Search PubMed⌕ Search

Biomedical subjects

Anton Moritz

Publications and source records attributed to Anton Moritz.

At least 37 records · Page 2Linked to original sources

Echocardiographic assessment in minimally invasive mitral valve surgery.

BACKGROUND: Due to limited exposure, removal of intracavitary air and visual assessment of cardiac function during minimally invasive procedures are not always possible. We analysed the utility of intraoperative transesophageal echocardiography (TEE) and postoperative transthoracic echocardiographic (TTE) in minimally invasive mitral valve (MV) procedures. MATERIAL/METHODS: We evaluated data from 163 consecutive patients undergoing isolated minimally invasive MV replacement (n=40) or repair (n=123) via small right anterolateral thoracotomy (121 complex mitral procedures). Cardioplegic arrest was achieved using either endoaortic (n=23) or transthoracic aortic clamp (n=140). In addition to preoperative TTE, TEE was used intraoperatively before and after cardiopulmonary bypass (CPB). Postoperative TTE was performed to monitor valve function at 3 and 12 months, and at 5-year follow-up. RESULTS: Pre-CPB TEE was useful to assess valve dysfunction and assist in placement of the arterial and venous cannulas. During CPB, placement and positioning of the endoclamp were guided effectively in all but 4 patients, in whom recurrent balloon migration necessitated secondary transthoracic aortic clamping. TEE detected one acute retrograde aortic dissection and one circumflex artery occlusion. After 18.7+/-10.6 months follow-up, all patients except three improved symptomatically and had consistently good valve function. CONCLUSIONS: Intraoperative TEE is essential for minimally invasive MV surgery, because it allows immediate control of valve function before and after surgery. It is useful to detect unexpected complications requiring immediate remedy. Postoperative echocardiographic results show that minimally invasive MV surgery is a good alternative to conventional surgery even in complex MV repairs.

Adolescent↗

Aortic leaflet replacement with the new 3F stentless aortic bioprosthesis.

PURPOSE: Clinical trials with the new 3F stentless aortic bioprosthesis began October 2001, and as one of the first centers to implant this prosthesis in humans, we would like to present our experiences with this new device. DESCRIPTION: The 3F aortic bioprosthesis is a stentless biological heart valve fabricated from three equal leaflets of equine pericardium, assembled in a tubular shape, and implanted in the native aortic root to replace the patient's diseased aortic leaflets. Between January 2002 and August 2002, 24 3F aortic bioprostheses were implanted at our institution. Effective orifice area, mean gradients, and ejection fraction were evaluated by echocardiography at discharge and at 12-month follow-ups after surgery. EVALUATION: At 12-month follow-ups, the 3F bioprosthesis showed a good hemodynamic performance with a significant drop of mean gradients to 10.3 mm Hg, a mean effective orifice area of 1.7 cm2, and a mean ejection fraction of 61.5%. CONCLUSIONS: The clinical performance of the new 3F aortic bioprosthesis is comparable with regular stentless aortic valves. However its unique design facilitates implantation.

Adult↗

Pericardial patch augmentation for reconstruction of incompetent bicuspid aortic valves.

PURPOSE: Reoperation rates after repair of bicuspid aortic valves are higher than for mitral valve reconstruction. Secondary changes and small coaptation surface render repair unreliable. Satisfactory results have been reported for patch augmentation for tricuspid aortic valves. We have applied this technique for the repair of bicuspid aortic valves. DESCRIPTION: Our technique retains the bicuspid morphology of the incompetent aortic valve. A strip of glutaraldehyde-fixed pericardium is sutured to the free edge of the fused leaflet. A large coaptation surface is created, and competence of the bicuspid valve is achieved. EVALUATION: Sixteen patients underwent reconstruction of their bicuspid aortic valves by pericardial patch augmentation. There were no intraoperative or postoperative deaths. The degree of aortic regurgitation was none to trivial for all patients at a mean follow-up of 3.1 +/- 3.4 months. Planimetric effective orifice areas ranged above 2 cm2. Mean aortic gradients were 8.2 +/- 4.8 mm Hg, and the mean height of coaptation surface was 14.7 +/- 2.1 mm. CONCLUSIONS: The pericardial patch augmentation technique increases coaptation surface, and thus provides reliable early competence of reconstructed bicuspid aortic valves.

