CT colonography in a Korean population with a high residue diet: comparison between wet and dry preparations.

AIM: To compare wet and dry preparation methods for computed tomography colonography (CTC) in terms of preparation quality, interpretation time, and diagnostic performance for polyp detection in a population with a high residue diet. MATERIALS AND METHODS: Eighty-six patients were divided into two groups. Group 1 (n=24) received a wet preparation of 4l polyethylene glycol (PEG) solution, and group 2 (n=62) received a dry preparation of phosphor-soda. Abnormal findings, including polyps, and the time required to interpret the CTC images in both groups were documented by a radiologist. CTC findings were compared to those of colonoscopy as a reference standard. Two radiologists evaluated the quality of CTC with regard to residual fluid, faeces, and colonic distension using a four-point scale in consensus. Statistical differences for residual fluid, faeces, distensibility on CTC, and interpretation time between the two groups were analysed. The diagnostic performance of CTC in both groups was also compared. RESULTS: One-hundred and ninety polyps in 70 patients were identified using colonoscopy. Regarding the quality of images produced the wet preparation was significantly better than the dry preparation (p<0.05). The average interpretation time was significantly shorter for the wet group (11.7 min) than the dry group (16.4 min) (p<0.05). For per-patient analysis, the positive predictive value (PPV) was significantly better for the wet (100%) than the dry group (79.6%; p=0.025). Sensitivities and PPV for >or=10 mm polyps were comparable between two groups (p>0.05). CONCLUSION: In a population with a high-residue diet, CTC with wet preparation can be interpreted in a time-efficient manner and is comparable with CTC with dry preparation.

Adenomatous Polyposis Coli↗

Radiofrequency ablation in pig lungs: in vivo comparison of internally cooled, perfusion and multitined expandable electrodes.

The purpose of this study was to compare the amounts of in vivo coagulation obtained by radiofrequency (RF) ablation in porcine lung, using three types of electrodes. 15 in vivo ablation procedures were performed in the lungs of five pigs using three kinds of currently available RF devices under CT guidance. After placing an electrode in the lung, three ablation zones were created at each of three different regimens: Group A: RF ablation with an internally cooled electrode; Group B: RF ablation with a perfusion electrode, with instillation of 0.9% NaCl solution at a rate of 1.5 ml min(-1); Group C: RF ablation with a multitined expandable electrode. According to the manufacturer's recommendations, RF application times were 12 min in group A and 20 min in group B. In group C, RF energy was delivered for 7 min after a mean temperature of 110 degrees C was reached at 5 cm deployment. 36 min after the procedures, contrast-enhanced CT scans were obtained to evaluate the volume of zone of coagulation, and lungs were harvested for gross measurements. After macroscopic and histopathological analyses of 5 mm-thick lung sections, diameters, volumes and variation coefficients of regions of central coagulation were assessed. During RF ablation, the perfusion electrode allowed a larger energy delivery than the internally cooled or the multitined expandable electrodes, i.e. 33.6+/-4.7 kJ in group A, 40.0+/-8.2 kJ in group B and 23.5+/-6.1 kJ in group C (p<0.05). On gross observation, the cut surface of the gross specimen containing RF-induced coagulation showed that the ablated tissue appeared to be a central, firm, dark-brown area surrounded by an irregular outer margin (approximately 3-10 mm thick) of bright red tissue. In vivo studies showed that RF ablation using the perfusion electrode achieved larger coagulation volume than RF ablation using the other electrodes (p<0.05): 7.2+/-4.1 cm3 in group A; 16.9+/-5.5 cm3 in group B; 7.5+/-3.3 cm3 in group C. The corresponding variation coefficients were 0.55, 0.31, and 0.45, respectively. Our study shows that RF ablation using a perfusion electrode achieves a larger coagulation volume with an irregular margin than RF ablation using internally cooled or multitined expandable electrodes in the porcine lung.

Animals↗

Small gastrointestinal stromal tumours with focal areas of low attenuation on CT: pathological correlation.

