Search PubMed⌕ Search

Biomedical subjects

Andy McShea

Publications and source records attributed to Andy McShea.

9 recordsLinked to original sources

Building addressable libraries: The use of a mass spectrometry cleavable linker for monitoring reactions on a microelectrode array.

Time-of-flight secondary ion mass spectrometry (TOF SIMS) has been used in conjunction with a mass spectrometry cleavable linker to determine the percent conversion of reactions that were conducted site-selectively on an addressable microelectrode array. When combined with fluorescence techniques for analysis of the reactions, the TOF SIMS experiment provides a means for optimization of both reaction confinement and reaction efficiency on the microelectrode arrays.

Calibration↗

Electrochemically generated acid and its containment to 100 micron reaction areas for the production of DNA microarrays.

An addressable electrode array was used for the production of acid at sufficient concentration to allow deprotection of the dimethoxytrityl (DMT) protecting group from an overlaying substrate bound to a porous reaction layer. Containment of the generated acid to an active electrode of 100 micron diameter was achieved by the presence of an organic base. This procedure was then used for the production of a DNA array, in which synthesis was directed by the electrochemical removal of the DMT group during synthesis. The product array was found to have a detection sensitivity to as low as 0.5 pM DNA in a complex background sample.

Acids↗

CombiMatrix oligonucleotide arrays: genotyping and gene expression assays employing electrochemical detection.

Electrochemical detection has been developed and assay performances studied for the CombiMatrix oligonucleotide microarray platform that contains 12,544 individually addressable microelectrodes (features) in a semiconductor matrix. The approach is based on the detection of redox active chemistries (such as horseradish peroxidase (HRP) and the associated substrate TMB) proximal to specific microarray electrodes. First, microarray probes are hybridized to biotin-labeled targets, second, the HRP-streptavidin conjugate binds to biotin, and enzymatic oxidation of the electron donor substrate then occurs. The detection current is generated due to electro-reduction of the HRP reaction product, and it is measured with the CombiMatrix ElectraSense Reader. Performance of the ElectraSense platform has been characterized using gene expression and genotyping assays to analyze: (i) signal to concentration dependence, (ii) assay resolution, (iii) coefficients of variation, (CV) and (iv) array-to-array reproducibility and data correlation. The ElectraSense platform was also compared to the standard fluorescent detection, and good consistency was observed between these two different detection techniques. A lower detection limit of 0.75 pM was obtained for ElectraSense as compared to the detection limit of 1.5 pM obtained for fluorescent detection. Thus, the ElectraSense platform has been used to develop nucleic acid assays for highly accurate genotyping of a variety of pathogens including bio-threat agents (such as Bacillus anthracis, Yersinia pestis, and other microorganisms including Escherichia coli, Bacillus subtilis, etc.) and common pathogens of the respiratory tract (e.g. influenza A virus).

Bacteriophage lambda↗

Validation of a fully integrated microfluidic array device for influenza A subtype identification and sequencing.

Rapid detection and identification of influenza virus is becoming increasingly important in the face of concerns over an influenza pandemic. A fully integrated and self-contained microfluidic device has been developed to rapidly identify influenza A hemagglutinin and neuraminidase subtypes and sequence portions of both genes. The device consists of a DNA microarray with 12 000 features and a microfluidic cartridge that automates the fluidic handling steps required to carry out a genotyping assay for pathogen identification and sequencing. The fully integrated microfluidic device consists of microfluidic pumps, mixers, valves, fluid channels, reagent storage chambers, and DNA microarray silicon chip. Microarray hybridization and subsequent fluidic handling and reactions were performed in this fully automated and miniature device before fluorescent image scanning of the microarray chip. A micromixing technique based on gas bubbling generated by electrochemical micropumps was developed. Low-cost check valves were implemented in the cartridge to prevent cross talk of the stored reagents. The genotyping results showed that the device identified influenza A hemagglutinin and neuraminidase subtypes and sequenced portions of both genes, demonstrating the potential of integrated microfluidic and microarray technology for multiple virus detection. The device provides a cost-effective solution to eliminate labor-intensive and time-consuming fluidic handling steps and allows the detection and identification of influenza virus in a rapid and automated fashion.

DNA, Viral↗

Fully integrated miniature device for automated gene expression DNA microarray processing.

