An iterative EPID calibration procedure for dosimetric verification that considers the EPID scattering factor.

There has been an increasing interest in the application of electronic portal imaging devices (EPIDs) to dosimetric verification, particularly for intensity modulated radiotherapy. Although not water equivalent, the phantom scatter factor of an EPID, Spe, is generally assumed to be that of a full phantom, Sp, a slab phantom, Sps, or a mini phantom. This assumption may introduce errors in absolute dosimetry using EPIDs. A calibration procedure that iteratively updates Spe and the calibration curve (pixel value to dose rate) is presented. The EPID (Varian Portal Vision) is irradiated using a 20 x 20 cm2 field with different beam intensities. The initial guess of dose rates in the EPID is calculated from ionization chamber measurements in air, multiplied by Sp or Sps. The calibration curve is obtained by fitting EPID readings from pixels near the beam central axis and dose rates in EPID to a quadratic equation. The Spe is obtained from EPID measurements in 10 X 10 cm2 and 20 x 20 cm2 field and from the calibration curve, and is in turn used to adjust the dose rate measurements and hence the calibration curve. The above procedure is repeated until it converges. The final calibration curve is used to convert portal dose to dose in the slab phantom, using the calibrated Spe, or assuming Spe = Sp or Spe=Sps . The converted doses are then compared with the dose measured using an ionization chamber. We also apply this procedure to off-axis points and study its dependence on the energy spectrum. The hypothesis testing results (on the 95% significance level) indicate that systematic errors are introduced when assuming Spe = Sp or Spe=Sps and the dose calculated using Spe is more consistent with ionization chamber measurements. Differences between Spe and Sps are as large as 2% for large field sizes. The measured relative dose profile at dmax using the EPID agrees well with the measured profile at dmax of the isocentric plane using film in a polystyrene phantom with full buildup and full backup, for open and wedged fields, and for a broad range of field sizes of interest. The dependence of the EPID response on the energy spectrum is removed once the calibration is performed under the same conditions as the actual measurements.

Algorithms↗

Delivery of intensity-modulated radiation therapy with a conventional multileaf collimator: comparison of dynamic and segmental methods.

Intensity-modulated radiation therapy (IMRT) can be delivered with a conventional multileaf collimator (MLC), either in dynamic mode (DMLC) or in segmental mode (SMLC, also known as "step-and-shoot"). The advantage of DMLC is its ability to deliver the desired intensity profile produced by inverse planning with a high degree of fidelity. The SMLC method, on the other hand, resembles treatment with multiple static fields, and can be more easily verified. However, the use of SMLC requires that the desired profile be approximated by discrete levels of intensity, which may lead to degradation in the delivered dose distribution. Clearly, the results of SMLC delivery depend on the number of levels and the spatial resolution of the intensity distribution. In this work, we compare the DMLC method and the SMLC method employing different numbers of levels and different spatial resolutions. Three disease sites were studied: prostate, nasopharynx, and breast, with three cases for each. In general, a 5- to 10-level SMLC plan produced results comparable to that from a DMLC plan. The target coverage is improved by increasing the number of levels while critical organs are better protected with finer spatial resolutions. The beam-on-time (MUs) requirement for SMLC was approximately 20% less than DMLC, but the delivery time (in minutes) was about twice as long. Thus, the choice depends on many factors including machine capability, quality assurance, target coverage, critical organ protection, beam-on-time, delivery time, and other clinical considerations.

Breast Neoplasms↗

The treatment of large extraskeletal chondrosarcoma of the leg: comparison of IMRT and conformal radiotherapy techniques.

Extraskeletal chondrosarcoma of the leg is a rare, malignant neoplasm with very few cases having been reported in the literature. In this study we investigate the possibility of using intensity modulated radiotherapy (IMRT) for this type of disease and demonstrate its advantages over conventional three-dimensional (3D) conformal treatment. A case was presented of a patient with extraskeletal chondrosarcoma of the lateral compartment of the leg in which the target volume was 50 cm in length and twisted around the surrounding bones. Both the 3D conformal plan and IMRT plan were designed using the Memorial Sloan-Kettering Cancer Center planning system. The IMRT plan produced a superior dose distribution to the patient as compared to the 3D conformal plan both in terms of dose conformity and homogeneity in the target volumes, and reduction of the maximum dose to the bone. The planning time of the IMRT plan was about 3-5 times shorter than that of the 3D conformal plan. It was demonstrated that the IMRT technique can be used not just for small tumors, but also for large and spiral-shaped tumors close to critical organs. The IMRT method requires less planning time, and provides better target coverage with more sparing of critical structures. When planning patients with multiple target volumes receiving different prescribed doses, the IMRT technique can more easily meet this requirement.