AIM: To describe the pathology of focal areas of low attenuation in small gastrointestinal stromal tumours on contrast-enhanced computed tomography (CT), and to investigate the association of these areas as predictors of malignant potential. MATERIALS AND METHODS: Contrast-enhanced helical CT images were obtained of 39 small (up to 5 cm) gastrointestinal stromal tumours. Focal areas of low attenuation were retrospectively evaluated and correlated with histopathological findings. The relation between the mitotic rate of and the presence of focal areas of low attenuation in the tumours was analyzed using Fisher's exact test. RESULTS: Of the 39 small gastrointestinal stromal tumours, 15 contained focal areas of low attenuation on CT. These were found to be due to solid tumour (n=5), haemorrhage (n=3), haemorrhage with necrosis (n=2), cystic degeneration (n=2), fluid in ulcer (n=2), and fibrous septum (n=1); they were not found to be associated with a high mitotic rate (p=0.45). CONCLUSION: Focal areas of low attenuation on CT in small gastrointestinal stromal tumours represent varying pathological conditions and do not predict malignant potential.

Adult↗

An ex-vivo experimental study on optimization of bipolar radiofrequency liver ablation using perfusion-cooled electrodes.

PURPOSE: To determine optimal parameters for bipolar radiofrequency ablation (RFA) using perfusion-cooled electrodes to create a large ablation volume in ex vivo bovine liver. MATERIAL AND METHODS: Three sets of RF experiments were performed using a 200-Watt generator and two 15-gauge perfusion-cooled or internally cooled electrodes in ex vivo bovine livers. In the first set of experiments, to find the ideal inter-electrode distance for creating large coagulation necrosis, 30 ablation lesions were created by bipolar RFAs at inter-electrode spacings of 3 cm, 4 cm, and 5 cm. In the second set of experiments, to explore the ideal duration of RF application, bipolar RFAs were performed for 10 min and 20 min. In the first and second experiments, 10 lesions were made for each condition with infusion of 6% hypertonic saline (HS) at 2 ml/min. In the third set of experiments, 10 ablation lesions were created by bipolar RFAs using internally cooled electrodes without HS infusion. The mean volume of those ablation lesions was then compared to that of the lesions created by bipolar RFA using perfusion-cooled electrodes in the second experiments. Tissue impedance, dimension, and shape of the ablated areas were compared in each condition. RESULTS: In the first set of experiments, bipolar RFA created a homogeneous oval or spherical-shaped ablation area between the electrodes at 3-5 cm spacing, but showed a more spherical-shaped lesion at 3 cm inter-electrode spacing than at 4 cm and 5 cm spacing. In the second set of experiments, RF energy delivered for 20 min created a larger dimension of coagulation necrosis than energy delivered for 10 min: 107.6 +/- 34 cm3 versus 59.5 +/- 27 cm3 (P<0.05). In addition, the mean volume of ablation regions obtained with bipolar RFA using the internally cooled electrode was 47.5+/- 17 cm3, which was significantly less than that with bipolar RFA using perfusion-cooled electrodes (P <0.05). CONCLUSION: Bipolar RFA using perfusion-cooled electrodes achieves homogeneous areas of coagulation necrosis between two electrodes, preferably at 3 or 4 cm inter-electrode distance for 20 min, and is better in creating large coagulation necrosis than bipolar RFA using internally cooled electrodes.

Analysis of Variance↗

Calcified Klatskin tumor mimicking intrahepatic stone: case report.

Calcification is a relatively uncommon manifestation of malignant liver neoplasm. Calcifications in peripheral cholangiocarcinomas but not in Klatskin tumor have been reported. We present a rare case of Klatskin tumor that had dystrophic calcification mimicking a intrahepatic stone in a 65-year-old man.

Aged↗

Real-time compound ultrasonography: pictorial review of technology and the preliminary experience in clinical application of the abdomen.

The purposes of this essay are to illustrate the technology overview and theoretical benefits of real-time compound ultrasonography (US) and to present our preliminary clinical experience in the evaluation of normal and diseased abdomens. The application of compounding principles to real-time US and its recent reintroduction into mainstream commercial systems have offered new opportunities for its clinical application to the routine examination of the abdomen. In our early preliminary experience, this technique effectively suppressed many of the US artifacts, better depicted the margin or boundary of the lesion, and increased contrast resolution or lesion conspicuity. Therefore, we believe that real-time compound US is a promising technique that may enhance the diagnostic confidence of the examination in the evaluation of normal and diseased abdomens.

Abdomen↗

Hepatic bipolar radiofrequency ablation using perfused-cooled electrodes: a comparative study in the ex vivo bovine liver.

