Kohlrausch regulating function and other conservation laws in electrophoresis.

The Kohlrausch regulating function (KRF) is a conservation law (conservation function), which is held in electrophoresis and which enables calculation of the so-called adjusted concentrations of constituents. The KRF is not the only conservation function and, depending on the complexity of the electrophoretic system, other conservation laws may be obeyed having a broader range of applicability. The conservation laws are tightly related to system eigenmobilities and system zones (system peaks). In principle, no system eigenmobility is exactly zero, but in most practical cases at least one system's eigenmobility is close to zero. The existence of the close-to-zero eigenmobility inherently points to the existence of a conservation function and a system zone which is stationary. The stationary system zone is called injection zone, stagnant zone, water peak, or solvent dip. Electrophoretic (electromigration) systems can be divided into two types: (i) conservation systems, in which the absolute value of at least one system eigenmobility is close to zero and where at least one conservation law is obeyed and (ii) nonconservation systems, where no system eigenmobility is close to zero and no conservation law is obeyed. The paper reviews work dealing with conservation functions in electromigration, derives some "historical" conservation functions in a new way, derives several conservation functions for systems of multivalent electrolytes, and discusses electrophoretic systems that have nonconservation behavior. In some typical instances, the conservation functions are simulated by means of a dynamic simulation tool and depicted graphically.

Chemical Phenomena↗

Determination of limiting mobilities and dissociation constants of 21 amino acids by capillary zone electrophoresis at very low pH.

The dependence of the effective electrophoretic mobility on pH of the background electrolyte was experimentally determined by capillary zone electrophoresis (CZE) for cationic forms of amino acids. The pH of the background electrolytes was in the highly acidic range, 1.6-2.6 pH units, to ensure a high degree of protonation of the amino acids. Poly(vinyl alcohol) was added to the background electrolytes to avoid possible adsorption of the analytes at the inner capillary wall. Non-linear regression of the experimental data was applied to obtain the parameters of the relevant regression functions--the actual mobilities and mixed dissociation constants corresponding to the actual ionic strength. The extended Onsager and Debye-Hückel law was used to calculate the limiting mobilities and thermodynamic dissociation constants. The comparison of the experimental electropherogram with the computer prediction by PeakMaster using the determined data is presented for the selected sample of amino acids.

Amino Acids↗

Oscillating electrolytes.

Chemical oscillations are driven by the gradient of the chemical potential so that they can appear in systems where the substances are not in chemical equilibrium. We show that under the influence of the electric field, concentrations of electrically charged substances in solutions can oscillate even if the system is in chemical equilibrium. The driving force here is not the gradient of the chemical potential but rather the gradient of the electric potential. Utilizing CE we found periodic structures invoked by the application of a constant driving voltage in BGEs possessing complex eigenmobilities. By analogy with the behavior of dynamic systems, complex eigenmobilities implicate that the system will be unstable. Instead of forming system zones (system peaks) in the separation channel (capillary) the originally uniform concentration of electrolyte constituents becomes periodically disturbed when the electric current passes through it.

Electrolytes↗

Simul 5 - free dynamic simulator of electrophoresis.

We introduce the mathematical model of electromigration of electrolytes in free solution together with free software Simul, version 5, designed for simulation of electrophoresis. The mathematical model is based on principles of mass conservation, acid-base equilibria, and electroneutrality. It accounts for any number of multivalent electrolytes or ampholytes and yields a complete picture about dynamics of electromigration and diffusion in the separation channel. Additionally, the model accounts for the influence of ionic strength on ionic mobilities and electrolyte activities. The typical use of Simul is: inspection of system peaks (zones), stacking and preconcentrating analytes, resonance phenomena, and optimization of separation conditions, in either CZE, ITP, or IEF.

Computer Simulation↗

Eigenmobilities in background electrolytes for CZE. V. Intensity (amplitudes) of system peaks.