Adult↗

Minimally invasive port access versus conventional mitral valve surgery: prospective randomized study.

BACKGROUND: We compared the port access mitral valve surgery with the conventional procedure through median sternotomy in a prospective randomized study. METHODS: Forty elective patients with mitral valve disease were prospectively randomized to undergo minimally invasive (group I) or conventional (group II) mitral valve operation. The patients of group I had limited access through right small anterior thoracotomy and a femorofemoral cardiopulmonary bypass system using the endoclamp technique. To assess the efficiency and safety of the procedure, intraoperative and postoperative clinical data and markers of myocardial, cerebral, and lower limb ischemia were collected. Pulmonary function tests were performed to compare the preservation of pulmonary function. Neuropsychological tests were conducted for quantification of neurological and cognitive disorders. RESULTS: Mitral valve reconstructions were performed in 28 patients (70%) in both groups. Intraoperative procedure-associated problems were experienced in 9 patients (45%) in group I, and 6 of them (30%) had to be converted to direct transthoracic aortic clamping. Markers of myocardial and cerebral damage as well as pulmonary and neuropsychological tests did not show statistically significant difference between groups. CONCLUSIONS: The minimally invasive port access technique for mitral valve surgery can be done with similar clinical safety as procedures through median sternotomy. The problems with endoclamping have forced us to change our practice to the more simple and economic transthoracic aortic clamping technique.

Cardiopulmonary Bypass↗

Initial experience with a minimized extracorporeal bypass system: is there a clinical benefit?

BACKGROUND: Drawbacks of conventional cardiopulmonary bypass (CPB) are increased inflammatory response, deteriorated coagulation and systemic organ dysfunction. A closed extracorporeal circuit (CorX) features reduced foreign surface area and priming volume. Potential benefits were studied in comparing the CorX system with conventional CPB in arrested heart coronary artery bypass grafting (CABG). METHODS: Two hundred and four patients were randomly assigned either to CorX system (n = 101, group A) or a standard CPB with cardiotomy reservoir (n = 103, group B). Besides evaluation of perioperative data and routine blood samples, we focused on lung function and perioperative bleeding. Polymorphonuclear elastase (PMNE) and terminal complement complex (TCC) served to assess inflammatory response. RESULTS: Patient demographics and operative data did not differ between groups. Postoperative lung function was not significantly impaired comparing groups A and B. Intraoperative blood loss was significantly higher in group A compared with group B (1245 +/- 947 mL vs 313 +/- 282 mL, p < 0.0001) as well as the need of fresh frozen plasma. Postoperative chest drainage did not differ significantly between groups. Two patients in each group required re-exploration due to bleeding. One hour after CPB, PMNE as well as TCC were significantly lower in group A compared with group B (PMNE: 76 +/- 44 ng/mL vs 438 +/- 230 ng/mL, p < 0.0001; TCC: 16 +/- 8 IU/mL vs 29 +/- 19 IU/mL, p < 0.0001). CONCLUSIONS: The CorX system is safe and feasible in patients undergoing CABG. Despite of markedly reduced inflammatory reaction, no clinical benefit was observed.

Aged↗

Do pulmonary autografts provide better outcomes than mechanical valves? A prospective randomized trial.

