Search PubMed⌕ Search

Biomedical subjects

Anton Moritz

Publications and source records attributed to Anton Moritz.

At least 55 records · Page 3Linked to original sources

The Na+/H+ exchange inhibitor HOE642 prevents stress-induced epithelial barrier dysfunction.

Recently, evidence has been obtained that the Na+/H+ exchange (NHE) inhibitor HOE642 may stabilize endothelial and epithelial barrier function in vivo. However, the underlying mechanisms are not known. Therefore, we studied the influence of HOE642 on the barrier function of the epithelial cell line CaCo2. The phorbolester phorbol 12-myristate 13-acetate (PMA) was used to induce hyperpermeability of the epithelial layer which was indirectly determined by measuring the transepithelial electrical resistance (TER). Confocal laser scan microscopy (LSM) served to analyze the intracellular localization of adherens and tight junction molecules. In five independent experiments we found that HOE642 increased TER in non-treated CaCo2 cells (control: 350 +/- 28 Omega/cm2; HOE642: 444 +/- 53 Omega/cm2) and prevented PMA-induced barrier dysfunction (PMA: 33 +/- 12 Omega/cm2; PMA plus HOE642: 496 +/- 47 Omega/cm2). LSM showed that HOE642 prevented the PMA-induced disassociation of the zonula adherens molecule beta-catenin from the cell membrane and the decreased expression of the zonula occludens molecule ZO-1. From our data we conclude that HOE642 may prevent stress-induced epithelial dysfunction by stabilization of cell membrane-associated junction molecules.

Anti-Arrhythmia Agents↗

Urgent thoracic aortal dissection and aneurysm: treatment with stent-graft implantation in an angiographic suite.

The aim of this study was to evaluate the feasibility of endoluminal stent-graft placement in an angiographic suite for the treatment of emergent type-B aortic dissections and ruptured thoracic aortal aneurysms. Twenty-six patients with either urgent type-B dissection (n=8) or aneurysms (n=18) of the descending thoracic aorta were chosen for stent-graft implantation. All patients received a multidetector-row CT angiography of the whole aorta and pelvic arteries prior to stent-graft implantation. All procedures were performed in a fully equipped digital subtraction angiography (DSA) suite under general anesthesia. In 20 patients Talent LPS tube grafts and in 4 patients an Excluder graft were used. Access was achieved via surgical cut-down in the left (n=7) or right (n=19) groin. Sealing was successful in 24 patients. The proximal covered portion of the stent graft was placed across the left subclavian artery in 2 patients. Procedural success was achieved in 23 of 24 patients. One patient required a second stent-graft placement before the aneurysm was sealed. One patient with an acute perforation of the descending aorta died due to cardiac failure prior to stent-graft implantation. In 1 patient stent-graft delivery failed due to severe calcification of both common iliac arteries. Endoluminal treatment of both urgent type-B aortic dissections and thoracic aortal aneurysms with stent graft is an attractive alternative treatment to surgical repair. The placement of stent grafts in an angiographic suite is a safe and feasible method with good clinical effectiveness and, so far, good clinical outcome.

Acute Disease↗

Awake coronary artery bypass grafting: utopia or reality?

