Search PubMed⌕ Search

Biomedical subjects

B I Choi

Publications and source records attributed to B I Choi.

At least 37 records · Page 2Linked to original sources

Measurement of radiation absorbed dose in endovascular Ho-166 brachytherapy using a balloon angio-catheter.

The purpose of this study was to estimate the absorbed dose distribution of Ho-166 endovascular beta irradiation using an angio-catheter. The liquid form of Ho-166 was produced at the Korea Atomic Energy Research Institute (KAERI) by an (n,gamma) reaction. Ho-166 has a half-life of 26.8 h and emits a high-energy beta particle with a maximum energy of 1.85 MeV. GafChromic film was used for the estimation of the absorbed dose of beta particles. A Co-60 teletherapy source and a 6 MV photon beam from a linear accelerator were used to generate dose-optical density calibration curves. The exposed films were read using a videodensitometer. With a modified micrometer, the film was positioned accurately on the surface of the balloon in water. The balloon was filled with Ho-166 solution to a pressure of 4 atm. Several film exposures were made with varying irradiation times and activities. The radiation absorbed dose rates were 1.02, 0.51 and 0.35 Gy x min(-1) x GBq(-1) x ml(-1) at the balloon surface, 0.5 and 1 mm from the balloon surface, respectively. The absorbed dose distribution revealed that Ho-166 is a good source for endovascular irradiation as the beta range is very short, avoiding unnecessary irradiation of normal tissue. A clinically applicable irradiation and duration of exposure were achievable utilizing our system.

Angioplasty, Balloon, Coronary↗

Vascularity of hepatocellular carcinoma: assessment with contrast-enhanced second-harmonic versus conventional power Doppler US.

PURPOSE: To compare contrast material-enhanced harmonic power Doppler ultrasonography (US) with conventional power Doppler US in depicting the vascularity of hepatocellular carcinoma (HCC). MATERIALS AND METHODS: Twenty patients with nodular HCCs (2.6-13.2 cm in diameter; mean diameter, 4.8 cm) were prospectively examined with both conventional and harmonic power Doppler US. US was performed with a 2-4-MHz curved linear-array transducer according to a standard examination protocol (1,000-Hz pulse repetition frequency, medium wall filter, and power gain of 55%-84% for conventional power Doppler US; 700-Hz pulse repetition frequency, low wall filter, and power gain of 95%-98% for harmonic power Doppler US). Serial, dynamic scans were obtained before intravenous injection of the contrast agent (SH U 508A) and at 30, 60, 90, 120, 180, 240, and 300 seconds after injection with both techniques. RESULTS: The number of intratumoral power Doppler US signals was similar with both techniques at 30-90 seconds after contrast agent injection; however, after 90 seconds, conventional power Doppler US depicted significantly more signals than did harmonic power Doppler US. Harmonic power Doppler US was superior to conventional power Doppler US in terms of power Doppler artifacts such as "blooming" or motion-related artifacts. CONCLUSION: Although the effective enhancement duration is relatively short compared with that for conventional power Doppler US, contrast-enhanced harmonic power Doppler US can be effective in evaluating the vascularity of HCCs because of the advantage of fewer power Doppler artifacts.

Aged↗

Hepatic tumors: contrast agent-enhancement patterns with pulse-inversion harmonic US.

PURPOSE: To evaluate contrast agent-enhancement patterns in hepatic hemangiomas, hepatic metastases, and hepatocellular carcinomas (HCCs) at pulse-inversion harmonic ultrasonography (US) with a microbubble contrast agent. MATERIALS AND METHODS: Twenty hepatic hemangiomas in 20 patients and 41 malignant hepatic tumors in 23 patients (33 metastases and eight HCCs) were evaluated with pulse-inversion harmonic US. US images were obtained before injection and every 10-15 seconds after injection of a 4-g bolus (300 mg/mL) of SH U 508A (a microbubble contrast agent) for 5 minutes. The contrast-enhancement patterns of 61 hepatic lesions were assessed. RESULTS: Of 20 hemangiomas, 19 revealed peripheral enhancement, which was globular in 14 (70%) and rimlike in five (25%), with centripetal fill-in; the remaining one (5%) showed homogeneous enhancement. In 33 metastases, the enhancement was rimlike in 16 (48%), homogeneous in seven (21%), and stippled in two (6%); in the remaining eight metastases (24%), no enhancement was seen. Of eight HCCs, four (50%) showed homogeneous enhancement and the remaining four (50%) showed heterogeneous enhancement. Centripetal fill-in of lesions with intratumoral enhancement was not seen in any malignancy. CONCLUSION: Pulse-inversion harmonic US with a microbubble contrast agent is potentially useful for the specific diagnosis of hemangiomas that demonstrate characteristic enhancement features.