BACKGROUND: The objective of this study was to compare the performance of pulmonary autografts with mechanical aortic valves, in the treatment of aortic valve stenosis. METHODS: Forty patients with aortic valve stenoses, and below the age of 55 years, were randomly assigned to receive either pulmonary autografts (n = 20) or mechanical valve (Edwards MIRA; Edwards Lifesciences, Irvine, CA) prostheses (n = 20). Clinical outcomes, left ventricular mass regression, effective orifice area, ejection fraction, and mean gradients were evaluated at discharge, 6 months, and one year after surgery. Follow-up was complete for all patients. RESULTS: Hemodynamic performance was significantly better in the Ross group (mean gradient 2.6 mm Hg vs 10.9 mm Hg, p = 0.0005). Overall, a significant decrease in left ventricular mass was found one year postoperatively. However, there was no significant difference in the rate and extent of regression between the groups. There was one stroke in the Ross group and one major bleeding complication in the mechanical valve group. Both patients recovered fully. CONCLUSIONS: In our randomized cohort of young patients with aortic valve stenoses, the Ross procedure was superior to the mechanical prostheses with regard to hemodynamic performance. However, this did not result in an accelerated left ventricular mass regression. Clinical advantages like reduced valve-related complications and lesser myocardial strain will have to be proven in the long term.

Aortic Valve Stenosis↗

Decreased intermediate term patency of automated proximal anastomoses evaluated by sequential ultrafast CT.

OBJECTIVE: The Symmetrytrade mark aortic connector creates proximal anastomoses of saphenous vein grafts using a nitinol implant. The device avoids partial clamping and thus possibly reduces neurologic complications. To evaluate graft patency, a single surgeon randomised study was performed in our institution. METHODS: Seventy-seven patients were randomised either to automated proximal anastomoses (group I, n=39, 61 vein grafts connected using the aortic connector, 47 as single, 15 as sequential bypasses) or controls (group II, n=38, 62 proximal anastomoses handsewn, 46 as single, 16 as sequential bypasses). Ultrafast CT-scans were performed on postoperative day 5 in 34 patients of group I and 16 patients of group II to evaluate early graft patency. Intermediate term patency was evaluated with ultrafast CT-scan in 30 patients of group I (46 grafts) and 25 patients of group II (39 grafts) 1 year after the operation. RESULTS: Two early graft occlusions were detected in group I (3.8%). In group II all evaluated grafts were patent 5 days after surgery. 11.4 months after surgery, seven out of 46 grafts were found occluded (15.2%) in group I. In the control group, only one occlusion was detected (2.6%). CONCLUSIONS: We observed a trend towards an increased occlusion rate 1 year after surgery with automated connector devices. For evaluation of long-term patency larger patient groups have to be evaluated. Other benefits of these devices have to be proven to promote their clinical application.

Adult↗

Emergency endovascular interventions for acute thoracic aortic rupture: four-year follow-up.

OBJECTIVE: High mortality and paraplegia rates associated with the surgical management of acute thoracic aortic ruptures limit its success. It was our objective to evaluate whether emergency endovascular interventions would improve the outcomes of these patients. METHODS: Sixty patients aged 28 to 83 years were admitted to our institution with an acute rupture of the thoracic aorta (27 ruptured aneurysms, 15 perforated type B dissections, 18 traumatic ruptures). Twenty-eight patients were treated surgically with cardiopulmonary bypass, and 32 patients were acutely treated with an endovascular stent graft. Medical records were reviewed for prehospital and emergency department data, operative findings, and outcomes. Patients were followed up at yearly intervals with high-resolution multidetector computed tomographic angiography. RESULTS: Perioperatively, there were 1 death (3.1%) among the 32 patients in the endovascular group and 5 deaths (17.8%) among the 28 patients in the surgical group. There were 4 late deaths in the endovascular group and 1 in the surgical group. There were 2 access failures in the endovascular group. There were 1 stroke in the endovascular group and 1 case of paraplegia in the surgical group. Three patients in the endovascular group had endovascular leaks develop that required reintervention. Two patients in the endovascular group had late thrombosis of the left subclavian artery. CONCLUSION: Despite encouraging early outcomes, midterm results suggest a trend toward increased reintervention and late complication rates in the endovascular group. Therefore continued surveillance of patients treated with stent grafts is necessary.

