Search PubMed⌕ Search

Biomedical subjects

A N DeMaria

Publications and source records attributed to A N DeMaria.

At least 73 records · Page 4Linked to original sources

Managed care involvement by cardiovascular specialists: prevalence, attitudes and influence on practice.

OBJECTIVES: The purpose of this study was to determine the involvement in and attitudes toward managed care by cardiovascular specialists and the influence of such programs on their practices. BACKGROUND: No in-depth study has measured the impact of managed care on cardiovascular specialists. Therefore, we conducted a mail survey to determine the prevalence of managed care arrangements among cardiovascular specialists and variations among pediatric and adult cardiologists and cardiovascular surgeons; the types of managed care arrangements in which cardiovascular specialists are engaged; the reasons why those not participating in managed care have chosen not to do so; and the general attitudes among cardiovascular specialists with regard to various aspects of managed care. In addition, we evaluated the impact of managed care among several aspects of cardiovascular practice. METHODS: A questionnaire was mailed in the spring of 1993 to 4,577 practicing, domestic, American College of Cardiology (ACC) members selected at random from within each primary cardiovascular specialty group (adult cardiologists, pediatric cardiologists and cardiovascular surgeons). Additional data concerning practice characteristics were cross tabulated using results from the 1992 ACC membership profile survey. RESULTS: In total, 1,961 of the 4,577 members responded to the survey, representing a 43% response rate. Of all survey respondents, 76% reported entering into at least one relationship with a health maintenance organization (HMO) or preferred provider organization (PPO). Of those not participating in managed care arrangements, the most frequently mentioned reason was "concern over the quality of care." This reason was cited by 51% of those not entering into HMO relationships and 41% of those not participating in PPOs. The majority of respondents indicated that they do not strongly object to the gatekeeper approach to managing nonemergent patients, although more than half indicated concern that gatekeepers may not be appropriate in the management of cardiac emergencies. In addition, cardiovascular specialists report that under managed care, referrals have not increased, income has decreased, and managed care formularies have not substantially affected their ability to prescribe appropriate medication to their patients. CONCLUSIONS: Despite concerns over the quality of care and contract requirements and general philosophical opposition of cardiovascular specialists, most are becoming integrated into managed care environments.

Adult↗

A simplified method for determining regurgitant fraction by Doppler echocardiography in patients with aortic regurgitation.

OBJECTIVES: This study attempted to develop and validate a simple method for calculating aortic regurgitant fraction by use of pulsed wave Doppler echocardiography. BACKGROUND: Although several investigators have been able to determine aortic regurgitant fraction by Doppler echocardiography, the methods used require accurate determination of the cross-sectional areas of intracardiac sites at which the volumetric flow is calculated. METHODS: Our concept was based on a constant relation that exists between the cross-sectional area of the left ventricular outflow tract and the mitral valve annulus in normal subjects. To verify this, we used Doppler echocardiography to measure the flow velocity integral of the left ventricular outflow tract and the mitral annulus in the apical view in 50 normal subjects (32 men, 18 women, mean age 34 years). RESULTS: Close correlation (r = 0.95) was observed between the flow velocity integral (FVI) of the outflow tract (OT) and that of the mitral annulus (MA): FVIMA/FVIOT = 0.77. Because mitral flow equals aortic flow in normal subjects, the ratio of the cross-sectional area of the mitral annulus to that of the outflow tract was 1/0.77. In patients with aortic regurgitation, the regurgitant fraction (RF) = (Aortic flow-Mitral flow)/Aortic flow = 1-Mitral flow/Aortic flow. Substituting 0.77 for the area component of flow, RF = 1-(1/0.77).(FVIMA/FVIOT). To evaluate the accuracy of this method, we compared the regurgitant fraction derived by Doppler echocardiography with that from catheterization findings in 20 patients with aortic regurgitation (an isolated lesion was found in 14). The regurgitant fraction by catheterization was the difference between total (angiographic) and forward (thermodilution) stroke volumes as a percent of total flow. Good correlation was observed between catheterization and Doppler regurgitant fraction (r = 0.88, SEE 9%, p < 0.01). CONCLUSIONS: Thus, regurgitant fraction can be estimated from Doppler echocardiography in patients with aortic regurgitation by a method that requires only measurements of the flow velocity integral from the mitral annulus and left ventricular outflow tract.