Adult↗

Fluoroscopic evaluation of diaphragmatic motion reduction with a respiratory gated radiotherapy system.

We report on initial patient studies to evaluate the performance of a commercial respiratory gating radiotherapy system. The system uses a breathing monitor, consisting of a video camera and passive infrared reflective markers placed on the patient's thorax, to synchronize radiation from a linear accelerator with the patient's breathing cycle. Six patients receiving treatment for lung cancer participated in a study of system characteristics during treatment simulation with fluoroscopy. Breathing synchronized fluoroscopy was performed initially without instruction, followed by fluoroscopy with recorded verbal instruction (i.e., when to inhale and exhale) with the tempo matched to the patient's normal breathing period. Patients tended to inhale more consistently when given instruction, as assessed by an external marker movement. This resulted in smaller variation in expiration and inspiration marker positions relative to total excursion, thereby permitting more precise gating tolerances at those parts of the breathing cycle. Breathing instruction also reduced the fraction of session times having irregular breathing as measured by the system software, thereby potentially increasing the accelerator duty factor and decreasing treatment times. Fluoroscopy studies showed external monitor movement to correlate well with that of the diaphragm in four patients, whereas time delays of up to 0.7 s in diaphragm movement were observed in two patients with impaired lung function. From fluoroscopic observations, average patient diaphragm excursion was reduced from 1.4 cm (range 0.7-2.1 cm) without gating and without breathing instruction, to 0.3 cm (range 0.2-0.5 cm) with instruction and with gating tolerances set for treatment at expiration for 25% of the breathing cycle. Patients expressed no difficulty with following instruction for the duration of a session. We conclude that the external monitor accurately predicts internal respiratory motion in most cases; however, it may be important to check with fluoroscopy for possible time delays in patients with impaired lung function. Furthermore, we observe that verbal instruction can improve breathing regularity, thus improving the performance of gated treatments with this system.

Diaphragm↗

Hypoxia-Induced increase in FDG uptake in MCF7 cells.

UNLABELLED: Recent clinical data indicate that tumor hypoxia negatively affects the treatment outcome of both radiotherapy and surgery in various cancers, emphasizing the need for noninvasive detection of tumor hypoxia. Several studies have shown an increased uptake of FDG in hypoxic regions of xenografts, suggesting the use of PET with FDG as a potential technique. In this study, we examine the mechanism underlying the hypoxia-induced increase of FDG uptake in the human breast carcinoma cell line MCF7. METHODS: The uptake of 3H-FDG into MCF7 cells was determined after incubation under hypoxic (0% oxygen) or normoxic conditions, with or without redox agents, for varying time periods. In addition, the effects of the redox agents on the glucose transporter activity and the hexokinase activity were determined independently, and the effects of hypoxia on glucose transporter protein and hexokinase levels were assessed. RESULTS: A more than twofold increase (2.53 +/- 0.79; P < 0.005) in 3H-FDG uptake was observed under hypoxic conditions, but no changes in the cellular levels of glucose transporter proteins or hexokinase were observed. A reducing agent, dithiothreitol (DTT), also caused an increase in 3H-FDG uptake but failed to affect uptake under hypoxic conditions. This indicates that the mechanisms by which hypoxia and DTT affect 3H-FDG uptake might be the same. The oxidizing agent p-chloromercuribenzenesulfonic acid (pCMBS) had no effect on 3H-FDG uptake under normoxic conditions but counteracted the effect of hypoxia. DTT caused an increase in glucose transporter activity, whereas it had no effect on hexokinase activity. pCMBS had no effect on either glucose transporter activity or hexokinase activity. CONCLUSION: The hypoxia-induced increase in 3H-FDG uptake in MCF7 cells is the result, in part, of an increase in glucose transporter activity resulting from the modification (reduction) of thiol group(s) in the glucose transport protein(s). Modulation of hexokinase activity is probably not involved in the hypoxia-induced increase in 3H-FDG uptake in these cells.

