Search PubMed⌕ Search

Biomedical subjects

B Conklin

Publications and source records attributed to B Conklin.

10 recordsLinked to original sources

Evaluation of thrombolysis in a porcine model of chronic deep venous thrombosis: an endovascular model.

PURPOSE: The advancement of catheter-based interventions for vascular recanalization has underscored the need for an experimental animal model of vascular thrombosis that can be used for the evaluation of interventional therapies. In this model, a porcine model of deep venous thrombosis with a novel endovascular technique was described, and the efficacy of thrombolytic therapy with urokinase was evaluated. METHODS: An endovascular device that consisted of a tapered polytetrafluoroethylene graft attached within a self-expanding nitinol stent was delivered to bilateral common iliac veins in 20 pigs. Venous thrombosis occurred as a result of flow stasis created by the intrastent stenosis. Catheter-directed pulse-spray thrombolysis with urokinase (250,000 units) and heparin (5000 IU) was performed on one limb while the contralateral limb received control saline solution. Thrombolysis was performed in 1 hour (n = 4), 8 hours (n = 4), 3 days (n = 4), 7 days (n = 4), and 14 days (n = 4) after the stent-graft deployment. Venography and intravascular ultrasound were used to evaluate the efficacy of thrombolysis. Light microscopy was used for histologic analysis of the thrombus. RESULTS: Complete thrombolysis was achieved in groups with deep vein thrombosis that were younger than 1 day. Angioplasty of the tapered stent-grafts in the completely thrombolysed iliac vein was successful in restoring venous flow. The efficacy of thrombolysis in 3-day, 7-day, and 14-day groups was 86% +/- 7%, 73% +/- 13%, and 42% +/- 23%, respectively. The thrombolytic efficacy was enhanced to 92% +/- 16% and 86% +/- 18% (P <.05) in 3-day and 7-day groups, respectively, when doses of the pulse-spray thrombolysis were doubled. Increased dosages of the thrombolytic agent, however, did not significantly enhance the thrombus dissolution in the 14-day group. CONCLUSION: The thrombolytic efficacy of urokinase correlated with the chronicity of deep venous thrombosis in our model. An increased dose of urokinase may be used to enhance the efficacy of thrombolysis in a 1-week-old thrombus.

Animals↗

Evaluation of thrombolysis and angioplasty in a porcine iliac artery thrombosis model: application of endovascular stent-graft-induced thrombosis.

PURPOSE: To develop a novel endovascular thrombosis model in the porcine iliac artery for the evaluation of thrombolysis and angioplasty. MATERIALS AND METHODS: A stent-inversion-graft (SIG) model combining either a 3-mm or 5-mm tapered expandable polytetrafluoroethylene (ePTFE) graft attached within a self-expandable, 10-mm nitinol stent was placed in the left common iliac artery via an ipsilateral common femoral artery approach in 24 pigs. When the iliac artery was thrombosed, urokinase (250,000 IU) plus heparin (1,000 units) were pulse sprayed via a contralateral femoral approach (n = 12). Saline pulse-spray was used as a control group (n = 12). Balloon angioplasty was performed to eliminate the stenotic tapered graft within the stent after successful thrombolysis. The efficacy of the thrombolysis was assessed with use of intravascular ultrasound (IVUS) and arteriogram. RESULTS: Both the 3-mm tapered and 5-mm tapered SIG models caused iliac artery occlusion in 22 +/- 5 and 41 +/- 9 minutes, respectively, after the deployment. Luminal patency was re-established successfully in all occluded arteries after urokinase infusion. Angioplasty was successful in eliminating the tapered stenosis and restoring the normal diameter in all iliac arteries treated with urokinase. Complete thrombolysis was achieved in both models treated with urokinase. CONCLUSION: This novel endovascular approach of inducing arterial thrombosis is simple to perform and reliably produces arterial thrombosis. The intraluminal stenosis is also amenable to angioplasty. This model is useful for the evaluation of antithrombotic treatment modality and adjunctive endovascular interventions.

