Search PubMed⌕ Search

Biomedical subjects

Andre Weimann

Publications and source records attributed to Andre Weimann.

At least 19 recordsLinked to original sources

Initial and 6 weeks postoperative structural properties of soft tissue anterior cruciate ligament reconstructions with cross-pin or interference screw fixation: an in vivo study in sheep.

PURPOSE: The purpose of this study was to evaluate the detrimental effects of interference screw fixation on soft tissue anterior cruciate ligament (ACL) reconstruction after 6 weeks and compare them with a cross-pin technique. METHODS: In an intra-articular model, ovine soft tissue grafts were fixed with two 3.3-mm biodegradable pins or with interference screws. Maximum load, yield load, and stiffness of the femur-graft-tibia complex were evaluated immediately after surgery and 6 weeks postoperatively. RESULTS: For knees with interference screw fixation, strength deteriorated by 81% and stiffness deteriorated by 67%. For knees with double cross-pin fixation, strength deteriorated by 48% and stiffness improved by 52%. These differences were statistically significant. At the time of surgery, all grafts failed by slippage of the graft past the screw or by cross-pin failure. At 6 weeks postoperatively, the grafts of both groups failed at the tibial or femoral tunnel entrance. CONCLUSIONS: After 6 weeks, the biomechanical characteristics of grafts that were fixed with cross-pins were superior to those of grafts after interference screw fixation. CLINICAL RELEVANCE: Because of significantly inferior biomechanical stability after interference screw fixation, a less aggressive program of rehabilitation might be recommended.

Achilles Tendon↗

Biomechanical evaluation of different fixation methods for tibial eminence fractures.

BACKGROUND: Tibial eminence fractures have become more common, but the best method of fixing these fractures arthroscopically has not been elucidated. OBJECTIVE: The objective of this study is to assess the stability of different fixation methods for tibial eminence fractures. STUDY DESIGN: Controlled laboratory study. METHODS: The authors evaluated the initial fixation strength of 4 different fixation techniques for tibial eminence fractures (2 screws, 1 screw, suture fixation with 1 mm Ethibond, and suture fixation with No. 5 FiberWire) using single cycle and cyclic loading tests. The tests were performed by loading the knee with an anterior tibial shear force. RESULTS: Suture cerclage with the FiberWire showed significantly higher maximum load (599.6 N) and stiffness (36.99 N/mm) than all other fixation methods tested. The lowest maximum load in the single cycle loading test was observed in the group with 2 screws (1 screw, 371.2 N; 2 screws, 249.8 N). The lowest stiffness was found in the Ethibond group (14.5 N/mm). After 1000 cycles of loading, the maximum load of the FiberWire fixation was significantly higher than the maximum load of the Ethibond fixation (399.4 N), the fixation with 1 screw (354.2 N), and the fixation with 2 screws (301.5 N). CONCLUSION: These biomechanical data suggest that under cyclic loading conditions, suture fixation of tibial eminence fractures provides more fixation strength than screw fixation. CLINICAL RELEVANCE: A second screw has no positive effect on the biomechanical characteristics of screw fixation.

Animals↗

Biomechanical evaluation of two techniques for double-bundle anterior cruciate ligament reconstruction: one tibial tunnel versus two tibial tunnels.