4-Chloromercuribenzenesulfonate↗

High dose radiation delivered by intensity modulated conformal radiotherapy improves the outcome of localized prostate cancer.

PURPOSE: We present the long-term outcome and tolerance of 3-dimensional (D) conformal and intensity modulated radiation therapy for localized prostate cancer. MATERIALS AND METHODS: Between October 1988 and December 1998, 1,100 patients with clinical stages T1c-T3 prostate cancer were treated with 3-D conformal or intensity modulated radiation therapy. Patients were categorized into prognostic risk groups based on pretreatment prostate specific antigen (PSA), Gleason score and clinical stage. Sextant biopsies were performed 2.5 years or greater after treatment to assess local control. PSA relapse was defined according to the consensus guidelines of the American Society for Therapeutic Radiation Oncology. Late toxicity was classified according to the Radiation Therapy Oncology Group morbidity grading scale. Median followup was 60 months. RESULTS: At 5 years the PSA relapse-free survival rate in patients at favorable, intermediate and unfavorable risk was 85% (95% confidence interval [CI] +/- 4), 58% (95% CI +/- 6) and 38% (95% CI +/- 6), respectively (p <0.001). Radiation dose was the most powerful variable impacting PSA relapse-free survival in each prognostic risk group. The 5-year actuarial PSA relapse-free survival rate for patients at favorable risk who received 64.8 to 70.2 Gy. was 77% (95% CI +/- 8) compared to 90% (95% CI +/- 8) for those treated with 75.6 to 86.4 Gy. (p = 0.04) [corrected]. The corresponding rates were 50% (95% CI +/- 8) versus 70% (95% CI +/- 6) in intermediate risk cases (p = 0.001), and 21% (95% CI +/- 8) versus 47% (95% CI +/- 6) in unfavorable risk cases (p = 0.008) [corrected]. Only 4 of 41 patients (10%) who received 81 Gy. had a positive biopsy 2.5 years or greater after treatment compared with 27 of 119 (23%) after 75.6, 23 of 68 (34%) after 70.2 and 13 of 24 (54%) after 64.8 Gy. The incidence of toxicity after 3-D conformal radiation therapy was dose dependent. The 5-year actuarial rate of grade 2 rectal toxicity in patients who received 75.6 Gy. or greater was 14% (95% CI +/- 2) compared with 5% (95% CI +/- 2) in those treated at lower dose levels (p <0.001). Treatment with intensity modulated radiation therapy significantly decreased the incidence of late grade 2 rectal toxicity since the 3-year actuarial incidence in 189 cases managed by 81 Gy. was 2% (95% CI +/- 2) compared with 14% (95% CI +/- 2) in 61 managed by the same dose of 3-D conformal radiation therapy (p = 0.005). The 5-year actuarial rate of grade 2 urinary toxicity in patients who received 75.6 Gy. or greater 3-D conformal radiation therapy was 13% compared with 4% in those treated up to lower doses (p <0.001). Intensity modulated radiation therapy did not affect the incidence of urinary toxicity. CONCLUSIONS: Sophisticated conformal radiotherapy techniques with high dose 3-D conformal and intensity modulated radiation therapy improve the biochemical outcome in patients with favorable, intermediate and unfavorable risk prostate cancer. Intensity modulated radiation therapy is associated with minimal rectal and bladder toxicity, and, hence, represents the treatment delivery approach with the most favorable risk-to-benefit ratio.

Adenocarcinoma↗

Technical aspects of the deep inspiration breath-hold technique in the treatment of thoracic cancer.