Alloys↗

Absorption of antisense oligonucleotides in rat intestine: effect of chemistry and length.

An in situ single-pass perfusion model was used to assess the effect of chemical modification and length on permeability and absorption of various oligonucleotides in rat intestine. Phosphorothioate oligodeoxynucleotides (PS-ODN) were compared with oligoribonucleotides with 2'-methoxyethyl (MOE) or 2'-O-methyl (OMe) modifications. A 25-mer PS-OMe-modified oligonucleotide showed relatively poor permeability in this model, as did unmodified 20-mer PS-ODN (permeability coefficient [P(eff)] = 2-8 X 10(-6)cm/sec). Modifying some or all of the oligonucleotides with 2'-MOE groups on deoxyribose and 5'-methylation of the cytosines substantially increased intestinal permeability of oligonucleotides. Both partially and fully modified PS-MOE oligonucleotides showed a (2-4)-fold increase in permeability as compared with unmodified PS-ODN. The presence of a phosphodiester backbone in MOE-modified compounds led to further increases in intestinal permeability. PS-MOE composed of 6, 8, 10, 12, 14, 16, 18, 20, and 22 nucleotides were also examined. It was found that the permeability of these oligonucleotides increased linearly with decreasing length.

Animals↗

In vivo pharmacodynamic activities of two glycylcyclines (GAR-936 and WAY 152,288) against various gram-positive and gram-negative bacteria.

The in vivo pharmacodynamic activities of two glycylcyclines (GAR-936 and WAY 152,288) were assessed in an experimental murine thigh infection model in neutropenic mice. Mice were infected with one of several strains of Streptococcus pneumoniae, Staphylococcus aureus, Escherichia coli, or Klebsiella pneumoniae. Most infections were treated with a twice-daily dosing schedule, with administration of 0.75 to 192 mg of GAR-936 or WAY 152,288 per kg of body weight. A maximum-effect dose-response model was used to calculate the dose that produced a net bacteriostatic effect over 24 h of therapy. This dose was called the bacteriostatic dose. More extensive dosing studies were performed with S. pneumoniae 1199, E. coli ATCC 25922, and K. pneumoniae ATCC 43816, with doses being given as one, two, four, or eight equal doses over a period of 24 h. The dosing schedules were designed in order to minimize the interrelationship between the various pharmacokinetic and pharmacodynamic parameters studied. These parameters were time above 0.03 to 32 times the MIC, area under the concentration-time curve (AUC), and maximum concentration of drug in serum (C(max)). The bacteriostatic dose remained essentially the same, irrespective of the dosing frequency, for S. pneumoniae 1199 (0.3 to 0.9 mg/kg/day). For E. coli ATCC 25922 and K. pneumoniae ATCC 43816, however, more frequent dosing led to lower bacteriostatic doses. Pharmacokinetic studies demonstrated dose-dependent elimination half-lives of 1.05 to 2.34 and 1.65 to 3.36 h and serum protein bindings of 59 and 71% for GAR-936 and WAY 152,288, respectively. GAR-936 and WAY 152,288 were similarly effective against the microorganisms studied, with small differences in maximum effect and 50% effective dose. The glycylcyclines were also similarly effective against tetracycline-sensitive and tetracycline-resistant bacteria. Time above a certain factor (range, 0.5 to 4 times) of the MIC was a better predictor of in vivo efficacy than C(max) or AUC for most organism-drug combinations. The results demonstrate that in order to achieve 80% maximum efficacy, the concentration of unbound drug in serum should be maintained above the MIC for at least 50% of the time for GAR-936 and for at least 75% of the time for WAY 152,288. The results of these experiments will aid in the rational design of dose-finding studies for these glycylcyclines in humans.

Animals↗

A porcine model of carotid artery thrombosis for thrombolytic therapy and angioplasty: application of PTFE graft-induced stenosis.