We present a mathematical model of CZE based on the concept of eigenmobilities - the eigenvalues of matrix M tied to the linearized governing equations of electromigration, and the spectral decomposition of matrix M into matrices of amplitudes P(j). Any peak in an electropherogram, regardless of whether it is an analyte peak or a system peak (system zone), is matched with its matrix P(j). This enables calculation of the peak parameters, such as the transfer ratio and the molar conductivity detection response (which give the indirect detection signal and the conductivity detection signal, respectively), when the initial disturbance caused by the injection of the sample is known. We also introduce new quantities, such as the generalized transfer ratio and the conductivity response of system zones, and show how the amplitude (intensity, area) of the analyte peaks and the system peaks can be calculated. We offer a free software, PeakMaster (http://www.natur.cuni.cz/gas), which yields this information in a user-friendly way.

Acetic Acid↗

Analyte and system eigenpeaks in nonaqueous capillary zone electrophoresis: theoretical description and experimental confirmation with methanol as solvent.

A mathematical model developed for aqueous solutions and adapted to methanol as solvent was applied to predict the electromigration characteristics of analytes and background electrolytes in capillary zone electrophoresis. These characteristics are the effective mobility, and the tendency of the analyte to undergo peak-broadening due to electromigration dispersion. The input parameters for calculation like limiting mobilities and dissociation constants were experimentally determined or taken from the literature. By the aid of the model, the molar response for conductivity detection was calculated as well as the transfer ratio when indirect UV detection was used. They allow depicting the electropherogram by computer simulation. An additional important program output is the prediction of the occurrence of system- or eigenpeaks that mimic peaks of analytes or electroosmotic flow markers. The measured electropherograms were in agreement with those theoretically predicted. Deviations were attributed to ion pairing in methanolic solutions, which was not implemented in the model.

Cations↗

Conductivity detection in capillary zone electrophoresis: inspection by PeakMaster.

A simple rule stating that the signal in conductivity detection in capillary zone electrophoresis is proportional to the difference between the analyte mobility and mobility of the background electrolyte (BGE) co-ion is valid only for systems with fully ionized electrolytes. In zone electrophoresis systems with weak electrolytes both conductivity signal and electromigration dispersion of analyte peaks depend on the conductivity and pH effects. This allows optimization of the composition of BGEs to give a good conductivity signal of analytes while still keeping electromigration dispersion near zero, regardless of the injected amount of sample. The demands to achieve minimum electromigration dispersion and high sensitivity in conductivity detection can be accomplished at the same time. PeakMaster software is used for inspection of BGEs commonly used for separation of sugars (carbohydrates, saccharides) at highly alkaline pH. It is shown that the terms direct and indirect conductivity detection are misleading and should not be used.

Electric Conductivity↗

Dynamics of interconversion of enantiomers in chiral separation systems: a novel approach for determination of all rate constants involved in the interconversion.

When enantiomers separated by chromatography or capillary electrophoresis undergo interconversion reaction (enantiomerization) during the separation, it leads to a typical detection pattern: two individual peaks of the separated enantiomers are connected with a plateau consisting of a mixture of both separated enantiomers. We propose a separation method for determination of all individual rate constants (or inversion barriers) of the interconversion. The method enables to distinguish which part of interconversion takes place in the free (unbound) form of the analyte and which part in the complexed (bound) form. Further, we propose a complete dynamic model of capillary electrophoresis of interconverting enantiomers based on solving a complete set of continuity equations for all constituents of the separation system together with complexation and acid-base equilibria. This allows a simulation of both linear and nonlinear mode of separation and understanding all processes taking place in such enantioseparation systems. We demonstrate the applicability of the method on determination of the rate constants of interconversion of oxazepam enantiomers separated in systems with charged cyclodextrin chiral selectors.

Acid-Base Equilibrium↗

Determination of cationic mobilities and pKa values of 22 amino acids by capillary zone electrophoresis.

