Influence of field size on a PTW type 23342 plane-parallel ionization chamber's response.

The response of a PTW type 23342 plane-parallel ionization chamber, both in air and in phantom, was evaluated for x-ray tube potentials between 30 and 100 kV and radiation field diameters ranging from 30 to 70 mm. The experiments were performed with a calibrated Pantak x-ray machine and made use of the same set of x-ray qualities adopted by the PTB primary laboratory for the calibration of such chambers. A Plexiglas phantom (1.18 g cm(-3)) 110 mm long, 110 mm wide, and 80 mm deep was used for phantom measurements. X-ray qualities were characterized by using 99.99% pure aluminum filters. On the basis of the IAEA's TRS 398, the article discusses the dependence of the plane-parallel ionization chamber readings with field size in air and in phantom, its implication with regard to clinical dosimetry, cross-calibration, and dissemination of calibration factors.

Equipment Design↗

Absorbed dose determination with plane-parallel chambers.

According to IAEA TRS 398 recommendations the determination of absorbed dose with plane-parallel ionisation chambers calibrated in terms of N(K,Q0) can be done using N(D,W,Q0) = (M(Q0)(free air)/M(Q0)(surface)) N(K,Q0)B[(mu(en)/rho)(W,air)](free air) P(Q0). This equation takes into account only the scattering from the stem of the soft ionisation chamber, not the total scattering published in the scientific literature. That makes it difficult to perform dosimetry with field sizes different from those used in the standardisation laboratory to calibrate the chamber. This paper describes a method to calculate D(W,Q0) by using either N(K,Q0) or N(D,W,Q0) for different radiation field sizes.

Air↗

Calibration of a NaI spectrometer in dose equivalent quantities.

A sodium iodide spectrometer was calibrated in terms of dose equivalent quantities. The detector was irradiated with a known dose (dose equivalent) at 12 ISO x-ray qualities between 33 keV and 248 keV. The method of calibration is based on the relationship between the considered dose equivalent delivered by each x-ray quality and the linear combination of the number of counts in a set of six fixed energy ranges. This procedure allows for the evaluation of the effective dose equivalent, the whole-body dose equivalent and the testes dose equivalent for parallel irradiation with a maximum and minimum relative deviation from the reference values of +11% and -21%, respectively.

Calibration↗

A graphite transmission ionization chamber.

A pancake-type transmission chamber made of high-purity graphite and open to the atmosphere has been designed and constructed at the Secondary Standard Dosimetry Laboratory (SSDL-Rio de Janeiro). Tests performed on the chamber following the International Electrotechnical Commission recommendations indicate that its performance characteristics are comparable to those expected from a secondary standard ionization chamber.

Cobalt Radioisotopes↗