Adult↗

Comparison of two- and three-dimensional echocardiography with cineventriculography for measurement of left ventricular volume in patients.

OBJECTIVES: We compared two- and three-dimensional echocardiography with cineventriculography for measurement of left ventricular volume in patients. BACKGROUND: Three-dimensional echocardiography has been shown to be highly accurate and superior to two-dimensional echocardiography in measuring left ventricular volume in vitro. However, there has been little comparison of the two methods in patients. METHODS: Two- and three-dimensional echocardiography were performed in 35 patients (mean age 48 years) 1 to 3 h before left ventricular cineventriculography. Three-dimensional echocardiography used an acoustic spatial locator to register image position. Volume was computed using a polyhedral surface reconstruction algorithm based on multiple nonparallel, unevenly spaced short-axis cross sections. Two-dimensional echocardiography used the apical biplane summation of disks method. Single-plane cineventriculographic volumes were calculated using the summation of disks algorithm. The methods were compared by linear regression and a limits of agreement analysis. For the latter, systematic error was assessed by the mean of the differences (cineventriculography minus echocardiography), and the limits of agreement were defined as +/- 2 SD from the mean difference. RESULTS: Three-dimensional echocardiographic volumes demonstrated excellent correlation (end-diastole r = 0.97; end-systole r = 0.98) with cineventriculography. Standard errors of the estimate were approximately half of those of two-dimensional echocardiography (end-diastole +/- 11.0 ml vs. +/- 21.5 ml; end-systole +/- 10.2 ml vs. +/- 17.0 ml). By limits of agreement analysis the end-diastolic mean differences for two- and three-dimensional echocardiography were 21.1 and 12.9 ml, respectively. The limits of agreement (+/- 2 SD) were +/- 54.0 and +/- 24.8 ml, respectively. For end-systole, comparable improvement was obtained by three-dimensional echocardiography. Results for ejection fraction by the two methods were similar. CONCLUSIONS: Three-dimensional echocardiography correlates highly with cineventriculography for estimation of ventricular volumes in patients and has approximately half the variability of two-dimensional echocardiography for these measurements. On the basis of this study, three-dimensional echocardiography is the preferred echocardiographic technique for measurement of ventricular volume. Three-dimensional echocardiography is equivalent to two-dimensional echocardiography for measuring ejection fraction.

Adult↗

Three-dimensional echocardiographic measurement of left ventricular volume in vitro: comparison with two-dimensional echocardiography and cineventriculography.

OBJECTIVES: This study was designed to compare three-dimensional echocardiography, two-dimensional echocardiography and cineventriculography for the purpose of measuring left ventricular volume in vitro. BACKGROUND: Three-dimensional echocardiographic systems have been shown to be highly accurate in measuring the volumes of balloon phantoms. However, three-dimensional techniques have not been compared with standard two-dimensional echocardiography in vitro or with cineventriculography, the clinical standard for left ventricular volume measurement. METHODS: Excised porcine hearts were prepared with an internal latex sheath that could be filled and maintained with a known ("true") volume of liquid. Each heart was then imaged by cineventriculography, standard two-dimensional echocardiography and three-dimensional echocardiography. Left ventricular volumes were calculated from 15 hearts at 25 volumes ranging from 50 to 280 ml by the following methods: 1) biplane cineventriculography using the area-length method; 2) two-dimensional echocardiography by the apical biplane method using a summation of discs algorithm in 15 cases and the single-plane, four-chamber method using a summation of discs algorithm in 10 cases; and 3) three-dimensional echocardiography using a polyhedral surface reconstruction volume computation algorithm based on multiple nonparallel, nonevenly spaced short-axis cross sections. RESULTS: Results were compared with true volume, and a nonparametric analysis of variance was performed. Both measurement bias (systematic error) and imprecision (random error) were assessed. All methods tended to underestimate the true volume (two-dimensional echocardiography -6.1 +/- 17.6%, three-dimensional echocardiography -4.7 +/- 5.0% and biplane cineventriculography -3.9 +/- 8.2%), although differences were not significant. Although there was a significant correlation between the magnitude of measurement bias and the size of the volume being measured for two-dimensional echocardiography and cineventriculography, the bias of three-dimensional echocardiography was fairly constant over the range of volumes. When bias was accounted for, two-dimensional echocardiography was significantly less precise than cineventriculography and three-dimensional echocardiography in terms of percent error (15.3 +/- 11.9%, 5.6 +/- 5.7% and 3.9 +/- 3.4%, respectively). CONCLUSIONS: Three-dimensional echocardiography using a polyhedral surface reconstruction algorithm for volume computation provides accuracy comparable to that of biplane cineventriculography in this in vitro model. Standard two-dimensional echocardiographic volume computation is significantly less accurate than the other two methods.