BACKGROUND: This research was undertaken to determine whether there is a need for a second tibial tunnel in anatomic anterior cruciate ligament reconstruction. HYPOTHESIS: Anatomic two-bundle reconstruction with two tibial tunnels restores knee anterior tibial translation in response to 134 N and to 5-N.m internal tibial torque combined with 10-N.m valgus torque more closely to normal than does double-bundle reconstruction with one tibial tunnel. STUDY DESIGN: Controlled laboratory study. METHODS: Ten cadaveric knees were subjected to a 134-N anterior tibial load at 0 degrees, 30 degrees, 60 degrees, and 90 degrees and to 5-N.m internal tibial torque and 10-N.m valgus torque at 15 degrees and 30 degrees. Resulting knee kinematics and in situ force in the anterior cruciate ligament or replacement graft were determined by using a robotic/universal force-moment sensor testing system for (1) intact, (2) anterior cruciate ligament-deficient, (3) double-bundle/one tibial tunnel, and (4) double-bundle/two tibial tunnels. RESULTS: Anterior tibial translation for the reconstruction with two tibial tunnels was significantly closer to that of the intact knee than was the reconstruction with one tibial tunnel at 0 degrees and 30 degrees of flexion (0 degrees = 3.82 vs 6.0 mm, P < .05; 30 degrees = 7.99 vs 11 mm, P < .05). The in situ force normalized to the intact anterior cruciate ligament for the reconstruction with two tibial tunnels was significantly higher than the in situ force of the reconstruction with one tibial tunnel (30 degrees = 89 vs 82 N, P < .05). With a combined rotatory load, the anterior tibial translation of specimens with a tibial two-tunnel technique was significantly lower than that of specimens with one tunnel (0 degrees = 5.7 vs 8.4 mm, P < .05; 30 degrees = 7.5 vs 9.5 mm, P < .05). CONCLUSIONS: Anatomic reconstruction with two tibial tunnels may produce a better biomechanical outcome, especially close to extension. CLINICAL RELEVANCE: At the time of initial fixation, there appears to be a small biomechanical advantage to the second tibial tunnel in the setting of two-bundle anterior cruciate ligament reconstruction.

Aged↗

Initial fixation strength of a new hybrid technique for femoral ACL graft fixation: the bone wedge technique.

BACKGROUND: Aperture fixation with interference screws matching the diameter of the tunnel is associated with the risk of graft laceration and graft rotation. HYPOTHESIS: A hybrid fixation technique (extracortical and aperture fixation) with undersized interference screw placed behind a bone wedge provides a higher fixation strength as aperture fixation with a screw alone matching the size of the tunnel. STUDY DESIGN: Experimental laboratory study. METHODS: We evaluated the initial fixation strength (single cycle and cyclic loading tests) of hybrid and interference screw aperture fixation using different sized interference screws in porcine knees. RESULTS: Analysis of yield load, maximum load and stiffness in the single cycle loading test showed no statistically significant differences for hybrid fixation with a 1 mm undersized screw and aperture fixation with a screw matching the size of the tunnel. The use of an undersized screw alone resulted in low fixation strength. CONCLUSION: The initial fixation strength of the hybrid technique with undersized screws is comparable to that of interference screw fixation matching the size. CLINICAL RELEVANCE: The new "bone wedge fixation" is an alternative for ACL graft fixation without the risk of graft laceration and graft rotation.

Analysis of Variance↗

Initial fixation strength of a hybrid technique for femoral ACL graft fixation.

Aperture fixation with interference screws matching the diameter of the tunnel is associated with the risk of graft laceration and graft rotation. A hybrid fixation technique (extracortical and aperture fixation) with undersized interference screws provides a higher fixation strength when compared to an aperture fixation using only a screw matching the size of the tunnel and also reduces the risk of graft laceration. This research is an experimental laboratory study. We evaluated the initial fixation strength at time-zero of an extracortical-, a hybrid- and an aperture fixation in ACL reconstruction using extracortical buttons and different sized interference screws in porcine knees. The tests were performed using a single cycle and cyclic loading protocol. Analysis of yield load, maximum load and stiffness in the single cycle loading test showed no statistically significant differences for hybrid fixation with a 1 mm undersized screw and aperture fixation with a screw matching the size of the tunnel. Cyclic loading tests showed a statistically significant difference between hybrid and aperture fixation. The use of an undersized screw alone in aperture fixation resulted in insufficient fixation strength. The initial fixation strength of the hybrid technique with undersized screws is higher compared to an interference screw fixation alone. The hybrid fixation technique is an alternative for ACL graft fixation.

Absorbable Implants↗

Elongation and structural properties of meniscal repair using suture techniques in distraction and shear force scenarios: biomechanical evaluation using a cyclic loading protocol.

