[Clinical experiences with the hand-held keratometer].

BACKGROUND: In this investigation the clinical usefulness of an automatic handkeratometer was compared to well-known methods of corneal power measurement. Moreover, we examined the influence of the patient's position on the results. PATIENTS AND METHODS: One investigator measured 31 eyes of children in the age of 4-11 years (mean 6.3 y.) and 60 eyes of adults in the age of 22-71 years (mean: 48.3 y.) without corneal disorders consecutively by handkeratometer standing and lying, by autokeratometer and computerized videokeratography. Steepest (r1) and flattest (r2) radius, cylinder power and corresponding axis were subjected to statistical analysis. RESULTS: The mean values of the corneal radii (r1/r2) of the children were 7.63/7.82 mm for handkeratometer standing, 7.63/7.84 mm for handkeratometer lying, 7.62/7.84 mm for autokeratometer and 7.70/7.87 mm for videokeratoscope. The cylinder power was 1.11 dpt for handkeratometer standing, 1.09 dpt for handkeratometer lying, 1.23 dpt for autokeratometer and 0.95 dpt for videokeratoscope. Analysis of intraindividual variability produced by the instruments concerning astigmatism (dpt) showed in substraction for comparison of handkeratometer standing with handkeratometer lying 0.02 +/- 0.29 SD, of handkeratometer standing with autokeratometer -0.12 +/- 0.37 and of handkeratometer standing with videokeratoscope 0.16 +/- 0.35. A further comparison concerning cylinder (dpt) of handkeratometer lying with autokeratometer was -0.13 +/- 0.42 and handkeratometer lying with videokeratoscope 0.14 +/- 0.43. Difference comparison of astigmatism measurements in the 95% confidence interval (aspired difference of zero) demonstrated a high statistically significant relationship of handkeratometer standing (p < or = 0.0001) and handkeratometer lying (p < or = 0.0002) with the videokeratoscope. Mean values of the adult eyes (r1/r2) valued 7.56/7.76 mm in handkeratometer standing, 7.56/7.76 mm in handkeratometer lying, 7.57/7.78 mm in autokeratometer and 7.6/7.76 mm in videokeratoscope. The mean cylinder power with the corresponding axis was 1.15 dpt/80.5 degrees in handkeratometer standing, 1.15 dpt/77.8 degrees in handkeratometer lying, 1.15 dpt/78.3 degrees in autokeratometer and 0.95 dpt/75.2 degrees in videokeratoscope. CONCLUSIONS: The results and standard deviations of corneal power measurements of the handkeratometer were independent on patient's position and very similar to those of a common autokeratometer and videokeratoscope. Because of its quick and simple operation the handkeratometer was well accepted for corneal examination of children and can therefore be a useful alternative.

Adult↗

[A new site-independent tonometer (ProTon) in comparison with the Goldmann applanation tonometer].

BACKGROUND: A new position-independent and portable Mackay-Marg-tonometer in miniature, the so-called ProTon (PT), was compared with reference to its clinical usefulness with the Goldmann applanation tonometer (GAT), being a commonly accepted reference. METHODS: The intraocular pressure (IOP) in 164 eyes of 85 adults (patients and volunteers without ocular disease) was measured using the sequence GAT, PT and again GAT--each three times in a row-by three different investigators in a randomized scheme. In an attempt to detect any systemic influence, the difference obtained by subtracting the value measured using PT from the value attained using GAT was compared to the central corneal thickness and radius. Moreover, the central IOP readings were compared with the peripheral IOP in 60 eyes of 30 volunteers measured by PT, to detect any possible influence of the locality of measurement. Dependence of measurement on individual influences was examined by comparing PT-values obtained by each investigator. RESULTS: Linear regression analysis between PT (y-axis) and GAT (x-axis) for an IOP range of 0 to 62 mm Hg resulted in the following equation: PT = 1.036 x GAT -2.00 with a PT value standard deviation of 1.65 mm Hg (r = 0.988; p < 0.0001). Reproducibility of each of the three PT-values (mean pair difference of 1.1 mm Hg) corresponded to the analogous first two GAT-values (differences 1.0 up to 1.2 mm Hg). The mean IOP-value of 1) the GAT measurements (1 to 3) was 18.35 mm Hg, 2) of the last three GAT measurements, 17.15 mm Hg and 3) of all PT-measurements, 16.40 mm Hg. No statistical difference was found between the IOP measured centrally and peripherally. A clinically nonsignificant dependency for PT-readings on the examiner was verified. CONCLUSION: Due to the high reproducibility, independency on examiner and acceptable correspondence of PT with GAT values, the PT appears to be a promising new development for use in measuring intraocular pressure. It will be necessary to modify the calibration of PT since IOP measured systematically about 2 mm Hg too low.