BACKGROUND: Off-pump coronary artery bypass grafting (OPCAB) was implemented to reduce trauma during surgical coronary revascularization. High thoracic epidural anesthesia further reduced intraoperative stress and postoperative pain. This technique also supports awake coronary artery bypass (ACAB), completely avoiding the drawbacks of mechanical ventilation and general anesthesia in high-risk patients. We compared our first results of the ACAB procedure with the conventional OPCAB operation. METHODS: Thirty-five patients underwent ACAB (group A) with left internal mammary artery to left anterior descending coronary artery grafting using a partial lower ministernotomy (n = 25) or double bypass grafting (n = 9) and even triple vessel coronary artery revascularization (n = 1) through complete median sternotomy. Thirty-four patients (group B), matched for age, sex, and comorbidity with group A, underwent either partial lower ministernotomy (n = 24) or OPCAB by complete sternotomy (n = 10). We recorded clinical outcomes and postoperative visual analog scale pain scores. RESULTS: In group A, 32 patients remained awake throughout the entire procedure. Three patients required secondary intubation because of incomplete analgesia (n = 1) or pneumothorax (n = 2). Patients in group A had a recovery room stay of 6.0 +/- 3.2 hours. In group B, mechanical ventilation was implemented for 4.8 +/- 3.1 hours and intensive care unit stay lasted 12 +/- 6.8 hours. Group A had no in-hospital deaths, compared with 1 death in the conventional OPCAB group. Each group had 1 patient with graft stenosis detected on the predischarge angiogram. Early postoperative pain was significantly less in group A than in group B (visual analog scale of 32 +/- 8 compared with 58 +/- 11, p < 0.0001). CONCLUSIONS: The present data demonstrate the feasibility and safety of surgical coronary revascularization without general anesthesia. Continuation of thoracic epidural analgesia provides better pain control and faster mobilization after such procedures. Surprisingly, the ACAB procedure was well accepted by the patients.

Anesthesia, Epidural↗

Emergent endovascular stent grafting for perforated acute type B dissections and ruptured thoracic aortic aneurysms.

BACKGROUND: The purpose of our study was to demonstrate the effectiveness of endovascular stent grafts in the treatment of acutely ruptured thoracic aortic aneurysms and type B dissections as an alternative to the conventional surgical approach in an emergency setting. METHODS: From January 2001 to October 2001, we deployed 11 emergent endovascular stent grafts into the thoracic aorta. We treated seven ruptured aortic aneurysms and four acutely perforated type B dissections. Aortic rupture was confirmed preoperatively by spiral computed tomography. In all cases, hemothorax was present. The average interval from onset of symptoms to treatment was 28.5 hours. We used nine Talent and two Excluder stent grafts. RESULTS: Deployment of the stent grafts was successful in nine cases. There were two cases of access failure due to small caliber of iliac arteries, and 1 of these patients died shortly after the procedure was abandoned, At 12 months of follow-up, there were no cases of paraplegia, stent migration, or endoleaks. There was, however, one temporary renal failure, and 2 patients required mechanical ventilation for more than 48 hours. CONCLUSIONS: Our experiences with emergency endovascular stent grafting show that the procedure is technically feasible, with less morbidity and mortality than conventional open surgery, in high-risk patients.

Adult↗

Surgical versus endovascular treatment of acute thoracic aortic rupture: a single-center experience.

BACKGROUND: Surgical management of acute thoracic aortic ruptures is controversial, especially in patients with preexisting comorbidities; associated mortality and paraplegia rates remain high. It was our objective to evaluate whether treating these patients acutely with endovascular stent grafts would improve their outcome. METHODS: From November 1999 to February 2002 a total of 54 patients, age 28 to 83 years, were admitted to our institution with an acute rupture of the thoracic aorta (24 ruptured aneurysms, 14 perforated type B dissections, 16 traumatic ruptures). Twenty-eight patients were managed surgically using cardiopulmonary bypass (group 1), and 26 patients were treated acutely with an endovascular stent graft (group 2). The resuscitation protocol and interval from onset of symptoms to treatment was comparable in both groups. Medical records were reviewed for prehospitalization and emergency department data, operative findings, and outcomes. RESULTS: There were 5 of 28 deaths (17.8%) in the surgical group and 1 of 26 deaths (3.8%) in the endovascular group. In the surgical group 1 of 28 patients (3.6%) exhibited paraplegia; there were no cases of paraplegia in the endovascular group. There were 4 of 28 cases (14.3%) of renal failure in group 1 and 1 of 26 (3.8%) in group 2. In group 1, 8 patients (28.6%) required mechanical ventilation for more than 48 hours; there were 2 of 26 patients (7.7%) in group 2 with this ventilatory requirement. Three patients required a repeat thoracotomy for hemorrhage in the surgical group. There were two access failures in the endovascular group. CONCLUSIONS: In the treatment of acute ruptures of the thoracic aorta, the immediate outcome of patients treated with endovascular stent grafts appears to be better than with management by conventional surgical repair.