The purpose of this paper was to demonstrate the efficacy of the dual probe bipolar radiofrequency (RF) system with the perfused-cooled electrodes inducing coagulation necrosis in the ex vivo bovine liver. The perfused-cooled electrode that allows simultaneous internal cooling and interstitial hypertonic saline perfusion has been developed for RF ablation (RFA). RF was applied to excised bovine liver in a bipolar mode at 150 W using a 200 W generator with two perfused-cooled electrodes for 10 min. After placing the electrodes at 3 cm spacing in the explanted liver, 45 ablation zones were created with three different regimens: Group A, using both intraelectrode cooling and interstitial perfusion; group B, using only the intraelectrode cooling; and group C, using only interstitial perfusion. In groups A and C, RFA was performed with the infusion of 6% hypertonic saline at the rate of 2 ml min(-1). During RFA, we measured the tissue temperature at the midpoint between the two electrodes. The dimensions of the ablation zones and the changes in impedance, currents and liver temperature during RFA were compared in these three groups. The mean tissue impedance during RFA in group A (56.7+/-21.7 Omega) and group C (56.9+/-20.6 Omega) was significantly lower than group B (112+/-19.7 Omega) (p<0.001). The mean current was higher in group A (1765+/-128 mA) than groups B (760+/-321 mA) and C (1298+/-349 mA) (p<0.05). In addition, the shortest vertical diameter of coagulation necrosis was greater in groups A (4.9+/-0.5 cm) and C (4.6+/-0.7 cm) than in group B (3.5+/-0.4 cm) (p<0.05). The temperature at the mid-point between the two probes was higher in group A than other groups: 99 degrees C in group A, 88.9 degrees C in group B, and 94.3 degrees C in group C (p>0.05). The ratios of the diameter of the long-axis to the diameter of the vertical-axis of groups A, B and C were 1.1+/-0.1, 1.2+/-0.1, and 1.1+/-0.2, respectively (p<0.05). Bipolar RFA using intraelectrode cooling and the interstitial saline perfusion simultaneously produced ablation zones significantly larger than the area produced by only one measure.

Animals↗

Abdominal amyloidosis: spectrum of radiological findings.

Amyloidosis is a disease characterized by the deposition of fibrillar protein amyloid of beta-structure in organs or tissues. It is usually classified as either a primary disease or secondary to a co-existent condition, such as rheumatoid arthritis, tuberculosis, or neoplasm (particularly multiple myeloma or renal cell carcinoma). Amyloid protein deposition can be seen in a variety of organs though it occurs with higher frequency in the gastrointestinal tract, kidney, and heart. Amyloidosis can have a wide spectrum of manifestations in nearly every abdominal organ. Some of these, for example, multiple cystic submucosal masses of the stomach, amyloidosis of the gallbladder, and dirty soft tissue infiltration of the subcutaneous fat, have not yet been covered in the radiological literature. The combination of various imaging techniques and the identification of characteristic computed tomography (CT) hepatic features may help in the differentiation of amyloidosis from other infiltrative diseases; however, confirmative diagnosis can usually only be achieved by tissue biopsy.

Adult↗

Heterogeneous distribution of cardioplegic solution in pigs.

Septal dyskinesia in the left ventricle is detected frequently in many patients after open-heart surgery. The present study was designed to determine whether the antegrade delivery of cardioplegic solution to the regional wall categorized in echocardiography is homogeneous, and whether the distribution to the septal wall differs from that to the lateral wall in the absence of coronary artery disease. To assess these hypotheses quantitatively, radioactive microspheres were mixed into the cardioplegic solution and infused by an antegrade method in eight normal pigs. The cardioplegic distribution to the septal wall was significantly less than to the lateral wall close to the base of the left ventricle (P<0.05). Therefore, antegrade perfusion of cardioplegic solution was non-uniformly distributed to the regional and transmural wall of normal pig hearts. Absence of functional correlation was a limitation of this study. However, these findings suggest that inadequate protection of the ventricular septum by antegrade cardioplegia might be an explanation for the abnormalities of septal wall motion after open-heart surgery.

Animals↗

Comparison of contrast-enhanced fundamental imaging, second-harmonic imaging, and pulse-inversion harmonic imaging.