PURPOSE: To develop a porcine carotid artery thrombosis model for the evaluation of thrombolytic therapy and adjunctive angioplasty procedures. METHODS: Bilateral carotid thrombosis was induced in 16 pigs using endothelial crush injury followed by external polytetrafluoroethylene (PTFE, 5 x 2 cm2) wrap placement to create segmental carotid stenosis. Light microscopy was used to examine thrombus composition. Selective carotid catheterization was performed via a femoral approach. Two hours following carotid artery occlusion, a urokinase (250,000 IU) and heparin (1000 U) solution was pulse-sprayed in 1 carotid artery while the contralateral vessel received the control saline vehicle. The efficacy of thrombolytic therapy was assessed using carotid arteriography and intravascular ultrasound. The feasibility and technical efficacy of balloon angioplasty within the carotid stenosis model were also evaluated. RESULTS: Carotid artery occlusion occurred in 30 +/- 6 minutes following endothelial injury plus PTFE wrap placement. Histological examination of carotid arteries showed endothelial irregularity with fibrin-rich and platelet-rich thrombus. Urokinase was effective in recanalizing all occluded arteries (100%), while the control saline vehicle showed no effective thrombolysis (p < 0.001). Angioplasty was successful in restoring normal diameter in all arteries (100%). CONCLUSIONS: This carotid artery thrombosis model, which incorporates intimal injury with segmental stenosis, is simple to create and reproducible. It provides not only a model for the evaluation of thrombolytic therapy but also a practical training tool for adjunctive endovascular interventions.

Angiography↗

An endovascular model of carotid stenosis for the evaluation of thrombolysis and angioplasty.

PURPOSE: To develop a porcine carotid artery thrombosis model using a novel stent-graft device to evaluate the efficacy of thrombolytic therapy and angioplasty procedures. METHODS: An endovascular device made from a tapered polytetrafluoroethylene graft inverted in a self-expanding nitinol stent was delivered to bilateral carotid arteries via a right femoral approach in 16 pigs. Carotid thrombotic occlusion ensued from flow stasis created by the intrastent stenosis. Via selective carotid catheterization from a femoral approach, urokinase (250,000 IU) was pulse-sprayed in one carotid artery while a control saline solution was infused in the contralateral vessel; delivery times were 1 hour, 8 hours, 3 days, or 6 days after carotid occlusion (4 animals per time period). After thrombolysis, balloon angioplasty was performed to maintain carotid patency. Arteriography and intravascular ultrasound were used to evaluate the efficacy of thrombolysis. Light microscopy was used for histological analysis of the thrombus. RESULTS: Carotid artery occlusion occurred in 15+/-8 minutes after stent-graft placement in all animals. Urokinase was effective in recanalizing all occluded arteries in the 1-hour, 4-hour, and 3-day groups (100%) but was effective in only 2 of 4 animals in the 6-day group (p < 0.05). Overall thrombolytic efficacy was 78%+/-7%. Control saline solution showed no thrombolytic effect (p < 0.001). Angioplasty successfully restored normal luminal diameter in all fully lysed arteries (100%). Histological analysis showed fibrin-predominant thrombus with a varying degree of platelet deposition. CONCLUSIONS: This endovascular approach, which creates a carotid stenosis using this novel stent-graft device, is reliable in producing carotid thrombosis. In our model, thrombolytic therapy was effective in restoring luminal patency, and the intraluminal stenosis is amenable to balloon angioplasty. The model is useful for the evaluation of antithrombotic therapy and adjunctive endovascular interventions.

Angioplasty, Balloon↗

Chemically modified oligonucleotides exhibit decreased immune stimulation in mice.