Aged↗

Closure of atrial and ventricular septal defects should be performed by the surgeon.

Surgeons look back on 57 years of experience in the closure of atrial septal defects (ASDs) and 46 years in the closure of ventricular septal defects (VSDs). The transcatheter approaches to repair ASDs started first in the 1980s and for VSDs 8 years later. This study sought to reveal the surgical features only given by the surgical therapy and the limitation of interventional ASD and VSD closure. A variety of surgical techniques including the minimal invasive techniques for ASD or VSD closure are well described in recent publication with good results. The surgical trend is to improve the cosmetic outcome by minimizing the size of skin incision. The latest robotically assisted technique requires only four stab wound incisions. New techniques and devices have revolutionized the transcatheter technique but could not achieve the surgical ability to close all types of ASD or VSD, control arrhythmias, and correct additional valve disease or malformation. The mortality for interventional and surgical procedures approaches zero in recent publication. The residual shunting after surgical closure of ASD varies from 2% to 7.8% versus 5% to 33% after interventional closure. General complications caused by the surgical procedure are negligible; however, the shortness of hospital stay and the cosmetic appeal is an advantage of interventional ASD closure. There is no scientific comparison of surgical vs. interventional VSD closure yet.

Cardiac Catheterization↗

Valve opening and closing dynamics after different aortic valve-sparing operations.

BACKGROUND AND AIM OF THE STUDY: Aortic valve resuspension for ascending aortic aneurysm repair is associated with removal of the sinus of Valsalva. This may cause changes in leaflet motion and thus impact on long-term durability. The opening and closing characteristics of the aortic valve leaflets after reimplantation were studied using a published technique and a modification to create a 'neosinus', and the results compared to those of an age-matched control group. METHODS: Between September 1995 and March 2002, 25 patients underwent normal aortic root reconstruction (group A), while in a further 21 patients the modified neosinus technique was used (group B). In both groups, the native valve was preserved and suspended inside a tubular prosthesis, with reimplantation of the coronary arteries. Transthoracic and transesophageal studies of aortic valve dynamics were performed intraoperatively, before hospital discharge, and at one year after surgery in all patients; the data were compared with those from a separate group of 25 matched control individuals (group C). RESULTS: The valve opening velocity was 61.3+/-20.1, 46.3+/-8 and 29.2+/-9.8 cm/s in groups A, B and C, respectively (group A versus B, p = 0.003; A versus C, p <0.0001; B versus C, p <0.0001). Closing velocity was increased to 57.5+/-23 and 43.8+/-7 cm/s in groups A and B, compared to 23.6+/-7 cm/s in group C (A versus B, p = 0.012; A versus C, p <0.0001; B versus C, p = 0.0002). In seven group A patients, the leaflets touched the prosthetic wall during systole. Slow systolic closing displacement (SCD) amounted to 7.3+/-6 % of maximal opening in group A and 12.6+/-5 % in group B (p = 0.05), compared to 21.1+/-8.3% in group C (group A versus group C, p <0.0001; B versus C, p = 0.002). CONCLUSION: Reimplantation of the natural aortic valve in a prosthetic graft causes abnormally high opening and closing speeds, with possibly increased stress. The study results showed lower valve opening and closure dynamics after the creation of a sinus bulge compared to the conventional reimplantation technique. However, mid-term clinical observations showed favorable valve competence for both types of repair. Further long-term follow up is necessary to prove whether more physiological leaflet dynamics lead to improved durability.

Adolescent↗

MDCT of the proximal anastomoses created by nitinol implants in coronary artery bypass grafting: a retrospective two-observer evaluation.

