Search PubMed⌕ Search

Biomedical subjects

B Sinclair

Publications and source records attributed to B Sinclair.

At least 19 recordsLinked to original sources

Is screening for sexually transmitted infections in men who have sex with men who receive non-occupational HIV post-exposure prophylaxis worthwhile?

BACKGROUND/AIMS: Non-occupational HIV post-exposure prophylaxis (NPEP) is routinely prescribed after high risk sexual exposure. This provides an opportunity to screen and treat individuals at risk of concurrent sexually transmitted infections (STI). The aim of this study was to assess the efficacy of an STI screening programme in individuals receiving NPEP. METHODS: STI screens were offered to all individuals receiving NPEP from March 2001 to May 2004. Screen results were compared to type of sexual exposure and baseline patient characteristics. RESULTS: A total of 253 subjects were screened, representing 85% of the target population. All were men who have sex with men (MSM). Common exposure risks were receptive anal intercourse (RAI) in 61% and insertive anal intercourse (IAI) in 33%. 32 (13%) individuals had one or more STI. The most common STIs were rectal infections with Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (NG) in 11 (4.5%) and six (2.5%) individuals, respectively. Subjects with rectal CT were significantly more likely to be co-infected with rectal NG (p<0.001). There was no association between the presence of a rectal STI and age or exposure risk. Only six (19%) individuals with an STI were symptomatic at screening. CONCLUSION: In this cohort of MSM receiving NPEP, high rates of concomitant STIs are observed highlighting the importance of STI screening in this setting.

Adolescent↗

Early dialysis in a neonate with intrauterine lisinopril exposure.

In general, angiotensin converting enzyme (ACE) inhibitors should be discontinued in pregnancy, as they can induce an ACE fetopathy. For the treatment of the latter, early peritoneal dialysis is recommended for in utero exposure to captopril and enalapril, although the outcome is poor. Early peritoneal dialysis has not previously been reported for lisinopril induced multiorgan failure. A case is reported in which treatment was given on postnatal day 3. The patient recovered from oligoanuria to almost normal renal function, and heart, brain, and musculoskeletal injury was reversible. This is despite relatively poor clearance of the drug through peritoneal dialysis. Analysis of the pharmacokinetic data suggests that haemodialysis or haemofiltration would be more efficacious for removal of the drug, and these treatments should be performed if available.

Angiotensin-Converting Enzyme Inhibitors↗

Resection of the lesion in patients with hypothalamic hamartomas and catastrophic epilepsy.

BACKGROUND: Patients with hypothalamic hamartomas (HH) often have severe refractory epilepsy, incapacitating behavioral abnormalities, and cognitive decline. Attempts to control the seizure disorder by resection of apparently epileptogenic mesial temporal or other cortical structures have failed consistently. OBJECTIVE: To report a series of 13 patients in whom the hamartoma itself was resected. METHODS: All patients underwent preoperative evaluation between ages 2 and 33 years and had subtotal or complete resection of the hamartoma. Follow-up ranged from 1 to 5.5 years (mean: 2.8 y). RESULTS: Preoperatively, all patients had variable combinations of gelastic, complex partial, and generalized seizures. Eight had drop attacks. In addition, all had marked behavior abnormalities and cognitive impairment. Postoperatively, two patients are completely seizure-free and 11 are either seizure-free or have achieved a greater than 90% reduction of drop attacks and generalized tonic-clonic seizures. However, minor gelastic, complex partial, and atypical absence seizures have persisted in 11 patients, although at significantly reduced rates. In addition, there has been a dramatic improvement in behavior and cognition. Three patients had an anterior thalamic and one a capsular infarct, which left only minimal long-term deficits. Exact location of the lesion in relation to the interpeduncular fossa and the walls of the third ventricle correlated with extent of excision, seizure control, and complication rate. CONCLUSION: Resection can alleviate both the seizures and the behavioral and cognitive abnormalities of hypothalamic hamartomas, but complications are frequent.

Adolescent↗

Patent foramen ovale and brain microembolization during scoliosis surgery in adolescents.