Adult↗

Totally endoscopic atrial septal repair in adults with computer-enhanced telemanipulation.

OBJECTIVE: Standard surgical closure of an atrial septal defect via sternotomy is a safe and effective procedure with low morbidity and mortality. Considering that young female patients are frequently operated on for atrial septal defects, a minimally invasive procedure avoiding sternotomy is convincingly desirable and led to the approach through a right anterolateral minithoracotomy. The recent clinical introduction of robotically assisted surgery further reduced skin incisions and enabled totally endoscopic procedures through ports. This article reports on a first series of atrial septal defect closures of which the first case was operated on August 24, 1999, in a totally endoscopic closed chest technique using a computer-enhanced telemanipulation system. METHODS: We performed totally endoscopic atrial septal repair using the da Vinci surgical system (Intuitive Surgical, Mountain View, Calif) in 10 consecutive adult patients. Median age was 45.5 +/- 10.0 years, and preoperative New York Heart Association functional class was 1.8 +/- 0.1. Left ventricular ejection fraction was normal in all patients and mean pulmonary artery pressure amounted to 35 +/- 7 mm Hg. Shunt volume ranged from 24% to 70%. All patients displayed a fossa ovalis type of atrial septal defect; 2 of them multiperforated. RESULTS: Neither intraoperative nor postoperative complications occurred. Two patients had to be converted to minithoracotomy due to endoaortic balloon clamp failure. Length of operation was 262 +/- 37 minutes, and cardiopulmonary bypass time was 161 +/- 26 minutes. Intraoperative transesophageal echocardiography certified complete closure of the atrial septal defect in all patients. The totally endoscopic computer-enhanced technique yielded excellent cosmetic results. CONCLUSION: Totally endoscopic atrial septal repair is a feasible and safe procedure with good clinical results and excellent cosmetic outcomes. It may be considered as perfect adjunct to interventional treatment options. Further studies with larger cohorts and randomized trials are necessary to document potential benefits. Evolution in robotic technology and refinement of procedural flow may shorten procedural time and decrease costs.

Adult↗

The clamshell approach for the treatment of extensive thoracic aortic disease.

OBJECTIVE: Management of extensive thoracic aortic disease may present an immense technical challenge. The choice of surgical access and subsequent exposure determines whether a single-stage or a 2-stage approach can be adopted. METHODS: Fifteen patients with extensive thoracic aortic disease underwent resection of the ascending aorta, the aortic arch, and varying segments of the descending aorta. Four patients had concomitant coronary artery bypass grafting and 3 patients had aortic valve reconstruction. All patients were treated with a single-stage approach via a bilateral anterior thoracosternotomy (clamshell incision). RESULTS: There was 1 hospital death (6.6%). Two patients required reoperation for bleeding (13.3%). Two patients needed mechanical ventilation for more than 48 hours. Three patients suffered a stroke (20%). Two patients (13.3%) had transient neurologic dysfunction. None of the patients had renal failure. There were no wound infections in this group. CONCLUSION: The single-stage approach, via a clamshell incision, is a safe and effective procedure for patients who require treatment of extensive thoracic aortic disease and concomitant cardiac lesions.

Aged↗

Magnetic vascular coupling for distal anastomosis in coronary artery bypass grafting: a multicenter trial.

