Search PubMed⌕ Search

Biomedical subjects

B Dick

Publications and source records attributed to B Dick.

At least 55 records · Page 3Linked to original sources

[Endophthalmitis after intra-oral block of the infraorbital nerve].

BACKGROUND: Most penetrating needle puncture injuries occur in retro- or peribulbar anesthesia. Hereby only a small percentage of patients develop endophthalmitis. Ocular penetration after enoral infraorbital nerve block has not yet been reported in literature. HISTORY AND FINDINGS: In June 1995 a 74-year-old man presented with a fulminant fibrinous and purulent endophthalmitis. Because he suffers from trigeminal neuralgia his anesthesiologist performed an infraorbital nerve block from enoral two days ago. During this procedure the patient felt a sharp ocular pain. THERAPY AND OUTCOME: We suspected an ocular penetration and performed a vitrectomy with intravitreal antibiotic instillation on the admission-day. A needle penetration site near the inferior rectus muscle was detected and after exocryocoagulation a 5 mm wide radial buckle was sutured over penetration site. Three months postoperatively vision recovered from hand moving to 20/50 and all infiltrations had been disappeared. Only preexisting cataract prevented a better vision. 10 months later after successful cataract extraction with intraocular lens implantation patient left hospital with a vision of 20/30. CONCLUSION: Careful anamnesis would have prevented this accidental globe penetration. Right upper palate is absent presumably due to congenital cleft malformation or surgery. This allowed needle penetration through smooth tissue into the right globe. Fortunately, endophthalmitis develops only in a small percentage after needle puncture. We recommend immediate pars-plana-vitrectomy and intravitreal antibiotics in case of endophthalmitis after ocular penetration.

Aged↗

[Long-term outcome after implantation of various intraocular lenses through a corneal tunnel].

UNLABELLED: A prospective, randomized study was carried out to evaluate functional and biomicroscopic long-term results of different posterior chamber intraocular lenses (IOLs) over a period of two years after clear corneal cataract surgery. PATIENTS AND METHODS: 2 years after phacoemulsification through a temporal two-step clear corneal incision a total of 67 patients were examined. In 26 eyes (group A) a foldable plate-haptic silicone IOL (Chiron Adatomed, C10), in 25 eyes (group B) a foldable disc silicone IOL (Chiron Adatomed, 90D) had been implanted through a 3.5 (group A) or 4 mm (group B) corneal incision using a cartridge injector. In 16 eyes (group C) a one-piece PMMA-IOL (Pharmacia & Upjohn, 809C) had been implanted through a 5 mm incision. All eyes underwent functional and biomicroscopic examinations, as well as computerized videokeratographic analysis to obtain corneal topography data. RESULTS: In group A uncorrected visual acuity valued 0.64 (+/-0.29 SD), in group B 0.59 (+/-0.24) and in group C 0.56 (+/-0.27). Median of uncorrected visual acuity was 0.6 for all groups. Corrected visual acuity was 0.81 (+/-0.29) in group A, 0.8 (+/-0.25) in group B and 0.83 (+/-0.3) in group C. Intraocular pressure (mm Hg) was 13 (+/-2.5) in group A, 14.7 (+/-2) in group B and 15.1 (+/-2.5) in group C. Fibrosis of the anterior capsular rim occurred in 42% of the cases. One eye demonstrated folds in the posterior capsule (group B). Posterior capsular opacification valued 11.9% for all groups. In one eye a Nd:YAG-capsulotomy had already been performed. In group A a decentration of more than 1 mm was objected in one case, in group B in two cases and in group C in one case, but no patient complained about any functional impairment. Two years postoperatively, no signs of a re-flattening in the incision area could be detected using difference mapping tools in the videokeratographic analysis. CONCLUSION: Two years after implantation of foldable silicone IOLs and PMMA-IOLs via a temporal clear corneal tunnel incision after phacoemulsification only slight functional and morphologic differences between the three IOL-types could be observed.

Aged↗

[Interaction of silicone oil with various intraocular lenses. A light and scanning electron microscopy study].

