategy was performed in 106 lesions. Procedural Q-wave (8.9% vs. 1.9%, P<0.05) and non-Q-wave (11% vs. 1.9%, P<0.05) myocardial infarctions were observed more frequently after aggressive rotational atherectomy; there was no significant difference in the incidence of other procedural complications. Although there was no significant difference in minimal lumen diameter after the procedure (3.11+/-0.68 vs. 2.99+/-0.48 mm, NS), at follow-up a greater minimal lumen diameter was observed in the lesions treated with aggressive rotational atherectomy compared to those treated with less aggressive rotational atherectomy (2.12+/-1.31 vs. 1.56+/-0.89 mm, P<0.01). Restenosis rates were 50.0% in the lesions treated without aggressive rotational atherectomy and 30.9% in those treated with aggressive rotational atherectomy (P<0.05). There was no significant difference in the incidence of restenosis with a focal pattern between the two groups (25.0% vs. 21.4%, NS). In contrast, restenosis with a diffuse pattern was lower in lesions treated with aggressive rotational atherectomy than in those without aggressive rotational atherectomy (9.5% vs. 25.0%, P<0.05). Aggressive rotational atherectomy followed by stenting is a promising strategy to reduce the restenosis rate in calcified lesions. However, the aggressive strategy is associated with an increased risk of procedural myocardial infarction.

Calcinosis↗

Treatment of a coronary aneurysm with a new polytetrafluoethylene-coated stent: a case report.

A 43-year-old man underwent implantation of a PTFE-covered stent to exclude an aneurysm in an aorto-coronary venous bypass graft. A successful aneurysm closure was achieved after high-pressure stent expansion and no intimal hyperplasia was observed within the PTFE-covered stent segment in the angiogram performed 9 months later. The technical characteristics and indications of this new coronary prosthesis are discussed based on the authors' recent experience in 63 patients.

Adult↗

Focal wall overstretching after high-pressure coronary stent implantation does not influence restenosis.

To determine if vessel wall overstretching during coronary stenting is associated with a higher restenosis rate, the intravascular ultrasound morphological evaluation was performed following ultrasound criteria. A total of 468 lesions with successful coronary Palmaz-Schatz stenting guided by intravascular ultrasound were classified into the no overstretching group (n = 295) and the overstretching group (n = 147). There were 26 lesions not classifiable due to the poststent morphology. Balloon-to-vessel ratio was 1.12 +/- 0.17 in the no focal overstretching group and 1. 20 +/- 0.20 in the overstretching group (P < 0.0002). Follow-up angiogram was performed in 77% of no focal overstretching group and in 75% of the focal overstretching group. The restenosis rate of the no focal overstretching group was 19.8% and 20.9% in the focal overstretching group, respectively (P = 0.65). Focal overstretching was more frequent following balloon oversizing. No increase in restenosis rate, found in focal overstretched stented lesions, leads us to the hypothesis of a regulation of smooth-muscle-cell proliferation activated by the normalization of blood flow and of shear stress, when stent implantation succeeds in optimally improving the lumen. Cathet. Cardiovasc. Intervent. 48:24-30, 1999.

Coronary Angiography↗

Successful treatment of a bifurcation lesion with the Carina Bard stent: A case report.

In the last years new techniques and user-friendly stents have improved the results of stent implantation in coronary bifurcational lesions but difficulties in stent deployment and incomplete coverage of the bifurcation remain a problem. We describe the case of a proximal lesion of the anterior descending artery involving a large diagonal branch treated with the Carina Bard bifurcate stent, a new device that allows the complete immediate coverage of a bifurcational lesion with a single stent. Cathet. Cardiovasc. Intervent. 48:89-92, 1999.

Coronary Angiography↗

Administration of protamine after coronary stent deployment.