PURPOSE: The goal of this paper is to describe our initial experience with the deep inspiration breath-hold (DIBH) technique in conformal treatment of non-small-cell lung cancer with particular emphasis on the technical aspects required for implementation. METHODS AND MATERIALS: In the DIBH technique, the patient is verbally coached through a modified slow vital capacity maneuver and brought to a reproducible deep inspiration breath-hold level. The goal is to immobilize the tumor and to expand normal lung out of the high-dose region. A physicist or therapist monitors and records patient breathing during simulation, verification, and treatment using a spirometer with a custom computer interface. Examination of internal anatomy during fluoroscopy over multiple breath holds establishes the reproducibility of the DIBH maneuver for each patient. A reference free-breathing CT scan and DIBH planning scan are obtained. To provide an estimate of tumor motion during normal tidal breathing, additional scan sets are obtained at end inspiration and end expiration. These are also used to set the spirometer action levels for treatment. Patient lung inflation is independently verified over the course of treatment by comparing the distance from the isocenter to the diaphragm measured from the DIBH digitally reconstructed radiographs to the distance measured on the portal films. Patient breathing traces obtained during treatment were examined retrospectively to assess the reproducibility of the technique. RESULTS: Data from the first 7 patients, encompassing over 250 treatments, were analyzed. The inferred displacement of the centroid of gross tumor volume from its position in the planning scan, as calculated from the spirometer records in over 350 breath holds was 0.02 +/- 0.14 cm (mean and standard deviation). These data are consistent with the displacements of the diaphragm (-0.1 +/- 0.4 cm; range, from -1.2 to 1.1 cm) relative to the isocenter, as measured on the (92) portal films. The latter measurements include the patient setup error. The patient averaged displacement of the tumor during free breathing, determined from the tumor displacement between end inspiration and end expiration, was 0.8 +/- 0.5 cm in both the superior-inferior and anterior-posterior directions and 0.1 cm (+/- 0.1 cm) medial-laterally. CONCLUSION: Treatment of patients with the DIBH technique is feasible in a clinical setting. With this technique, consistent lung inflation levels are achieved in patients, as judged by both spirometry and verification films. Breathing-induced tumor motion is significantly reduced using DIBH compared to free breathing, enabling better target coverage.

Carcinoma, Non-Small-Cell Lung↗

The deep inspiration breath-hold technique in the treatment of inoperable non-small-cell lung cancer.

PURPOSE: Conventional radiotherapeutic techniques are associated with lung toxicity that limits the treatment dose. Motion of the tumor during treatment requires the use of large safety margins that affect the feasibility of treatment. To address the control of tumor motion and decrease the volume of normal lung irradiated, we investigated the use of three-dimensional conformal radiation therapy (3D-CRT) in conjunction with the deep inspiration breath-hold (DIBH) technique. METHODS AND MATERIALS: In the DIBH technique, the patient is initially maintained at quiet tidal breathing, followed by a deep inspiration, a deep expiration, a second deep inspiration, and breath-hold. At this point the patient is at approximately 100% vital capacity, and simulation, verification, and treatment take place during this phase of breath-holding. RESULTS: Seven patients have received a total of 164 treatment sessions and have tolerated the technique well. The estimated normal tissue complication probabilities decreased in all patients at their prescribed dose when compared to free breathing. The dose to which patients could be treated with DIBH increased on average from 69.4 Gy to 87.9 Gy, without increasing the risk of toxicity. CONCLUSIONS: The DIBH technique provides an advantage to conventional free-breathing treatment by decreasing lung density, reducing normal safety margins, and enabling more accurate treatment. These improvements contribute to the effective exclusion of normal lung tissue from the high-dose region and permit the use of higher treatment doses without increased risks of toxicity.

Carcinoma, Non-Small-Cell Lung↗

Analysis of biopsy outcome after three-dimensional conformal radiation therapy of prostate cancer using dose-distribution variables and tumor control probability models.