Adult↗

Gadolinium mesoporphyrin as an MR imaging contrast agent in the evaluation of tumors: an experimental model of VX2 carcinoma in rabbits.

OBJECTIVE: We determined the enhancement features of experimentally induced malignant tumors on MR imaging with the use of gadolinium mesoporphyrin, a recently developed MR contrast agent that may be necrosis-specific. MATERIALS AND METHODS: VX2 carcinoma was inoculated into 24 rabbit thighs. T1-weighted contrast-enhanced MR imaging with IV gadopentetate dimeglumine (2-min delay) and gadolinium mesoporphyrin (20-hr delay) was performed 3-4 days (n = 6), 6-7 days (n = 6), 10-11 days (n = 5), and 13-14 days (n = 7) after the implantation of VX2 carcinoma. All tumors were sectioned along the same plane of MR images, and a detailed MR imaging-histopathologic correlation was performed. RESULTS: Pathologically, areas enhanced with gadolinium mesoporphyrin included necrotic tissue, viable tumor, inflammatory granulation tissue, hemorrhage, and fibrosis. On gadopentetate dimeglumine-enhanced MR images, unenhanced areas of the tumor corresponded with intratumoral necrosis and hemorrhage. CONCLUSION: Gadolinium mesoporphyrin enhances tumor necrosis on delayed phase MR imaging; however, it is impossible to specifically depict necrosis with gadolinium mesoporphyrin because it also enhances other parts of lesions, including viable tumor.

Animals↗

CT features of intraductal intrahepatic cholangiocarcinoma.

OBJECTIVE: The objective of this report was to describe the CT features of intraductal intrahepatic cholangiocarcinoma. CONCLUSION: Segmental or lobar dilatation of the intrahepatic bile ducts associated with or without intraductal polypoid mass, amorphous structures, or both with slight hyperattenuation are common CT findings of intraductal intrahepatic cholangiocarcinoma. The size of the intraductal mass determines the visibility on CT.

Adult↗

The effect of external electron beam on neointima in rat carotid artery injury model.

PURPOSE: Endovascular irradiation with either a gamma or a beta source has shown to reduce neointimal proliferation. However, the effect of external-beam radiation on neointimal hyperplasia is controversial. The objective of this study was to determine the effect of external-beam irradiation with different doses on neointimal hyperplasia in the rat carotid artery injury model. METHODS AND MATERIALS: Twenty-seven Sprague-Dawley rats underwent endothelial denudation injury by 2F Fogarty balloons on carotid artery. Immediately after the injury, rats were irradiated externally using 6-MeV electrons. Rats were grouped according to the radiation doses, 0 Gy as controls (n = 5), 5 Gy (n = 5), 10 Gy (n = 5), 15 Gy (n = 6), and 20 Gy (n = 6). Then, rats were sacrificed after 2 weeks and the carotid arteries were perfusion-fixed in paraformaldehyde. External elastic lamina (EEL) area, lumen area, maximal intimal thickness (MIT), and intimal area (IA) of the injured segments were measured on the basis of histomorphometry. RESULTS: In EEL and lumen area, there was no statistically significant difference between the irradiated groups and the controls. In MIT and IA, low-dose radiation (5 Gy and 10 Gy) did not induce any significant reduction. High-dose radiation (15 Gy and 20 Gy), however, reduced MIT and IA significantly. CONCLUSION: External electron beam reduced the intimal area, and the inhibition of neointimal proliferation was dependent upon radiation doses. This study suggests that the minimal effective dose for the inhibition of neointimal hyperplasia following denudation injury in the rat carotid model is between 10 Gy and 15 Gy.

Animals↗

Signal from hepatic hemangiomas on power Doppler US: real or artefactual?

To describe imaging findings of hepatic hemangiomas on power Doppler (PD) ultrasound (US) with revised Doppler parameters for preventing PD artefacts from stationary hyperechoic tissue, we prospectively evaluated 48 hemangiomas by PD US with predetermined PD settings to prevent artefactual signals from stationary hyperechoic tissue (pulse repetition frequency of 1000 Hz, medium wall filter, and PD gain of 60-85%). Intratumoral PD signals were not seen in 32 lesions (67%). Minimal (n = 15) or moderate (n = 1) intratumoral PD signals were seen in 16 lesions (33%) and were distributed in the peripheral portion only in 12 lesions (75%) and in the peripheral and central portion in 4 lesions (25%). Due to the lack of sensitivity of PD to detect slow flow in hemangiomas, PD US should no longer be used for the evaluation of echogenic liver masses caused by hemangiomas from other hypovascular malignant lesions of the liver.