BACKGROUND: Most biomechanical studies on meniscal repairs have focused on testing distraction scenarios to evaluate structural properties of the repaired meniscus. An application of shear forces might replicate the in vivo situation more closely. HYPOTHESIS: In the shear force scenario, meniscal repair using a vertical suture technique will result in significantly less elongation when subjected to a cyclic loading protocol than that resulting from a horizontal suture technique. STUDY DESIGN: Controlled laboratory study. METHODS: In fresh-frozen porcine menisci (n = 10 in each group), horizontal and vertical 2.0 Ethibond suturing techniques were tested in distraction and shear force scenarios. Elongation after 1000 cycles between 5 and 20 N and the structural properties such as stiffness, yield load, maximum load to failure, and failure mode were evaluated using a testing machine at a rate of 12.5 mm/s. RESULTS: In the distraction force scenario, no statistically significant difference in elongation after cyclic loading was found between specimens repaired with vertical or horizontal suture techniques. After 1000 cycles of cyclic loading in the shear force scenario, the horizontal suturing revealed significantly less elongation (2.8 +/- 1.1 mm) than did the vertical suture technique (4.6 +/- 2.0 mm). No statistically significant difference in yield and maximum load was found (P > .05). CONCLUSION: The results of the present study do not support the authors' hypothesis. In the shear force test, horizontal sutures were superior to vertical suture techniques. CLINICAL RELEVANCE: Meniscal repair with horizontal suture techniques can withstand elongation due to shear forces more effectively than can vertical mattress sutures.

Animals↗

Graft laceration and pullout strength of soft-tissue anterior cruciate ligament reconstruction: in vitro study comparing titanium, poly-d,l-lactide, and poly-d,l-lactide-tricalcium phosphate screws.

PURPOSE: The aim of part 1 of this study was to compare the structural properties of tibia-graft-interference screw constructs of soft-tissue graft fixation via the anterior cruciate ligament (ACL) by use of different interference screws. In part 2 the influence of graft laceration as a result of 1 single interference screw insertion on the mechanical properties of the graft was evaluated. METHODS: In part 1 of the study, in a bovine knee model, soft-tissue graft fixation with titanium, biodegradable poly-D,L-lactide (PLDLA), and PLDLA-tricalcium phosphate (TCP) interference screws was performed, and the structural properties were determined by use of a materials testing machine at a rate of 12.5 mm/s. In part 2 the bone was cut after 1 single insertion of titanium, PLDLA, or PLDLA-TCP interference screws, and the mechanical properties of the graft were determined. RESULTS: Soft-tissue graft fixation with a biodegradable PLDLA interference screw showed a statistically significantly higher maximum load when compared with PLDLA-TCP and titanium interference screws. PLDLA-TCP screw fixation revealed a significantly higher ultimate load than titanium screw fixation. The mechanical properties of the grafts after 1 single insertion of PLDLA-TCP interference screws showed a statistically significantly higher stiffness, yield load, and maximum load when compared with the PLDLA and titanium interference screw groups. CONCLUSIONS: The results of this study suggest that the use of a titanium screw to fix a soft-tissue graft in cruciate ligament reconstruction surgery may cause damage to the graft. Soft-tissue ACL reconstruction fixed with a PLDLA interference screw resulted in a significantly higher pullout strength than ACL reconstructions fixed with a PLDLA-TCP or titanium interference screw. CLINICAL RELEVANCE: In contrast to fixation with a biodegradable interference screw, fixation with a titanium interference screw may damage the integrity of a soft-tissue graft in cruciate ligament reconstruction and should therefore be avoided.

Absorbable Implants↗

Importance of femoral tunnel placement in double-bundle posterior cruciate ligament reconstruction: biomechanical analysis using a robotic/universal force-moment sensor testing system.

