Search PubMed⌕ Search

Biomedical subjects

B Canaud

Publications and source records attributed to B Canaud.

At least 145 records · Page 8Linked to original sources

[Acute renal failure and hepatitis induced by clometacin].

Various types of allergic accidents have been reported with clometacin (Duperan), a synthetic analgesic introduced in France in 1971. The most prominent is hepatitis in elderly women, with hyperglobulinemia, eosinophilia, autoantibodies and giant multinucleated hepatocytes. The case presented herein concerns a 73-year-old woman who, on two separate occasions after the ingestion of clometacin at recommended dosages, developed at the same time typical acute hepatitis and non-oliguric acute renal failure. The second episode came soon after the medication was inadvertently reintroduced. Both hepatic and renal involvements were fully reversible. A renal biopsy showed predominant lesions of acute interstitial nephritis and tubulonecrosis. Three possible mechanisms are discussed: 1) sensitivity of the kidney to drugs because of preceding angiosclerosis, 2) impaired regulation of renal blood flow because of clometacin provoked decrease of prostaglandin synthesis, and 3) as in the case of nephrotoxicity due to other medications, allergic mechanisms.

Acute Kidney Injury↗

Permanent loss of ultrafiltration capacity of the peritoneum in long-term peritoneal dialysis: an epidemiological study.

Permanent loss of the ultrafiltration (UF) capacity of the peritoneum has been observed with an increasing frequency among our patients treated by long-term intermittent (IPD) and/or continuous ambulatory peritoneal dialysis (CAPD). The analysis of various characteristics of our PD population (patients age, dialysis techniques, peritoneal infection rate and treatment duration) indicates that the incidence of this complication increases exponentially with the duration of PD, the loss of UF capacity being observed after a shorter period in CAPD than in IPD. These observations suggest that long-term irrigation of the peritoneal cavity leads to a progressive deterioration of the peritoneum resulting in its altered permeability with loss of the ability to ultrafiltrate; the cause of this abnormality is as yet unknown.

Adult↗

[Kinetics of ultrafiltration in peritoneal dialysis with long dialysate dwell: an "in situ" study (author's transl)].

In order to measure in situ the kinetics of peritoneal ultrafiltration in peritoneal dialysis (PD) with long dialysate dwell, a colorimetric method using autologous hemoglobin as a marker added to the dialysis fluid was evaluated in 10 patients on PD for periods ranging from 2 weeks to 20 months. Four different dialysate formulae were successively tested in the same patient. The results expressed as normalised ultrafiltration coefficient (UFK, ml/min/1.73 m2 s.a.) showed a wide scatter among the patients. However, the dilution curves successively obtained with dialysis fluids of varying osmolar concentration in the same patient were very consistent with each other, indicating that UFK was a characteristic of the individual peritoneal membrane. The data presented suggest that UFK should be measured in each patient at initiation of PD in order to prescribe the dialysate formulae and the diffusion times fitting best his individual needs. On the other hand, repetitive measurements of UFK in the same subject would allow a useful analysis of the hydraulic permeability of the peritoneum by detecting any significant change in this parameter during long term PD.

Adult↗

Acidosis and nutritional status in hemodialyzed patients. French Study Group for Nutrition in Dialysis.

In a cross-sectional study of more than 30% of French dialysis patients (N = 7,123), we evaluated the relationships between predialysis plasma bicarbonate concentration and nutritional markers. Data including age, gender, cause of end-stage renal disease (ESRD), time on dialysis, body mass index (BMI), blood levels of midweek predialysis albumin, prealbumin, and bicarbonate were collected. Normalized protein catabolic rate (nPCR), dialysis adequacy parameters, and estimation of lean body mass (LBM) were computed from pre- and postbicarbonate-dialysis urea and creatinine levels according to the classical formulas of Garred. Average values (+/- 1 SD) were age 61 +/- 16 years, BMI 23.3 +/- 4.6 kg/m2, dialysis time 12.4 +/- 2.7 h/week, HCO3 22.8 +/- 3.5 mmol/L, albumin 38.7 +/- 5.3 g/L, prealbumin 340 +/- 90 mg/L, Kt/V 1.36 +/- 0.36, nPCR 1.13 +/- 0.32 g/kg BW/day, and LBM 0.86 +/- 0.21% of ideal LBM. A highly significant negative correlation was observed between predialysis bicarbonate levels (within a range of 16-30 mmol/L, 95% of this population) and nPCR confirmed by analysis of variance using bicarbonate classes (p < 0.0001). Bicarbonate was also negatively correlated with albumin, prealbumin, BMI, and LBM. No relationship was noted between bicarbonate and Kt/V despite a positive correlation between Kt/V and nPCR. It is likely that a persistent acidosis observed despite standard bicarbonate dialysis was caused by a high dietary protein intake which results in an increased acid load, but also overcomes the usual catabolic effects of acidosis.