RATIONALE AND OBJECTIVES: To investigate the feasibility of recent contrast-specific ultrasound techniques in depicting vascular flow and the effects of changing the output power of the transducer and insonation mode on contrast enhancement, the authors performed an experimental study with a flow phantom. METHODS: While changing the mechanical index and the sound insonation mode (continuous and intermittent), images were obtained with three contrast-enhanced ultrasound techniques: fundamental, second-harmonic, and pulse-inversion harmonic imaging (PIHI) after a bolus injection of microbubble contrast agent. The images were compared on a time-intensity curve. RESULTS: In assessing fixed flow (10 cm/s), PIHI showed the best depiction of flow signal. In intermittent scanning, increases in the mechanical index caused stronger flow signals and longer enhancement duration in all techniques. However, continuous scanning revealed poor depiction of flow signal regardless of the technique or changes in the mechanical index because of significant bubble destruction. CONCLUSIONS: Microbubble-enhanced PIHI with intermittent scanning at a high mechanical index can depict vascular flow highly effectively without shortening the duration of enhancement.

Blood Flow Velocity↗

Peripheral T-cell lymphoma of the colon: double-contrast barium enema examination findings in six patients.

PURPOSE: To evaluate radiologic findings of peripheral T-cell lymphoma (PTCL) of the colon at double-contrast barium enema examination. MATERIALS AND METHODS: Double-contrast barium enema findings in six patients with pathologically proved PTCL of the colon were retrospectively evaluated and compared with colonoscopic and histopathologic findings. RESULTS: There was a diffuse involvement of almost all segments of the colon in four patients and a focal segmental involvement in two. Frequent findings at double-contrast barium enema examination included geographic ulcerations (n = 6), aphthous ulcerations (n = 4), pseudopolyps (n = 4), circumferential luminal narrowing (n = 4), and ileocecal deformity (n = 4). CONCLUSION: PTCL of the colon manifested as either a diffuse or a focal segmental lesion and showed extensive mucosal ulceration at double-contrast barium enema examination. These findings are similar to those of inflammatory bowel disease and are different from those of colorectal lymphoma with the B-cell phenotype.

Adult↗

Hepatic hemangiomas with arterioportal shunt: findings at two-phase CT.

PURPOSE: To determine the prevalence of arterioportal shunt associated with hepatic hemangiomas, describe the two-phase spiral computed tomographic (CT) findings, and correlate the presence of arterioportal shunt with the size and rapidity of enhancement of hemangiomas. MATERIALS AND METHODS: The study group consisted of 109 hepatic hemangiomas in 69 patients who underwent two-phase spiral CT during 1 year. CT scans were obtained during the hepatic arterial (30-second delay) and portal venous (65-second delay) phases after injection of 120 mL of contrast material (3 mL/sec). Arterioportal shunts were diagnosed when hepatic arterial phase CT scans showed a wedge-shaped or irregularly shaped homogeneous enhancement in the liver parenchyma adjacent to the tumor and when portal venous phase CT scans showed isoattenuation or slight hyperattenuation, compared with normal liver in that area, and when there was no demonstrable cause of these attenuation differences. The presence of arterioportal shunt in hemangioma was correlated with the size of the tumor and the rapidity of intratumoral enhancement. RESULTS: Arterioportal shunt was found in 28 (25.7%) of 109 hemangiomas. There was no statistically significant relationship between lesion size and presence of the arterioportal shunt (P =.653). Arterioportal shunt was more frequently found in hemangiomas with rapid enhancement (P <.01). CONCLUSION: Arterioportal shunts are not uncommonly seen in hepatic hemangiomas at two-phase spiral CT. Hemangiomas with arterioportal shunts tend to show rapid enhancement.

Arteriovenous Fistula↗

Viable myocardium in reperfused acute myocardial infarction: rest and stress first-pass mr imaging.

Feasibility of identifying viable myocardium in rest and stress magnetic resonance imaging (MRI) was evaluated using 3 hr occlusion and 30 min reperfusion model of left anterior descending (LAD) coronary artery in 12 felines. At rest MRI, viable myocardium confirmed by 2,3,5-triphenyl tetrazolium chloride (TTC)-staining showed rapid signal intensity (SI) rise followed by gradual decline not significantly different from normal myocardium that the two hyperperfused regions were distinguishable only from the hypoperfused nonviable myocardium. At stress MRI, hyperemia induced perfusion change was most pronounced in normal myocardium with earlier and greater peak enhancement followed by brisk 'washout' phase while minimally augmented enhancement in viable myocardium was still in 'washin' phase. From these findings, it was concluded that viable myocardium is identified in rest and stress MRI as redistributing hypo- perfusion compared to persistent hyper-perfusion of the normal myocardium and the persistent hypo-perfusion of the nonviable myocardium.