The effective mobilities of the cationic forms of common amino acids--mostly proteinogenic--were determined by capillary zone electrophoresis in acidic background electrolytes at pH between 2.0 and 3.2. The underivatized amino acids were detected by the double contactless conductivity detector. Experimentally measured effective mobilities were fitted with the suitable regression functions in dependence on pH of the background electrolyte. The parameters of the given regression function corresponded to the values of the actual mobilities and the mixed dissociation constants (combining activities and concentrations) of the compound related to the actual ionic strength. McInnes approximation and Onsager theory were used to obtain thermodynamic dissociation constants (pK(a)) and limiting (absolute) ionic mobilities.

Amino Acids↗

Effects of partial/asymmetrical filling of micelles and chiral selectors on capillary electrophoresis enantiomeric separation: generation of a gradient.

The effect of several experimental parameters on enantiomeric separations in micellar capillary electrophoresis (MCE) was studied. A model separation system was tested. It was composed of an acidic phosphate buffer with sodium dodecyl sulfate (SDS) and hydroxypropyl-beta-cyclodextrin (HP-beta-CD) as the chiral selector. A substituted angelicin was used as a chiral analyte. Changes in the concentration of SDS micelles/SDS monomers in the presence of HP-beta-CD and their impact on the enantioselective separation were investigated. Variation of the composition of electrolytes in the individual compartments of the separation system (inlet vial, capillary, and outlet vial) affected both the migration times and the resolution of the enantiomers. Current vs. time dependencies also were monitored during the separations. A mathematical model of electromigration in micellar systems with chiral selector present was proposed and a computer simulation was used to explain the observed phenomena and to confirm the generation of a CD/SDS-micelle concentration gradient under certain experimental conditions. This is the reported first attempt of a computer simulation of the complex, dynamic chiral environment of the CD-SDS-MCE system.

2-Hydroxypropyl-beta-cyclodextrin↗

Eigenmobilities in background electrolytes for capillary zone electrophoresis: III. Linear theory of electromigration.

A mathematical model of capillary zone electrophoresis (CZE) based on the conception of eigenmobilities, which are the eigenvalues of a matrix M tied to the linearized governing equations is presented. The model considers CZE systems, where constituents, either analytes or components of the background electrolyte (BGE), are weak electrolytes--acids, bases, or ampholytes. There is no restriction on the number of components nor on the valence of the constituents nor on pH of the BGE. An electrophoretic system with N constituents has N eigenmobilities. In most BGEs one or two eigenmobilities are very close to zero so their corresponding eigenzones move very slowly. However, there are BGEs where no eigenmobility is close to zero. The mathematical model further provides: the transfer ratio, the molar conductivity detection response, and the relative velocity slope. This allows the assessment of the indirect detection, conductivity detection and peak broadening (distortion) due to electromigration dispersion. Also, we present a spectral decomposition of the matrix M to matrices allowing the assessment of the amplitudes of system eigenpeaks (system peaks). Our model predicted the existence of BGEs having no stationary injection zone (or water zone, gap, peak, dip). A common practice of using the injection zone as a marker of the electroosmotic flow must fail in such electrolytes.

Buffers↗

Eigenmobilities in background electrolytes for capillary zone electrophoresis: IV. Computer program PeakMaster.

We are introducing a computer implementation of the mathematical model of zone electrophoresis (CZE) described in Stedry, M., Jaros, M., Hruska, V., Gas, B., Electrophoresis 2004, 25, 3071-3079 program PeakMaster. The computer model calculates eigenmobilities, which are the eigenvalues of the matrix tied to the linearized continuity equations, and which are responsible for the presence of system eigenzones (system zones, system peaks). The model also calculates other parameters of the background electrolyte (BGE)-pH, conductivity, buffer capacity, ionic strength, etc., and parameters of the separated analytes--effective mobility, transfer ratio, molar conductivity detection response, and relative velocity slope. This allows the assessment of the indirect detection, conductivity detection and peak broadening (peak distortion) due to electromigration dispersion. The computer model requires the input of the BGE composition, the list of analytes to be separated, and the system instrumental configuration. The output parameters of the model are directly comparable with experiments; the model also simulates electropherograms in a user-friendly way. We demonstrate a successful application of PeakMaster for inspection of BGEs having no stationary injection zone.

