Search PubMed⌕ Search

Biomedical subjects

C C Ling

Publications and source records attributed to C C Ling.

At least 55 records · Page 3Linked to original sources

Using computerized video time lapse for quantifying cell death of X-irradiated rat embryo cells transfected with c-myc or c-Ha-ras.

Rat embryo fibroblasts that had been transfected with the c-myc or c-Ha-ras oncogene were X-irradiated, after which individual cells and their progeny were followed in multiple fields for 5-6 days by computerized video time lapse microscopy to quantify the lethal events that resulted in loss of clonogenic survival. The loss of clonogenic survival of X-irradiated (9.5 or 2.5 Gy) REC:myc cells was attributed almost entirely to the cells dying by apoptosis, with almost all of the apoptosis occurring after the progeny had divided from one to four times. In contrast, the loss of clonogenic survival of X-irradiated REC:ras cells was attributed to two processes. After 9.5 Gy, approximately approximately 60% of the nonclonogenic cells died by apoptosis (with a very small amount of necrosis), and the other 40% underwent a senescent-type process in which some of the cells and their progeny stopped dividing but remained as viable cells throughout 140 h of observation. Both processes usually occurred after the cells had divided and continued to occur in the cells' progeny for up to five divisions after irradiation. Furthermore, the duration of the apoptotic process was shorter for REC:myc cells (0.5-1 h) than for REC:ras cells (4-5 h). By using computerized video time lapse to follow individual cells, we were able to determine the mode of cell death. This cannot be determined by conventional clonogenic survival experiments. Also, only by following the individual cells and their progeny can the true amount of apoptosis be determined. The cumulative percentage of apoptosis scored in whole populations, without distinguishing between the progeny of individually irradiated cells, does not reflect the true amount of apoptosis that occurs in cells that undergo postmitotic apoptosis after irradiation. Scoring cell death in whole populations of cells gives erroneous results because both clonogenic and nonclonogenic cells are dividing as nonclonogenic cells are apoptosing or senescing over a period of many days. For example, after 9.5 Gy, which causes reproductive cell death in 99% of both types of cells, the cumulative percentage of the cells scored as dead in the whole population at 60- 80 h after irradiation, when the maximum amount of cumulative apoptosis occurred, was approximately 60% for REC:myc cells, compared with only approximately 40% for REC:ras cells.

Animals↗

Computerized design of target margins for treatment uncertainties in conformal radiotherapy.

PURPOSE: We describe a computerized method of determining target margins for beam aperture design in conformal radiotherapy plans. MATERIALS AND METHODS: The method uses previously measured data from a population of patients to simulate setup error and organ motion in the patient currently being planned. Starting with a clinical target volume (CTV) and nontarget organs from the patient's planning CT scan, the simulation is repeated many times to produce a spatial probability distribution for each organ in the treatment machine coordinate system. This is used to determine a prescribed dose volume (PDV), defined as the volume to receive the prescribed dose, which encompasses the CTV while restricting the volume of nontarget organs within it, according to planner-specified values. The PDV is used to design beam apertures using a conventional margin for beam penumbra. RESULTS: The method is applied to 6-field prostate conformal treatment plans, in which the PDV encloses the prostate and seminal vesicles while limiting the enclosed rectal wall volume. The effect of organ motion is assessed by applying the plans on subsequent CT scans of the same patients, calculating probabilities for tumor control (TCP) and normal tissue complication (NTCP), and comparing with plans designed from a physician-drawn planning target volume (PTV). Although prostate TCP and rectal wall NTCP are found to be similar in the two sets of plans, TCP for the seminal vesicles is significantly higher in the PDV-based plans. CONCLUSIONS: The method can improve the dose conformality of treatment plans by incorporating population-based measurements of treatment uncertainties and consideration of nontarget tissues in the design of nonuniform target margins.

Computer Simulation↗

Quantification and predictors of prostate position variability in 50 patients evaluated with multiple CT scans during conformal radiotherapy.