The purpose of this study was to investigate the proximal anastomosis of CABG grafts created by a nitinol aortic connector. After receiving CABG, 33 patients underwent CT examination of the heart. On the same patients, CT was performed on postoperative day 5 (4-row CT, group A) and again 1 year thereafter (16-row CT, group B). Twenty-three ACVB to RCX and 27 ACVB to RCA grafts were included. Every anastomosis was reviewed under different reformations (MIP, MPR and VRT). Interobserver correlation was determined. Five days postoperatively, 48/50 anastomoses were classified as patent. One year postoperatively, 42/50 anastomoses were classified as patent. In both groups, the aortic connector could be visualized with good quality: 1.82+/-1.10 (group A) and 1.93+/-1.22 (group B) for ACVB to RCA, similar results for ACVB to RCX grafts (MPR). Image quality at the aortic connector site did not display a significant difference for any reformation between groups (P>0.05). Within groups, MPR displayed better visualization than MIP and VRT (P<0.05). In the presence of metal implants, CT provides reliable data in evaluation of the proximal anastomosis. Sixteen-row CT does not bring a significant benefit to image quality. MPR displayed the best visualization within both groups.

Aged↗

Visualisation of non-invasive coronary bypass imaging: 4-row vs. 16-row multidetector computed tomography.

UNLABELLED: The purpose of this study was to investigate the image quality of coronary artery bypass graft visualization in 4- and 16-row multidetector CT using multiple imaging reformations. MATERIAL AND METHODS: One hundred sixteen patients underwent CT examination of the heart after receiving CABG. Group A (n=58) received 4-row MDCT; group B (n=58) received 16-row MDCT. Various bypass types such as LITA to LAD and venous grafts to the RCA and RCX were included in the study. A five-point Likert scale was used to grade image quality. Each bypass was reviewed under different imaging reformations: thin slap maximum intensity projection (MIP thin), multiplanar reformation (MPR) and volume rendering technique (VRT). Special attention was paid to the delineation of the distal anastomosis. Interobserver correlation was determined. RESULTS: From 289 bypass grafts examined, 279 (96.54%) were classified as patent and 10 (3.46%) as not patent. Except for the distal anastomosis, 16-row MDCT showed significantly better results for all segments of bypasses. Comparison of reformations within group A and B showed that MIP thin (P<0.05) and VRT (P<0.05) displayed better visualization as compared to MPR. CONCLUSION: Significantly better imaging of all bypass types is possible using 16-row MDCT as compared to 4-row MDCT. Assessment of the distal anastomosis yields no difference between 4- and 16-row technology.

Adult↗

Current status of robotically assisted coronary revascularization.

This article reviews the current status of totally endoscopic coronary revascularization using telemanipulation systems for robotic assistance. Current challenges in implementing a robotic surgical program are discussed, and application of the technology in both arrested and beating heart procedures is considered.

Cardiac Surgical Procedures↗

Successful treatment of deep sternal infections following open heart surgery by bilateral pectoralis major flaps.

OBJECTIVES: Severe sternum necrosis requiring extended resection necessitates plastic reconstruction of the resulting defect and stabilization of the chest. We analyzed the outcome of patients undergoing bilateral pectoralis major flap repair on functional and cosmetic results, chest stabilization and pulmonary function. METHODS: Twelve patients undergoing cardiac surgery between 1997 and 2001 suffered from a deep mediastinal wound infection and sternum necrosis. After a mean of two attempts of extensive wound debridement, all 12 patients underwent complete sternal resection with plastic reconstruction by bilateral pectoralis major flaps. Risk factors were obesity (n=10) and diabetes (n=11). Six months postoperatively patients underwent physical examination, pulmonary function testing and functional CT scan. RESULTS: Three patients died in hospital (two septic multiorgan failure, one heart failure) and nine were discharged with complete wound closure. One patient suffered a lethal stroke during follow-up. At 6-month follow-up no recurrent sternum infection had occurred. Chest stability was satisfactory without impairment of pulmonary function (VC 77.5+/-12.1% at follow-up vs 77.8+/-12.5% preoperatively). Mobility and force of arms and shoulder were adequate; at CT scan the maximum distance change between the former sternoclavicular joint in inspiration versus expiration was minimal. Quality of life questionnaires showed no significant limitations except a disturbed sleep and mild restriction of executing hobbies and social activities. CONCLUSIONS: Bilateral pectoralis major flap repair is a safe technique to cure severe mediastinitis necessitating complete sternal resection. Wounds close without extensive reconstructive surgery. Cosmetic results as well as stabilization of the chest were good. Patients reported an almost uncompromised quality of life without respiratory impairment.