Algorithms↗

Contrast echocardiography for evaluation of left ventricular flow dynamics using densitometric analysis.

BACKGROUND: Few data exist regarding intraventricular flow patterns in the presence of left ventricular dysfunction. Therefore, we examined the relation between intracavitary left ventricular flow dynamics and the presence of ventricular contractile abnormalities using videodensitometric analysis of transpulmonary contrast echocardiography. METHODS AND RESULTS: Two-dimensional echocardiography was performed before, during, and after intravenous injection of sonicated albumin in 8 normal subjects, 22 patients with infarction, and 6 patients with dilated cardiomyopathy. Time-intensity curves were recorded, and disappearance half-times (in cardiac cycles) were measured for regions of interest at the mitral orifice (Ta) and mid-left ventricular cavity (Tb). We observed contrast enhancement of the left ventricular cavity in 28 of 36 patients. Ta and Tb were identical (19 beats) in all normal patients, but Tb was greater than Ta (19 versus 22 beats, P < .001) in patients with dyssynergy. Patients with dyssynergy were divided in three groups: group A, in whom Tb-Ta < or = 3; group B, in whom Tb-Ta > or = 4; and group C, which was composed of patients without contrast enhancement. Left ventricular end-diastolic dimension was similar in normal patients (46.1 mm) and group A patients (50.3 mm) but was less in each cohort than in groups B (58.7 mm) and C (64.1 mm) (all P < .01). Significant correlation was observed between Tb-Ta and both ejection fraction (r = -.67, P < .001) and wall motion index (r = .62, P < .001). CONCLUSIONS: Clearance of contrast from the mid-left ventricular cavity is prolonged in patients with left ventricular dysfunction. This prolongation may be related to increased left ventricular diastolic volume, impaired intracavitary mixing, or paradoxical systolic flow. Delayed left ventricular contrast washout may have implications regarding the formation of left ventricular thrombi.

Adult↗

Myocardial washout of sonicated iopamidol reflects coronary blood flow in the absence of autoregulation.

OBJECTIVES: The aim of the study was to evaluate the relation between measurements derived from myocardial contrast echocardiography and coronary blood flow. BACKGROUND: Contrast echocardiography has the potential for measuring blood flow. METHODS: In six open chest anesthetized dogs, the left circumflex coronary artery was cannulated and perfused with blood drawn from the left femoral artery. While adenosine was infused into the circuit, circumflex flow was generated by a calibrated roller pump to the point of abolishing coronary autoregulation. At each of 25 levels of coronary blood flow, paired bolus injections of sonicated iopamidol were performed proximal to a mixing chamber. The perfused area of the left circumflex coronary artery was labeled by radioactive microspheres injected into the perfusion line. Two-dimensional echocardiographic images of the left ventricular short axis were digitized off-line, and myocardial videodensity was measured in the area perfused by the left circumflex coronary artery to generate time-intensity curves. RESULTS: The washout slope of curves showed a good correlation with coronary blood flow, ranging from 0.5 to 12.5 ml/min per g of tissue. This correlation was good both in individual dogs (correlation coefficient [r] ranging from 0.78 to 0.96) and in the group of animals as a whole (r = 0.85). Washout slope also showed a good correlation with coronary diastolic pressure (r = 0.80), which ranged from 23 to 114 mm Hg, suggesting a possible primary effect of pressure on contrast washout. However, coronary blood flow appeared to be a stronger predictor of washout slope (partial F = 26.5, p < 0.001) than did perfusion pressure (partial F = 5.9, p < 0.05 by multiple regression). The injection to injection variability in myocardial washout slope appeared to be high (24%). The gamma variate fitting of curves did not improve the correlation with coronary flow (r = 0.78). CONCLUSIONS: Myocardial washout of sonicated iopamidol reflects coronary blood flow in a model in which coronary autoregulation is abolished.