STUDY DESIGN: A case series is reported. OBJECTIVE: To improve understanding of the potential mechanisms associated with cerebral microemboli during scoliosis surgery in adolescents. SUMMARY OF BACKGROUND DATA: Paradoxical cerebral fat microembolization during scoliosis surgery has been associated with right-to-left shunting through an undetected patent foramen ovale. The prevalence of this cardiac defect in the adult population may be as high as 15% to 25%. Although the clinical relevance of this embolic phenomenon during scoliosis surgery has not been investigated, a few reports have documented its fatal consequences. It has been suspected in some patients with postoperative reduced visual function, particularly after complex instrumented fusions. METHODS: Bilateral transcranial Doppler (2 MHz) was used to monitor cerebral microemboli in the right and left middle cerebral arteries during spinal instrumentation and fusion in four patients. Additionally, transthoracic or transesophageal echocardiography incorporating pulse and color Doppler (3.5-5 MHz) and a contrast test was used in these patients to detect atrial shunts. RESULTS: Intraoperative transcranial Doppler monitoring detected high rates of cerebral microemboli associated with the presence of an atrial communication in two adolescents. In two additional patients with no detected brain microembolization, echocardiographic examination indicated the absence of an atrial shunt. CONCLUSION: The study findings suggest that unrecognized atrial communications in adolescents undergoing scoliosis surgery contribute to higher rates of Doppler-detected cerebral microemboli than those found in adolescents without this congenital defect.

Adolescent↗

Recognition and management of Kawasaki disease.

Kawasaki disease is the leading cause of acquired heart disease in children in the developed world, with coronary artery aneurysms occurring in up to 25% of untreated cases. The mean annual incidence of Kawasaki disease across Canada is about 13 per 100,000 children less than 5 years of age, based on hospital discharge data from 1990 to 1995. The cause remains unknown, and the diagnosis is based on the same clinical criteria used to describe the disease over 30 years ago. However, nonspecific clinical features, evolving presentations and atypical or incomplete presentations make early diagnosis and timely treatment difficult. Delays in diagnosis and treatment, which occur more frequently in older children, are associated with an increased risk of coronary artery aneurysms. Hence, high diagnostic suspicion and prompt referral are required to reduce the rate of cardiac complications.

Adolescent↗

Primary ciliary dyskinesia associated with a novel microtubule defect in a child with Down's syndrome.

We present a child with Down's syndrome, bilateral lower lobe bronchiectasis, sinusitis, and severe ear disease who was found to have a novel ciliary defect, with a frequent, partial absence of the walls of the A subunits of some peripheral doublets. The defect caused the A subunits to be "U-shaped" rather than "O-shaped." A nuclear nasal mucociliary transport study confirmed that this defect was associated with abnormal mucociliary transport. The ciliary defect was not observed in a biopsy performed in a second patient who had Down's syndrome.

Biopsy↗

Prenatal features of ductus arteriosus constriction and restrictive foramen ovale in d-transposition of the great arteries.

BACKGROUND: Although most neonates with d-transposition of the great arteries (TGA) have an uncomplicated preoperative course, some with a restrictive foramen ovale (FO), ductus arteriosus (DA) constriction, or pulmonary hypertension may be severely hypoxemic and even die shortly after birth. Our goal was to determine whether prenatal echocardiography can identify these high-risk fetuses with TGA. METHODS AND RESULTS: We reviewed the prenatal and postnatal echocardiograms and outcomes of 16 fetuses with TGA/intact ventricular septum or small ventricular septal defect. Of the 16 fetuses, 6 prenatally had an abnormal FO (fixed position, flat, and/or redundant septum primum). Five of the 6 had restrictive FO at birth. Five fetuses had DA narrowing at the pulmonary artery end in utero, and 6 had a small DA (diameter z score of <-2.0). Of 4 fetuses with the most diminutive DA, 2 also had an abnormal appearance of the FO, and both died immediately after birth. One other fetus had persistent pulmonary hypertension. Eight fetuses had abnormal Doppler flow pattern in the DA (continuous high-velocity flow, n=1; retrograde diastolic flow, n=7). CONCLUSIONS: Abnormal features of the FO, DA, or both are present in fetuses with TGA at high risk for postnatal hypoxemia. These features may result from the abnormal intrauterine hemodynamics in TGA. A combination of restrictive FO and DA constriction in TGA may be associated with early neonatal death.

Constriction, Pathologic↗

Hemolytic anemia after atrioventricular septal defect repair without synthetic material.

We report a rare case of severe hemolytic anemia following repair of a congenital heart defect without the use of prosthetic material. A review of the literature, diagnosis, and management are described. Although this is an unusual complication following congenital heart surgery, a high index of suspicion must be maintained and a possible mechanical cause should be sought and corrected.

Anemia, Hemolytic↗

Flow convergence flow rates from 3-dimensional reconstruction of color Doppler flow maps for computing transvalvular regurgitant flows without geometric assumptions: An in vitro quantitative flow study.