Phosphorothioate oligodeoxynucleotides produce splenomegaly and mononuclear cell infiltrates in multiple organs in mice after repeated i.v. administration. Several phosphorothioate oligodeoxynucleotides were studied to better understand the basis of immunostimulatory properties of these molecules in mice and to study the effects of chemically modified oligonucleotides. Chemical modifications examined included 5-methyl cytosine and 2'-methoxyethoxy substituents. Male mice (six per group) were treated with oligonucleotide concentrations of 0, 2, 10, or 50 mg/kg by i.v. injection every other day for 14 days. Immune stimulation was assessed 24 h after the last dose by measuring spleen weight, or histologic and immunohistochemical examination of liver and kidney. Immune stimulation was dose-dependent for the phosphorothioate oligodeoxynucleotides studied, but potency varied as a function of sequence. Results from this study reveal that there is a close correlation between the extent of splenomegaly and other evidence of immune stimulation, such as the severity of cell infiltrates in liver and kidney in mice. Immunohistochemical analysis indicated that cell infiltrates in liver and kidney were primarily mononuclear cells associated with increased expression of the endothelial-leukocyte cellular adhesion molecule intracellular adhesion molecule-1 and the cytokine interleukin-6. Immune stimulation was markedly decreased with oligonucleotides containing the 5-methyl cytosine and further decreased by 2'-methoxyethoxy modifications. Administration of these modified oligonucleotides to mice did not produce splenomegaly even at the 50-mg/kg dose, and only produced minimal cell infiltrates despite the presence of comparable or greater tissue oligonucleotide concentrations. Thus, chemical modifications appeared to increase the tolerability profile for these compounds that are representative of the second generation of antisense oligonucleotides.

Alanine Transaminase↗

Antisense oligonucleotide inhibition of hepatitis C virus (HCV) gene expression in livers of mice infected with an HCV-vaccinia virus recombinant.

Hepatitis C virus (HCV) is the major cause of non-A, non-B hepatitis worldwide. Current treatments are not curative for most infected individuals, and there is an urgent need for both novel therapeutic agents and small-animal models which can be used to evaluate candidate drugs. A small-animal model of HCV gene expression was developed with recombinant vaccinia virus vectors. VHCV-IRES (internal ribosome entry site) is a recombinant vaccinia viral vector containing the HCV 5' nontranslated region (5'-NTR) and a portion of the HCV core coding region fused to the firefly luciferase gene. Intraperitoneal injection of VHCV-IRES produced high levels of luciferase activity in the livers of BALB/c mice. Antisense oligonucleotides complementary to the HCV 5'-NTR and translation initiation codon regions were then evaluated for their effects on the expression of these target HCV sequences in BALB/c mice infected with the vaccinia virus vector. Treatment of VHCV-IRES-infected mice with 20-base phosphorothioate oligonucleotides complementary to the sequence surrounding the HCV initiation codon (nucleotides 330 to 349) specifically reduced luciferase expression in the livers in a dose-dependent manner. Inhibition of HCV reporter gene expression in this small-animal model suggests that antisense oligonucleotides may provide a novel therapy for treatment of chronic HCV infection.

Animals↗

Monaghan 225 ventilator use under hyperbaric conditions.

The Monaghan 225 ventilator was tested to ambient pressures of 6 atmospheres absolute (ATA) in a hyperbaric chamber. The ventilator would function with delivered tidal volume which was independent of ambient pressure. Ventilatory rate declined in an exponential fashion. At 6 ATA, the ventilatory rate was 45 percent of the preset rate at 1 ATA. By decreasing the circuit resistance and increasing the inspiratory flow rate, the 6 ATA rate could be increased to 72 percent of the 1 ATA value. The maximum minute ventilation of the ventilator at 1 ATA was approximately 48 L/min; at 6 ATA, its maximum was 18 L/min. Synchronized intermittent mandatory ventilation, assist/control, and PEEP functions were satisfactory at 6 ATA. While using 100 percent O2 to power the ventilator at 2.82 ATA, the oxygen leakage was 57.7 L/min (converted to 1 ATA pressure, 20 degrees C), of which 33.7 L/min was successfully scavenged using simple techniques. A minor modification was made to the ventilator, allowing it to be driven by compressed air while maintaining complete flexibility in setting the FIo2. The ventilator has proven stable and reliable in clinical use at ambient pressures up to 6 ATA.

Equipment Design↗