PURPOSE: To determine the extent and predictors for prostatic motion in a large number of patients evaluated with multiple CT scans during radiotherapy, and evaluate the implications of these data on the design of appropriate treatment margins for patients receiving high-dose three-dimensional conformal radiotherapy. MATERIALS AND METHODS: Fifty patients underwent four serial computerized tomography (CT) scans, consisting of an initial planning scan and subsequent scans at the beginning, middle, and end of the treatment course. Each scan was performed with the patient in the prone treatment position within an immobilization device used during therapy. Contours of the prostate and seminal vesicles were drawn on the axial CT slices of each scan, and the scans were matched by alignment of the pelvic bones with a chamfer matching algorithm. Using the contour information, distributions of the displacement of the organ center of mass and organ border from the planning position were determined separately for the prostate and seminal vesicles in each of the three principle directions: anterior-posterior (AP), superior-inferior (SI) and left-right (LR). Each distribution was fitted to a normal (Gaussian) distribution to determine confidence limits in the center of mass and border displacements and thereby evaluate for the optimal margins needed to contain target motion. RESULTS: The most common directions of displacement of the prostate center of mass (COM) were in the AP and SI directions and were significantly larger than any LR movement. The mean prostate COM displacement (+/- 1 standard deviation, SD) for the entire population was -1.2 +/- 2.9 mm, -0.5 +/- 3.3 mm and -0.6 +/- 0.8 mm in the, AP and SI and LR directions respectively (negative values indicate posterior, inferior or left displacement). The mean (+/- 1 SD) seminal vesicle COM displacement for the entire population was - 1.4 +/- 4.9 mm, 1.3 +/- 5.5 mm and -0.8 +/- 3.1 mm in the AP and SI and LR directions, respectively. The data indicate a tendency for the population towards posterior displacements of the prostate from the planning position and both posterior and superior displacements of the seminal vesicles. AP movement of both the prostate and seminal vesicles were correlated with changes in rectal volume (P = 0.0014 and < 0.0001, respectively) more than with changes in bladder volume (P = 0.030 for seminal vesicles and 0.19 for prostate). A logistic regression analysis identified the combination of rectal volume > 60 cm3 and bladder volumes > 40 cm3 as the only predictor of large ( > 3 mm) systematic deviations for the prostate and seminal vesicles (P = 0.05) defined for each patient as the difference between organ position in the planning scan and mean position as calculated from the three subsequent scans. CONCLUSIONS: Prostatic displacement during a course of radiotherapy is more pronounced among patients with initial planning scans with large rectal and bladder volumes. Such patients may require more generous margins around the CTV to assure its enclosure within the prescription dose region. Identification and correction of patients with large systematic errors will minimize the extent of the margin required and decrease the volume of normal tissue exposed to higher radiation doses.

Artifacts↗

Comparison of the 5-year outcome and morbidity of three-dimensional conformal radiotherapy versus transperineal permanent iodine-125 implantation for early-stage prostatic cancer.

PURPOSE: To compare the prostate-specific antigen (PSA) relapse-free survival outcome and incidence of late toxicity for patients with early-stage prostate cancer treated at a single institution with either three-dimensional conformal radiotherapy (3D-CRT) or transperineal permanent implantation (TPI) with iodine-125 seeds. MATERIALS AND METHODS: Patients with favorable-risk prostate cancer, defined as a pretreatment PSA of less than or equal to 10.0 ng/mL, Gleason score of 6 or lower, and stage less than or equal to T2b, were selected for this analysis. Between 1989 and 1996, 137 such patients were treated with 3D-CRT and 145 with TPI. The median ages of the 3D-CRT and TPI groups were 68 years and 64 years, respectively. The median dose of 3D-CRT was 70.2 Gy, and the median implant dose was 150 Gy. Prostate-specific antigen relapse was defined according to the American Society of Therapeutic Radiation Oncology Consensus Statement, and toxicity was graded according to the Radiation Therapy Oncology Group morbidity scoring scale. The median follow-up times for the 3D-CRT and TPI groups were 36 and 24 months, respectively. RESULTS: Eleven patients (8%) in the 3D-CRT group and 12 patients (8%) in the TPI group developed a biochemical relapse. The 5-year PSA relapse-free survival rates for the 3D-CRT and the TPI groups were 88% and 82%, respectively (P = .09). Protracted grade 2 urinary symptoms were more prevalent among patients treated with TPI compared with 3D-CRT. Grade 2 urinary toxicity, which was manifest after the implant and persisted for more than 1 year after this procedure, was observed in 45 patients (31%) in the TPI group. In these 45 patients, the median duration of grade 2 urinary symptoms was 23 months (range, 12 to 70 months). On the other hand, acute grade 2 urinary symptoms resolved within 4 to 6 weeks after completion of 3D-CRT, and the 5-year actuarial likelihood of late grade 2 urinary toxicity for the 3D-CRT group was only 8%. The 5-year actuarial likelihood of developing a urethral stricture (grade 3 urinary toxicity) for the 3D-CRT and TPI groups was 2% and 12%, respectively (P<.0002). Of 45 patients who developed grade 2 or higher urinary toxicity after TPI, the likelihood of resolution or significant improvement of these symptoms at 36 months from onset was 59%. The 5-year likelihood of grade 2 late rectal toxicity for the 3D-CRT and TPI patients was similar (6% and 11%, respectively; P = .97). No patient in either group developed grade 3 or higher late rectal toxicity. The 5-year likelihood of posttreatment erectile dysfunction among patients who were initially potent before therapy was 43% for the 3D-CRT group and 53% for the TPI group (P = .52). CONCLUSION: Both 3D-CRT and TPI are associated with an excellent PSA outcome for patients with early-stage prostate cancer. Urinary toxicities are more prevalent for the TPI group and subsequently resolve or improve in most patients. In addition to evaluating long-term follow-up, future comparisons will require detailed quality-of-life assessments to further determine the impact of these toxicities on the overall well-being and quality of life of the individual patient.