Adolescent↗

[Alterations of heparin coating on intraocular lenses caused by implantation instruments].

BACKGROUND: In the last years heparin surface-modified intraocular lenses (HSM IOLs) were used for special indications like uveitis, synechia, congenital cataract or pseudoexfoliation syndrome. A monolayer of heparin molecules on the surface of PMMA-IOLs causes a reduced postoperative inflammatory reaction and produces a higher long-term biocompatibility than PMMA-IOLs without surface-modification. The study was designed to evaluate the possible damage of this heparin-monolayer on the PMMA-IOL by different metallic implantation forceps and different grasp-pressure. MATERIALS AND METHODS: Different implantation instruments were used to grasp HSM and conventional PMMA-IOLS. We designed a new device to generate and measure the pressure by the implantation forceps on the IOL in online-mode. After staining the heparin-monolayer with toluidin blue the surface alterations on the intraocular lenses were examined for surface alterations, especially of the heparin-monolayer, by light and scanning electron microscopy subsequently. RESULTS: Implant forceps produced defects of the heparin layer and the PMMA-material. Each implantation forceps induced a specific pattern of destructed heparin surface in the grasp area. These defects showed high correlation with the pressure and the morphology of the forceps as shown by light and scanning electron microscopy. CONCLUSIONS: Mechanical irritation during the implantation procedure destroyed the heparin layer on PMMA-IOLs in the grasp-area. Clinical consequences are not yet known, but possible. An instrument with rounded, soft and smooth grasp-surface is required for implantation of HSM IOLs to avoid surface alterations, so that the patients get maximum profit by the heparin-modification.

Cataract Extraction↗

[Endothelial cell loss after phacoemulsification and 3.5 vs. 5 mm corneal tunnel incision].

This prospective study was performed to compare the central endothelial cell loss (ECL) after phacoemulsification and 3.5 with 5 mm temporal clear-corneal incision. Moreover, the influence of ultrasound time and power on postoperative endothelial cell density was evaluated. PATIENTS AND METHODS. Sixty-two patients (age 71 +/- 7.7 years) without corneal pathology were operated by phacoemulsification (Storz, Premiere) with a temporal, self-sealing, two-step clear-corneal incision followed by posterior chamber IOL implantation under viscoelastic (1% sodium hyal-uronate). Thirty-one one-piece plate-haptic foldable silicone IOLs (Chiron C10; Staar Surgical AA-4203) were implanted by an injector through a 3.5 mm incision (group A). The other 31 PMMA IOLs (Pharmacia 809P) were implanted through a 5 mm incision (group B). One surgeon performed all operations with the same technique (bimanual phacoemulsification in the capsular bag). Sutureless wound closure was performed in group A, while the wounds in patients of group B were closed with a single radial stitch. The central endothelial cell counts were recorded preoperatively, on days 2-5 and 6 months postoperatively using contact specular microscopy. RESULTS. The collective data revealed a cell loss of 7.9% (+/- 4.1 SD) on days 2-5 postoperatively and 6.7% (+/- 2.9) after 6 months. A direct linear relationship was found to exist between ultrasound time (UT) and ECL. In group A (7 patients) the ECL slightly increased from 3.5% in the first week postoperatively to 3.8% after 6 months, operated under UT < or = 1 min 30 sec. The ECL decreased from 8.2% to 6.4% after 6 months in group A (19 patients), operated under UT of 1 min 30 sec, and from 10.8% to 8.9% under UT of 2 min 31 sec-3 min 30 sec (5 patients). The ECL in group B decreased from 6.3% in the first postoperative week to 5.4% 6 months postoperatively, operated under UT < or = 1 min 30 sec (10 patients), from 8.1% to 7%, operated under UT of 1 min 31 sec-2 min 30 sec (14 patients), and from 11.2% to 10.4% under UT of 2 min 31 sec-3 min 30 sec (7 patients). CONCLUSION. Endothelial cell loss of 6.7% after phacoemulsification through a temporal clear-corneal incision compares favorably with other series in which cell loss was determined following cataract surgery with or without IOL implantation. Phacoemulsification and 3.5 mm clear-corneal incision evoked less ECL of 6.2% compared with phacoemulsification and 5 mm clear-corneal incision with ECL of 7.3% after 6 months.