OBJECTIVE: This study was designed to develop and test a 3-dimensional method for direct measurement of flow convergence (FC) region surface area and for quantitating regurgitant flows with an in vitro flow system. BACKGROUND: Quantitative methods for characterizing regurgitant flow events such as flow convergence with 2-dimensional color flow Doppler imaging systems have yielded variable results and may not be accurate enough to characterize those more complex spatial events. METHOD: Four differently shaped regurgitant orifices were studied: 3 flat orifices (circular, rectangular, triangular) and a nonflat one mimicking mitral valve prolapse (all 4 orifice areas = 0.24 cm(2)) in a pulsatile flow model at 8 to 9 different regurgitant flow rates (10 to 50 mL/beat). An ultrasonic flow probe and meter were connected to the flow model to provide reference flow data. Video composite data from the color Doppler flow images of the FC were reconstructed after computer-controlled 180 degrees rotational acquisition was performed. FC surface area (S cm(2)) was calculated directly without any geometric assumptions by measuring parallel sliced flow convergence arc lengths through the FC volume and multiplying each by the slice thickness (2.5 to 3.2 mm) over 5 to 8 slices and then adding them together. Peak regurgitant flow rate (milliliters per second) was calculated as the product of 3-dimensional determined S (cm(2)) multiplied by the aliasing velocity (centimeters per second) used for color Doppler imaging. RESULTS: For all of the 4 shaped orifices, there was an excellent relationship between actual peak flow rates and 3-dimensional FC-calculated flow rates with the direct measurement of the surface area of FC (r = 0.99, mean difference = -7.2 to -0.81 mL/s, % difference = -5% to 0%), whereas a hemielliptic method implemented with 3 axial measurements of the flow convergence zone from 2-dimensional planes underestimated actual flow rate by mean difference = -39.8 to -18.2 mL/s, % difference = -32% to -17% for any given orifice. CONCLUSIONS: Three-dimensional reconstruction of flow based on 2-dimensional color Doppler may add quantitative spatial information, especially for complex flow events. Direct measurement of 3-dimensional flow convergence surface areas may improve accuracy for estimation of the severity of valvular regurgitation.

Blood Flow Velocity↗

Cerebral blood flow velocities monitored by transcranial Doppler during cardiac catheterizations in children.

Transcranial Doppler (TCD) was used to evaluate brain circulation during cardiac catheterizations in 32 children requiring pulmonary (n=10) or aortic balloon dilatations (n=2), ductus arteriosus coil insertions (n=5), or angiography (n=15). Cerebral blood flow velocity (CBFV) in the middle cerebral artery was measured before (baseline), during, and after each procedure (mean+/-95%ci). High-intensity transient signals (HITS) were also detected during these maneuvers. Balloon angioplasty decreased CBFV by 63+/-11% from baseline (P < 0.01). Shorter durations of the inflation cycle resulted in earlier CBFV recovery (r=0.78). During angiography, CBFV increased by 11+/-4% (P < 0.01) in all except one case that showed retrograde diastolic flow. Mean total HITS count was 44 (95%ci.limits: 27,74). These signals were more frequently found in septal defects or systemic arterial manipulations. Pediatric cardiac catheterization may impose transient fluctuations in brain perfusion as indicated by TCD, but their clinical implications are uncertain. CBFV changes during balloon angioplasty emphasize the importance of rapid inflation/deflation cycles. TCD can monitor such changes and evaluate preventive measures.

Adolescent↗

Temporal variability of vena contracta and jet areas with color Doppler in aortic regurgitation: a chronic animal model study.

OBJECTIVE: The purpose of our study was to determine the temporal variability of regurgitant color Doppler jet areas and the width of the color Doppler imaged vena contracta for evaluating the severity of aortic regurgitation. METHODS: Twenty-nine hemodynamically different states were obtained pharmacologically in 8 sheep 20 weeks after surgery to produce aortic regurgitation. Aortic regurgitation was quantified by peak and mean regurgitant flow rates, regurgitant stroke volumes, and regurgitant fractions determined using pulmonary and aortic electromagnetic flow probes and meters balanced against each other. The regurgitant jet areas and the widths of color Doppler imaged vena contracta were measured at 4 different times during diastole to determine the temporal variability of this parameter. RESULTS: When measured at 4 different temporal points in diastole, a significant change was observed in the size of the color Doppler imaged regurgitant jet (percent of difference: from 31.1% to 904%; 233% +/- 245%). Simple linear regression analysis between each color jet area at 4 different periods in diastole and flow meter-based severity of the aortic regurgitation showed only weak correlation (0.23 < r < 0.49). In contrast, for most conditions only a slight change was observed in the width of the color Doppler imaged vena contracta during the diastolic regurgitant period (percent of difference, vena contracta: from 2.4% to 12.9%, 5.8% +/- 3.2%). In addition, for each period the width of the color Doppler imaged vena contracta at the 4 different time periods in diastole correlated quite strongly with volumetric measures of the severity of aortic regurgitation (0.81 < r < 0.90) and with the instantaneous flow rate for the corresponding period (0.85 < r < 0.87). CONCLUSIONS: Color Doppler imaged vena contracta may provide a simple, practical, and accurate method for quantifying aortic regurgitation, even when using a single frame color Doppler flow mapping image.