Computer Simulation↗

System zones in capillary zone electrophoresis.

When working with capillary zone electrophoresis (CZE), the analyst has to be aware that the separation system is not homogeneous anymore as soon as a sample is brought into the background electrolyte (BGE). Upon injection, the analyte creates a disturbance in the concentration of the BGE, and the system retains a kind of memory for this inhomogeneity, which is propagated with time and leads to so-called system zones (or system eigenzones) migrating in an electric field with a certain eigenmobility. If recordable by the detector, they appear in the electropherogram as system peaks (or system eigenpeaks). However, although their appearance can not be forecasted and explained easily, they are inherent for the separation system. The progress in the theory of electromigration (accompanied by development of computer software) allows to treat the phenomenon of system zones and system peaks now also in very complex BGE systems, consisting of several multivalent weak electrolytes, and at all pH ranges. It also allows to predict the existence of BGEs having no stationary injection zone (or water zone, EO zone, gap, dip). Our paper reviews the theoretical background of the origin of the system zones (system peaks, system eigenpeaks), discusses the validity of the Kohlrausch regulating function, and gives practical hints for preparing BGEs with good separation ability not deteriorated by the occurrence of system peaks and by excessive peak-broadening.

Electrophoresis, Capillary↗

Separation of haloacetic acids in water by capillary zone electrophoresis with direct UV detection and contactless conductivity detection.

The separation of haloacetic acids (HAAs) in water by capillary zone electrophoresis with direct UV and contactless conductivity detection was investigated using phosphate, citrate, and borate buffers, and the experimental data were compared to simulation data predicted by a computational program known as PeakMaster. Good agreement between the experimental data and simulation data predicted by PeakMaster was found. Using the phosphate buffer or the citrate buffer and electrokinetic injection it was possible to quantitate HAAs at 0.1 ppm levels in water.

Acetates↗

Influence of solvent on temperature and thermal peak broadening in capillary zone electrophoresis.

The present paper deals with the role of the solvent on thermal peak broadening. One main solvent property that determines the magnitude of the temperature gradient due to the generation of Joule heat in capillary zone electrophoresis is the thermal conductivity. As organic solvents have lower thermal conductivity than water (methanol and acetonitrile, e.g., nearly by a factor of 3) it can be hypothesized that the temperature gradient inside the capillary is more pronounced in organic solvents compared to an aqueous solution. On the other hand, the temperature dependence of the ion mobility (which is responsible for the velocity profile and thus for thermal peak broadening) is smaller in organic solvents. To get insight into the thermal effect of the solvent, first the temperature of a solution in a cylindrical tube was calculated utilizing the heat balance equation. It was shown that the two theoretical models most common in the literature (based on the analytical solution or on an assumption of the parabolic temperature profile in the tube, respectively) give the same results. The latter model was chosen for the further calculations, adding a quadratic term to express the electric conductivity as a function of the temperature. The temperature at the inner capillary wall and center as function of the capillary dimensions and the electric power was computed for electrolytes with a given conductivity at 25.0 degrees C with water, methanol, and acetonitrile as solvents. Capillary cooling systems used were circulating liquid cooling, enforced air-cooling, and natural convection in still air. The mean temperature (averaged over the cross section) resulting from Joule heating was compared with experimentally determined temperatures established upon application of an electric field; the latter temperature was derived from the measurement of the electric conductance of the background electrolyte solution and its (measured) temperature dependence. All investigations were carried out with solutions of the same initial electric conductivity (about 0.5 S.m(-1) at 25.0 degrees C). Agreement is found for natural convection conditions, and the deviation between theoretical and experimental results for the forced air and circulated liquid cooling systems can be related to the poorly defined thermal conditions of the capillaries in commercial instrumentation (with a part in a thermostated cassette and a part outside). For given conditions the temperature gradients in the organic solvents exceed largely those in water, independent of the type of cooling. As a consequence, the thermal plate height is significantly larger in organic solvents, at least under conditions where the deviation from the Nernst-Einstein limiting case is not too high. However, even for the maximum applicable field strengths the thermal plate height contributions are negligible compared to longitudinal diffusion in all solvents.