PURPOSE: To investigate tumor control following three-dimensional conformal radiation therapy (3D-CRT) of prostate cancer and to identify dose-distribution variables that correlate with local control assessed through posttreatment prostate biopsies. METHODS AND MATERIAL: Data from 132 patients, treated at Memorial Sloan-Kettering Cancer Center (MSKCC), who had a prostate biopsy 2.5 years or more after 3D-CRT for T1c-T3 prostate cancer with prescription doses of 64.8-81 Gy were analyzed. Variables derived from the dose distribution in the PTV included: minimum dose (Dmin), maximum dose (Dmax), mean dose (Dmean), dose to n% of the PTV (Dn), where n = 1%,...,99%. The concept of the equivalent uniform dose (EUD) was evaluated for different values of the surviving fraction at 2 Gy (SF(2)). Four tumor control probability (TCP) models (one phenomenologic model using a logistic function and three Poisson cell kill models) were investigated using two sets of input parameters, one for low and one for high T-stage tumors. Application of both sets to all patients was also investigated. In addition, several tumor-related prognostic variables were examined (including T-stage, Gleason score). Univariate and multivariate logistic regression analyses were performed. The ability of the logistic regression models (univariate and multivariate) to predict the biopsy result correctly was tested by performing cross-validation analyses and evaluating the results in terms of receiver operating characteristic (ROC) curves. RESULTS: In univariate analysis, prescription dose (Dprescr), Dmax, Dmean, dose to n% of the PTV with n of 70% or less correlate with outcome (p < 0.01). The area under the ROC curve for Dmean is 0.64. In contrast, Dmin (p = 0.6), D98 (p = 0.2) or D95 (p = 0.1) are not significantly correlated with outcome. The results for EUD depend on the input parameter SF(2): EUD correlates significantly with outcome for SF(2) of 0.4 or more, but not for lower SF(2) values. Using either of the two input parameters sets, all TCP models correlate with outcome (p < 0.05; ROC areas 0.60-0.62). Using T-stage dependent input parameters, the correlation is improved (logistic function: p < 0.01, ROC area 0.67, Poisson models: p < 0.01, ROC areas 0.64-0.66). In comparison, the ROC area is 0.68 for the combination of Dmean and T-stage. After multivariate analysis, a model based on TCP, D20 and Gleason score is the best overall model (ROC area 0.73). However, an alternative model based on Dmean, Gleason score, and T-stage is competitive (ROC area 0.70). CONCLUSION: Biopsy outcome after 3D-CRT of prostate cancer at MSKCC is not correlated with Dmin in the PTV and appears to be insensitive to cold spots in the dose distribution. This observation likely reflects the fact that much of the PTV, especially at the periphery, may not contain viable tumor cells and that the treatment margins were sufficiently large. Therefore, the predictive power of all variables which are sensitive to cold spots, like TCPs with Poisson models and EUD for low SF(2), is limited because the low dose region may not coincide with the tumor location. Instead, for MSKCC prostate cancer patients with their standardized CTV definition, substantial target motion and small dose inhomogeneities, Dmean (or any variable that downplays the effect of cold spots) is a very good predictor of biopsy outcome. While our findings may indicate a general problem in the application of current TCP models to clinical data, these conclusions should not be extrapolated to other disease sites without careful analysis.

Analysis of Variance↗

Towards multidimensional radiotherapy (MD-CRT): biological imaging and biological conformality.

PURPOSE: The goals of this study were to survey and summarize the advances in imaging that have potential applications in radiation oncology, and to explore the concept of integrating physical and biological conformality in multidimensional conformal radiotherapy (MD-CRT). METHODS AND MATERIALS: The advances in three-dimensional conformal radiotherapy (3D-CRT) have greatly improved the physical conformality of treatment planning and delivery. The development of intensity-modulated radiotherapy (IMRT) has provided the "dose painting" or "dose sculpting" ability to further customize the delivered dose distribution. The improved capabilities of nuclear magnetic resonance imaging and spectroscopy, and of positron emission tomography, are beginning to provide physiological and functional information about the tumor and its surroundings. In addition, molecular imaging promises to reveal tumor biology at the genotype and phenotype level. These developments converge to provide significant opportunities for enhancing the success of radiotherapy. RESULTS: The ability of IMRT to deliver nonuniform dose patterns by design brings to fore the question of how to "dose paint" and "dose sculpt", leading to the suggestion that "biological" images may be of assistance. In contrast to the conventional radiological images that primarily provide anatomical information, biological images reveal metabolic, functional, physiological, genotypic, and phenotypic data. Important for radiotherapy, the new and noninvasive imaging methods may yield three-dimensional radiobiological information. Studies are urgently needed to identify genotypes and phenotypes that affect radiosensitivity, and to devise methods to image them noninvasively. Incremental to the concept of gross, clinical, and planning target volumes (GTV, CTV, and PTV), we propose the concept of "biological target volume" (BTV) and hypothesize that BTV can be derived from biological images and that their use may incrementally improve target delineation and dose delivery. We emphasize, however, that much basic research and clinical studies are needed before this potential can be realized. CONCLUSIONS: Whereas IMRT may have initiated the beginning of the end relative to physical conformality in radiotherapy, biological imaging may launch the beginning of a new era of biological conformality. In combination, these approaches constitute MD-CRT that may further improve the efficacy of cancer radiotherapy in the new millennium.