Adenocarcinoma↗

Rejoining of DNA double-strand breaks in Ku80-deficient mouse fibroblasts.

The role of Ku80 in the repair of DNA double-strand breaks (DSBs) was examined in fibroblasts derived from a Ku80 knockout mouse model described by Nussenzweig et al. (Nature 382, 551-555, 1996). Primary fibroblasts from Ku80+/+ and Ku80-/- mice were immortalized by transfection with plasmids containing either the human MYC proto-oncogene or the Simian virus 40 (SV40) T antigen and were used to measure induction and rejoining of DSBs after exposure to ionizing radiation. The number of DSBs in the cells was quantified by either asymmetric field-inversion gel electrophoresis (AFIGE) or clamped homogeneous electrical-field gel electrophoresis (CHEF). The latter method was introduced for a more reliable quantification of repair even when DNA degradation occurs in a fraction of the irradiated cell population during the postirradiation incubation time. The results confirm that Ku80-deficient mouse fibroblasts are sensitive to ionizing radiation and demonstrate that the increased radiosensitivity may result from a deficiency in DSB rejoining. The results further indicate that unless techniques are employed that allow for distinction between DNA degradation and DNA repair, erroneous conclusions may be drawn regarding the potential of cells to repair DSBs.

Animals↗

Dose escalation with three-dimensional conformal radiation therapy affects the outcome in prostate cancer.

PURPOSE: Three-dimensional conformal radiation therapy (3D-CRT) is a technique designed to deliver prescribed radiation doses to localized tumors with high precision, while effectively excluding the surrounding normal tissues. It facilitates tumor dose escalation which should overcome the relative resistance of tumor clonogens to conventional radiation dose levels. The present study was undertaken to test this hypothesis in patients with clinically localized prostate cancer. METHODS AND MATERIALS: A total of 743 patients with clinically localized prostate cancer were treated with 3D-CRT. As part of a phase I study, the tumor target dose was increased from 64.8 to 81 Gy in increments of 5.4 Gy. Tumor response was evaluated by post-treatment decrease of serum prostate-specific antigen (PSA) to levels of < or = 1.0 ng/ml and by sextant prostate biopsies performed > or = 2.5 years after completion of 3D-CRT. PSA relapse-free survival was used to evaluate long-term outcome. The median follow-up was 3 years (range: 1-7.6 years). RESULTS: Induction of an initial clinical response was dose-dependent, with 90% of patients receiving 75.6 or 81.0 Gy achieving a PSA nadir < or = 1.0 ng compared with 76% and 56% for those treated with 70.2 Gy and 64.8 Gy, respectively (p < 0.001). The 5-year actuarial PSA relapse-free survival for patients with favorable prognostic indicators (stage T1-2, pretreatment PSA < or = 10.0 ng/ml and Gleason score < or = 6) was 85%, compared to 65% for those with intermediate prognosis (one of the prognostic indicators with a higher value) and 35% for the group with unfavorable prognosis (two or more indicators with higher values) (p < 0.001). PSA relapse-free survival was significantly improved in patients with intermediate and unfavorable prognosis receiving > or = 75.6 Gy (p < 0.05). A positive biopsy at > or = 2.5 years after 3D-CRT was observed in only 1/15 (7%) of patients receiving 81.0 Gy, compared with 12/25 (48%) after 75.6 Gy, 19/42 (45%) after 70.2 Gy, and 13/23 (57%) after 64.8 Gy (p < 0.05). CONCLUSIONS: The data provide evidence for a significant effect of dose escalation on the response of human prostate cancer to irradiation and defines new standards for curative radiotherapy in this disease.