Animals↗

Effective regurgitant orifice area by the color Doppler flow convergence method for evaluating the severity of chronic aortic regurgitation. An animal study.

BACKGROUND: The aim of the present study was to evaluate dynamic changes in aortic regurgitant (AR) orifice area with the use of calibrated electromagnetic (EM) flowmeters and to validate a color Doppler flow convergence (FC) method for evaluating effective AR orifice area and regurgitant volume. METHODS AND RESULTS: In 6 sheep, 8 to 20 weeks after surgically induced AR, 22 hemodynamically different states were studied. Instantaneous regurgitant flow rates were obtained by aortic and pulmonary EM flowmeters balanced against each other. Instantaneous AR orifice areas were determined by dividing these actual AR flow rates by the corresponding continuous wave velocities (over 25 to 40 points during each diastole) matched for each steady state. Echo studies were performed to obtain maximal aliasing distances of the FC in a low range (0.20 to 0.32 m/s) and a high range (0.70 to 0.89 m/s) of aliasing velocities; the corresponding maximal AR flow rates were calculated using the hemispheric flow convergence assumption for the FC isovelocity surface. AR orifice areas were derived by dividing the maximal flow rates by the maximal continuous wave Doppler velocities. AR orifice sizes obtained with the use of EM flowmeters showed little change during diastole. Maximal and time-averaged AR orifice areas during diastole obtained by EM flowmeters ranged from 0.06 to 0.44 cm2 (mean, 0.24 +/- 0.11 cm2) and from 0.05 to 0.43 cm2 (mean, 0.21 +/- 0.06 cm2), respectively. Maximal AR orifice areas by FC using low aliasing velocities overestimated reference EM orifice areas; however, at high AV, FC predicted the reference areas more reliably (0.25 +/- 0.16 cm2, r = .82, difference = 0.04 +/- 0.07 cm2). The product of the maximal orifice area obtained by the FC method using high AV and the velocity time integral of the regurgitant orifice velocity showed good agreement with regurgitant volumes per beat (r = .81, difference = 0.9 +/- 7.9 mL/beat). CONCLUSIONS: This study, using strictly quantified AR volume, demonstrated little change in AR orifice size during diastole. When high aliasing velocities are chosen, the FC method can be useful for determining effective AR orifice size and regurgitant volume.

Animals↗

Evaluation of aortic regurgitation with digitally determined color Doppler-imaged flow convergence acceleration: a quantitative study in sheep.

OBJECTIVES: The aim of the present study was to validate a digital color Doppler-based centerline velocity/distance acceleration profile method for evaluating the severity of aortic regurgitation. BACKGROUND: Clinical and in vivo experimental applications of the flow convergence axial centerline velocity/distance profile method have recently been used to estimate regurgitant flow rates and regurgitant volumes in the presence of mitral regurgitation. METHODS: In six sheep, a total of 19 hemodynamic states were obtained pharmacologically 14 weeks after the original operation in which a portion of the aortic noncoronary (n = 3) or right coronary (n = 3) leaflet was excised to produce aortic regurgitation. Echocardiographic studies were performed to obtain complete proximal axial flow acceleration velocity/distance profiles during the time of peak regurgitant flow (usually early in diastole) for each hemodynamic state. For each steady state, the severity of aortic regurgitation was assessed by measurement of the magnitude of the regurgitant flow volume/beat, regurgitant fraction and instantaneous regurgitant flow rates determined by using both aortic and pulmonary artery electromagnetic flow probes. RESULTS: Grade I regurgitation (regurgitant volume/beat < 15 ml, six conditions), grade II regurgitation (regurgitant volume/beat between 16 ml and 30 ml, five conditions) and grade III-IV regurgitation (regurgitant volume/beat > 30 ml, eight conditions) were clearly separated by using the color Doppler centerline velocity/distance profile domain technique. Additionally, an equation for correlating "a" (the coefficient from the multiplicative curve fit for the velocity/distance relation) with the peak regurgitant flow rates (Q [liters/min]) was derived showing a high correlation between calculated peak flow rates by the color Doppler method and the actual peak flow rates (Q = 13a + 1.0, r = 0.95, p < 0.0001, SEE = 0.76 liters/min). CONCLUSIONS: This study, using quantified aortic regurgitation, demonstrates that the flow convergence axial centerline velocity/distance acceleration profile method can be used to evaluate the severity of aortic regurgitation.