BACKGROUND: Prompt reversal of anticoagulation by protamine administration could be an important therapeutic option to treat serious procedural complications such as vessel rupture or major bleeding from the puncture site during coronary stent implantation. However, this therapeutic option is rarely used because of the possible risk of stent thrombosis. METHODS: We retrospectively analyzed the incidence of acute and subacute stent thrombosis and vascular complications in 90 patients who received protamine (protamine group) and 1763 patients who did not receive protamine (control group) after successful coronary stent implantation. The 2 groups were matched for clinical, angiographic, and procedure characteristics. RESULTS: No patients in the protamine group had adverse effects such as hypotension or vascular collapse during protamine administration. Acute stent thrombosis did not occur in any protamine group patient but did occur in 12 patients in the control group (0.7%) (P =.47). Subacute stent thrombosis occurred in 2 patients in the protamine group (2.1%) and in 15 in the control group (0.8%) (P =.20). By logistic regression analysis, protamine was not a determinant of stent thrombosis. CONCLUSIONS: Reversal of anticoagulation by protamine after stent implantation does not predispose to stent thrombosis. This result has important clinical consequences because it allows the use of protamine in the treatment of coronary perforation and serious bleeding complications that may occur during coronary stent deployment.

Aged↗

Stented segment length as an independent predictor of restenosis.

OBJECTIVES: We sought to evaluate the relation between stented segment length and restenosis. BACKGROUND: Multiple or long coronary stents are now being implanted in long lesions or in tandem lesions. A longer stented segment might result in a higher probability of restenosis. However, there is little information available on the relation between stented segment length and restenosis. METHODS: Between April 1995 and December 1996, 725 patients with 1,090 lesions underwent stenting. Lesions were divided into three groups according to the length of the stented segment: 1) group I (n = 565): stented segment length < or =20 mm; 2) group II (n = 278): stented segment length >20 but < or =35 mm; and 3) group III (n = 247): stented segment length >35 mm. RESULTS: There was no significant difference in the incidence of subacute stent thrombosis among the three groups (0.4% in group I, 0.4% in group II, 1.2% in group III; p = NS). The minimal lumen diameter (MLD) after stenting was greater in group I than in group III (3.04 +/- 0.60 mm in group I, 3.01 +/- 0.54 mm in group II, 2.91 +/- 0.58 mm in group III; p < 0.05). At follow up, a smaller MLD was observed in group III as compared with group I and group II (2.04 +/- 0.93 mm in group I, 1.92 +/- 1.00 mm in group II, 1.47 +/- 0.97 mm in group III; p < 0.01). The restenosis rates were 23.9% in group I, 34.6% in group II and 47.2% in group III (p < 0.01). Using multivariate analysis, the longer stented segment, the angiographic reference vessel diameter and the percent diameter stenosis after stenting were independent predictors of restenosis. CONCLUSIONS: The present study shows that a longer stented segment is an independent predictor of restenosis without an influence on the risk of subacute thrombosis.

Aged↗

Direct coronary stenting without predilation.

OBJECTIVES: Coronary stenting is the primary therapeutic option for percutaneous treatment of many coronary lesions, after the risk of subacute stent thrombosis and bleeding complications has been reduced by improved antithrombotic regimens and high pressure stent expansion. BACKGROUND: Direct stent implantation (without predilation) has been considered a promising new technique that may reduce the procedure time, radiation exposure time and cost. METHODS: After having reviewed all cases of stent implantation from February to June 1998 (n = 585), 185 (32%) of these patients were retrospectively considered candidates for direct stent implantation without predilation, according to prespecified criteria (i.e., absence of severe coronary calcifications and/or tortuosity of the lesion or the segment proximal to the lesion). By operator preference, direct coronary stent implantation was actually attempted in 123 (21%) of the 585 patients (100 men, 60 +/- 10 years old) on 123 lesions. The impact of direct stenting in terms of cost, procedure time, radiation exposure time and amount of contrast dye used was assessed by comparing the two groups of patients who underwent single-vessel stenting without (n = 69) and with (n = 46) predilation. RESULTS: Direct stenting was successful in 118 patients (96%). No acute or subacute complications occurred in these patients. Procedure time, radiation exposure time and cost were significantly lower in the group of patients who had single-vessel direct versus conventional stenting (45 +/- 31 vs. 64 +/- 46 min, 12 +/- 9 vs. 16 +/- 10 min and 1,305 +/- 363 vs. 2,210 +/- 803 Euro, respectively; p < 0.05 for all). CONCLUSIONS: Direct stenting without predilation in selected lesions seems to be a safe and successful procedure that provides a way to contain cost and to shorten radiation exposure time.