Aged↗

Ku70: a candidate tumor suppressor gene for murine T cell lymphoma.

We present evidence that inactivation of the Ku70 gene leads to a propensity for malignant transformation both in vitro and in vivo. In vitro, Ku70-/- mouse fibroblasts displayed an increased rate of sister chromatid exchange and a high frequency of spontaneous neoplastic transformation. In vivo, Ku70-/- mice, known to be defective in B but not T lymphocyte maturation, developed thymic and disseminated T cell lymphomas at a mean age of 6 months with CD4+CD8+ tumor cells. These findings directly demonstrate that Ku70 deficiency facilitates neoplastic growth and suggest a novel role of the Ku70 locus in tumor suppression.

Animals↗

Physical and dosimetric aspects of a multileaf collimation system used in the dynamic mode for implementing intensity modulated radiotherapy.

The use of a multileaf collimator in the dynamic mode to perform intensity modulated radiotherapy became a reality at our institution in 1995. Unlike treatment with static fields using a multileaf collimator, there are significant dosimetric issues which must be assessed before dynamic therapy can be implemented. We have performed a series of calculations and measurements to quantify head scatter for small fields, collimator transmission, and the transmission through rounded leaf ends. If not accounted for, these factors affect the delivered dose to the prostate by 5%-20% for a typical plan. Data obtained with ion chambers and radiographic film are presented for both 6 and 15 MV x-ray beams. The impact on the delivered dose of the mechanical accuracy of the multileaf collimator, achieved during leaf position calibration and maintained during dose delivery, is also discussed.

Biophysical Phenomena↗

Locally advanced prostatic cancer: long-term toxicity outcome after three-dimensional conformal radiation therapy--a dose-escalation study.

PURPOSE: To determine the long-term effects of 75.6- and 81.0-Gy doses of three-dimensional conformal radiation therapy in a dose-escalation study in patients with stage T2c-T3 prostatic cancer. MATERIALS AND METHODS: Fifty patients received an initial 75.6-Gy dose, and the dose in 46 patients was subsequently escalated to 81.0-Gy. Median follow-up was 60 and 40 months, respectively. RESULTS: The rates of effects of acute toxicity during the course of treatment were similar for both dose levels. Among the 96 patients, the rate of grade 2 morbidities necessitating medication to relieve acute symptoms was 17% (16 patients) for rectal and 36% (35 patients) for urinary morbidities. All other patients had either no or grade 1 morbidities. Fourteen patients (15%) developed late grade 2 rectal morbidities. There were no differences in 5-year actuarial rates of late grade 2 rectal or urinary morbidities among patients who received 75.6 Gy versus those who received 81.0 Gy. One patient treated with 81.0 Gy developed a grade 3 urethral stricture, which was resolved with dilatation. CONCLUSION: Tumor dose escalation beyond conventional radiation doses for localized prostatic cancer is feasible when delivered with three-dimensional conformal radiation therapy, with no increase in morbidity in normal tissue.

Actuarial Analysis↗

Predictors of improved outcome for patients with localized prostate cancer treated with neoadjuvant androgen ablation therapy and three-dimensional conformal radiotherapy.