Animals↗

Three-dimensional reconstruction of color Doppler flow convergence regions and regurgitant jets: an in vitro quantitative study.

OBJECTIVES: This study sought to investigate the applicability of a current implementation of a three-dimensional echocardiographic reconstruction method for color Doppler flow convergence and regurgitant jet imaging. BACKGROUND: Evaluation of regurgitant flow events, such as flow convergences or regurgitant jets, using two-dimensional imaging ultrasound color flow Doppler systems may not be robust enough to characterize these spatially complex events. METHODS: We studied two in vitro models using steady flow to optimize results. In the first constant-flow model, two different orifices were each mounted to produce flow convergences and free jets--a circular orifice and a rectangular orifice with orifice area of 0.24 cm(2). In another flow model, steady flows through a circular orifice were directed toward a curved surrounding wall to produce wall adherent jets. Video composite data of color Doppler flow images from both free jet and wall jet models were reconstructed and analyzed after computer-controlled 180 degrees rotational acquisition using a TomTec computer. RESULTS: For the free jet model there was an excellent relation between actual flow rates and three-dimensional regurgitant jet volumes for both circular and rectangular orifices (r = 0.99 and r = 0.98, respectively). However, the rectangular orifice produced larger jet volumes than the circular orifice, even at the same flow rates (p < 0.0001). Calculated flow rates by the hemispheric model using one axial measurement of the flow convergence isovelocity surface from two-dimensional color flow images underestimated actual flow rate by 35% for the circular orifice and by 44% for the rectangular orifice, whereas a hemielliptic method implemented using three axial measurements of the flow convergence zone derived using three-dimensional reconstruction correlated well with and underestimated actual flow rate to a lesser degree (22% for the circular orifice, 32% for the rectangular orifice). In the wall jet model, the jets were flattened against and spread along the wall and had reduced regurgitant jet volumes compared with free jets (p < 0.01). CONCLUSIONS: Three-dimensional reconstruction of flow imaged by color Doppler may add quantitative spatial information to aid computation methods that have been used for evaluating valvular regurgitation, especially where they related to complex geometric flow events.

Echocardiography, Doppler, Color↗

Evaluation of eccentric aortic regurgitation by color Doppler jet and color Doppler-imaged vena contracta measurements: an animal study of quantified aortic regurgitation.

To evaluate the utility of measurements of the color Doppler jet area, jet length, and width of the color Doppler-imaged vena contracta (the smallest flow diameter in any part of the flow acceleration field) as methods for quantifying aortic regurgitation (AR), eight sheep with surgically induced AR were studied. AR was quantified as peak and mean regurgitant flow rates, regurgitant stroke volumes, and regurgitant fractions as determined with pulmonary and aortic electromagnetic flow probes and flowmeters balanced against each other. Simple linear regression analysis between the maximal color jet areas, jet length, and flowmeter data showed only moderately good correlation (jet area: 0.42 < or = r < or = 0.57, SEE = 2.85 cm2; jet length: 0.42 < or = r < or = 0.59, SEE = 1.23 cm). In contrast, the width of color Doppler-imaged vena contracta was a better indicator of the severity of AR on the basis of the electromagnetic flowmeter methods (0.73 < or = r < or = 0.90, SEE = 0.15 cm). Therefore the color Doppler jet length and jet area methods have limited use for determining AR, whereas the width of the color Doppler-imaged vena contracta can be used for quantifying the severity of AR.

Animals↗

Patterns in the drug treatment of hypertension in Auckland, 1982-7.

This paper examines the pattern of drug treatment of hypertension in Auckland in the period 1982 to 1987 using data from a representative sample of the adult population interviewed in 1982 and followed up in 1987. In 1982 the age standardised prevalence of antihypertensive treatment for people aged 40-64 years was 12.2% (95%Cl 10.4, 14.0) and in 1987 it was 10.2% (95%Cl 8.5, 11.8). Over the five year period of this study, 6% of the sample untreated in 1982 began treatment with antihypertensive medication, while 24% of those on drugs in 1982 had stopped treatment by 1987. The most common medications used in both 1982 and 1987 for hypertension were diuretics and beta blockers. Over the five year period diuretic use fell and beta blocker use remained constant. In 1982 3% of hypertensives were taking a calcium antagonist but in 1987 13% were on these drugs and a further 13% were using ACE inhibitors. This study suggests that the prevalence of drug treatment for hypertension has plateaued in New Zealand; coincidentally there is a trend towards use of more expensive drugs.

Adult↗