BACKGROUND: Silicone oil is increasingly used as an intravitreal tamponade in severe forms of vitreoretinal disorders, also in pseudophakic eyes. In some patients silicone oil was observed to be adherent to the intraocular implant. MATERIAL AND METHODS: To investigate the interaction of silicone oil with IOL-materials and the influence of lipoproteins of the serum on this interaction we used the following in vitro experimental set-up: Sterile IOLs of different IOL-materials (e.g. PMMA, silicone, hydrogel) and surface-modifications (e.g. Pharmacia 809P and 809C, Soflex LI41U, Alcon AcrySof M60BM, Allergan SI-30NB, SI-40NB, Chiron adatomed 90D, C10 and C31UB, MemoryLens U940A, Corneal ISHEMA 66, Storz H60M) were stored in vitro together with silicone oil (1000 centistokes) with and without a fresh serum solution at 37 degrees Celsius. This combination was rotated slowly and mixed thoroughly three times a day. After 3 and 6 months and a standardized special preparation in an ultrasound bath and air treatment, the IOLs were examined by light microscopy followed by scanning electron microscopy. RESULTS: Silicone oil strongly adhered to holes and to the IOL surface especially in silicone and PMMA IOLs. Highly hydrophylic IOLs-like the heparin-surface-modified and hydrogel IOL-cleared from silicone oil relatively early. This effect was more pronounced in the group with lipid-/serum solution than without. In some silicone IOLs silicone oil was strongly adherent to the lens and it was nearly impossible to wash off the oil even when using an alcoholic solution. One silicone IOL lost its haptics in the serum-oil-IOL-mixture, another lost small particles from the IOL surface. CONCLUSION: Silicone oil is more adherent to hydrophobic IOLs than to hydrophylic IOLs. Lipoproteins of the serum play an important role in facilitating an effect of silicone oil on IOL materials. We recommend highly hydrophylic especially surface-modified IOLs for lens implantation following vitreoretinal silicone oil surgery. Implantation of silicone IOLs in vitreoretinal high risk eyes should be avoided.

Equipment Failure Analysis↗

[Extent of damage to different intraocular lenses by neodymium:YAG laser treatment--an experimental study].

BACKGROUND: Neodymium:YAG laser capsulotomy frequently damages the intraocular lens (IOL). This damage, mainly caused by acoustic shock wave and thermal conduction, results in opacities in the IOL, which may cause glare or image degradation. Because of the introduction of new IOL materials in cataract surgery, investigation of YAG laser resistance of these IOL materials seems to be necessary. MATERIALS AND METHODS: A total of 17 standard IOLs of different types and classes of materials were tested as follows: Class I: Acrylate a) PMMA, compression molding, b) PMMA, compression molding, heparin-surface modified, c) acrylate/methacrylate copolymer; Class II: Silicone: a) Polydimethylsiloxane, b) Polydimethyldiphenylsiloxane; Class III: Hydrogel: a) poly-hydroxyethylmethacrylate (poly-HEMA), b) polyacrylate-hydrogel; Class IV: Thermoset polymer: methylmethacrylate, hydroxyethylmethacrylate, ethylene glycol dimethacrylate. Each IOL was placed in a rectangular transparent acrylic test chamber filled with balanced salt solution and subjected to irradiation from a Q-switched Nd:YAG laser. The laser beam was focused on the posterior surface and inside of the IOLs. The optic of the IOL was divided into four target zones and each zone was subjected to 40 bursts inside the lens and 40 bursts on the posterior surface of the lens. Laser power settings were: 1.1 mJ, 1.1 mJ with 0.4 mm defocus, 2.1 mJ and 4 mJ and one burst was applied (wave length 1064 nm, fundamental mode, duration 7 +/- 2 nanoseconds, spot size 15 microns in air). Following exposure, each lens was examined by light microscopy for the interior damage and by scanning electron microscopy for the posterior surface damage. For quantitative analysis, the extent of each superficial damage was evaluated by an image analysis system using at least original magnification x 1400. RESULTS: Each IOL material demonstrated specific morphologic damage patterns. Intralenticular damage: Class I: cracks with radiating fractures with smaller extent in group Ic; Class II: blistered snowball-like inclusions; Class III: localized small holes, exception: IIIb: with very short radiating fractures; Class IV: stellar pits with short radiating fractures. For silicone superficial posterior damage sites a splash crater pattern with irregular melted edges was observed, while acrylate damage sites demonstrated a melted or stellate crater pattern with slightly raised edges. The silicone, poly-HEMA and the acrylic IOLs containing HEMA presented highest YAG laser resistance with the smallest amount of posterior damage in comparison to PMMA-IOLs. There was no marked increase in damage size in these IOL materials with higher energy exposure in this set-up. CONCLUSION: For each material consistent and characteristic specific morphologic damage patterns were observed. Foldable optic materials were more resistant against Nd:YAG-laser photodisruption than rigid optic materials. Individual laser strategies for each IOL-material and design should be deducted.