Adenosine↗

Improved reproducibility of left atrial and left ventricular measurements by guided three-dimensional echocardiography.

OBJECTIVES: The objective of this study was to determine whether guided three-dimensional echocardiography could improve the reproducibility of left atrial and left ventricular anteroposterior measurements over that of standard unguided two-dimensional echocardiography. BACKGROUND: Although these measurements are standard indexes for evaluating chamber size, their use is limited by significant interobserver variability largely due to variable image plane positioning. To improve measurement accuracy and reproducibility, we have developed a three-dimensional echocardiograph that displays the line of intersection of the real-time image with a previously saved orthogonal reference image. This display shows the relation of the real-time image to anatomic landmarks in its third, nonvisualized dimension and may be used to guide image positioning. METHODS: Three pairs of operators independently performed unguided two-dimensional and guided three-dimensional examinations on three groups of 10 patients each. The left atrium was measured in a plane through the inferior surface of the aortic cusps and the left ventricle in a plane perpendicular to its long axis 1 cm below the mitral leaflet tips. Interobserver variability of these measurements on unguided parasternal long-axis images and on guided short-axis images was assessed. RESULTS: The standard unguided two-dimensional examination was associated with an interobserver variability of 14.6% and 9.1% for atrial and ventricular measurements, respectively. Guided three-dimensional echocardiography significantly reduced interobserver variability to 5.0% and 3.1%, respectively, for the same measurements (p < 0.005 by McNemar's test). CONCLUSIONS: Significant interobserver variability occurs with standard unguided two-dimensional echocardiographic measurement of left atrial and left ventricular dimensions. Guided three-dimensional echocardiography achieves a nearly threefold improvement of reproducibility of these measurements and provides the basis for improved serial evaluation and comparison of atrial and ventricular size by different operators.

Adult↗

Intravascular ultrasound of the coronary arteries: current applications and future directions.

Although angiography is widely applied in the diagnosis of the coronary artery disease (CAD), studies have questioned the accuracy of radiographic methods. Miniaturized intravascular ultrasound devices offer several potential advantages, including a tomographic orientation and the ability to characterize atherosclerotic plaques. Two dissimilar technical approaches to transducer design have emerged: mechanically rotated devices and multi-element arrays, each yielding small coronary catheters (1.1-1.8 mm in diameter). Initial studies of coronary ultrasound have demonstrated few serious untoward effects. In most normal subjects, the vessel wall is laminar in appearance with an intimal leading edge and subintimal sonolucent layer averaging less than or equal to 0.20 mm in thickness. In most CAD patients, the thickness of the leading-edge or sonolucent zone is abnormally increased. Atherosclerotic abnormalities are frequently evident in segments with no angiographic lesion. At sites with a circular lumen shape, minimum diameter by ultrasound and angiography correlate closely, r = 0.93. At sites with an eccentric lumen, significant disagreement between angiography and ultrasound diameter is evident, r = 0.78. Correlation between angiography and ultrasound from percent stenosis is moderate, r = 0.63. Following balloon angioplasty percutaneous transluminal coronary angioplasty (PTCA), morphologic findings include complex cracks, splits, and dissections, and minimum lumen diameter by angiography and intravascular ultrasound correlate poorly. Recent advances have improved the utility of coronary ultrasound, including smaller catheters and a device combining a miniature imaging transducer (1.16 mm) with a low profile balloon (0.028-0.033 inch). Important current limitations include inability to visualize the smallest coronaries and tight stensoses. The future of coronary ultrasound is promising, propelled by the unique capability of this modality to image atherosclerotic plaques directly.

Coronary Artery Disease↗

Discordance between responses of contrast echo intensity to increased flow rate in human coronary circulation and in vitro.