Fluorodeoxyglucose F18↗

Relative profile and dose verification of intensity-modulated radiation therapy.

PURPOSE: To develop a quality assurance (QA) procedure to assess the intensity profile and dosimetry for intensity-modulated (IM) treatment fields using electronic portal imaging devices (EPIDs). METHODS AND MATERIALS: A series of rapidly acquired (approximately 1/sec) portal images are summed and converted to dose. For relative intensity QA, the intended profile is subtracted point-by-point from the measured profile forming a series of error values. The standard deviation, sigma, of the errors, a measure of the goodness of the match, is minimized by applying a normalization and uniform scatter subtraction from the measured profile. For dose verification (dose to isocenter), an empirically determined phantom-correction factor is added to incorporate the effect of patient presence on EPID readings. Seventy prostate treatment fields were used in a phantom study to verify these approaches. Sensitivity was studied by creating artificial mismatches. RESULTS: The average sigma for relative profile verification is 3.3% (percentage of average intended intensity) whereas artificial mismatches resulted in sigma values from 5% to 27%. The average isocentric dose calculated from EPID readings is 1.001 relative to the planned dose with a standard deviation of 0.018. CONCLUSIONS: An EPID can be used for profile verification and absolute isocentric dose measurement for IM fields.

Algorithms↗

Late rectal toxicity after conformal radiotherapy of prostate cancer (I): multivariate analysis and dose-response.

PURPOSE: The purpose of this paper is to use the outcome of a dose escalation protocol for three-dimensional conformal radiation therapy (3D-CRT) of prostate cancer to study the dose-response for late rectal toxicity and to identify anatomic, dosimetric, and clinical factors that correlate with late rectal bleeding in multivariate analysis. METHODS AND MATERIALS: Seven hundred forty-three patients with T1c-T3 prostate cancer were treated with 3D-CRT with prescribed doses of 64.8 to 81.0 Gy. The 5-year actuarial rate of late rectal toxicity was assessed using Kaplan-Meier statistics. A retrospective dosimetric analysis was performed for patients treated to 70.2 Gy (52 patients) or 75.6 Gy (119 patients) who either exhibited late rectal bleeding (RTOG Grade 2/3) within 30 months after treatment (i.e., 70.2 Gy-13 patients, 75. 6 Gy-36 patients) or were nonbleeding for at least 30 months (i.e., 70.2 Gy-39 patients, 75.6 Gy-83 patients). Univariate and multivariate logistic regression was performed to correlate late rectal bleeding with several anatomic, dosimetric, and clinical variables. RESULTS: A dose response for >/= Grade 2 late rectal toxicity was observed. By multivariate analysis, the following factors were significantly correlated with >/= Grade 2 late rectal bleeding for patients prescribed 70.2 Gy: 1) enclosure of the outer rectal contour by the 50% isodose on the isocenter slice (i.e., Iso50) (p < 0.02), and 2) smaller anatomically defined rectal wall volume (p < 0.05). After 75.6 Gy, the following factors were significant: 1) smaller anatomically defined rectal wall volume (p < 0.01), 2) higher rectal D(max) (p < 0.01), 3) enclosure of rectal contour by Iso50 (p < 0.01), 4) patient age (p = 0.02), and 5) history of diabetes mellitus (p = 0.04). In addition to these five factors, acute rectal toxicity was also significantly correlated (p = 0.05) with late rectal bleeding when patients from both dose groups were combined in multivariate analysis. CONCLUSION: A multivariate logistic regression model is presented which describes the probability of developing late rectal bleeding after conformal irradiation of prostate cancer. Late rectal bleeding correlated with factors which may indicate that a greater fractional volume of rectal wall was exposed to high dose, such as smaller rectal wall volume, inclusion of the rectum within the 50% isodose on the isocenter slice, and higher rectal D(max).

Analysis of Variance↗

The catalytic subunit of DNA-dependent protein kinase selectively regulates p53-dependent apoptosis but not cell-cycle arrest.