Capsulorhexis↗

[Reflections on Nd:YAG capsulotomy in lens opacity after multifocal lens implantation].

BACKGROUND: Posterior capsule opacification (PCO) after implantation of a multifocal intraocular lens (MIOL) reduces the visual acuity (VAF) for the far, as well as for the near (VAN). There is no report on results and techniques for Nd:YAG capsulotomy in the presence of PCO after MIOL implantation. PATIENT AND METHODS: Therefore, 31 Nd:YAG capsulotomies in 29 patients with PCO after MIOL implantation were analysed concerning number of expositions, energy, MIOL-damage, results as well as complications after capsulotomy in order to derive individual laser strategies. RESULTS: Nd:YAG capsulotomy was performed after a mean of 14 (+/- 12.5) months. All capsulotomies resulted in a central opening of the posterior capsule. 42 (+/- 25.1) impulses in mean were necessary at a total energy of 71.7 (+/- 47.8) mJ. An average of 4 hits of the MIOL optic occurred and in 5 cases the MIOL remained undamaged. Three capsulotomies were difficult to perform. In eight cases, a dense PCO was present. All capsulotomies were performed without any immediate complication. In 93.6% VAF and in 96.8% VAN increased postoperatively, while in the remaining cases VA did not increase due to other reasons. In one case intraocular pressure increased after YAG laser treatment for a short period of time. In another case, a retinal detachment occurred 5 months postoperatively. No cystoid macular edema occurred until 6 months postoperatively. CONCLUSION: Nd:YAG capsulotomy in PCO after MIOL implantation is a relatively safe, non-invasive method to improve visual acuity. After capsulotomy, the optically effective area of the MIOL mainly depends on the diameter of the pupil, the anterior and posterior capsular opening. Therefore, the opening of the posterior capsule should depend on the individual MIOL design and should include the main MIOL portion for the far and near focus. This allows the patient an unaided profit from the multifocality of the IOL postoperatively.

Aged↗

[Experiences with the hand-held autorefractometer "Retinomax" in adults and children].

BACKGROUND: A measurement of ametropia with a table-top mounted autorefractor can be difficult or impossible on children--especially when the children are very young or handicapped. A hand-held autorefractor, however, may be successfully applied in some of these problematic cases. METHODS: Results of comparative measurements are presented concerning the accuracy and applicability of the hand-held autorefractor. The data were obtained on healthy young adults (100 eyes) and children (age 2-10 years, 50 eyes). In the group of adults, the autorefractor readings (obtained with a Retinomax K-plus) were compared with the results of subjective refractions. The effectiveness of the technique to relax accommodation was also evaluated. All children were measured with a Retinomax in cycloplegia. Here, retinoscopy and a conventional autorefractor served as reference methods. The accuracy of measurement was analysed by using the following criteria: "Difference of the spherical equivalents" (delta SA), "difference of the cylinder powers" (delta C), "axis difference" (delta A), and "difference of the cylindrical corrections" (delta CK). RESULTS: a) Adults: On average, the spherical equivalent of the autorefractor was +0.28 D larger than the subjectively obtained value. In 88% of all cases, the difference of the spherical equivalents fell into the interval [-0.25 D, +0.75 D]. delta C and delta A were < or = +/- 0.5 D in 95% and 87% respectively. b) Children: When compared with retinoscopy, delta SA fell into the interval [-0.25 D, +0.75 D] in 72% of all cases. delta C and delta A were < or = +/- 0.5 D in 86% and 87% respectively. CONCLUSIONS: The accuracy of measurement of the handheld autorefractor is comparable to conventional table-top autorefractors. As it is also applicable in some problematic cases, such as small children, on whom objective refraction data can not be obtained with ordinary autorefractors, it seems to be a valuable addition to the existing set of ophthalmic refraction devices.

Adult↗

A new method for direct detection of heparin on surface-modified intraocular lenses. A modification of Jaques' toluidine blue staining method.

