Search PubMed⌕ Search

PubMed · 728756

A miniature Wright peak-flow meter.

Abstract

A new miniature Wright peak-flow meter has been designed and produced. The meter is tubular with a spring-loaded piston and a longitudinal slot through which air escapes. Its dynamic characteristics have been carefully designed to make it respond only to peak flow and not to rate of rise. Performance tests on early instruments showed fairly close correlation with the Wright peak-flow meter but with a constant error of + 38 1/min. On later models the correlation was increased to 0.990 and the error reduced to + 3%. The mini-meter correlates as well with the standard instrument as two standard instruments correlate with each other and should prove useful clinically.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

B M Wright. 1978-12-09. A miniature Wright peak-flow meter.. https://doi.org/10.1136/bmj.2.6152.1627. https://searchpubmed.org/record/pubmed%3A728756/a-miniature-wright-peak-flow-meter

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Search PubMed by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related citations

Expiratory flow limitation detected by forced oscillation and negative expiratory pressure.

The within-breath change in reactance (Delta(rs)) measured by forced oscillation technique (FOT) at 5 Hz reliably detects expiratory flow limitation in chronic obstructive pulmonary disease (COPD). The present study compared this approach to the standard negative expiratory pressure (NEP) method. In total, 21 COPD patients were studied by applying both techniques to the same breath and in 15 patients the measurements were repeated after bronchodilator. For each patient and condition five NEP tests were performed and independently scored by three operators unaware of the FOT results. In 180 tests, FOT classified 53.3% as flow limited. On average, the operators scored 27.6% of tests flow limited and 47.6% non-flow limited, but could not score 24.8%. The methods disagreed in 7.9% of cases; in 78% of these the NEP scores differed between operators. Bronchodilation reduced NEP and DeltaX(rs) scores, with only the latter achieving significance. Averaging the operators' NEP scores, a threshold between 24.6-30.8% of tidal volume being flow limited by NEP produced 94% agreement between methods. In conclusion, when negative expiratory pressure and forced oscillation technique were both available they showed good agreement. As forced oscillation technique is automatic and can measure multiple breaths over long periods, it is suitable for monitoring expiratory flow limitation continuously and identifying patients' breathing close to the onset of expiratory flow limitation, where intermittent sampling may be unrepresentative.

Forced Expiratory Flow Rates↗