BACKGROUND: Previous studies have identified the femoral attachment of the posterior cruciate ligament fibers as one of the primary determinants of fiber tension behavior. In addition, a double-bundle posterior cruciate ligament reconstruction has been shown to restore the intact knee kinematics more closely than does a single-bundle reconstruction. HYPOTHESIS: An anterior tunnel position in double-bundle posterior cruciate ligament reconstruction restores the biomechanics of the normal knee more closely than does a posterior tunnel position. STUDY DESIGN: Controlled laboratory study. METHODS: Kinematics and in situ forces of human knees after double-bundle posterior cruciate ligament reconstruction with 2 different femoral tunnel positions (anterior vs posterior) were evaluated using a robotic/universal force-moment sensor testing system. Within the same specimen, the resulting knee kinematics and in situ forces were compared. For statistical analysis, 2-way analysis of variance repeated measures were performed. RESULTS: The femoral tunnel position of the double-bundle hamstring graft had significant effect on the resulting posterior tibial displacement and in situ forces of the hamstring grafts. The anterior femoral tunnel position provided significantly less posterior tibial translation than did the posterior tunnel position. There was a tendency toward higher in situ forces of grafts fixed in the anterior tunnel when compared to the posterior position, but this difference was statistically not significant. CONCLUSION: An anterior position of the bone tunnels in double-bundle posterior cruciate ligament reconstruction restores the normal knee kinematics more closely than does a posterior position of the tunnels. CLINICAL RELEVANCE: In double-bundle posterior cruciate ligament reconstruction, posterior placement of the tunnel should be avoided.

Aged↗

Joint kinematics and in situ forces after single bundle PCL reconstruction: a graft placed at the center of the femoral attachment does not restore normal posterior laxity.

INTRODUCTION: Femoral tunnel placement has a great influence on the clinical outcome after PCL reconstruction. MATERIALS AND METHODS: Using a robotic/universal force moment sensor (UFS) testing system, we examined joint kinematics and in situ forces of human knees following soft-tissue single bundle PCL reconstruction fixed at the center of the femoral attachment. RESULTS: Posterior tibial translation significantly increased at all flexion angles after transsection of the posterior cruciate ligament (p<0.05). PCL reconstruction resulted in significantly less posterior tibial translation at all flexion angles when compared to the PCL deficient knee (p<0.05). The differences in the in situ force between the intact ligament and the reconstructed graft were statistical significant (p<0.05). CONCLUSION: Single bundle PCL reconstruction with a soft-tissue graft fixed at the center of the femoral attachment is able to reduce the posterior tibial translation significantly. However, it cannot restore kinematics of the intact knee and in situ forces of the intact PCL.

Aged↗

A controlled prospective case control study of a prevention training program in female team handball players: the German experience.

BACKGROUND: Few authors have investigated the effectiveness of preventive intervention in European team handball. PURPOSE: The aim of the present study was to evaluate the effects of a prevention program on the incidence of injuries in female European team handball players. STUDY DESIGN: Prospective controlled study. METHODS: Ten female handball teams (134 players) took part in the prevention program (1. Information about injury mechanism, 2. Balance-board exercises, 3. Jump training) while 10 other teams (142 players) were instructed to train as usual. Over one season all injuries were documented weekly. RESULTS: Ankle sprain was the most frequent diagnosis in both groups with 11 ankle sprains in the control group and 7 ankle sprains in the intervention group (Odds ratio: 0.55, 95% confidence interval: 0.22-1.43). The knee was the second frequent injury site. In the control group 5 of all knee injuries were anterior cruciate ligament (ACL) ruptures (incidence: 0.21 per 1000 h) in comparison with one in the intervention group (incidence: 0.04 per 1000 h). Odds ratio was 0.17 with 95% confidence interval of 0.02-1.5. CONCLUSIONS: This study confirms that proprioceptive and neuromuscular training is appropriate for the prevention of knee and ankle injuries among female European team handball players.

Adult↗

Primary stability of hamstring graft fixation with biodegradable suspension versus interference screws.

