Eigenmobilities in background electrolytes for capillary zone electrophoresis. I. System eigenpeaks and resonance in systems with strong electrolytes.

A background electrolyte system for capillary zone electrophoresis which is composed of three strong univalent ionic constituents is investigated. The ion 1 is considered as a counter-ion and two ions, 2 and 3, are considered as co-ions in relation to the analyte ion 4. We investigate the linearized model of electromigration in such a system and calculate the eigenvalues of a corresponding matrix. The model is formulated in such a way that the eigenvalues of the system are certain mobilities, which we call eigenmobilites, which characterize specific features of the electtrophoretic migration. One of the eigenmobilities is the system eigenmobility u(s) causing the rise of the system peak, called here the system eigenpeak. A situation when the analyte has the same mobility as the system eigenmobility, u(4) = u(s), is analyzed in detail. We show that it leads to the resonance-the mutual jump in the concentration profile of both co-ions, 2 and 3, has a shape of the spatial derivation of the originally sampled analyte profile and, moreover, it grows linearly with time. After a sufficiently long time it can be "amplified" to any value. The resonance has then a great impact on signals of indirect detection methods, like indirect UV detection or conductivity detection. In the framework of the linearized model the relative velocity slope S(x), a measure of electromigration dispersion, is expressed as S(x) = F(u(1) + u(4))(u(2) - u(4))(u(3) - u(4))/[u(4)(u(s) - u(4))], where u(i) is the mobility of the ith ion and F is the Faraday constant. As in practice the concentration of the analyte is not infinitely small and has a certain finite value, the analyte will be at the resonance severely dispersed to a much broader spatial interval. When a specific detector is used, the signal of such an analyte can apparently be missed without any notice.

Electrolytes↗

Determination of electroosmotic flow mobility with a pressure-mediated dual-ion technique for capillary electrophoresis with conductivity detection using organic solvents.

A method is described for the indirect determination of the mobility of the electroosmotic flow (EOF), which can be carried out within a few minutes even for very low mobilities. It is independent of the direction of the EOF. It is based on the comparison of the measured mobilities of two oppositely charged reference ions (tetraphenylphosphonium and tetraphenylborate) with given mobilities in different organic solvents (methanol, acetonitrile, N,N-dimethylformamide, N,N-dimethylacetamide, propylene carbonate) at ionic strengths between 5 and 50 mM. The method is based on the sequential movement of the reference ions in a three-step process: first by a laminar flow to a certain position in the separation capillary, followed by electromigration due to application of voltage, and pressurised migration towards the detector. In this way the total mobilities of the reference ions can be determined from their residence times, and the difference to their known actual mobilities gives the mobility of the EOF. The method avoids misinterpretations caused by system- and eigen-peaks, which often bias the results especially when a conductivity detector is used. The method is suitable for all solvents, and is an advantage especially for organic and mixed aqueous-organic background electrolytes with high UV absorbance.

Electric Conductivity↗

Propylene carbonate as a nonaqueous solvent for capillary electrophoresis: mobility and ionization constant of aliphatic amines.

The two properties of aliphatic amines were investigated in propylene carbonate as solvent that are decisive for capillary electrophoretic migration: the actual mobilities and the pKa* values. Solutes were eight primary, secondary, and tertiary amines. Roughly, the actual ionic mobilities of the ammonium ions are inversely proportional to the solvent viscosity, fairly obeying Walden's rule. The pKa* values of the cation acids, HB+ (the corresponding acids of the amines, B), were related to the conventional pH* scale of the buffers. Determined from the effective mobilities as a function of the pH*, they are increased by approximately 7 units compared to water. This increase was interpreted based on the concept of the standard free energy of transfer of the individual species in the acid-base equilibrium. The corresponding medium effect on the proton, log mgammaH+ (the logarithm of the transfer activity coefficient mgammaH+) is approximately +8. The medium effect on the free base, B, was obtained from solubility data; it is about -1 and smaller. Plausible values for the medium effect on the cation HB+ (-1 to -2) lead to a sum of the increments, which corresponds with the overall effect, expressed by the change in pKa*. Examination of the individual contributions shows that the drastically lower basicity of propylene carbonate compared to water is mainly responsible for the increase in pKa upon transfer of the acid-base equilibrium of aliphatic ammonium/amine from the aqueous to the organic solvent.

Amines↗

Electrophoretic mobilities of large organic ions in nonaqueous solvents: determination by capillary electrophoresis in propylene carbonate, N,N-dimethylformamide, N,N,-dimethylacetamide, acetonitrile and methanol.