Aged↗

[Effects of Nd:YAG microexplosions on heparin-coated PMMA intraocular lenses].

UNLABELLED: Surface modification of intraocular lenses (IOL) have improved the quality of cataract surgery. Heparin surface-modified (HSM) IOL are implanted for special indications (e.g., recurrent uveitis, cataract surgery for children, preoperative synechia) because of decreased postoperative inflammatory reactions and higher long-term biocompatibility. Nevertheless, secondary cataract, precipitates and fibrinous membranes appear. The YAG laser is used for treatment. METHODS: PMMA intraocular lenses with or without a heparin monolayer were exposed to Nd:YAG laser. The experiment was performed under BSS using different energy levels and distances to the IOL. The heparin monolayer was stained with toluidin blue. Subsequently, the surface of the intraocular lenses was examined with light and scanning electron microscopy. RESULTS: The YAG laser marks of HSM IOL and PMMA IOL showed no morphological differences. Microexplosions and pressure waves of the Nd:YAG laser cleared parts of the heparin monolayer in the area of the laser spots dependent on energy distance to the IOL. Even "breakdown" behind the HSM IOL without any PMMA lesion shown circular destruction of the heparin monolayer. CONCLUSIONS: The heparin surface defect of HSM IOL after YAG laser treatment should be taken into consideration, because a decreased heparin effect in vivo could be possible.

Heparin↗

[The anti-inflammatory effect of heparin-containing infusion solutions during phacoemulsification].

UNLABELLED: The use of heparin prevented postoperative intraocular fibrin-clot formation in the rabbit after vitrectomy and cyclocryotherapy. A low rate of postoperative intraocular inflammation was observed in our patients receiving phacoemulsification with heparin infusion solution (slit-lamp examination). To verify this effect a randomized, prospective study was performed using laser-flare cell photometry (LFCP) for measuring protein concentration in the anterior chamber. PATIENTS AND METHODS: Seventy-two patients (49-87 years of age) were randomly assigned to one of the following two surgical groups (temporal clear corneal tunnel incision with phacoemulsification): group A: foldable silicone IOL (Chiron C10), no stitch (3.5 mm incision); group B: PMMA-IOL (Pharmacia 809P) with one radial suture (5 mm incision). Fifty percent of the patients in each group received, in addition to the regular phaco infusion, 1 ml of heparin sodium (-H = without heparin; +H = with heparin). Aqueous flare was measured preoperatively as well as on days 1 and 3 following phaco + IOL with LFCP (Modell FC-1000; Kowa Company). RESULTS: In group A1 (-H) or B1 (-H) the mean flare values (in photon counts/ms) increased from a preoperative value of 7.0 +/- 1.7 (mean +/- SD) or 6.9 +/- 1.2 to 20.2 +/- 3.1 or 20.1 +/- 3.0 on the 1st postoperative day, whereas they decreased again to 13.8 +/- 2.9 or 14.8 +/- 3.1 on day 3 following surgery. In groups with heparin sodium A2(+H) and B2(+H) the flare values only increased from 7.2 +/- 1.3 or 7.1 +/- 1.3 to 12.9 +/- 4.0 or 13.8 +/- 3.8 on day 1, and decreased to 8.0 +/- 2.8 or 8.8 +/- 3.0 on the 3rd postoperative day. The mean postoperative flare values were significantly lower in the groups with additional heparin (p < 0.01). CONCLUSIONS: Heparin sodium in the infusion solution during small incision cataract surgery showed an antiinflammatory effect in the early postoperative period. There was no significant difference between the two IOL materials.