OBJECTIVE: The hand-sewn anastomosis is the "gold standard" for performing coronary artery bypass grafts. However, performing a hand-sewn anastomosis is more demanding and time-consuming when used in less invasive approaches such as small access, totally endoscopic or beating heart surgery. In conjunction with attempts to reduce the surgical trauma of coronary artery bypass grafts by using these less invasive approaches, alternative methods for constructing distal anastomoses should be explored. These data report on predischarge angiographic findings and 30-day clinical follow up of patients who have received a new distal anastomotic device. METHODS: In a multicenter trial, 32 patients (mean age: 65 +/- 9 years; 85% men) requiring multivessel coronary artery bypass surgery had 1 of the anastomoses performed using a novel anastomotic technology. The Magnetic Vascular Positioner System was used in 1 of the bypass grafts and the other bypasses were completed by conventional hand-sewn technique. The Magnetic Vascular Positioner System consists of 4 magnetic, gold-plated implants and 2 delivery devices that facilitate the creation of a functional end-to-side anastomosis. A predischarge angiogram was performed to evaluate graft patency. RESULTS: There were no device-related major adverse events. The application of the Magnetic Vascular Positioner device was successful in 32 of 41 cases (78%). Nine patients were intended for treatment but did not receive the Magnetic Vascular Positioner System. In 5 of the cases the coronary artery was too small; 1 case had a posterior wall plaque in the target artery; and 3 patients had a nonhemostatic anastomosis after coupling of the port and were subsequently converted to hand-sewn anastomoses. The median total Magnetic Vascular Positioner anastomotic time was 137 seconds with a range from 65 to 370 seconds. Overall patency rate of the Magnetic Vascular Positioner anastomosis was 93.5% versus 91.7% (P = not significant) in hand-sewn grafts. One patient (3.1%) died due to low cardiac output but had patent grafts at autopsy. One myocardial infarction (3.1%) occurred the day after a percutaneous transluminal coronary angioplasty of a hand-sewn graft. One prolonged mechanical ventilation (3.1%) was required because of pneumonia and adult respiratory distress syndrome. CONCLUSIONS: Magnetic vascular coupling in coronary surgery is safe and effective and has acceptable early patency rates. This new technique may facilitate beating heart and minimally invasive coronary artery bypass grafts.

Adult↗

Cariporide (HOE642) limits S-100B release during cardiac surgery.

Cardiac surgery with cardiopulmonary bypass (CPB) results in transient cerebral swelling in most patients. Cognitive decline occurs in 24-57% of patients and 2-5% experience stroke. Serum levels of S-100B, a potential marker of increased blood-brain barrier permeability, increase during and early after surgery. The authors studied the effects of the novel Na /H exchange inhibitor cariporide (HOE642) on postoperative serum levels of S-100B and neuron-specific enolase (NSE) in 53 patients at high risk undergoing coronary artery bypass grafting. Patients were randomly assigned to one of four groups: I, placebo; II, 20 mg cariporide; III, 80 mg cariporide; IV, 120 mg cariporide). In addition, the leukocyte activation marker myeloperoxidase (MPO) and malondialdehyde (MDA), a marker for lipid peroxidation, were evaluated by enzyme-linked immunoassay. Postoperatively, five patients experienced transient ischemic attack or stroke. S-100B levels increased from 0.43 microg/l +/- 0.33 before operation to 2.27 microg/l +/- 0.69 1 hour after surgery in the placebo group. Preoperative S-100B levels in the HOE642 groups did not differ from the placebo group whereas, 1 hour after surgery, levels were significantly lower in groups II, III, and IV (1.63 microg/l +/- 0.2, 1.27 microg/l +/- 0.27, and 0.90 microg/l +/- 0.21, respectively). NSE, MPO, and MDA serum levels did not differ among groups. These findings may stimulate larger clinical studies to examine the effects of HOE642 on cerebral swelling and neurologic/cognitive outcome of cardiac surgery with CPB.

Aged↗

Multi-detector row CT versus coronary angiography: preoperative evaluation before totally endoscopic coronary artery bypass grafting.

