A double-blind, randomized, sham-controlled trial of the gastric bubble for obesity.

We investigated the effect of an endoscopically placed gastric balloon, the Garren-Edwards gastric bubble (GEGB), on weight loss in obese patients. Fifty-nine obese patients were entered into a prospective double-blind study and randomized into two groups. In one group (34 patients) the GEGB was inserted, and in the other group (25 patients) a sham insertion was done. All patients participated in a standard weight loss program consisting of dietary therapy, behavior modification, and physical exercise. The bubble was removed endoscopically after 3 months from both groups. Patients were followed for an additional 9 months after bubble removal and weight loss was monitored. Weight loss was the same in both groups at 3 months (18.7 lb vs. 17.2 lb). This was true whether determined by change in pounds, percentage of body weight, or body mass index. We concluded that the GEGB was of no added benefit as compared with sham insertion, when combined with a standard weight loss program. Because of the lack of proven efficacy and the relatively high cost, we recommend that such devices be restricted to controlled studies until significant benefits are proven.

Adult↗

Power Doppler imaging: principles and applications.

Power Doppler Imaging (PDI) is a promising new sonographic technique for evaluating the vascular system. PDI uses special processing to display the amplitude or strength of the Doppler signal, rather than velocity and directional information as in conventional color Doppler. This allows a much greater sensitivity in detecting small vessels and slow-moving blood. Currently PDI is being used only in conjunction with color Doppler, but it has proven valuable in many applications.

Brain Ischemia↗

MR angiography of the renal vessels.

Magnetic resonance angiography (MRA) is a noninvasive imaging procedure that demonstrates flowing blood in the body by distinguishing moving blood from stationary tissues. This article provides a general overview of MRA with emphasis on its use in the diagnosis of renovascular disease. It also discusses the advantages and limitations of renal MRA compared with conventional angiography.

Adult↗

Ultrasound evaluation of TIPS placement.

Sonography is a valuable tool for evaluating shunts used to treat variceal bleeding due to portal hypertension. This article defines the protocol for ultrasound imaging of the transjugular intrahepatic portosystemic shunt (TIPS) and abnormal findings associated with TIPS placement. It also discusses common pitfalls in TIPS imaging, including artifacts, echoes and incomplete visualization.

Blood Flow Velocity↗

Image-guided percutaneous needle biopsy: an overview.

Image-guided percutaneous needle biopsy (IGPNB) is a valuable tool for diagnosis of nonpalpable or deep-seated lesions that cannot be characterized definitively with diagnostic imaging alone. The procedure entails inserting a needle through the skin into an area of suspected pathology under the guidance of various imaging techniques to retrieve a sample of tissue or fluid for analysis. This article discusses the historical development, indications, contraindications, patient preparation, equipment and possible complications of IGPNB, with particular attention to biopsies of the thorax, breast, abdominal organs, head and neck and the musculoskeletal system.

Biopsy, Needle↗

Ultrasound and twin-twin transfusion syndrome.

This article examines twin-twin transfusion syndrome, a condition in which identical twins share a single placenta with abnormal anastomoses. The syndrome causes unequal blood flow between the twins that, if untreated, is likely to result in the death of one or both. Ultrasound is used to diagnose the syndrome and guide treatment, which may consist of aggressive amniocentesis, endoscopic laser surgery or selective feticide.

Amniocentesis↗

Sonographic assessment of hepatic transplants.

Liver transplantation has become a standard treatment for end-stage liver disease, with survival rates for liver transplant patients increasing steadily. Several imaging techniques are used to evaluate patients for possible complications of liver transplantation. This article focuses on the role of ultrasound and color flow and spectral Doppler in evaluating complications such as fluid collections and vascular or biliary obstructions.

Humans↗

Showing acetabular trauma with more clarity, less pain.

Standard radiographic projections may not provide a complete diagnosis of acetabular fractures, which often are the result of an automobile accident or other injury applying severe force to the femur. The Judet oblique projection of the pelvis and a variation described by the authors reduces patient risk and discomfort while demonstrating fractures not clearly seen on routine radiographs.

Acetabulum↗

Technique for diagnosis of scaphoid fractures.

Fracture of the scaphoid bone accounts for 60 percent of all carpal injuries. Early diagnosis of a scaphoid fracture is extremely important. Missing the fracture may lead to disability due to potential avascular necrosis or non-union of the fragments. The presence of a scaphoid fracture may be determined with greater certainty by using a multiple angle scaphoid series detailed by the author.

Adult↗

Apicoaortic valved conduits in a canine model.

Evaluating new developments in surgical methods and materials of aortic bypass prosthetics requires the use of an appropriate animal model, a well established surgical protocol and post surgical aortography. This article describes the surgical technique, post operative care and the angiographic technique used for an apicoaortic conduit placement in a canine model.

Animals↗

Balloon expandable intraluminal vascular stent.

The percutaneous, intraluminal placement of an expandable arterial stent is a new method for reducing stenosis in atherosclerotic arteries. This method, used in conjunction with balloon angioplasty, involves the placement of metallic mesh stent at the sight of the stenosis. Use of this technique has resulted in various improvements over angioplasty alone.

Aged↗

Axillary shoulder with exaggerated rotation: the Hill-Sachs defect.

One of the most common fractures of the humeral head resulting from an anterior dislocation is the Hill-Sachs defect. Other special radiographic positions to demonstrate this injury may prove difficult for the patient to assume and maintain. An axillary shoulder projection with exaggerated external rotation is easy to position and clearly demonstrates the Hill-Sachs defect.

Adult↗

Image enhancement using computed radiography.

Computed radiography (CR) is emerging as a digital imaging modality for use in conventional radiography. An advantage of CR over film-screen systems is the separation of image acquisition, processing and display. Selection of many different image display characteristics are possible. The system is also able to alter or enhance image details after the radiographic examination has been completed.

Humans↗

Computed radiography: photostimulable phosphor image plate technology.

Computed radiography is emerging as a digital imaging modality for use in conventional radiography. It is based on photostimulable phosphor image plate technology. The image plate (IP) is housed in a cassette similar to a standard radiographic cassette. The IP phosphor retains a latent image of the energy pattern to which it was exposed. This latent image is "read" as it is released from the phosphor by laser light exposure. The image is laser printed on 10 in x 14 in film.

Computer Systems↗

Radiography of cutaneous urinary diversions.

Imaging of cutaneous urinary diversions (CUDs) requires the use of special radiographic procedures. This article describes the techniques for radiographic examination of the two major types of CUDs: urinary conduits and continent urinary reservoirs. Diagrams and radiographs depict the structure and function of these urinary diversions. A Quick Procedural Reference guide is included to allow easy introduction of the examination protocols into a radiology department's procedure manual.

Follow-Up Studies↗

Repair of pseudoaneurysms via ultrasound-guided compression.

Pseudoaneurysm formation is one of the potential complications of arterial catheterization. In the past, surgery was the usual method of treatment for pseudoaneurysms. Although surgical repair is still indicated in some cases, a noninvasive procedure called ultrasound-guided compression repair (UGCR) often can be used instead of surgery. During UGCR, an ultrasound transducer is used to apply compression to the pseudoaneurysm, causing a clot to form. This article describes the UGCR procedure and discusses results that clinicians have attained using this method of pseudoaneurysm repair.

Aneurysm, False↗