BACKGROUND: Examination of surface-bound heparin on synthetic polymers can only be performed by few staining methods. These methods are limited by an only approximate detection of heparin visible at high magnification. Other methods only measure heparin quantitatively (per square dimension) and are rather sensitive to artifacts. Due to its homogeneous staining pattern, the modified toluidine blue staining technique, using a non-protein-based substance, allows examination and analysis of the homogeneity of the monomolecular heparin layer even under critical conditions like scanning electron microscopy. MATERIALS AND METHODS: For critical examination of the heparin layer, this method was used for 5 sterile heparin surface-modified (HSM) monofocal (Pharmacia, 809C, 5 mm optical zone), 2 multifocal PMMA (Pharmacia, 811E, 6 mm optical zone) and 1 standard PMMA intraocular lenses (IOLs; Pharmacia, 809P, 5 mm optical zone). A special mixture containing a sodium borate buffer was used to avoid cross-reactions of toluidine with phenylimines, which permit a covalent surface linkage of heparin to synthetic polymeric materials via reductive amination. This resulted in less coarse-grained complex agglutination. After light and spectral microscopy of the surface of stained IOLs, scanning electron microscopy was performed to investigated the reliability and validity of this modified staining method. RESULTS: All HSM IOLs showed a homogeneous heparin structure and coating, which could be demonstrated even under critical photographic circumstances. CONCLUSIONS: The modification of the original toluidine blue staining method introduced by Jaques in 1943 is a reliable and reproducible technique for the detailed in vitro analysis of surface-bound heparin with a low artifact rate. Because of the detailed detection of heparin on polymeric surfaces, this staining method is recommended for special problems, e.g. in cataract surgery.

Coloring Agents↗

[Endophthalmitis after cataract surgery: long-term follow-up].

BACKGROUND: Endophthalmitis is a serious complication after cataract surgery. PATIENTS AND METHODS: Therefore, a retrospective study was performed by reviewing patient-records of all cases of end-ophthalmitis after catract surgery that were treated at the department of ophthalmology of the University Hospital in Mainz between January 1986 and December 1995. RESULTS: 44 eyes were treated for endophthalmitis. Of those, 38 had been referred. In 15 eyes cataract surgery was performed on an outpatient basis. In 20 cases the onset of end-ophthalmitis occurred within the first postoperative week. We isolated staphylococcus epidermidis (14), staphylococcus aureus (4), other gram-positive microorganisms (15), gram-negative bacteria (2) and candida (1). As risk factors we found a wound dehiscence (14), an intraoperative loss of vitreous (11), diabetes (11), skin-diseases like rosacea or neurodermatitis (6). In 36 cases a vitrectomy was performed. After a mean follow-up of 25 +/- 22 months 26 patients had a visual acuity of 0.05 or better. CONCLUSION: Gram-positive bacteria showed to be the most common causetive microorganisms. In a third of all cases the sample demonstrated no growth. More than 80% of the eyes were treated by vitrectomy. About 60% of the patients obtained a visual acuity of 0.05 or better.

Adult↗

[Glare sensitivity of phakic and pseudophakic eyes].

BACKGROUND: Glare disability and appearance of halos may be side-effects of cataract, but were also described in patients with multifocal IOLs. The aim of this study was to compare glare sensitivity and halo size in phakic and pseudophakic eyes. PATIENTS AND METHODS: Contrast sensitivity without and with glare and halos around a light source were measured by means of a new computerized test in patients with cataract, monofocal IOLs, multizonal progressive and diffractive multifocal IOLs as well as in a younger control group of subjects with clear lenses. Glare acuity was measured at three different luminance settings. RESULTS: Patients with cataract showed the most important reduction in contrast sensitivity, noticed significantly larger halos and were more impaired in glare acuity than patients with monofocal or multizonal progressive IOLs. There was no significant difference in any criteria between these two pseudophakic groups. Subjects with a clear cristalline lens had statistically significant better results compared with all other groups. CONCLUSION: An increase in glare sensitivity and the appearance of halos are more important in patients with even minor cataracts than in any pseudophakic population. As a consequence of this study, night driving ability should be carefully examined in any pseudophakic patient, but also in any subject with even beginning cataract.

Adult↗

[Establishing a clinical information system for surgical ophthalmology and orthopedics specialties with reference to GSG '93].