DNA damage induced by ionizing radiation (IR) activates p53, leading to the regulation of downstream pathways that control cell-cycle progression and apoptosis. However, the mechanisms for the IR-induced p53 activation and the differential activation of pathways downstream of p53 are unclear. Here we provide evidence that the catalytic subunit of DNA-dependent protein kinase (DNA-PKcs) serves as an upstream effector for p53 activation in response to IR, linking DNA damage to apoptosis. DNA-PKcs knockout (DNA-PKcs-/-) mice were exposed to whole-body IR, and the cell-cycle and apoptotic responses were examined in their thymuses. Our data show that IR induction of apoptosis and Bax expression, both mediated via p53, was significantly suppressed in the thymocytes of DNA-PKcs-/- mice. In contrast, IR-induced cell-cycle arrest and p21 expression were normal. Thus, DNA-PKcs deficiency selectively disrupts p53-dependent apoptosis but not cell-cycle arrest. We also confirmed previous findings that p21 induction was attenuated and cell-cycle arrest was defective in the thymoctyes of whole body-irradiated Atm-/- mice, but the apoptotic response was unperturbed. Taken together, our results support a model in which the upstream effectors DNA-PKcs and Atm selectively activate p53 to differentially regulate cell-cycle and apoptotic responses. Whereas Atm selects for cell-cycle arrest but not apoptosis, DNA-PKcs selects for apoptosis but not cell-cycle arrest.

Animals↗

Clinical experience with intensity modulated radiation therapy (IMRT) in prostate cancer.

PURPOSE: To compare acute and late toxicities of high-dose radiation for prostate cancer delivered by either conventional three-dimensional conformal radiation therapy (3D-CRT) or intensity modulated radiation therapy (IMRT). MATERIALS AND METHODS: Between September 1992 and February 1998, 61 patients with clinical stage T1c- T3 prostate cancer were treated with 3D-CRT and 171 with IMRT to a prescribed dose of 81 Gy. To quantitatively evaluate the differences between conventional 3D-CRT and IMRT, 20 randomly selected patients were planned concomitantly by both techniques and the resulting treatment plans were compared. Acute and late radiation-induced morbidity was evaluated in all patients and graded according to the Radiation Therapy Oncology Group toxicity scale. RESULTS: Compared with conventional 3D-CRT, IMRT improved the coverage of the clinical target volume (CTV) by the prescription dose and reduced the volumes of the rectal and bladder walls carried to high dose levels (P<0.01), indicating improved conformality with IMRT. Acute and late urinary toxicities were not significantly different for the two methods. However, the combined rates of acute grade 1 and 2 rectal toxicities and the risk of late grade 2 rectal bleeding were significantly lower in the IMRT patients. The 2-year actuarial risk of grade 2 bleeding was 2% for IMRT and 10% for conventional 3D-CRT (P<0.001). CONCLUSIONS: The data demonstrate the feasibility and safety of high-dose IMRT for patients with localized prostate cancer and provide a proof-of-principle that this method improves dose conformality relative to tumor coverage and exposure to normal tissues.

Aged↗

Computerized video time-lapse analysis of apoptosis of REC:Myc cells X-irradiated in different phases of the cell cycle.