Electrophoresis, Capillary↗

High-sensitive capillary zone electrophoresis analysis by electrokinetic injection with transient isotachophoretic preconcentration: electrokinetic supercharging.

The principle of an on-line preconcentration method for capillary zone electrophoresis (CZE) named electrokinetic supercharging (EKS), is described and based on computer simulation the preconcentration behavior of the method is discussed. EKS is an electrokinetic injection method with transient isotachophoretic process, is a powerful preconcentration technique for the analysis of dilute samples. After filling the separation capillary with supporting electrolyte, an appropriate amount of a leading electrolyte was filled and the electrokinetic injection was started. After a while, terminating electrolyte was filled subsequently and migration current was applied. This procedure enabled the introduction of a large amount of sample components from a dilute sample without deteriorating separation. Computer simulation of the electrokinetic injection revealed that EKS was effective for the preconcentration of analytes with wide mobility ranges by proper choice of transient isotachophoresis (ITP) system and electroosmotic flow (EOF) should be suppressed to increase injectable amount of analytes under constant voltage mode. A test mixture of rare-earth chlorides was used to demonstrate the uses of EKS-CZE. When a 100 microL sample was used, the low limit of detectable concentration was 0.3 microg/L (1.8 nM for Er), which was comparable or even better than that of ion chromatography and inductively coupled plasma-atomic emission spectrometry (ICP-AES).

Chlorides↗

Eigenmobilities in background electrolytes for capillary zone electrophoresis: II. Eigenpeaks in univalent weak electrolytes.

We analyze in detail a mathematical model of capillary zone electrophoresis (CZE) based on the conception of eigenmobilities, which are eigenvalues of the matrix tied to the linearized continuity equations. Our model considers CZE systems, where constituents are weak electrolytes and where pH of the background electrolyte may reach the full range from 0 to 14. Both hydrogen and hydroxide ions are taken into account in relations for conductivity and electroneutrality. An electrophoretic system with N constituents has N eigenmobilities. We reveal that two of the eigenmobilities have a special meaning as they exist due to the presence of hydrogen ions and hydroxide ions (in water solutions). These two eigenmobilities are responsible for the existence of two corresponding system zones (system peaks). We show that the stationary zone (injection zone, water zone, gap, peak, dip) is in many common background electrolytes composed of these two eigenzones which overlap, due to their very low electrophoretic mobility, into one zone. Other eigenmobilities give rise to system zones originating due to a possible existence of double (or multiple) coconstituents in the background electrolyte. The last group of eigenmobilities is connected with the movement of eigenzones accompanying analytes and enabling their indirect UV or conductivity detection. The model allows assessing experimentally available quantities such as effective mobility of the analyte, molar conductivity detection response, transfer ratio, and relative velocity slope and gives a picture about migration of analytes, their electromigration dispersion and signals obtained in detectors. It allows computer simulation of electropherograms and enables optimization of background electrolytes.

Electric Conductivity↗

Separation of twenty underivatized essential amino acids by capillary zone electrophoresis with contactless conductivity detection.

Twenty underivatized essential amino acids were separated using capillary zone electrophoresis and consequently detected with contactless conductivity detection (CCD). A simple acidic background electrolyte (BGE) containing 2.3 M acetic acid and 0.1% w/w hydroxyethylcellulose (HEC) allowed the electrophoretic separation and sensitive detection of all 20 essential amino acids in their underivatized cationic form. The addition of HEC to the BGE suppressed both, electroosmotic flow and analyte adsorption on the capillary surface resulting in an excellent migration time reproducibility and a very good analyte peak symmetry. Additionally, the HEC addition significantly reduced the noise and long-term fluctuations of the CCD baseline. The optimized electrophoretic separation method together with the CCD was proved to be a powerful technique for determination of amino acid profiles in various natural samples, like beer, yeast, urine, saliva, and herb extracts.

Amino Acids, Essential↗