According to the Stewart-Hamilton equation flow is inversely related to the area under the time-concentration curve produced by the transit of a detectable indicator. To verify the applicability of this principle for contrast echocardiography, we bolus injected a saccharide echo contrast agent (0.8 ml) into an in vitro circulatory model at variable flow rates. Two-dimensional echo images were digitized, and curves demonstrating the ratio of videointensity over time were derived. As expected, flow was inversely related to the area under the curves (r = 0.93). To apply this principle to human coronary circulation, we bolus injected sonicated iopamidol (4 ml) into the normal left coronary artery of six patients at baseline and after intravenous administration of dipyridamole (0.84 mg/kg in 10 minutes). Echo images were digitized, and myocardial time-intensity curves were derived. The area under the curve after dipyridamole administration (210 +/- 128 gray level.sec) did not appear significantly different from that at baseline (177 +/- 80 gray level.sec). Thus a mismatch exists between contrast echo data obtained in vitro and in human coronary circulation.

Aged↗

Comparison of gray-scale and B-color ultrasound images in evaluating left ventricular systolic function in coronary artery disease.

To confirm whether or not echocardiographic B-color images (temperature, magenta, rainbow) are superior to ordinary gray-scale images, 62 coronary artery disease (CAD) patients (42 men and 20 women) underwent gray-scale and B-color echocardiography and cineangiography within 24 hours. Left ventricular (LV) volume was derived from angiography using the single-plane area-length method and was derived from echocardiography using single-plane modified Simpson's formula. In predicting angiographic volume, the correlations between B-color images and angiography were similar to that between the gray-scale image and angiography. In evaluating LV ejection fraction, the correlation coefficients between B-color images and angiography (temperature r = 0.93, magenta r = 0.93, rainbow r = 0.92) were slightly higher than that between the gray-scale image and angiography (r = 0.85) (p less than 0.05). We conclude that B-color images yield estimates of LV volumes that are of similar accuracy to gray-scale images in patients with CAD.

Cineangiography↗

Temporal variability of color Doppler jet areas in patients with mitral and aortic regurgitation.

The temporal variability of color flow jets during regurgitation has not been systematically examined. We therefore analyzed color Doppler images in 52 patients (29 with mitral regurgitation and 23 with aortic regurgitation) for frame-to-frame variability in the size of the regurgitant color jet. Planimetered jet areas varied markedly throughout the flow period, with the difference between the largest and smallest mitral regurgitant jets ranging from 1.1 to 11.9 cm2 in individual patients. Maximal and minimal aortic regurgitant jets varied from 1.5 to 6.6 cm2 between frames. The point during the cardiac cycle at which the largest regurgitant jet area was recorded also varied markedly for mitral and aortic lesions. Mitral regurgitant jets peaked at 51% of systole, with a range from 9% to 100%. The point during diastole at which the maximal aortic regurgitant jet was recorded varied from 2% to 84%, with a mean of 31.2% of the diastolic period. The persistence of the flow disturbance was examined as the percent of systole or diastole during which the maximal jet area remained at least 50% or 75% of its maximal size. Mitral regurgitant jets remained at least one-half maximal size for a mean of 60.7% (range, 20% to 90%) of systole, but remained at 75% of maximal size for a mean of only 39% of systole. Aortic regurgitant jets persisted at over one-half maximal size for a mean of 63.2% (range, 30% to 90%) of diastole, but sustained 75% of maximal size for a mean of only 44% of diastole.(ABSTRACT TRUNCATED AT 250 WORDS)

Aortic Valve↗

Value and limitations of transesophageal echocardiography in determination of left ventricular volumes and ejection fraction.