The mobilities of the monocharged permanent tertraphenylphosphonium cation and tetraphenylborate anion are determined by capillary zone electrophoresis in different organic solvents as a function of the ionic strength, I, of the background electrolyte. The nonaqueous solvents are propylene carbonate (PC), N,N-dimethylformamide (DMF), N,N,-dimethylacetamide (DMA), acetonitrile (MeCN) and methanol (MeOH). The ionic strength is between 5 and 50 mmol/L. The mobility as a function of I is in good agreement with the theory of Debye, Hückel and Onsager (DHO), extended by the ion size parameter as introduced by Falkenhagen and Pitts. The values of the limiting DHO slopes of the mobility vs. I curves (the slopes express the influence of the solvent on the reduction of the mobility with increase of I) decrease in the order MeCN > MeOH > DMF > DMA > PC. Absolute mobilities (obtained by extrapolation to I = 0) of a particular ion differ by a factor of about 7 between the solvents. However, constancy within 10% is observed for their Walden products (the absolute mobility multiplied with the solvent's macroviscosity). The role of dielectric friction on the mobility of the present monocharged, large analyte ions is discussed according to the theory of Hubbard and Onsager. Based on the radii of the ions, the static permittivity of the solvent and its permittivity at infinite frequency, and the relaxation time of polarization, an equal contribution of dielectric and hydrodynamic friction is predicted in MeOH as solvent. Experimental data are in contrast to this prediction, indicating the overestimation of dielectric friction, and the dominance of hydrodynamic friction on the migration of the analyte ions in all solvents under consideration.

Acetamides↗

Optimization of background electrolytes for capillary electrophoresis: II. Computer simulation and comparison with experiments.

A mathematical and computational model described in the previous paper (Gas, B., Coufal, P., Jaros, M., Muzikár, J., Jelínek, L., J. Chromatogr. A 2001, 905, 269-279) is adapted, algorithmized, and a computer program PeakMaster having a status of freeware (http://natur.cuni.cz/ approximately gas) is introduced. The model enables optimization of background electrolyte (BGE) systems for capillary zone electrophoresis. The model allows putting to use uni- or di- or trivalent electrolytes and allows also for modeling highly acidic or alkaline BGEs. It takes into account the dependence of ionic mobilities and dissociation of weak electrolytes on the ionic strength. The model calculates the effective mobility of analytes and predicts parameters of the system that are experimentally available, such as the transfer ratio, which is a measure of the sensitivity in the indirect UV detection or the molar conductivity detection response, which expresses the sensitivity of the conductivity detection. Further, the model enables evaluation of a tendency of the analyte to undergo electromigration dispersion or peak broadening. The suitability of the model is verified by comparison of the predicted results with experiments, even under conditions that are far from ideal (under extreme pH and a high ionic strength).

Algorithms↗

Optimization of the high-frequency contactless conductivity detector for capillary electrophoresis.

Two constructions of the high-frequency contactless conductivity detector that are fitted to the specific demands of capillary zone electrophoresis are described. The axial arrangement of the electrodes of the conductivity cell with two cylindrical electrodes placed around the outer wall of the capillary column is used. We propose an equivalent electrical model of the axial contactless conductivity cell, which explains the features of its behavior including overshooting phenomena. We give the computer numerical solution of the model enabling simulation of real experimental runs. The role of many parameters can be evaluated in this way, such as the dimension of the separation channel, dimension of the electrodes, length of the gap between electrodes, influence of the shielding, etc. The conception of model allows its use for the optimization of the construction of the conductivity cell, either in the cylindrical format or in the microchip format. The ability of the high-frequency contactless conductivity detector is demonstrated on separation of inorganic ions.

Cations↗

Peak broadening in microchip electrophoresis: a discussion of the theoretical background.

A review on peak (band, zone) broadening in electromigration separation methods is presented, mainly covering articles published between the begining of 2000 and middle of 2002. Most attention is drawn to work dealing with microchip electrophoresis performed in micrototal analysis systems (microTAS) or the lab-on-a-chip, but many of the results are significant for capillary zone electrophoresis in general. The paper reviews the theoretical background of the peak dispersion due to the geometry of the separation channel, the transversal nonhomogeneity of the electroosmootic flow, and electromigration dispersion (sample overload) connected with the occurrence of the system zones (system peaks, system eigenpeaks).