Aged↗

Automatic connector devices for proximal anastomoses do not decrease embolic debris compared with conventional anastomoses in CABG.

OBJECTIVE: Emboli generated during cardiac surgery have been associated with aortic clamping and manipulation. Proximal anastomotic devices are thought to be less traumatic by eliminating partial clamping, potentially resulting in fewer adverse outcomes. Intra-aortic filtration has been shown to effectively capture particulate debris. We compared the amount of debris released using intra-aortic filtration and the clinical outcomes between conventionally handsewn and automated proximal anastomoses. METHODS: Seventy-seven patients undergoing primary coronary artery bypass grafting with cardiopulmonary bypass were enrolled in a prospective randomized study. Patients were assigned to the anastomotic device Group I (Symmetry Aortic Connector, n = 39) or the conventional handsewn anastomosis control Group II (n = 38). Proximal anastomoses were performed before cardiopulmonary bypass in both groups. Intra-aortic Filter 1 (EMBOL-X)was deployed prior to partial clamping or puncturing the aorta for device application and removed after the proximal anastomosis was completed. Prior to cross-clamp removal, a second filter was inserted (Filter 2). A core laboratory performed quantitative and histologic analyses of the debris captured. Clinical outcomes included adverse events, neurocognitive test scores, graft patency, and mortality. RESULTS: Preoperative variables and risk factors were not significantly different between Groups I and II (EuroSCORE 3.9+/-2.6 vs. 4.2+/-2.5). Filter analyses showed no significant difference between Groups I and II in Filter 1 or 2 for either surface area of particles or total number of particles (P> 0.005). There was a significant decrease between Filters 1 and 2 in both Groups for surface area of particles (Group I: 18.5+/-23.8 mm2 vs. 10.7+/-16.3 mm2, P = 0.017; Group II: 15.0+/-15.4 mm2 vs. 6.9+/-.6.5 mm2, P = 0.004), and for total number of particles in Group II (8.6+/-3.7 vs. 7.1+/-2.4, P = 0.023). No significant differences were observed between Group I (device) and Group II (control) outcomes for myocardial infarction, neurocognitive deficit, stroke, length of stay, graft occlusion, or mortality. CONCLUSIONS: The application of proximal aortic connectors without partial clamping does not reduce particulate emboli or affect clinical outcomes compared with conventional anastomoses. Cross-clamping during cardiopulmonary bypass produces less particulate debris than conventional or automated proximal anastomoses performed off-pump, suggesting a major source of emboli is the anastomotic process.

Adult↗

In vivo inhibition of neutrophil activity by a FAS (CD95) stimulating module: arterial in-line application in a porcine cardiac surgery model.

OBJECTIVE: Cardiac surgery with cardiopulmonary bypass is associated with aberrant neutrophil activation and potentially severe pathogenic sequelae. This experimental study was done to evaluate a leukocyte inhibition module that rapidly inactivates neutrophils through CD95 stimulation. METHODS: German landrace pigs (4 groups, each n = 5) underwent cardiac surgery without cardiopulmonary bypass (group I), with cardiopulmonary bypass (group II), with cardiopulmonary bypass plus a leukocyte filter (group III), and with cardiopulmonary bypass plus a leukocyte inhibition module (group IV). The leukocyte filter or leukocyte inhibition module was introduced into the arterial line of the heart-lung machine. RESULTS: Leukocyte counts were decreased by up to 43% in group IV compared with values in group II (P =.023). In group IV, but not in groups I to III, no delay in spontaneous neutrophil apoptosis was observed after annexin V-propidium iodide staining. Late apoptotic (11.7%) or necrotic neutrophils (9.3%) were detected in 2 animals (group IV). Tumor necrosis factor alpha serum levels increased over time in groups I to III (>2-fold) but remained at baseline levels in group IV (P <.05). Interleukin 8-mediated chemotactic neutrophil transmigration activity increased over time in groups I to III but was totally abrogated in group IV at any time point. The perioperative increase of creatine kinase and creatine kinase MB levels was lower in groups III (1.5-fold and 1.3-fold, respectively) and IV (1.2-fold and 1.5-fold, respectively) compared with values in group II (both 1.9-fold). CONCLUSIONS: The leukocyte inhibition module downregulated cardiopulmonary bypass-related neutrophil activity and thus might be beneficial in cardiac surgery and other clinical settings with unappreciated neutrophil activation.