Animals↗

Ultrasonographic evaluation of the gallbladder: comparison of fundamental, tissue harmonic, and pulse inversion harmonic imaging.

The purpose of our study was to compare pulse inversion harmonic imaging, tissue harmonic imaging, and fundamental imaging in the evaluation of normal and diseased gallbladder. Gallbladders in 170 patients were examined with fundamental imaging, tissue harmonic imaging, and pulse inversion harmonic imaging using a 2- to 5-MHz curved array transducer. Images were divided into normal and abnormal groups. The sharpness of the wall and degree of internal artifact were evaluated in normal groups, and lesion conspicuity and internal artifact were evaluated in abnormal groups. In images of both normal and abnormal gallbladder, significant differences were demonstrated among the 3 imaging methods (P < .001), and pulse inversion harmonic imaging provided the best image quality and the least artifact. Tissue harmonic imaging was the next best, providing better image quality and less artifact than fundamental imaging. In conclusion, pulse inversion harmonic imaging provided the best image quality and the least artifact among the 3 ultrasonographic methods in the evaluation of both normal and abnormal gallbladder.

Aged↗

Improved imaging of hepatic metastases with delayed pulse inversion harmonic imaging using a contrast agent SH U 508A: preliminary study.

To investigate the feasibility of delayed pulse-inversion harmonic imaging (PIHI) with the SH U 508A to improve imaging of hepatic metastases, we evaluated 20 patients with known hepatic metastases. Conventional ultrasound (US) was performed before administration, and PIHI was performed 5 min after a bolus injection of 4 G of microbubble contrast agent (300 mg/mL of SH U 508A). Intense, homogeneous enhancement in the liver parenchyma was seen in all patients on delayed PIHI. In 10 patients (50%), 1 or more focal liver lesions that were not seen on unenhanced imaging were detected on delayed PIHI. When comparing 55 lesions that were seen on both techniques, delayed PIHI was superior to unenhanced imaging in terms of lesion conspicuity and lesion-to-liver contrast (p < 0.001, respectively). Delayed PIHI with SH U 508A can improve conspicuity of hepatic metastases and reveal focal liver lesions that are not detected on unenhanced imaging.

Adult↗

Comparison of harmonic and conventional power Doppler ultrasonography for assessment of slow flow in hyperechoic tissue: experimental study using a Doppler phantom.

RATIONALE AND OBJECTIVES: Despite the advantages of depicting slow flow in small vessels, conventional power Doppler ultrasound (US) has a basic limitation, specifically that artifactual power Doppler signals mimic blood flow, especially in hyperechoic tissue. The purpose of this study was to compare harmonic power Doppler US with power Doppler US using a Doppler phantom under various parameter settings, focusing on the assessment of slow flow in the hyperechoic tissue. METHODS: While controlling the flow velocity (5 and 10 cm/s), pulse repetition frequency (500, 700, and 1,000 Hz), wall filter (low and medium), and Doppler gain (90%, 96%, and 100%), the authors performed both harmonic Doppler US and power Doppler US by using a Doppler phantom/flow control system. We measured and compared the relative intensities of the Doppler signals (0-250 scale) in both the vessels and hyperechoic tissue-mimicking materials with the two different imaging modalities. RESULTS: Power Doppler US with any combination of the four parameters evaluated depicted strong flow signals (mean, 213) that were superior to harmonic Doppler US (mean, 61). Relatively strong artifactual signals within the hyperechoic tissue-mimicking materials were noted on all power Doppler US studies (mean, 106) but nearly none on harmonic Doppler US (mean, 3). The contrast-to-noise ratio of harmonic Doppler US was significantly greater than that of power Doppler US. CONCLUSIONS: Harmonic Doppler US is more useful in assessing slow flow in hyperechoic tissue than power Doppler US because it produces fewer artifactual Doppler signals originating from stationary hyperechoic tissues, which can be misjudged as true signals on power Doppler US.

Blood Flow Velocity↗