PURPOSE: To identify prognostic variables that predict for improved biochemical and local control outcome in patients with localized prostatic cancer treated with neoadjuvant androgen deprivation (NAAD) and three-dimensional conformal radiotherapy (3D-CRT). MATERIALS AND METHODS: Between 1989 and 1995, 213 patients with localized prostate cancer were treated with a 3-month course of NAAD that consisted of leuprolide acetate and flutamide before 3D-CRT. The purpose of NAAD in these patients was to reduce the preradiotherapy target volume so as to decrease the dose delivered to adjacent normal tissues and thereby minimize the risk of morbidity from high-dose radiotherapy. The median pretreatment prostate-specific antigen (PSA) level was 15.3 ng/mL (range, 1 to 560 ng/mL). The median 3D-CRT dose was 75.6 Gy (range, 64.8 to 81 Gy), and the median follow-up time was 3 years (range, 1 to 7 years). RESULTS: The significant predictors for improved outcome as identified in a multivariate analysis included pretreatment PSA level < or = 10.0 ng/mL(P < .00), NAAD-induced preradiotherapy PSA nadir < or = 0.5 ng/mL (P < .001), and clinical stage < or = T2c (P < .04). The 5-year PSA relapse-free survival rates were 93%, 60%, and 40% for patients with pretreatment PSA levels < or = 10 ng/mL, 10 to 20 ng/mL, and greater than 20 ng/mL, respectively (P < .001). Patients with preradiotherapy nadir levels < or = 0.5 ng/mL after 3 months of NAAD experienced a 5-year PSA relapse-free survival rate of 74%, as compared with 40% for patients with higher nadir levels (P < .001). The incidence of a positive biopsy among 34 patients pretreated with androgen ablation was 12%, as compared with 39% for 117 patients treated with 3D-CRT alone who underwent a biopsy (P < .001). CONCLUSION: For patients treated with NAAD and high-dose 3D-CRT, pretreatment PSA, preradiotherapy PSA nadir response, and clinical stage are important predictors of biochemical outcome. Patients with NAAD-induced PSA nadir levels greater than 0.5 ng/mL before radiotherapy are more likely to develop biochemical failure and may benefit from more aggressive therapies.

Aged↗

Planning, delivery, and quality assurance of intensity-modulated radiotherapy using dynamic multileaf collimator: a strategy for large-scale implementation for the treatment of carcinoma of the prostate.

PURPOSE: To improve the local control of patients with adenocarcinoma of the prostate we have implemented intensity modulated radiation therapy (IMRT) to deliver a prescribed dose of 81 Gy. This method is based on inverse planning and the use of dynamic multileaf collimators (DMLC). Because IMRT is a new modality, a major emphasis was on the quality assurance of each component of the process and on patient safety. In this article we describe in detail our procedures and quality assurance program. METHODS AND MATERIALS: Using an inverse algorithm, we have developed a treatment plan consisting five intensity-modulated (IM) photon fields that are delivered with DMLC. In the planning stage, the planner specifies the number of beams and their directions, and the desired doses for the target, the normal organs and the "overlap" regions. Then, the inverse algorithm designs intensity profiles that best meet the specified criteria. A second algorithm determines the leaf motion that would produce the designed intensity pattern and produces a DMLC file as input to the MLC control computer. Our quality assurance program for the planning and treatment delivery process includes the following components: 1) verification of the DMLC field boundary on localization port film, 2) verification that the leaf motion of the DMLC file produces the planned dose distribution (with an independent calculation), 3) comparison of dose distribution produced by DMLC in a flat phantom with that calculated by the treatment planning computer for the same experimental condition, 4) comparison of the planned leaf motions with that implemented for the treatment (as recorded on the MLC log files), 5) confirmation of the initial and final positions of the MLC for each field by a record-and-verify system, and 6) in vivo dose measurements. RESULTS: Using a five-field IMRT plan we have customized dose distribution to conform to and deliver 81 Gy to the PTV. In addition, in the overlap regions between the PTV and the rectum, and between the PTV and the bladder, the dose is kept within the tolerance of the respective organs. Our QA checks show acceptable agreement between the planned and the implemented leaf motions. Correspondingly, film and TLD dosimetry indicates that doses delivered agrees with the planned dose to within 2%. As of September 15, 1996, we have treated eight patients to 81 Gy with IMRT. CONCLUSION: For complex planning problems where the surrounding normal tissues place severe constraints on the prescription dose, IMRT provides a powerful and efficient solution. Given a comprehensive and rigorous quality-assurance program, the intensity-modulated fields can be efficaciously and accurately delivered using DMLC. IMRT treatment is now ready for routine implementation on a large scale in our clinic.

Adenocarcinoma↗

Number and orientations of beams in intensity-modulated radiation treatments.