Adult↗

Experimental hepatobiliary fascioliasis in rabbits: a radiology-pathology correlation.

RATIONALE AND OBJECTIVES: The authors sought to correlate the radiologic findings of hepatobiliary fascioliasis with pathologic features. METHODS: Serial ultrasound, computed tomography (CT), and magnetic resonance findings in seven rabbits with experimentally induced fascioliasis were obtained every other week. Direct cholangiogram was also obtained after the rabbits were killed. Radiology-pathology correlation was done in specimens. RESULTS: In the parenchymal phase (an acute phase of parenchymal invasion of a larva), CT showed subcapsular clustered areas of low attenuation. Magnetic resonance appearance was similar in shape but better than CT in characterizing the hemorrhagic nature of the lesion. Ultrasound findings were nonspecific in this phase. In the ductal phase (a stationary phase after residing in the bile duct), CT showed dilatation of central ducts with symmetric periportal hypoattenuation (periportal tracking). Magnetic resonance could not depict mild ductal dilatation. Ultrasound was most valuable in demonstrating the moving worm within the dilated duct. Pathologically, the hepatic parenchymal lesions consisted of a cluster of eosinophilic granulomas with hemorrhagic change (migratory tract of the flukes). Ductal changes were observed predominantly in the central bile ducts. Periportal lymphangiectasia was also noted. CONCLUSIONS: Computed tomography or magnetic resonance can demonstrate the characteristic evolutionary pattern of fascioliasis that reflects the unique life cycle of Fasciola hepatica. The role of ultrasound, although limited in the parenchymal phase, was most useful in the ductal phase in that it demonstrated the moving worms themselves.

Animals↗

Influence of instrument settings on flow signal and background noise in power Doppler US. An experimental study using a flow phantom with hyperechoic background.

OBJECTIVE: To determine the influence of various power Doppler instrument settings on intensities of flow signal and background noise in flow with a tissue-equivalent phantom. METHODS: Power Doppler images were obtained with changing wall filter level (low, medium, high, and maximum), pulse repetition frequency (PRF; 500, 700, 1000, 1500, 3000, and 6000 Hz), and Doppler gain (60%, 70%, 80%, 90%, and 100%) at different flow velocities (13.3, 26.5, and 49.8 cm/sec). To make a quantitative comparison of different settings, the authors measured the intensities of flow signal and background noise in obtained power Doppler images using the scanner and a computer program, calculated signal-to-noise difference (SND; intensity of flow signal--intensity of background noise), and evaluated the relation between SND and power Doppler settings. RESULTS: The intensities of flow signal and background noise were proportional to flow velocity and power Doppler gain but were inversely proportional to PRF and wall filter level. At constant wall filter level (medium), changes of PRF and Doppler gain to the same directions resulted in a high SND. At constant PRF (1000 Hz), changes of wall filter and Doppler gain to the same directions also resulted in a high SND. However, at constant Doppler gain (80%), a high SND was obtained with changing wall filter level and PRF to the opposite directions. CONCLUSIONS: Three Doppler instrument settings--wall filter level, pulse repetition frequency, and Doppler gain--have reciprocal influences on SND.

Blood Flow Velocity↗

Low-grade gastric mucosa-associated lymphoid tissue lymphoma: correlation of radiographic and pathologic findings.

PURPOSE: To describe upper gastrointestinal (Gl) examination findings of low-grade gastric mucosa-associated lymphoid tissue (MALT) lymphoma and to correlate them with pathologic examination findings. MATERIALS AND METHODS: A retrospective review of upper Gl examinations was performed in 25 patients with proved low-grade gastric MALT lymphomas. Upper Gl examinations were reviewed for common findings and most probable diagnosis, and these findings were correlated with pathologic findings in resected specimens in 15 patients. RESULTS: The common findings at upper Gl examination included mucosal nodularity (n = 13), ulcer (n = 12), rugal thickening (n = 6), mass (n = 4), and enlarged areae gastricae (n = 2). The most probable diagnoses were early gastric carcinoma (n = 7), advanced gastric carcinoma (n = 6), gastritis (n = 9), and lymphoma (n = 3). Of 17 lesions found on resected specimens, six ulcers and two masses were not depicted at barium study. Disorganized convergent rugae projecting to multiple points and vague ulcer margins were present in four and seven lesions, respectively. Multiple ulcers were seen in two patients. CONCLUSION: Although the common radiographic and pathologic findings observed in low-grade gastric MALT lymphomas were similar to those of gastric carcinomas or gastritis, disorganized convergent rugae, vague ulcer margins, and multiplicity of lesions may be helpful in differentiating them from gastric carcinomas or gastritis.