PURPOSE: To assess multi-detector row spiral computed tomography (CT) for preoperative evaluation of patients undergoing totally endoscopic coronary artery bypass grafting and to correlate the data with coronary angiographic and intraoperative findings. MATERIALS AND METHODS: Thirty-six patients preoperatively underwent multi-detector row CT (4 x 1-mm collimation, pitch of 1.5, 500-msec rotation time, retrospective electrocardiographic gating, 1.25-mm effective section thickness) and coronary angiography. Assessment criteria for both techniques were visibility and cardiac course of coronary arteries, localization and degree of stenoses, composition of atherosclerotic plaques, and vascular diameter at anastomosis site. Site for distal bypass anastomosis was recommended. Results at multi-detector row CT were calculated relative to results at coronary angiography and surgery. RESULTS: Multi-detector row CT properly displayed 79.4% (154 of 194) of all surgical relevant coronary segments and 80.4% (434 of 540) of all coronary segments. For coronary angiography, ratios of 88.7% (172 of 194) and 94.6% (511 of 540), respectively, were observed. For detection of calcified plaques, multi-detector row CT results exceeded those at coronary angiography by a difference of 17% (18 of 18 [100%] compared with 15 of 18 [83%]). Hemodynamically relevant stenoses were identified with multi-detector row CT in 76% (42 of 55) of cases. Bridging of coronary segments through either myocardium (four of five) or epicardial fat (two of three) was better identified at multi-detector row CT than it was at coronary angiography (one of five compared with zero of three, respectively). At multi-detector row CT, 76% (28 of 37) of all distal bypass touchdown segments were identified, but at coronary angiography, only 70% (26 of 37) were identified. CONCLUSION: Multi-detector row CT provides extended information about coronary target site and therefore should be regarded as an ideal additive planning tool for complex minimally invasive procedures such as totally endoscopic coronary artery bypass grafting or minimally invasive direct coronary artery bypass grafting.

Adult↗

Minimally invasive versus conventional aortic valve replacement: a prospective randomized trial.

BACKGROUND AND AIM OF THE STUDY: A prospective randomized study was performed to compare conventional with minimally invasive aortic valve replacement (AVR). METHODS: Forty consecutive patients scheduled for elective aortic valve surgery were prospectively randomized either to the conventional group (group A, complete median sternotomy) or minimally invasive group (group B, partial upper sternotomy). Intraoperative and postoperative clinical data, and markers of myocardial and cerebral protection were determined. Neuropsychological tests were carried out to quantify psychological disorders. RESULTS: Operative time and cardiopulmonary bypass time were slightly longer in group B, but not significantly so. No significant inter-group differences were found for postoperative pain scores and respiratory function. Chest tube drainage was significantly less in group B (495 +/- 165 versus 240 +/- 69 ml, p = 0.008). Creatine kinase (CK), CK-MB and troponin T levels were similar in both groups. Neither S-100B protein nor neuron-specific enolase levels differed significantly between groups at all sampling times. There were no strokes in the entire cohort. None of the neuropsychological tests yielded significant inter-group differences between conventional and minimally invasive surgery. CONCLUSION: The safety and reliability of AVR via a partial upper sternotomy is reported. Minimally invasive AVR can be performed with only slightly longer operative times, good cosmetic results and significantly less blood loss. A limited surgical access affected neither the patients' neurological outcome nor the efficacy of myocardial protection.

Aortic Valve Insufficiency↗

Impact of left atrial size reduction on chronic atrial fibrillation in mitral valve surgery.

BACKGROUND AND AIM OF THE STUDY: Left atrial enlargement is a risk factor for the development of atrial fibrillation (AF). Large atrial size increases thromboembolic risk and reduces the success rate of cardioversion. The study aim was to evaluate if left atrial size reduction affects cardiac rhythm in patients with chronic AF undergoing mitral valve surgery. METHODS: Twenty-seven patients were analyzed prospectively. The left atrial incision was extended to the left inferior pulmonary vein. Left atrial size reduction was achieved by closure of the left atrial appendage from inside with a double running suture. The same suture plicated the left lateral atrial wall to the roof of the left pulmonary vein inflow and the inferior atrial wall. The atrial septum was plicated by placing stitches of the closing suture line across the fossa ovalis. Rhythm, neurological complications, cardioversion, anticoagulation and anti-arrhythmic medication were evaluated at one year postoperatively and at recent follow up (mean 40 +/- 15 months). RESULTS: At discharge, five patients (19%) were in sinus rhythm (SR). At one year postoperatively, SR was restored in 17 patients (63%), but five (19%) reported episodes of arrhythmia and AF persisted in 10 (37%). At recent follow up, four patients had died and three were lost to follow up. Among 20 patients examined, 13 (65%) had SR but six reported episodes of arrhythmia and AF persisted in seven (35%). LA diameter was significantly reduced, from 60.2 +/- 9.8 mm preoperatively to 44.5 +/- 7.0 mm at one year after surgery. CONCLUSION: The addition of left atrial size reduction to mitral valve surgery is technically simple, and was effective in 63% of patients with chronic AF, restoring predominant SR. In order to influence pathogenetic factors other than size, additional ablative steps may further increase the SR conversion rate. Size reduction may also improve the outcome of other ablative approaches.