Aged↗

[Long-term outcome after silicone oil removal].

In order to reduce the incidence of postoperative complications in silicone-filled eyes, many authors recommend that silicone oil should be removed from the eye as soon as a stable retinal situation is achieved. Even in the eyes with completely attached retina and a clinically stable situation there is a risk of retinal redetachment and other complications after silicone oil removal. In a retrospective study we analyzed 324 cases after silicone oil removal regarding the postoperative redetachment rate and risk of complications from this procedure. The indication for primary surgery was retinal detachment with PVR in 167 (51.5%) cases, proliferative diabetic retinopathy in 87 cases (26.8%), complications of penetrating ocular injuries in 48 cases (14.8%), giant tear retinal detachment in 9 cases (2.7%) and retinal detachment with a central hole in 13 cases (4%). At the time of silicone oil removal retina was completely attached in 277 eyes. Local retinal redetachment central to the encircling band existed in 47 eyes at the time of silicone removal. Follow-up time ranged from 6-63 months. Silicone oil removal was combined with a cataract operation in 42 cases (12.9%), penetrating keratoplasty in 9 cases (2.8%) and membrane peeling in 54 eyes (16.7). In the postoperative period the retina detached in 39 (12%) eyes. In the eyes with preoperatively completely attached retinas, redetachment occurred in 23 eyes (8%), whereas in the group of eyes with an unstable preoperative retinal situation, the retina redetached in 16 eyes (34%). The duration of the silicone oil tamponade had no effect on the redetachment rate. In the group of eyes with an unstable preoperative retinal situation, preoperative laser photocoagulation at the cerelage buckle, as well as central to the local detachment, reduced the incidence of redetachment after silicone oil removal significantly (25% vs. 53%). In the group of eyes with a preoperatively stable retinal situation, this effect was not significant. Our results show that in eyes with completely attached retinas, the risk of complications and redetachment after silicone oil removal is relatively low. In selected cases, even in eyes with incompletely attached retinas, silicone oil could be removed. Nevertheless, a relatively high risk of postoperative complications has to be taken into consideration. In eyes with an incompletely attached retina, preoperative laser photocoagulation at the cerclage buckle, as well as central to the local redetachment significantly reduced the incidence of redetachment after silicone oil removal.

Adult↗

[Changes in bulbus geometry after conventional detachment surgery. Study using video keratoscopy].

Conventional detachment surgery produces scleral indentation and can therefore lead to changes in the geometry of the bulbus. The aim of this research was to analyze the influence of scleral buckling (group A) and encircling elements (group B) on corneal topography, surgical induced astigmatism and axial length. In 19 cases with peripherally detached retinas we performed keratometry, videokeratoscopy and measured axial length preoperatively in the first week as well as 1 and 3 months postoperatively. Total preoperative astigmatism in group A was 0.49 D and in Group B 0.84 D. The surgically induced astigmatism calculated by vectoral analysis was in the first postoperative week 0.98 D and 1.92 D. 1 month postoperatively it was 0.74 D and 1.26 D, and after 3 months 0.89 D and 1.31 D. There was minimal change in the average axial length: 0.09 mm reduction in group A and 0.21 mm increase in group B after 3 months. Computerized videokeratoscopy was very effective in determining this slight, surgically induced astigmatism.