BACKGROUND: As a result of new health care guidelines (Gesundheitsstrukturgesetz) and the federal hospital and nursing ordinance, there has been a large increase in the documentation required for diagnoses (ICD-9) and service ("Operationenschlüssel nach section 301 SGB V" = ICPM), all of which is done in the form of a numeric code. The method of coding diagnoses is supposed to make possible data entry and statistical evaluation of plausibility controls, as well as conspicuous and random testing of economic feasibility. Our data processing system is designed to assist in the planning and organization of clinical activities, while at the same time making documentation in accordance with health care guidelines easier and providing scientific documentation and evaluation. METHOD: The application MedAccess was developed by clinicians on the basis of a relational client-server database. The application has been in use since June 1992 and has been further developed during operation according to the requirements and wishes of clinic and administrative staff. In cooperation with the Institute for Medical Information Technology, a computer interface with the patient check-in system was created, making possible the importing of patient data. The application is continuously updated according to the current needs of the clinic and administration. The primary functions of MedAccess include managing patient data, planning of in-patient admissions, surgical planning, organization, documentation (surgery book, reports with follow-up treatment records), administration of the tissue bank, clinic communications, clinic work processing, and management of the staff duty roster. RESULTS: Clinical data are entered into a computer and processed on site, and the user is assisted by practical applications which do not require special knowledge of data processing or encoding systems. The data is entered only once, but can be further used for other purposes, such as evaluations or selective transfer, for example, to clinical documents. Through an integrated flow of data, information entered one time remains readily available, while, at the same time, preventing duplicate entries. The integration of hardware and software via a mainframe computer (clinic system WING) has proven to be well-suited for the exchange of data. CONCLUSION: The use of this thesaurus-supported and graphics-oriented system required no special knowledge of the ICD code and makes documentation much easier to produce. The advantages of computer-supported encoding not only include a savings in time, but also an improvement in the quality of the encoding from which clinical and scientific reports can be derived. The relational client-server, operating in a graphics-supported programming environment, makes it possible for the clinic's doctors to further develop and improve the system. Through the installation and support of a Macintosh network, and training of doctors, medical personnel and clerical staff, cost as well as investment of time have been kept to a minimum in comparison to other LAN servers.

Data Collection↗

[The "Array" silicone multi-focal lens: experiences after 150 implantations].

BACKGROUND: The Array-MIOL offers the advantage of an increased depth of focus; the aim of our study was to compare other functional results with those of a monofocal IOL. METHODS: Uncorrected and corrected distance and near visual acuity were measured in the early postoperative period and after 3 months. Results of contrast acuity (Regan charts) and contrast sensitivity (BVAT II-SG video acuity tester) of the Array-MIOL and a monofocal IOL were compared at the 3-months follow-up. RESULTS: Distance visual acuity of the multifocal group did not differ from the monofocal results; uncorrected and distance corrected near acuity were significantly superior in Array patients. The monofocal IOL showed a superior contrast acuity only at the 11% level and a superior contrast sensitivity only at one spatial frequency (20 cpd). Bilateral implantation of the Array-MIOL seems to further improve functional results. CONCLUSION: Implantation of the Array silicone multifocal IOL offers the advantage of pseudoaccommodation without relevant impairment of other visual functions.

Aged↗

[Resources on the Internet in Ophthalmology].

BACKGROUND: In the age of information, the Internet became a powerful, fast and international information resource. The ease with which individuals can access the Internet and with which institutions can make information available explains its exponential growth in the past few years. It is our purpose to provide ophthalmologists with new opportunities and to explore the potential and different functions for the information superhighway with a focus on information resources available to the ophthalmologist like the World Wide Web. RESULTS: By using the computer programme Netscape one can send or obtain reports or images, consult colleagues, perform a literature search, take part in an ophthalmological congress or discussion- and newsgroup, get information about past and ongoing ophthalmological events or, moreover, achieve product and company information. CONCLUSIONS: The Internet transformed the way we view and use information by a dramatic expansion of the ways ophthalmologists interact with their colleagues. Thereby, the use of the Internet and its vast resources will greatly improve the quality of patient care.

Computer Communication Networks↗

[Objective determination of refractive changes in silicon oil filled eyes--effect of head position on refraction].