Adult↗

Internal cardioversion for treatment of postoperative atrial fibrillation.

Atrial fibrillation (AF) is the most common dysrhythmia following open heart surgery with or without cardiopulmonary bypass. In previous studies, the AF incidence varied between 25.0% and 60.0% of all patients. The conventional treatment of postoperative AF periods consists of antiarrhythmic medication, most frequently calcium channel antagonists, beta-adrenergic blockers, or amiodarone. If the pharmacological treatment is ineffective or leads to further impairment of hemodynamics, external electrical cardioversion under general anesthesia and simultaneous transesophageal echocardiography is performed. Systemic heparinization is recommended to prevent neurological events related to AF. In 1995, a new method for internal electrical cardioversion using epicardial wire electrodes with low shock energies was developed in a canine model. Since June 1997, this device for internal cardioversion that consisted of two multifilament stainless steel wires has been available clinically (TADpole followed by Syncrus heart wires, Guidant Corporation C and VS, Cupertino, California, USA). The safety and efficacy of this innovative strategy for treatment of postoperative AF has been investigated in two pilot studies. These studies demonstrated a success rate of internal cardioversion up to 92.9% with optimized pre-shock treatment that leads to a significant shortening of AF periods, with the expectation of reduction in hospital length of stay.

Age Factors↗

Graded reoxygenation limits lipid peroxidation during surgical reperfusion.

BACKGROUND: Most cardiac operations with cardiopulmonary bypass (CPB) are conducted with high oxygen partial pressure. The hyperoxic reoxygenation of the ischemic heart induced by aortic declamping may be an important component of cardiac reperfusion injury. The present clinical study assessed the preventive effect of graded reoxygenation on lipid peroxidation. Malondialdehyde (MDA) levels reflect lipid peroxidation, and therefore can be used to quantify reoxygenation damage. MATERIAL/METHODS: 19 patients with coronary artery disease were enrolled consecutively and divided into two groups. In Group I, graded reoxygenation was initiated 1 min before, and continued for 9 min after aortic declamping (paO2: 50-70 mmHg, n=10). Patients undergoing conventional hyperoxic reoxygenation (paO2: >250 mmHg) on CPB (Group II, n=9) served as controls. Blood was collected before commencement of CPB, 2 min before release of the aortic crossclamp, 1 min and 10 min after release of the aortic crossclamp, and 3 hours after CPB. RESULTS: MDA levels [KM/l] did not differ between groups before CPB, but 1 min after aortic declamping MDA increased significantly more in group II (11.02 +/- 1.05; p=0.04) as compared to group I (8.16 +/- 0.74). There was no difference between groups late after reperfusion. CONCLUSIONS: Hyperoxic reoxygenation by release of the aortic crossclamp is associated with increased MDA levels immediately after aortic declamping. Graded normoxic reoxygenation therefore limits lipid peroxidation in the early reperfusion period.

Aged↗

Emergent endovascular interventions for contained rupture of thoracic aortic aneurysms.

BACKGROUND: The purpose of our study was to assess in an emergency setting the feasibility of endovascular stent graft treatment of contained ruptures of thoracic aortic aneurysms. METHODS: Seven patients with contained ruptures of thoracic aortic aneurysms from a series of 54 endovascular interventions were treated by the deployment of an aortic stent graft. In all cases, hemothorax was present. Acute deployment was performed with the patient under general anesthesia, and access was gained via the common femoral or iliac arteries. After a follow-up o f 12 months, the patients were evaluated by computed tomography. RESULTS: One patient died perioperatively. The procedure was technically successful in 5 patients. Perioperatively and at follow-up, there were no cases of paraplegia, stent graft migration, or endoleaks. There were, however, 2 cases of access failure, 1 case of temporary renal failure, and 2 patients who required prolonged mechanical ventilation. CONCLUSION: The acute treatment of contained ruptures of thoracic aortic aneurysms is feasible. This form of treatment seems to be a promising option in the treatment of these high-risk patients.