Acidosis↗

Protein catabolic rate determination from a single measurement of dialyzed urea.

Protein catabolic rate (PCR, in g protein/kg/day) for anuric patients can be accurately determined without blood sampling by equating urea generation over 7 days to the urea dialyzed in the three dialyses of this period as measured by partial dialysate collection (PDC) or with a urea monitor. The feasibility of determining the week's dialyzed urea from measurement of urea dialyzed in a single session, obviating the need to monitor three consecutive dialyses, was examined in a steady-state simulation of 540 anuric patients spanning the full range of dialysis parameters. It was found that the first, midweek, and last dialyses account for nearly constant fractions (37.9, 32.1, and 30.0%, respectively) of the week's urea removal, leading to equations of the form: PCR = CU/BW + 0.17 where U is the grams of urea dialyzed in the first, midweek, or final dialysis of the week, C = 2.45, 2.89, or 3.10, respectively, and BW is the patient's dry weight in kilograms. These equations were tested on 1312 weeks of PDC data gathered in 42 dialysis patients. Using the midweek U resulted in a mean absolute error in PCR < 0.05 g/kg/day when compared to PCR determined using all three of the week's U values.

Aged↗

Data acquisition system for dialysis machines. A model for membrane hydraulic permeability.

Membrane permeability is a key determinant of dialyzer performance; in vivo, membrane hydraulic permeability is affected by the formation of a protein cake on its surface, reducing ultrafiltration and convective fluxes. The purpose of this work was to evaluate the real hydraulic permeability of high flux polysulfone membrane under conditions of hemodiafiltration, and to consequently develop a mathematical model to estimate ultrafiltration Kuf and protein adsorption Kc coefficients. The DIB08 data acquisition system adapted to the Fresenius 2008E dialysis machine (Fresenius, Bad Homburg, Germany) allowed the recording of useful information for dialysis quantification, which was then processed by a bedside computer. The system was able to evaluate Kuf(t) profile, by calculation from the transmembrane pressure over time (TMP(t)) and ultrafiltration rate (Quf):Kuf (t) = Quf/TMP (t). Subsequent modeling of Kuf involved the determination of two key parameters: Kufhd (dialyzer permeability during diffusion only) (in mL/h/mmHg), and Kc (protein adsorption coefficient) (in mL/h/mmHg2). The model chosen was the following: Kuf (t) = Kuf0 x (1 - (Kc/Kuf0) x In(t + 1)) where Kuf0 represents the initial Kuf obtained at the beginning of the session. Thirty-one sessions were evaluated by real kinetic analysis, from which the mathematical model was derived. It included 27 postdilutional on-line hemodiafiltration and four hemodialysis sessions performed in four patients with nonreused HF80s dialyzers. For the analysis, three subgroups were defined: Group 1, first session of the week (Monday or Tuesday); Group 2, second session of the week (Wednesday or Thursday); and Group 3, third session of the week (Friday or Saturday). Results of Kuf and Kc obtained by real kinetic analysis are presented. The midweek session was associated with a higher membrane hydraulic permeability, most likely relative to lesser ultrafiltration rates and an associated relative decrease in membrane protein coating, represented by Kc. The described data acquisition system allowed the assessment of real time membrane hydraulic permeability and the subsequent development of a mathematical model to estimate this fundamental parameter as it functions to hemodialyzer performance.

Adult↗

On-line dialysis quantification in acutely ill patients: preliminary clinical experience with a multipurpose urea sensor monitoring device.