BACKGROUND: The refraction of the eye is altered significantly after silicone oil instillation into the vitreous cavity due to its high refractive index. The degree of the refractive change varies during the daily course and depends on the position of the head. PATIENTS AND METHODS: To analyze the degree and time course of the refractive change depending on the head position we performed refractive measurements in 5 aphakic and 5 phakic silicone oil-filled eyes with attached macula by an automatic handrefractometer. This new device was used for 25 measurements at short intervals in each patient at different eye positions (supine position, prone position and primary eye position). RESULTS: Mean visual acuity in all patients valued 0.14 (+/- 0.05). The highest shift in refraction of +5.95 (+/- 2.63) dpt in spherical equivalents occurred in the aphakic eyes and of +2.45 (+/- 0.71) dpt in the phakic eyes after position change from face up to face down. Three minutes after position change the refraction remained stable in nearly all eyes. Only slight changes in cylinder and corresponding axis were found during the measurements with a mean axial shift of 10.1 (+/- 5.1) degrees. CONCLUSION: Immediately after change of the head position especially aphakic eyes demonstrated remarkable refractive shifts. The results of this study explain patients' complaint of visual changes during the daily course after intraocular silicone oil injection. Refractive alterations evoked by silicone oil stabilized a few minutes after change of the head position.

Adult↗

[Cataract surgery and anticoagulation--current status].

UNLABELLED: Patients on anticoagulation therapy run an increased risk for intraoperative bleeding, but withholding this rheologic therapy increases the danger of thromboembolic complications. Management of cataract patients on anticoagulation therapy is not standardized. In this multicenter survey, we ascertained perioperative management trends. METHODS: Questionnaires from 122 centers were received (81.3%), each performing an average of 1558 cataract surgeries/year (total: 172.880 surgeries in 1995). RESULTS: The majority of surgeons continued their surgical (73%) and anesthetic (75%) technique, continued aspirin (63%) and discontinued coumarine therapy (77%). The preferred kind of anesthesia was retro- (28%) or peribulbar (18%) followed by systemic and/or retrobulbar anesthesia (25%). 64% of surgeons changed their treatment to intravenous heparin, 36% stopped coumarine without supplement therapy, while 16% of these surgeons did not check for thromboplastine time. Those who continued cumarine therapy preferred a corneal approach (85%) with subconjunctival and topical anesthesia (51%), respectively. CONCLUSION: Anticoagulation therapy slightly influences anesthetic technique or the surgical approach chosen in these patients. Usually coumarine therapy was discontinued which implicates the possibility of life-threatening complications and mandates tight control of coagulation parameters. Ophthalmic surgeons who continued anticoagulation therapy preferred a corneal approach followed by phacoemulsification. The advantages of discontinuing anticoagulation therapy have to be weighed against potential risks.

Anticoagulants↗

Comparison of the induced astigmatism after temporal clear corneal tunnel incisions of different sizes.

A prospective, randomized study compared the surgically induced astigmatism after 3.5 mm, 4.0 mm, and 5.0 mm temporal corneal tunnel incisions over six months. We studied 60 eyes of 60 patients who had phacoemulsification through a two-step clear corneal tunnel incision and implantation of one of three posterior chamber intraocular lenses (IOLs). Patients were divided into three groups of 20 each: Group A, cartridge injection of a foldable plate-haptic silicone IOL through a 3.5 mm self-sealing incision; Group B, cartridge injection of a disc silicone IOL through a 4.0 mm self-sealing incision; Group C, 5.0 mm optic poly(methyl methacrylate) IOL through a 5.0 mm incision with one radial suture. Corneal topography data were obtained using a computerized videokeratographic analysis system preoperatively and one week and six months postoperatively. Vector analysis was performed to calculate the surgically induced astigmatism. After the first postoperative week, mean induced astigmatism was 0.63 diopters (D) (+/- 0.41) in Group A, 0.64 D (+/- 0.35) in Group B, and 0.91 D (+/- 0.77) in Group C. After six months, it was 0.37 D (+/- 0.14) in Group A, 0.56 D (+/- 0.34) in Group B, and 0.70 D (+/- 0.50) in Group C. Surgically induced astigmatism was significantly lower in Group A than in Group B (P < .05) and Group C (P < .005) after six months. Vector analysis demonstrated that temporal corneal tunnel incisions induced clinically minimal astigmatism over six months postoperatively depending on incision size.

Aged↗