Angioplasty, Balloon, Coronary↗

Endovascular treatment of aortic aneurysms of the abdominal aorta with covered stents.

Abdominal aortic aneurysms are common in the aging population; their surgical treatment is well established and allows good results in specialized centers. Endovascular exclusion of abdominal aortic aneurysms has been shown to be feasible since 1991 and nowadays commercially available bifurcated endografts allow safe exclusion in selected cases. In the last year 22 patients with an aorto-iliac aneurysm received endovascular treatment at our Institution. We included patients with favorable anatomic characteristics (i.e. neck > 15 mm length, and < 28 mm diameter, iliac neck < 12 mm diameter, absence of > 90 degrees iliac or aortic angulation) and, in particular, those with increased surgical risk for systemic pathology (12 patients), or hostile abdomen (9 patients). We employed Vanguard II (Boston Scientific) endovascular grafts introduced through a surgically exposed common femoral artery; the contralateral limb of bifurcated grafts was inserted percutaneously. The endograft was successfully implanted in all cases, requiring additional iliac cuffs for complete aneurysm exclusion in 3 cases. Periprocedural morbidity included one case of thrombosis and one case of pseudoaneurysm of the punctured femoral artery, which required surgical treatment. In one case surgical exposure of the iliac artery was required in order to advance the device into the aorta. In one patient who previously underwent hemicolectomy, postoperative colonic ischemia was observed, and pharmacological treatment was required. Moreover we also observed one case of groin infection that was treated successfully with local wound care and systemic antibiotics, and one late contralateral limb thrombosis that was successfully treated with loco-regional thrombolysis. The mean follow-up was 6.1 months: one patient died because of congestive heart failure. No further morbidity was recorded. A type-II endoleak was observed in one patient, originating from the inferior mesenteric artery with no sac enlargement; this patient is still under observation. In conclusion, with proper clinical selection, commercially available endovascular devices allow safe exclusion of abdominal aortic aneurysms. Long-term follow-up is needed to ascertain the durability of the procedure.

Aorta, Abdominal↗

Angiographic and intravascular ultrasound predictors of in-stent restenosis.

OBJECTIVES: This study was performed to determine predictors of in-stent restenosis from a high volume, single-center practice. BACKGROUND: Intracoronary stents have been shown to reduce the restenosis rate as compared with balloon angioplasty, but in-stent restenosis continues to be an important clinical problem. METHODS: Between April 1993 and March 1997, 1,706 patients with 2,343 lesions were treated with a variety of intracoronary stents. The majority of stents were placed with high pressure balloon inflations and intravascular ultrasound (IVUS) guidance. Angiographic follow-up was obtained in 1,173 patients with 1,633 lesions (70%). Clinical, angiographic and IVUS variables were prospectively recorded and analyzed by univariate and multivariate models for the ability to predict the occurrence of in-stent restenosis defined as a diameter stenosis > or =50%. RESULTS: In-stent restenosis was angiographically documented in 282 patients with 409 lesions (25%). The restenosis group had a significantly longer total stent length, smaller reference lumen diameter, smaller final minimal lumen diameter (MLD) by angiography and smaller stent lumen cross-sectional area (CSA) by IVUS. In lesions where IVUS guidance was used, the restenosis rate was 24% as compared with 29% if IVUS was not used (p < 0.05). By multivariate logistic regression analysis, longer total stent length, smaller reference lumen diameter and smaller final MLD were strong predictors of in-stent restenosis. In lesions with IVUS guidance, IVUS stent lumen CSA was a better independent predictor than the angiographic measurements. CONCLUSIONS: Achieving an optimal stent lumen CSA by using IVUS guidance during the procedure and minimizing the total stent length may reduce in-stent restenosis.

Aged↗