Search PubMed⌕ Search

Biomedical subjects

C Contini

Publications and source records attributed to C Contini.

At least 109 records · Page 6Linked to original sources

[Measurement of the myocardial stimulation threshold in chronic and acute patients with pacemaker implanted (author's transl)].

Eighty-two patients, with electrodes implanted for varying periods of time, have been divided into three groups: acute (at implantation); intermediate (3 to 36 months) and chronic (37 to 124 months). In these groups, respectively 28, 26 and 28 myocardial stimulation threshold measurements have been performed. Measurements have been performed with MEEMR (Myocardial Excitation Energy Meter), an instrument deviced and built by the Institute of Elaboration of Information, CNR and University of Pisa. Microjoule has been chosen as unit of measure. More commonly used units of measure, such as threshold current in milliamp, have been calculated from values in microjoules. Mean values was 0.6 muJ in the first group, 6.9 muJ in the second one and 8.3 in the third one. Student test has been performed on such measurements, divided into groups, with the following results: p less than 0.01 between 1st and 2nd group, non significant difference between 2nd and 3rd group, p less than 0.01 between 1st and 3rd group. Such results suggest a trend toward myocardial threshold stabilization over a long period of time, as had already been hypothized by others Authors. Further useful information may be drawn from these data if they are evaluated in relation to a life-time pacemaker, as is nowadays desirable in view of recent progress in circuit technology and energy sources.

Cardiac Pacing, Artificial↗

[The diagnosis of myocardial infarction in the presence of disorders of ventricular activation for right endoventricular pacing and left bundle branch block (author's transl)].

The Authors have studied the vectocardiogram in left bundle branch block, right endoventricular pacing, myocardial infarction and right endoventricular pacing, myocardial infarction and left bundle branch block. Vectocardiographic loop analysis allows the diagnosis of myocardial infarction both in the presence of endoventricular pacing and in the presence of left bundle branch block.

Bundle-Branch Block↗

[Stenosis of superior vena cava at the crossing site of two catheters (author's transl)].

A case of superior vena cava syndrome is described in a patient with two endocardial pacing electrodes. At autopsy a severe stenosis of the venous lumen was found at the crossing site of the two catheters. There was no evidence of thrombus formation. Venous wall stenosis is an unusual complication of transvenous pacing and is probably favoured by the presence of two electrodes.

Cardiac Pacing, Artificial↗

Thyroid and obesity: survey of some function tests in a large obese population.

Tests of thyroid function in 493 obese patients were compared with thyroid function in 3076 non-obese patients. No differences in 131I uptake by the thyroid were observed at 6 h or 24 h; the frequency distribution was gaussian or normal in both populations; the frequencies of normal, high or low T3 and T4 values in the two populations were likewise comparable. Further, no correlation was found in the obese subjects between 131I uptake (6 h and 24 h), T3, T4 and overweight; on the other hand, there was a significant negative correlation between 131I uptake (6 h and 24 h) and age. It would appear that thyroid function is normal in obesity.

Adolescent↗