Adult↗

CT features of intraperitoneal manifestations of parasitic infestation.

OBJECTIVE: The purpose of this study was to evaluate the CT features of intraperitoneal manifestations with parasitic infestation in nine patients. CONCLUSION: The CT features of intraperitoneal manifestations of parasitic infestation were single or multiple multiseptated cystic masses in the peritoneal cavity, hazy omental infiltration, or both. Recognizing these features is important to establish an early diagnosis that leads to rapid treatment and helps avoid unnecessary surgery.

Female↗

Hepatic changes in benign obstruction of the hepatic inferior vena cava: CT findings.

OBJECTIVE: The objective of this study was to describe CT findings of changes in the liver associated with benign obstruction of the hepatic inferior vena cava (IVC). MATERIALS AND METHODS: For a 10-year period, 35 patients with benign obstruction of the hepatic IVC underwent contrast-enhanced CT of the abdomen. These patients were included in this retrospective study. CT scans were analyzed for morphologic changes and abnormal enhancement of the liver, changes in intrahepatic vessels, and additional findings that might be related to obstruction of the IVC. RESULTS: Morphologic changes of the liver included hypertrophy of the caudate lobe (91%) and the left lobe (57%), atrophy of the right lobe (49%), and a nodular surface (74%). The most common pattern of attenuation change was areas of linear, irregular, or wedge-shaped hypoattenuation predominantly located in the peripheral portion of the liver (63%). Diffuse hypoattenuation was seen in six patients (19%) and was frequently found in areas in which hepatic veins filled with hypoattenuated thrombosis (67%). On CT, segmental IVC obstruction (80%) was seen as an obliterated segment of the hepatic IVC. However, membranous IVC obstruction (20%) was not seen on CT. The IVC below the level of obstruction was often revealed as rounded (89%) and occasionally contained thrombus (37%) or calcification (26%). CONCLUSION: CT shows a broad spectrum of morphologic and attenuation changes of the liver and of the hepatic vessels in benign obstruction of the hepatic IVC.

Adult↗

Limitations of characterization of hepatic hemangiomas using a sonographic contrast agent (Levovist) and power Doppler ultrasonography.

Power Doppler ultrasonography using a sonographic contrast agent (Levovist) was evaluated in 20 patients with hepatic hemangiomas with a 2-4 MHz convex transducer according to a standardized examination protocol (pulse repetition frequency, 1000 Hz; medium wall filter; power Doppler gain, 50 to 85%). Enhancement patterns were assessed and were compared with those on dynamic magnetic resonance imaging (n = 11) or computed tomography (n = 9). The most common enhancement pattern was dotlike or linear enhancement located predominantly at the periphery of the tumor (15 cases, 75%). Diffuse homogeneous enhancement was seen in one case (5%). No definite contrast enhancement was evident in four cases (20%). The enhanced area on ultrasonograms was smaller than that on dynamic MR images or CT scans in 18 cases (90%). A transient centripetal fill-in pattern was identified in six cases (30%). Persistent enhancement until 300 s was not seen in any case. Therefore, specific diagnosis of hemangioma with power Doppler ultrasonography and contrast agent may not be possible.

Adult↗

Differentiation of small hyperechoic renal cell carcinoma from angiomyolipoma: computer-aided tissue echo quantification.

To assess the value of computer-aided tissue echo quantification in differentiating small hyperechoic renal cell carcinomas from angiomyolipomas, we studied ultrasonographic images of 15 renal cell carcinomas and 20 angiomyolipomas. After digitizing the images, we measured the absolute gray scale values of the renal cortex, central echo complex, and mass. The relative gray scale value (%) of the mass was calculated by setting the gray scale value of the cortex as 0% and the central echo complex as 100%. The relative gray scale value of renal cell carcinomas was in the range of 12 to 73% (mean, 28%), whereas that of angiomyolipomas was 30 to 204% (mean, 130%). The differentiation between small hyperechoic renal cell carcinomas and angiomyolipomas can be facilitated by computer-aided tissue echo quantification.

Adult↗