Asynchronous rat embryo cells expressing Myc were followed in 50 fields by computerized video time lapse (CVTL) for three to four cycles before irradiation (4 Gy) and then for 6-7 days thereafter. Pedigrees were constructed for single cells that had been irradiated in different parts of the cycle, i.e. at different times after they were born. Over 95% of the cell death occurred by postmitotic apoptosis after the cells and their progeny had divided from one to six times. The duration of the process of apoptosis once it was initiated was independent of the phase in which the cell was irradiated. Cell death was defined as cessation of movement, typically 20-60 min after the cell rounded with membrane blebbing, but membrane rupture did not occur until 5 to 40 h later. The times to apoptosis and the number of divisions after irradiation were less for cells irradiated late in the cycle. Cells irradiated in G(1) phase divided one to six times and survived 40-120 h before undergoing apoptosis compared to only one to two times and 5-40 h for cells irradiated in G(2) phase. The only cells that died without dividing after irradiation were irradiated in mid to late S phase. Essentially the same results were observed for a dose of 9.5 Gy, although the progeny died sooner and after fewer divisions than after 4 Gy. Regardless of the phase in which they were irradiated, the cells underwent apoptosis from 2 to 150 h after their last division. Therefore, the postmitotic apoptosis did not occur in a predictable or programmed manner, although apoptosis was associated with lengthening of both the generation time and the duration of mitosis immediately prior to the death of the daughter cells. After the non-clonogenic cells divided and yielded progeny entering the first generation after irradiation with 4 Gy, 60% of the progeny either had micronuclei or were sisters of cells that had micronuclei, compared to none of the progeny of clonogenic cells having micronuclei in generation 1. However, another 20% of the non-clonogenic cells had progeny with micronuclei appearing first in generation 2 or 3. As a result, 80% of the non-clonogenic cells had progeny with micronuclei. Furthermore, cells with micronuclei were more likely to die during the generation in which the micronuclei were observed than cells not having micronuclei. Also, micronuclei were occasionally observed in the progeny from clonogenic cells in later generations at about the same time that lethal sectoring was observed. Thus cell death was associated with formation of micronuclei. Most importantly, cells irradiated in late S or G(2) phase were more radiosensitive than cells irradiated in G(1) phase for both loss of clonogenic survival and the time of death and number of divisions completed after irradiation. Finally, the cumulative percentage of apoptosis scored in whole populations of asynchronous or synchronous populations, without distinguishing between the progeny of individually irradiated cells, underestimates the true amount of apoptosis that occurs in cells that undergo postmitotic apoptosis after irradiation. Scoring cell death in whole populations of cells gives erroneous results since both clonogenic and non-clonogenic cells are dividing as non-clonogenic cells are undergoing apoptosis over a period of many days.

Animals↗

Deep inspiration breath-hold technique for lung tumors: the potential value of target immobilization and reduced lung density in dose escalation.

PURPOSE/OBJECTIVE: This study evaluates the dosimetric benefits and feasibility of a deep inspiration breath-hold (DIBH) technique in the treatment of lung tumors. The technique has two distinct features--deep inspiration, which reduces lung density, and breath-hold, which immobilizes lung tumors, thereby allowing for reduced margins. Both of these properties can potentially reduce the amount of normal lung tissue in the high-dose region, thus reducing morbidity and improving the possibility of dose escalation. METHODS AND MATERIALS: Five patients treated for non-small cell lung carcinoma (Stage IIA-IIIB) received computed tomography (CT) scans under 4 respiration conditions: free-breathing, DIBH, shallow inspiration breath-hold, and shallow expiration breath-hold. The free-breathing and DIBH scans were used to generate 3-dimensional conformal treatment plans for comparison, while the shallow inspiration and expiration scans determined the extent of tumor motion under free-breathing conditions. To acquire the breath-hold scans, the patients are brought to reproducible respiration levels using spirometry, and for DIBH, modified slow vital capacity maneuvers. Planning target volumes (PTVs) for free-breathing plans included a margin for setup error (0.75 cm) plus a margin equal to the extent of tumor motion due to respiration (1-2 cm). Planning target volumes for DIBH plans included the same margin for setup error, with a reduced margin for residual uncertainty in tumor position (0.2-0.5 cm) as determined from repeat fluoroscopic movies. To simulate the effects of respiration-gated treatments and estimate the role of target immobilization alone (i.e., without the benefit of reduced lung density), a third plan is generated from the free-breathing scan using a PTV with the same margins as for DIBH plans. RESULTS: The treatment plan comparison suggests that, on average, the DIBH technique can reduce the volume of lung receiving more than 25 Gy by 30% compared to free-breathing plans, while respiration gating can reduce the volume by 18%. The DIBH maneuver was found to be highly reproducible, with intra breath-hold reproducibility of 1.0 (+/- 0.9) mm and inter breath-hold reproducibility of 2.5 (+/- 1.6) mm, as determined from diaphragm position. Patients were able to perform 10-13 breath-holds in one session, with a comfortable breath-hold duration of 12-16 s. CONCLUSION: Patients tolerate DIBH maneuvers well and can perform them in a highly reproducible fashion. Compared to conventional free-breathing treatment, the DIBH technique benefits from reduced margins, as a result of the suppressed target motion, as well as a decreased lung density; both contribute to moving normal lung tissue out of the high-dose region. Because less normal lung tissue is irradiated to high dose, the possibility for dose escalation is significantly improved.

Aged↗