Several formulas exist for estimating left ventricular volumes and ejection fraction using conventional two-dimensional echocardiography from transthoracic views. Transesophageal imaging provides superior resolution of endocardial borders but employs slightly different scan planes. The estimation of left ventricular volumes by transesophageal echocardiography has not been validated in human patients. Therefore, the purpose of this study was to compare left ventricular volumes and ejection fraction derived from transesophageal short-axis and four-chamber images with similar variables obtained from ventriculography. End-diastolic and end-systolic volumes and ejection fraction were calculated using modified Simpson's rule, area-length and diameter-length models in 36 patients undergoing left ventriculography. Measurements of left ventricular length were obtained from the transesophageal four-chamber view and areas and diameters were taken from short-axis scans at the mitral valve, papillary muscle and apex levels. Data from transesophageal echocardiographic calculations were compared with end-diastolic volume (mean 172 +/- 90 ml), end-systolic volume (mean 91 +/- 74 ml) and ejection fraction (mean 52 +/- 15%) from cineventriculography using linear regression analysis. The area-length method (r = 0.88) resulted in a slightly better correlation with left ventricular end-diastolic volume than did Simpson's rule (r = 0.85) or area-length (r = 0.84) formulas. For end-systolic volume, the three models yielded similar correlations: Simpson's rule (r = 0.94), area-length (r = 0.93) and diameter-length (r = 0.95). Each of the methods resulted in significant underestimation of diastolic and systolic volumes compared with values assessed with angiography (p less than 0.003). Ejection fraction was best predicted by using the Simpson's rule formula (r = 0.85) in comparison with area-length (r = 0.80) or diameter-length (r = 0.73) formulas. Measurements of left ventricular length by transesophageal echocardiography were smaller for systole (mean 5.7 +/- 1.6 cm) and diastole (mean 7.7 +/- 1.2 cm) than values by ventriculography (mean 9.2 +/- 1.4 and 8.1 +/- 1.6 cm, respectively; p less than 0.0001), suggesting that underestimation of the ventricular length is a major factor contributing to the smaller volumes obtained by transesophageal echocardiography. In conclusion, currently existing formulas can be applied to transesophageal images for predicting left ventricular volumes and ejection fraction. However, volumes obtained by these models are significantly smaller than those obtained with angiography, possibly because of foreshortening in the transesophageal four-chamber view.

Adult↗

Influence of operator- and patient-dependent variables on the suitability of automated quantitative coronary arteriography for routine clinical use.

This study was designed to elucidate the operator- and patient-dependent variables inherent in clinical application of quantitative coronary arteriography. Digital arteriograms from 25 consecutive patients undergoing diagnostic catheterization were analyzed by four experienced angiographers utilizing an automated coronary edge detection system to measure percent area stenosis. The identification of potentially significant lesions for quantitation constituted a major source of variability, with unanimous agreement on the presence of a greater than or equal to 50% stenosis occurring at 38 (29%) of the 130 reported sites. Selection of an optimal frame for quantitative analysis resulted in disagreement for every lesion reported. Frame selection by the operator, as opposed to measurement of preselected frames, increased the interobserver variability from 5% to 7% for automated geometric analysis (p less than 0.01), and from 8% to 10.5% for automated densitometric analysis (p less than 0.01). Fully automatic arterial border detection was possible for only 20 (52.5%) of the 38 unanimously identified stenoses. The 18 failures involved one or more of the following factors: 1) stenosis at a bifurcation (13 [72%]); 2) diffuse, severe disease (8 [44%]); 3) excessive vessel tortuosity or overlap or both (4 [22%]); and 4) poor image quality (5 [28%]). In contrast, the same automated border detection algorithm successfully traced all 15 preselected frames of discrete stenoses referred for coronary angioplasty. Automated quantitative coronary arteriography performs well when carefully selected, discrete stenoses are presented to the computer for analysis. However, quantitative analysis of routine clinical coronary arteriograms is limited by operator-dependent variability in stenosis identification and frame selection, as well as by complex coronary anatomy and suboptimal image quality. These limitations make automated quantitative coronary arteriography impractical for routine clinical use.

Adult↗

Age and propranolol stereoselective disposition in humans.

The apparent oral clearance of S(-)- and R(+)-propranolol as a function of age was evaluated in 53 healthy male volunteers (age range, 21 to 84 years) after a single 40 mg oral dose of the racemic mixture. No significant age-associated change in the total (bound plus unbound) and unbound S(-) and R(+) apparent oral clearance was observed (p greater than 0.05). Stereoselectivity in apparent oral clearance (both total and unbound) remained unaffected by advancing age (p greater than 0.05). The relationship between age and propranolol enantiomer plasma protein binding was also evaluated in 70 subjects, 53 of whom were from this study (age range, 21 to 89 years). Plasma free fractions for S(-)- and R(+)-propranolol were unchanged with increasing age (p greater than 0.05), even though the binding was stereoselective (plasma free fractions for R(+) greater than plasma free fractions for S(-); p less than 0.05). The findings from this relatively large and extensive study indicate that age does not influence the stereoselective disposition of propranolol.

Administration, Oral↗