Aged↗

Ultrafast computed tomography for quality control of automated proximal anastomoses.

BACKGROUND: The Symmetry aortic connector uses a nitinol implant to create proximal anastomoses with saphenous vein grafts. Multiple detector-row cardiac computed tomography (MDCT) is used as a noninvasive method of quality control at our institution. METHODS: In 50 elective coronary artery bypass grafting patients who participated in a randomized trial comparing automated with conventionally hand-sewn proximal anastomoses, MDC T was performed on postoperative day 5. Fifty-three automated Symmetry anastomoses were created in 34 patients (group 1). Twenty-five conventionally hand-sewn anastomoses created in 16 patients served as controls (group 2). Graft patency and the presence or absence of high-grade stenosis at the proximal anastomotic site were evaluated. RESULTS: In group 1, 2 (3.8%) of the grafts were found occluded at MDCT or coronary angiography, and no further relevant stenosis was observed. In group 2, at postoperative MDCT all grafts were found patent without significant narrowing of the proximal anastomotic site. CONCLUSIONS: The feasibility of proximal anastomoses using the Symmetry device has been reported. Patency control with invasive angiography has been performed by other groups. With MDCT, noninvasive evaluation of proximal anastomotic quality and graft patency is possible, even if nitinol is implanted.

Aged↗

Biventricular pacing for weaning from extracorporeal circulation in heart failure.

Resynchronization of the intra- and interventricular conduction by biventricular pacing has been suggested in patients with end-stage heart failure. We present a case in which extracorporeal circulation could only be weaned after placement of an additional left ventricular pacing wire. Biventricular stimulation led to normal motion of the anterior wall and a previously bulging interventricular septum; this improved the hemodynamic situation significantly.

Aged↗

C1-esterase inhibitor reduces reperfusion injury after lung transplantation.

BACKGROUND: Activation of the complement system and polymorphonuclear neutrophilic leukocytes plays a major role in mediating reperfusion injury after lung transplantation. We hypothesized that early interference with complement activation would reduce lung reperfusion injury after transplantation. METHODS: Unilateral left lung autotransplantation was performed in 6 sheep. After hilar stripping the left lung was flushed with Euro-Collins solution and preserved for 2 hours in situ at 15 degrees C. After reperfusion the right main bronchus and pulmonary artery were occluded, leaving the animal dependent on the reperfused lung (reperfused group). C1-esterase inhibitor group animals (n = 6) received 200 U/kg body weight of C1-esterase inhibitor as a short infusion, half 10 minutes before, the other half 10 minutes after reperfusion. Controls (n = 6) underwent hilar preparation only. Pulmonary function was assessed by alveolar-arterial oxygen difference and pulmonary vascular resistance. The release of beta-N-acetylglucosaminidase served as indicator of polymorphonuclear neutrophilic leukocyte activation. Extravascular lung water was an indicator for pulmonary edema formation. Biopsy specimens were taken from all groups 3 hours after reperfusion for light and electron microscopy. RESULTS: In the reperfused group, alveolar-arterial oxygen difference and pulmonary vascular resistance were significantly elevated after reperfusion. All animals developed frank alveolar edema. The biochemical marker beta-N-acetylglucosaminidase showed significant leukocyte activation. In the C1-esterase inhibitor group, alveolar-arterial oxygen difference, pulmonary vascular resistance, and the level of polymorphonuclear neutrophilic leukocyte activation were significantly lower. CONCLUSIONS: Treatment with C1-esterase inhibitor reduces reperfusion injury and improves pulmonary function in this experimental model.

Animals↗