Animals↗

Progress in CT imaging for the cardiac surgeon.

The aim of this article is to critically assess the role of multidetector-row CT (MDCT) in the field of cardiothoracic surgery. In the beginning, a short overview is given about technical aspects such as scan protocols, optimal image reconstruction, image reformation techniques, data evaluation, and data presentation. This is followed by sections about possible indications for cardiothoracic surgery and future prospects for this technology. For the cardiac surgeon, the main benefit of MDCT lies in the combination of large scan-volume coverage, high spatial resolution, proper identification of calcifications, and the simultaneous registration of other thoracic structures. Preoperative applications may include the assessment of cardiac valves, noninvasive evaluation of large thoracic vessels, staging of cardiac tumors, and planning of minimally invasive surgical procedures. After surgery, MDCT examinations particularly facilitate an early identification of severe postoperative complications. MDCT may also be used to assess coronary artery bypass graft patency and to identify transplant-related complications in heart transplant recipients at an early stage. New technological developments such as 64-row MDCT or flat panel computed tomography will further increase the field of possible indications.

Coronary Artery Bypass↗

Reconstructed bicuspid aortic valve after 10 years: clinical and echocardiographic follow-up.

BACKGROUND: Sixteen patients (mean age, 30.9 +/- 12.9 years; range, 9-79 years) with incompetent bicuspid aortic valves underwent valve-sparing correction between 1992 and 1995. METHODS: All patients underwent triangular resection of the enlarged leaflet. In addition, 13 patients underwent commissuroplasty. In 3 patients leaflet perforations were corrected with glutaraldehyde-fixed autologous pericardial patch. All patients underwent annual echocardiographic and clinical examinations at our institution. RESULTS: During follow-up 1 patient died of heart failure, and 3 patients underwent reoperations because of valve incompetence or dilatation of the sinus. Two patients underwent reoperation perioperatively. At long-term follow-up (mean, 10.06 +/- 1.01 years) the remaining 10 patients were in New York Heart Association class I. No patient was receiving anticoagulation, and no thromboembolic, bleeding, or endocarditis events were observed in 107.2 cumulative patientyears of follow-up. Mean grade of regurgitation was 0.7 +/- 0.5; mean aortic flow velocity was 2.29 +/- 0.47 m/s. Optimal valvular function led to normal ventricular diameters (left ventricular end systolic diameter, 39.2 +/- 4.3 mm; left ventricular end diastolic diameter, 56.2 +/- 5.9 mm) and normal ventricular function (fractional shortening, 31.5% +/- 0.1%). The dimensions of the aortic root were stable from 1-year to late followup (mean aortic annulus, 27.1 +/- 6.8 mm; sinus of Valsalva, 33.0 +/- 7.1 mm; sinotubular junction, 34.1 +/- 7.7 mm; ascending aorta, 31.6 +/- 7.4 mm). CONCLUSION: In contrast to early follow-up results of 5 reoperations, clinical and echocardiographic results were excellent for 10 patients who had undergone reconstruction of bicuspid incompetent aortic valves, and the patients were in stable condition after 10 years. However, the mode of early failure is unknown. Reconstruction of bicuspid valves is possible in selected patients.

Adolescent↗