PURPOSE: During the early postoperative period, the stability of the fixation of a hamstring graft to the bone tunnel is the primary factor in limiting rehabilitation. The aim of this study was to evaluate if the initial fixation strength of a new suspension screw is comparable to that of the biodegradable interference screw fixation technique in the hamstring reconstruction of the anterior cruciate ligament (ACL). TYPE OF STUDY: Experimental laboratory study. METHODS: We evaluated the initial fixation strength of a biodegradable poly-L-lactide/tri-calcium phosphate (PLLA/TCP) screw that suspended the graft in the bone tunnel and compared it with the strength of an interference screw for fixation of hamstring grafts in ACL reconstruction using bovine knees. Single-cycle and cyclic loading tests were performed using a materials testing machine. RESULTS: The suspension screw provided a significantly higher yield load and ultimate failure load than the interference screw. There was no significant difference in the stiffness of both techniques. The typical failure mode for the suspension screw was fracture of the screw and for the interference screw it was slippage of the graft past the screw. In cyclic testing, both methods of fixation ran out to 1,000 cycles up to 250 N with a mean displacement of 2.6 mm (range, 1.8 to 3.3 mm) for the suspension screw and 4.1 mm (range, 2.3 to 6.0 mm) for the interference screw. Only the grafts fixed with the suspension screw survived a protocol with 1,000 cycles up to 400 N. CONCLUSIONS: Our biomechanical data suggest that hamstring graft fixation using a biodegradable PLLA/TCP suspension screw provides an alternative to interference screw fixation. CLINICAL RELEVANCE: Hamstring graft fixation using a suspension screw provides a reasonable alternative to interference screw fixation.

Absorbable Implants↗

Cyclic loading comparison between biodegradable interference screw fixation and biodegradable double cross-pin fixation of human bone-patellar tendon-bone grafts.

PURPOSE: The aim of this study was to compare ultimate load, yield load, stiffness, and displacement after cyclic loading of a cross-pin technique and an interference screw technique for the fixation of bone-patellar tendon-bone (BPTB) grafts in anterior cruciate ligament (ACL) reconstruction. TYPE OF STUDY: Biomechanical in vitro study. METHODS: The devices tested were 2 2.7-mm biodegradable pins (RigidFix; Ethicon, Mitek Division, Norderstedt, Germany) and biodegradable interference screws (Absolute; Innovasive Devices, Marlborough, MA). Each device was used for the fixation of 10 8-mm, 9-mm, or 10-mm sized human BPTB grafts in tunnels drilled in bovine knees. Ultimate load, yield load, stiffness, and displacement after cyclic loading (1,000 cycles between 50 and 250 N) were then evaluated. RESULTS: All 8-mm grafts that were fixed with cross-pins failed after a mean of 124 cycles of load. The 9-mm and 10-mm grafts survived the cyclic loading protocol. Yield load and maximum load of the 10-mm groups (cross-pin and interference screw) were significantly higher than that of the 9-mm groups. There was no significant difference in maximum load, yield load, and stiffness between the cross-pin and interference screw fixation technique for 1 graft size. CONCLUSIONS: The biomechanical data suggest that femoral fixation of 9-mm and 10-mm BPTB grafts using 2.7-mm biodegradable cross-pins leads to primary stability that is comparable to that of biodegradable interference screws. Fixation of 8-mm BPTB grafts using 2.7-mm biodegradable cross-pins had poor results. CLINICAL RELEVANCE: The diameter of the bone block is the limiting factor for the final fixation strength and the cyclical survival when using cross-pins. We strongly recommend not using this technique for bone blocks smaller than 9 mm in diameter.

Absorbable Implants↗

Cyclic testing of flexible all-inside meniscus suture anchors: biomechanical analysis.

BACKGROUND: Flexible meniscus repair devices are designed to combine the benefits of rigid all-inside meniscus anchors with the biomechanical properties of sutures. HYPOTHESIS: Stiffness and pull-out strength of flexible all-inside suture anchors and conventional sutures under cyclic loading conditions will be comparable. STUDY DESIGN: Controlled laboratory study. METHODS: In 50 fresh frozen bovine menisci, artificial meniscus lesions were repaired with different meniscus fixation techniques: horizontal and vertical FasT-Fix, RapidLoc, and horizontal and vertical 2-0 Ethibond sutures. The specimens were cycled 1000 times between 5 and 20 N and then loaded to failure. RESULTS: All devices survived the cyclic loading protocol. There was no significant difference in the displacement between all repair techniques tested (horizontal FasT-Fix, 6.23 mm; vertical FasT-Fix, 5.34 mm; RapidLoc, 6.84 mm; horizontal 2-0 Ethibond, 6.03 mm; vertical 2-0 Ethibond, 5.61 mm (P > .05). Vertical and horizontal FasT-Fix suture anchors had a significantly higher stiffness and pull-out strength (94.1 N and 80.8 N, respectively) than did horizontal sutures (50.2 N) and RapidLoc devices (30.3 N) (P > .05). CONCLUSIONS: In this study, flexible all-inside meniscus anchors (FasT-Fix) had higher pull-out strength than did conventional vertical suture techniques. Biomechanical characteristics of the flexible RapidLoc are comparable to those of horizontal sutures. CLINICAL RELEVANCE: Flexible all-inside meniscus repair devices are an alternative to conventional suture techniques.

