Search PubMed⌕ Search

Biomedical subjects

C Benjamin

Publications and source records attributed to C Benjamin.

49 records · Page 3Linked to original sources

Population heteromorphisms of Ag-stained nucleolus organizer regions (NORs) in the acrocentric chromosomes of East Indians.

The nucleolar organizer regions (NORs) of acrocentric chromosomes in 70 normal East Indians were examined by Ag-staining (NSG) and acridine orange reverse banding (RFA) techniques. The Ag-stainability of NORs was variable from one individual to another but characteristics were constant within each individual. The average modal number of Ag-positive NORs per individual was eight. A racial difference in the expression of NORs is suggested. To study the heteromorphism of NORs, the NSG technique was found to be more useful than RFA. Furthermore, it is concluded that there is no direct relationship between a heteromorphism of NORs identified by NSG and that identified by the RFA technique. Quantitative data on these differences is provided. In addition NOR-regions are classified into five sizes namely; very large, large, medium, small, and very small using subjectively defined criteria.

Acridine Orange↗

Myocardial technetium 99m-labeled sestamibi single-photon emission computed tomographic imaging in the detection of coronary artery disease: comparison between early (15 minutes) and delayed (60 minutes) imaging.

BACKGROUND: Previous studies have demonstrated that there is a "partial" myocardial redistribution of 99mTc-labeled sestamibi (MIBI) between 1 and 3 hours after intravenous injection at stress. The purpose of this prospective study was to compare MIBI single-photon emission computed tomographic (SPECT) imaging performed 15 and 60 minutes after the injection at stress in the detection of coronary artery disease. METHODS AND RESULTS: Thirty-five patients with coronary artery disease (26 underwent coronary angiography and 23 had a positive 201Tl study result) were included in this study. SPECT imaging started 15 minutes after the injection of 25 to 30 mCi MIBI at peak stress (180-degree arc, 32 angles, 25 sec/view, and high-resolution collimator). Patients underwent reimaging at 60 minutes according to the same protocol and with the same gamma camera. A rest study was obtained 75 minutes after the injection of MIBI (25 to 30 mCi) at rest, 48 hours later. Images (divided for a total of 19 segments per patient) were interpreted by two blinded observers for patient diagnosis and segmental comparison. The patient diagnosis was the same for the two protocols: normal = 3, ischemia = 27, and scar = 5. The segmental agreement (kappa = 0.90) was 632/665 (95.0%). The imaging performed at 15 minutes detected normal, ischemia, and scar in 413, 189, and 63 segments, respectively, whereas the imaging performed at 60 minutes detected 422, 180, and 63 segments, respectively (difference not significant). The early and delayed images were placed side by side for subjective comparison of the extent of the defect. Early imaging showed slightly larger defects in six patients, equal defects in 24 patients, and slightly smaller defects in five patients. Ischemic/normal wall ratios were 0.67 +/- 0.16 at 15 minutes and 0.68 +/- 0.15 at 60 minutes. CONCLUSIONS: There is no clinically significant difference between SPECT imaging performed at 15 minutes or 60 minutes after the injection of MIBI at stress. Furthermore, this study showed that it is feasible to obtain good-quality MIBI images even 15 minutes after the injection at stress.

Adult↗

Comparison between the end-diastolic images and the summed images of gated 99mTc-sestamibi SPECT perfusion study in detection of coronary artery disease in women.

BACKGROUND: End-diastolic images (EDI) can be easily derived from technetium 99m-sestamibi gated single photon emission computed tomography (SPECT) perfusion study (SGS). This may reduce the effect of myocardial wall thickening during systole and potentially improve the sensitivity of radionuclide perfusion imaging, especially in patients with small hearts. METHODS: This prospective study was conducted in 53 consecutive female patients to compare the diagnostic accuracy of EDI with that of the summed images (SI) of SGS. Fifty-three patients with suspected coronary artery disease (CAD), scheduled for coronary angiography within 2 months, were evaluated with SGS. Treadmill stress testing was used in 28 patients, and dipyridamole injection was used in the remaining 25 patients. A 2-day protocol was used as follows: stress test with 25 to 30 mCi of 99mTc-sestamibi and a rest study performed at least 24 hours later with the same dose. Sixteen frames per cardiac cycle were acquired for both the rest and the stress studies. Three end-diastolic frames were used for EDI, and all the 16 frames were summed for SI. SI and EDI data reconstruction were interpreted by 3 experienced blinded observers (consensus reading) during two distinct reading sessions, one with SI alone and the second with EDI alone. The heart was divided into 17 segments. RESULTS: Coronary angiography showed > or = 50% stenoses in 1 or more major coronary arteries in 38 patients and was normal in 15 patients. The sensitivity was 73.7% (28/38) and 84.2% (32/38), respectively, for SI and EDI. Three of 4 patients with CAD not detected by SI but seen with EDI were considered to have relatively small hearts. The specificity was 86.7% (13/15) and 80.0% (12/15) for SI and EDI, respectively. On a total of 901 segments, 106 ischemic defects were detected by SI and 173 by EDI (P = .001). The segmental agreement between the two techniques was 88.6% (798/901 segments). CONCLUSION: EDI showed more ischemic defects than SI, and there was also a nonsignificant trend toward an improved sensitivity of EDI in comparison to SI in detection of coronary artery disease in women, especially in patients with small hearts. EDI may be a useful adjunct to the standard perfusion imaging with SGS in such a clinical situation.

Adult↗