Direct dialysis quantification offers several advantages compared with conventional blood urea kinetic modeling, and monitoring urea concentration in the effluent dialysate with an on-line urea sensor is a practical approach. Such a monitoring device seems desirable in the short-term dialysis setting to optimize and personalize both renal replacement therapy and nutritional support of acutely ill patients. We designed a urea monitoring device consisting of a urea sensor, a multichannel hydraulic circuit, and a PC microcomputer. The sensor determines urea from catalysis of its hydrolysis by urease in liquid solution during neutral conditions. Hydrolysis of urea produces NH4+, and creates an electrical potential difference between two electrodes. Each concentration determination of urea is the average value of 10 measurements; samples are diverted and measured every 7 min. Laboratory calibration of the urea sensor has demonstrated linearity over the range 2-35 mmol/L. Urea monitoring was performed throughout the treatment course, either on the effluent dialysate or ultrafiltrate in seven acutely ill patients treated by either hemofiltration (n=5) or hemodiafiltration (n=2). The slope of the concentration of urea in the effluent over time was used to calculate an index of the dialysis dose delivered (Kt/V), urea mass removal, and protein catabolic rate. In addition, samples of the effluent were drawn every 21 min, and sent to the central laboratory for measurement of urea concentrations using an autoanalyzer. Kt/V values also were calculated with Garred's equation using pre and post session concentrations of urea in blood. Concentrations of urea in the effluent determined by the urea sensor were found to be very close to those obtained from the central laboratory over a wide range of values (3 to 42 mmol/L). In addition, Kt/V values for both hemofiltration and hemodiafiltration, when calculated with concentrations of urea in the effluent obtained by the urea sensor, did not significantly differ from Kt/V values obtained from the laboratory concentrations of urea in the effluent. On-line urea sensor monitoring of the effluent suppresses the cumbersome task of total effluent collection, and the complexity of urea kinetic analysis. The multipurpose prototype described here represents a new, simple, and direct assessment of dialysis dose and protein nutritional status of acutely ill patients, and is suitable for various modalities.

Acute Kidney Injury↗

The role of mineral metabolism and inflammation on dialysis vascular access failure.

Thrombosis of arteriovenous fistula (AVF) is the leading cause of vascular access (VA) loss usually due to silent stenosis. Therefore, assessment of relevant risk factors of VA monitoring may provide insight into potential therapeutic targets for stenosis and thrombosis. The aim of this study was to evaluate the influence of cardiovascular risk factors (including inflammation and mineral metabolism dysfunctions) on the failure of internal AVF in HD patients. 128 HD patients with internal AVF were included in the study and followed up for two years. At baseline, VA morphology and function were followed by Doppler ultrasonography and serum albumin, prealbumine, C-reactive protein, orosomucoid, calcium, phosphorus, parathyroid hormone, bone-type alkaline phosphatase, osteoprotegerin and receptor activator of nuclear factor ê ê B ligand were measured. At baseline, 50 stenoses were detected but none of them required any intervention. Age and biological parameters did not significantly differ between patients with or without VA stenosis. Over the two year- follow up, VA thrombosis occurred in 19 patients. Preexisting stenosis of VA was present in 9/19 patients (47.3% of cases) (chi-square = 3.708, p = 0.0538). Despite the low rate of events, phosphorus [1.75 (0.95-2.77) vs 1.42 (0.47-3.22) mmol/L, p = 0.0416], Calcium x Phosphorus product [4.00 (2.00-5.90) vs 3.40 (1.10-6.80) mmol(2)/L(2), p = 0.0676] and parathyroid hormone [165.00 (1.00-944.00) vs 79.50 (1.00-846.60) ng/L, p = 0.0814) levels were higher in the 19 thrombotic patients whereas all other biological parameters did not significantly differ. These results, which confirm that VA thrombosis occurs more frequently upon preexisting stenosis, also demonstrate that mineral metabolism disorders, compared to inflammation, may contribute to VA dysfunction leading to thrombosis.

Adult↗

Reuse of "highly permeable" dialyzers with peroxyacetic acid as sole cleansing and disinfecting agent.

In the past few years, dialyzer reuse has gained increased clinical acceptance. This has been due both to the availability of automated reconditioning machines and powerful chemical cleaning and disinfecting agents. In this study the authors evaluated the effectiveness of a newly available peroxyacetic acid solution (PAS) (Dialox) as the dual cleaning and disinfecting agent in the reuse of highly permeable dialyzers. An in vivo study was conducted with ten patients already involved in our center's reuse program using the Renatron reprocessing machine and PAS at various dilutions. One hundred forty dialyzers of three different brands and membrane types (HF80 used for hemodiafiltration [HDF], Filtral 16 used for hemodialysis [HD], and FH88 used for hemofiltration [HF]) were employed for a total of 1182 treatments, giving an average 8.4 uses per module. Significantly more uses were obtained with the HF80 and Filtral 16 dialyzers (9.7 and 9.4, respectively) than for the FH88 modules used by the HF patients (6.7 uses per module). Compromised cleaning by backfiltration due to the lack of a second dialysate port on the FH88 may be a possible explanation. Greater membrane plugging due to higher ultrafiltration rates in HF may be another factor. Patient variability was found to be another factor in dialyzer reuse. The cleaning effectiveness of various dilutions of PAS was also tested in this study. The number of uses achieved was not found to vary significantly with PAS strength; however, a greater frequency of second or third reprocessing was required with more dilute cleaning solution. The authors found the dilution achieved on the Renatron reprocessing machine using the currently marketed PAS concentrate to be the most cost effective.

Disinfection↗