Animals↗

Soft-tissue graft fixation in posterior cruciate ligament reconstruction: evaluation of the effect of tibial insertion site on joint kinematics and in situ forces using a robotic/UFS testing system.

INTRODUCTION: Surgical reconstruction of the posterior cruciate ligament (PCL) is recommended in acute injuries that result in severe tibial subluxation and instability. The surgical outcome level may be affected by the tibial fixation site. In response to a 110-N posterior tibial load, kinematics and in situ forces of anatomical soft-tissue graft fixation in single-bundle PCL reconstruction using an interference screw fixation are significantly closer to those in the intact knee than with extracortical fixation with two staples. MATERIALS AND METHODS: Using a robotic/universal force moment sensor (UFS) testing system, we examined joint kinematics and in situ forces of porcine knees following single-bundle PCL reconstruction fixed at two different tibial fixation sites: anatomical interference screw and extracortical fixation. RESULTS: The site of the tibial graft fixation had significant effect on the resulting posterior displacement and in situ forces of the graft. Both PCL reconstruction techniques reduced the posterior tibial translation significantly. Proximal fixation techniques provided significantly less posterior tibial translation than extracortical fixation. Single-bundle PCL reconstruction with an interference screw showed higher in situ forces of the graft than the extracortical fixation. CONCLUSIONS: The kinematics and in situ forces of a single-bundle PCL reconstruction using an interference screw fixation technique are superior to the primary stability of an extracortical fixation with staples.

Animals↗

Biomechanical evaluation of a new cross-pin technique for the fixation of different sized bone-patellar tendon-bone grafts.

To overcome the disadvantages of interference-screw fixation of bone-patellar tendon-bone (BPTB) grafts, new fixation techniques for anterior cruciate ligament (ACL) grafts using biodegradable pins have been developed. The hypothesis of the present study was that cross-pin fixation techniques provide a primary stability that is comparable to that of interference screws. A biomechanical in vitro study was discussed. Human BPTB grafts of 8, 9 and 10 mm diameter were fixed in bovine knees with biodegradable cross pins (diameter: 2.0, 2.7 or 3.2 mm) or biodegradable interference screws. Stiffness and ultimate load were evaluated. For 9 and 10 mm BPTB grafts, no statistically significant difference in maximum load and stiffness was found between the four fixation techniques tested. For 8 mm bone blocks the maximum load of the 3.2 mm pins (274.2 N) was significantly lower than for the 2.0 mm pins (479.8 N) and the interference screws (504.0 N). Predominant failure mode in this group was bone-block fracture. Thicker grafts (9 and 10 mm) fixed with the 2.0 mm pins predominantly failed by implant fracture. Femoral fixation of 8, 9 and 10 mm BPTB grafts using cross pins leads to biomechanical properties that are comparable to biodegradable interference screws when tested by a single-cycle load to failure. Cross pins provide a rigid fixation for 9 and 10 mm BPTB grafts.

Absorbable Implants↗

Initial fixation strength of flexible all-inside meniscus suture anchors in comparison to conventional suture technique and rigid anchors: biomechanical evaluation of new meniscus refixation systems.