Astigmatism↗

[Systemic complications and side effects of retrobulbar anesthesia in risk patients].

BACKGROUND: Serious systemic complications with possibly lethal exit after retrobulbar anesthesia have been reported. The present study was performed to evaluate the incidence of complications after anesthesia in risk patients with pre-existing diseases. 2.8% of 3000 cataract operations in our department during October 1991 to April 1993 were performed under general anesthesia, 97.2% under local anesthesia. PATIENTS AND METHODS: 1000 anesthesia protocols of these cataract operations under retrobulbar anesthesia and facial block with anesthesia stand-by were analyzed retrospectively. After retrobulbar injection in Atkinson technique we performed a modified O'Brien facial block. The patients were assigned to five different risk groups on the basis of a special point system. RESULTS: The mean age of the patients increased with the risk group from 60.4 years in group 1 to 77.1 years in group 5. Cardiovascular, pulmonary and general risk factors appeared more frequently in the groups of higher risk. The frequency of cardiovascular complications was dependent on affiliation to risk group. The percentual frequency of cardiovascular complications increased from 1.7% in risk group 1 to 7.7% in risk group 5. Decrease of heart rate or blood pressure of more than 30%, or in combination, with the necessity of medical treatment occurred absolutely and relatively most frequently. The frequency of cardiovascular complications amounted 2.2% in the mean. Life-threatening complications with the need of endotracheal intubation or other occurred in 0.1%. CONCLUSION: The relatively high total frequency of systemic complications of 2.4% is related with age and preexisting diseases. The results underline the necessity of anesthesia stand-by in risk patients with the essential requirements for treatment of typical complications.

Aged↗

[A simple and rapid method for photographic documentation of findings using the slit lamp].

UNLABELLED: The objective photographic documentation and follow-up examination of changes in the eye's anterior segment is gaining importance as part of the daily practice. Until now, however, it has been linked with specially designed and expensive photographic equipment. A large number of ophthalmic units around the world do not have access to any form of photography. The advances in videographics do not offer an adequate alternative concerning both fineness of the grain and price per picture. MATERIAL AND METHODS: After installation of a new slit-lamp camera adapter, it was possible to produce color prints and slides. A 35-mm SLR camera with a spot-metering system, a clear view-finder focusing screen, highly sensitive slide film (ISO 640/29 degrees) and a standard 50 mm lens was used. No additional light sources or flashes were necessary in this camera-slit-lamp combination. CONCLUSION: This system is suitable to take color photographs of good quality and makes ophthalmic photography readily available, particularly in circumstances where more sophisticated photographic equipment is not available. Because of the fast and easy installation and the additional use for gonioscopic or fundus photography this combination is profitable even for inexperienced photographers.

Anterior Eye Segment↗

[Scanning electron microscopy examination of 87 pre-injection blunted retrobulbar cannulas].

UNLABELLED: The use of blunt cannulas for retrobulbar injection (retro) is recommended to reduce the risk of retrobulbar hemorrhage and globe perforation. Retro cannulas with blunt tips--so-called Atkinson needles--are commercially available. They can also be produced by being blunted on a sterile surface immediately before injection. METHODS: In a prospective study, all retro cannulas (0.5 x 40 mm, Steriseal) used over 8 days in our hospital were collected after being blunted on a sterile Petri dish, followed by injection. Subsequently, scanning electron microscopic examination was performed. 20 unused retro needles were examined for control. RESULTS: 62% (n = 54) of the 87 used retro cannulas were satisfactory, i.e., the tips were blunted, exhibiting no undesirable hooks. 29% (n = 25) of the retro cannulas demonstrated moderate deformation, 9% (n = 8) stronger deformation of the needle tip. No complications occurred after any of the 87 injections. CONCLUSIONS: Blunting of retro cannulas immediately before injection is a possible alternative to commercially available needles with blunt tips. However, this procedure has to be performed carefully to avoid potential detrimental deformation of the needle tip, which can be detected in a low percentage by means of the scanning electron microscope.

Anesthesia, Local↗