Search PubMed⌕ Search

Biomedical subjects

B M Wright

Publications and source records attributed to B M Wright.

At least 37 records · Page 2Linked to original sources

Syringe pumps.

Explore the source record for details and available documents.

Ambulatory Care↗

Parental response to competence and trauma in infants with reproductive casualty.

This study of 31 infants in neonatal intensive care and their parents examined the relationship involving infant characteristics (medical and behavioral), parent characteristics (personality and stuational variables), and the development of parental attachment. As expected, infants who were more visually competent had mothers who were more attentive. Contrary to expectation, greater prematurity was related to greater parental involvement. There were important differences in maternal and paternal responses, with mothers using more denial to cope with the medical crisis. Parents who relied heavily on denial were found to have impaired attachment.

Adult↗

Salivary ethanol.

Explore the source record for details and available documents.

Breath Tests↗

Distress in clients and significant others: the question of causality.

Previous research documenting the association between the level of client disturbance and distress in a significant other has generated two competing causal models. Investigators measuring the level of family burden have suggested that it is the discharged patient who causes distress in the family. Investigators of family factors in patient relapse have suggested that it is the family who disturbs the patient. In this study the relative strengths of these two causal models are compared in a sample of outpatients over a six-month period of time. The data indicate that the significant other is causally predominant in the exacerbation of client disturbance.

Adult↗

Now let me see.

Explore the source record for details and available documents.

Developing Countries↗

A miniature Wright peak-flow meter.

A new miniature Wright peak-flow meter has been designed and produced. The meter is tubular with a spring-loaded piston and a longitudinal slot through which air escapes. Its dynamic characteristics have been carefully designed to make it respond only to peak flow and not to rate of rise. Performance tests on early instruments showed fairly close correlation with the Wright peak-flow meter but with a constant error of + 38 1/min. On later models the correlation was increased to 0.990 and the error reduced to + 3%. The mini-meter correlates as well with the standard instrument as two standard instruments correlate with each other and should prove useful clinically.

Forced Expiratory Flow Rates↗