BACKGROUND: The newest generation of meniscus repair devices is designed to combine the benefits of the all-inside technique with the biomechanical properties of sutures. HYPOTHESIS: New flexible all-inside suture anchors have better fixation strength than rigid anchors, but there is no difference when compared to conventional horizontal and vertical mattress sutures. STUDY DESIGN: Controlled laboratory study. METHODS: In fresh-frozen bovine menisci, initial fixation strength, stiffness, and failure mode of different meniscus fixation techniques (FastT-Fix, RapidLoc, Meniscus Arrow, horizontal and vertical 2.0 Ethibond sutures) were evaluated in a computer-based materials testing machine at a rate of 12.5 mm/sec. RESULTS: The vertical and horizontal FastT-Fix suture anchors were the strongest devices with regard to pullout strength, with no significant difference compared to the vertical 2-0 Ethibond sutures. Horizontal sutures, Meniscus Arrow, and RapidLoc had significantly lower pullout strength. Vertical and horizontal FastT-Fix suture anchors showed significantly higher stiffness than the other devices. CONCLUSIONS: Biomechanical properties of flexible all-inside meniscus anchors (FastT-Fix) are comparable to conventional vertical suture techniques. Characteristics of the flexible RapidLoc are comparable to rigid anchors (Meniscus Arrow). CLINICAL RELEVANCE: From the biomechanical point of view, flexible all-inside meniscus refixation devices are an alternative to conventional suture techniques and rigid meniscus anchors.

Animals↗

A new rigid biodegradable anchor for meniscus refixation: biomechanical evaluation.

All-inside repair devices have been developed to overcome the disadvantages of conventional suture techniques (such as vein and nerve damage and increased OR time). The Contour Meniscus Arrow is a second generation of the first biodegradable all-inside implant, the Meniscus Arrow. The aim of this study was to compare the biomechanical properties of the Contour Meniscus Arrow to the first-generation Meniscus Arrow and vertical or horizontal suture techniques. In fresh frozen bovine menisci, initial fixation strength, stiffness and failure mode of four different meniscus refixation techniques (Meniscus Arrow, Contour Meniscus Arrow, vertical and horizontal 2-0 Ethibond suture techniques) were evaluated in a computer-based material-testing machine at a rate of 12.5 mm/s. Vertical meniscus sutures showed the highest initial fixation strength, followed by the horizontal suture technique and the Contour Arrow. The Meniscus Arrow showed inferior pull-out strength. Subjecting the different refixation techniques to cyclic testing decreased the fixation strength in all groups. The modified Meniscus Anchor (Contour Arrow) provides biomechanical properties that are superior (pull-out strength) or similar (stiffness) compared to the first biodegradable all-inside implant, the Meniscus Arrow. The pull-out strength of the Contour Arrow was comparable to the pull-out strength reported for horizontal meniscus sutures in the literature. These biomechanical characteristics of this new implant justify clinical use.

Absorbable Implants↗

Primary stability of bone-patellar tendon-bone graft fixation with biodegradable pins.

PURPOSE: We evaluated the initial bone-patellar tendon-bone (BPTB) graft fixation strength of biodegradable pins compared with interference screws in anterior cruciate ligament reconstruction using bovine knees. TYPE OF STUDY: Biomechanical in vitro study. METHODS: Ten BPTB grafts from human donors fixed with 2 biodegradable 2.7-mm pins (Rigid Fix; Ethicon, Mitek Division, Norderstedt, Germany) crossing the bone block perpendicular and 10 BPTB grafts fixed with conventional biodegradable interference screws (Absolute Absorbable Interference Screw; Innovasive Devices, Marlborough, MA) underwent ultimate single-cycle failure loading at a rate of 200 mm/min. The grafts were fixed to bovine tibia to simulate young human femoral bone density. Failure mode, displacement before failure, and ultimate failure load were tested with a testing machine. The pullout force was in line with the bone tunnel to simulate a worst case scenario. RESULTS: The failure mode for cross pins was either fracture of the bone block (5 specimens) or fracture of the articular pin (5 specimens). The failure mode for interference screws was slippage past the screw in all specimens. In the single cycle loading test, the mean yield load for the biodegradable pins was 400.2 (+/- 122.4) N, maximum load, 524.6 (+/- 136.6) N, with a mean stiffness of 155.2 (+/- 32.4) N/mm. The yield load at failure for the interference screw was 402.7 (+/- 143.9) N, maximum load 515.7 (+/- 168.5) N with a mean stiffness of 168 (+/- 42) N/mm. CONCLUSIONS: Fixation of a BPTB graft with 2 biodegradable 2.7-mm pins (Rigid Fix) leads to primary stability that is comparable to fixation with biodegradable interference screws.

Absorbable Implants↗