The fundamental question of how many equispaced coplanar intensity-modulated photon beams are required to obtain an optimum treatment plan is investigated in a dose escalation study for a typical prostate tumor. Furthermore, optimization of beam orientations to improve dose distributions is explored. A dose-based objective function and a fast gradient technique are employed for optimizing the intensity profiles (inverse planning). An exhaustive search and fast simulated annealing techniques (FSA) are used to optimize beam orientations. However, to keep computation times reasonable, the intensity profiles for each beam arrangement are still optimized using inverse planning. A pencil beam convolution algorithm is employed for dose calculation. All calculations are performed in three-dimensional (3D) geometry for 15 MV photons. DVHs, dose displays, TCP, NTCP, and biological score functions are used for evaluation of treatment plans. It is shown that for the prostate case presented here, the minimum required number of equiangular beams depends on the prescription dose level and ranges from three beams for 70 Gy plans to seven to nine beams for 81 Gy plans. For the highest dose level (81 Gy), beam orientations are optimized and compared to equiangular spaced arrangements. It is shown that (1) optimizing beam orientations is most valuable for a small numbers of beams (< or = 5) and the gain diminishes rapidly for higher numbers of beams; (2) if sensitive structures (for example rectum) are partially enclosed by the target volume, beams coming from their direction tend to be preferable, since they allow greater control over dose distributions; (3) while FSA and an exhaustive search lead to the same results, computation times using FSA are reduced by two orders of magnitude to clinically acceptable values. Moreover, characteristics of and demands on biology-based and dose-based objective functions for optimization of intensity-modulated treatments are discussed.

Algorithms↗

Characterization of radiation-induced apoptosis in rodent cell lines.

For REC:myc(ch1), Rat1 and Rat1:myc(b) cells, we determined the events in the development of radiation-induced apoptosis to be in the following order: cell division followed by chromatin condensation, membrane blebbing, loss of adhesion and the uptake of vital dye. Experimental data which were obtained using 4He ions of well-defined energies and which compared the dependence of apoptosis and clonogenic survival on 4He range strongly suggested that in our cells both apoptosis and loss of clonogenic survival resulted from radiation damage to the cell nucleus. Corroboratory evidence was that BrdU incorporation sensitized these cells to radiation-induced apoptosis. Comparing the dose response for apoptosis and the clonogenic survival curves for Rat1 and Rat1:myc(b) cells, we concluded that radiation-induced apoptosis contributed to the overall radiation-induced cell inactivation as assayed by clonogenic survival, and that a modified linear-quadratic model, proposed previously, modeled such a contribution effectively. In the same context, the selective increase in radiation-induced apoptosis during late S and G2 phases reduced the relative radioresistance observed for clonogenic survival during late S and G2 phases.

Animals↗

Down-regulation of gadd153 by c-myc in rat fibroblasts and its effect on cell growth and radiation-induced apoptosis.

Using differential display reverse transcription PCR (DDRT - PCR), we found that a 360 bp cDNA fragment was absent in several c-myc transfected rat fibroblasts: REC:myc, REC:myc + ras and rat1-myc. These cells also showed enhanced sensitivity to gamma ray-induced apoptosis. This cDNA fragment was present in the parental REC (Rat Embryo Cells) and rat1 cells, and in c-Ha-ras transfected REC (REC:ras), all of which were relatively resistant to gamma ray-induced apoptosis. The cDNA fragment was subsequently cloned and used as a probe to screen a rat1 cDNA library, and identified as one of the growth arrest and DNA damaging-inducible genes, gadd153. In addition to the down-regulation of rat gadd153 in all the c-myc transfectants, methyl methanesulfonate (MMS)-induced transcription of the gadd153 was attenuated. The rat1-myc cells, when successfully transfected with and stably expressing the rat gadd153, showed a significantly longer doubling time compared to the parental cells. However, overexpression of gadd153 in rat1-myc cells did not affect gamma ray-induced apoptosis. Thus, the suppression of gadd153 appears to be inversely correlated with that of myc, but not involved in the myc-dependent apoptotic pathway.

Animals↗

Apoptosis induced by X-irradiation of rec-myc cells is postmitotic and not predicted by the time after irradiation or behavior of sister cells.

Rat embryo cells expressing the c-myc oncogene (rec-myc) were studied by time-lapse microscopy to determine whether radiation-induced apoptosis occurred before or after mitosis. Following X-irradiation with 9.5 Gy, cells were imaged every 3 min for 6 days. Episodes of apoptotic blebbing were very consistent from cell to cell, lasting 30-60 min, followed by cessation of movement and cell death. In contrast, the time of initiation of apoptotic blebbing was unpredictable. At least 96% of the apoptotic episodes were postmitotic, after one to four cell divisions and 2-97 h after a given division. Sister cells often behaved differently from one another, with apoptosis in one sister occurring many h or several divisions after apoptosis in the other. Thus, the onset of radiation-induced apoptosis in rec-myc cells is not strictly programmed but may result from the segregation of chromosome aberrations in the postirradiation generations.