A DNA microarray with 12,000 features was integrated with a microfluidic cartridge to automate the fluidic handling steps required to carry out a gene expression study of the human leukemia cell line (K562). The fully integrated microfluidic device consists of microfluidic pumps/mixers, fluid channels, reagent chambers, and a DNA microarray silicon chip. Microarray hybridization and subsequent fluidic handling and reactions (including a number of washing and labeling steps) were performed in this fully automated and miniature device before fluorescent image scanning of the microarray chip. Electrochemical micropumps were integrated into the cartridge to provide pumping of liquid solutions. The device was completely self-contained: no external pressure sources, fluid storage, mechanical pumps, mixers, or valves were necessary for fluid manipulation, thus eliminating possible sample contamination and simplifying device operation. Fluidic experiments were performed to study the on-chip washing efficiency and uniformity. A single-color transcriptional analysis of K562 cells with a series of calibration controls (spiked-in controls) to characterize this new platform with regard to sensitivity, specificity, and dynamic range was performed. The device detected sample RNAs with a concentration as low as 0.375 pM. Experiment also showed that the performance of the integrated microfluidic device is comparable with the conventional hybridization chambers with manual operations, indicating that the on-chip fluidic handling (washing and reaction) is highly efficient and can be automated with no loss of performance. The device provides a cost-effective solution to eliminate labor-intensive and time-consuming fluidic handling steps in genomic analysis.

Bacteriophage lambda↗

Integrated microfluidic biochips for DNA microarray analysis.

A fully integrated and self-contained microfluidic biochip device has been developed to automate the fluidic handling steps required to perform a gene expression study of the human leukemia cell line (K-562). The device consists of a DNA microarray semiconductor chip with 12,000 features and a microfluidic cartridge that consists of microfluidic pumps, mixers, valves, fluid channels and reagent storage chambers. Microarray hybridization and subsequent fluidic handling and reactions (including a number of washing and labeling steps) were performed in this fully automated and miniature device before fluorescent image scanning of the microarray chip. Electrochemical micropumps were integrated in the cartridge to provide pumping of liquid solutions. A micromixing technique based on gas bubbling generated by electrochemical micropumps was developed. Low-cost check valves were implemented in the cartridge to prevent cross-talk of the stored reagents. A single-color transcriptional analysis of K-562 cells with a series of calibration controls (spiked-in controls) was performed to characterize this new platform with regard to sensitivity, specificity and dynamic range. The device detected sample RNAs with a concentration as low as 0.375 pM. Detection was quantitative over more than 3 orders of magnitude. Experiments also demonstrated that chip-to-chip variability was low, indicating that the integrated microfluidic devices eliminate manual fluidic handling steps that can be a significant source of variability in genomic analysis.

Biomarkers↗

Nuclear factor-kappaB regulates beta-cell death: a critical role for A20 in beta-cell protection.

Apoptotic beta-cell death is central to the pathogenesis of type 1 diabetes and may be important in islet graft rejection. Despite this, genetic control of beta-cell apoptosis is only poorly understood. We report that inhibition of gene transcription sensitized beta-cells to tumor necrosis factor (TNF)-alpha-induced apoptosis, indicating the presence of a regulated antiapoptotic response. Using oligonucleotide microarrays and real-time PCR, we identified TNFAIP3/A20 as the most highly regulated antiapoptotic gene expressed in cytokine-stimulated human and mouse islets. Cytokine induction of A20 mRNA in primary islets and insulinoma cells was rapid and observed within 1 h, consistent with A20 being an immediate early response gene in beta-cells. Regulation of A20 was nuclear factor-kappaB (NF-kappaB)-dependent, two NF-kappaB sites within the A20 promoter were found to be necessary and sufficient for A20 expression in beta-cells. Activation of NF-kappaB by TNF receptor-associated factor (TRAF) 2, TRAF6, NF-kappaB-inducing kinase, or protein kinase D, which transduce signals downstream of Toll-like receptors, TNF receptors, and free radicals, respectively, were all potent activators of the A20 promoter. Moreover, A20 expression was induced in transplanted islets in vivo. Finally, A20 expression was sufficient to protect beta-cells from TNF-induced apoptosis. These data demonstrate that A20 is the cardinal antiapoptotic gene in beta-cells. Further, A20 expression is NF-kappaB dependent, thus linking islet proinflammatory gene responses with protection from apoptosis.

Animals↗

Identification and characterization of human cytomegalovirus-encoded microRNAs.

MicroRNAs (miRNAs) are an extensive class of noncoding genes that regulate gene expression through posttranscriptional repression. Given the potential for large viral genomes to encode these transcripts, we examined the human cytomegalovirus AD169 genome for miRNAs using a bioinformatics approach. We identified 406 potential stem-loops, of which 110 were conserved between chimpanzee cytomegalovirus and several strains of human cytomegalovirus. Of these conserved stem-loops, 13 exhibited a significant score using the MiRscan algorithm. Examination of total RNA from human cytomegalovirus-infected cells demonstrated that 5 of the 13 predicted miRNAs were expressed during infection. These studies demonstrate that human cytomegalovirus encodes multiple conserved miRNAs and suggest that human cytomegalovirus may utilize an miRNA strategy to regulate cellular and viral gene function.

Base Sequence↗