Animals↗

Conformal radiation treatment of prostate cancer using inversely-planned intensity-modulated photon beams produced with dynamic multileaf collimation.

PURPOSE: To implement radiotherapy with intensity-modulated beams, based on the inverse method of treatment design and using a multileaf collimation system operating in the dynamic mode. METHODS AND MATERIALS: An algorithm, based on the inverse technique, has been integrated into the radiotherapy treatment-planning computer system in our Center. This method of computer-assisted treatment design was used to derive intensity-modulated beams to optimize the boost portion of the treatment plan for a patient with a T1c cancer of the prostate. A dose of 72 Gy (in 40 fractions) was given with a six-field plan, and an additional 9 Gy (in five fractions) with six intensity-modulated beams. The intensity-modulated fields were delivered using dynamic multileaf collimation, that is, individual leaves were in motion during radiation delivery, with the treatment machine operating in the clinical mode. Exhaustive quality assurance measurement and monitoring were carried out to ensure safe and accurate implementation. RESULTS: Dose distribution and dose-volume histogram of the "inverse method" boost plan and of the composite (72 Gy primary + 9 Gy boost) plan were judged clinically acceptable. Compared to a manually designed boost plan, the inverse treatment design gave improved conformality and increased dose homogeneity in the planning target volume. Film and ion chamber dosimetry, performed prior to the first treatment, indicated that each of the six intensity-modulated fields was accurately produced. Thermoluminescent dosimeter (TLD) measurements performed on the patient confirmed that the intended dose was delivered in the treatment. In addition, computer-aided treatment-monitoring programs assured that the multileaf collimator (MLC) position file was executed to the specified precision. In terms of the overall radiation treatment process, there will likely be labor savings in the planning and the treatment phases. CONCLUSIONS: We have placed into clinical use an integrated system of conformal radiation treatment that incorporated the inverse method of treatment design and the use of dynamic multileaf collimation to deliver intensity-modulated beams. The system can provide better treatment design, which can be implemented reliably and safely. We are hopeful that improved treatment efficacy will result.

Humans↗

The effect of setup uncertainties on the radiobiological advantage of fractionation in stereotaxic radiotherapy.

PURPOSE: There may be radiobiological advantages in administering stereotaxic radiation treatment in multiple fractions instead of by a single irradiation. However, a larger planning target volume may be required for fractionated stereotaxic radiotherapy than for a single session treatment, if decreased geometrical precision and increased setup uncertainty are associated with multiple-fraction treatments. This factor may partially offset the radiobiological gain. The purpose of this study is to estimate the potential therapeutic gain of fractionated treatments for brain tumors, and to assess the effect of increased setup uncertainty on the potential gain. METHODS AND MATERIALS: The concept of biologically effective dose (BED), based on the linear quadratic (LQ) model, was used to quantify the therapeutic efficacy of the respective treatment schema. Therapeutic gain (TG) was defined as the ratio of tumor BEDs, for multiple fractions and single treatment, respectively, for the same normal brain BED. To include the effect of increased planning volume in fractionated treatment, a power-law relationship was assumed for the volume dependence of prescription dose, and the TG was recalculated using the "volume-adjusted" doses. RESULTS: The therapeutic gain for fractionated treatment increases with fraction number, and is smaller for larger single treatment doses. For example, in going from 1 to 10 fractions, the TG is 1.40, 1.32, or 1.27 for single treatment dose of 20, 30, or 40 Gy, respectively. Also, the TG is more significant for the initial few fractions. The benefit of fractionation is diminished if larger planning volume is needed for multiple fraction treatments. For example, the above TG are reduced to 1.19, 1.11, or 1.06, if a 2 cm planning target volume in single fraction treatment is enlarged to 2.3 cm in fractionated treatment. CONCLUSION: Consideration of the therapeutic gain with fractionation should include estimates of setup uncertainty for multiple-fraction treatments, relative to that of single fraction radiosurgery.

Brain Neoplasms↗