Search PubMed⌕ Search

Biomedical subjects

A N DeMaria

Publications and source records attributed to A N DeMaria.

At least 55 records · Page 3Linked to original sources

Atheroma morphology and distribution in proximal left anterior descending coronary artery: in vivo observations.

OBJECTIVES: This study sought to examine, in vivo, the shape and position of atheroma in the proximal left anterior descending coronary artery. BACKGROUND: The prevalence, shape and location of atheromas involving the proximal left anterior descending artery have implications regarding the role of disturbed shear forces in the genesis of atherosclerosis. However, no data are available regarding in vivo findings or advanced disease. METHODS: Forty-two consecutive high quality intravascular ultrasound images were examined from patients with atherosclerotic disease in the proximal left anterior descending artery just distal to the left main bifurcation. Lesion percent area stenosis and maximal, minimal and flow divider intimal-medial thickness were measured at the region immediately after the circumflex takeoff. The angle formed by the midpoint of the flow divider, the human center of gravity and the maximal plaque thickness were determined. RESULTS: Eccentricity of vessel wall atheroma was observed such that the maximal wall thickness (1.42 +/- 0.50 mm [mean +/- SD]) differed significantly from minimal wall thickness (0.17 +/- 0.098 mm). Further, the region of vessel wall manifesting maximal thickness was greater than the flow divider thickness (0.26 +/- 0.16 mm). Maximal plaque thickness spared the region of the flow divider in 100% of cases and was positioned at a mean angle of 193 +/- 49 degrees from the center of the flow divider. Eccentric morphology was maintained across the 24% to 80% range of area stenosis. CONCLUSIONS: Atheromas in the very proximal left anterior descending artery are located opposite the circumflex takeoff, spare the flow divider and maintain eccentricity across a wide range of vessel stenoses. These in vivo morphologic data support the potential role of fluid dynamic mechanical factors in atherogenesis and have implications regarding the success of catheter-based interventional procedures at the site.

Adult↗

Comparative efficacy of short-term intravenous infusions of milrinone and dobutamine in acute congestive heart failure following acute myocardial infarction. Milrinone-Dobutamine Study Group.

The purpose of this study was to compare the hemodynamic and clinical effects of milrinone, a vasodilating and positive inotropic agent, with those of dobutamine in patients with congestive heart failure (CHF) following acute myocardial infarction (AMI). Thirty-three patients in Killip classification II or III within 12 h to 5 days after AMI were randomized in a multicenter, open-label clinical trial to receive a 24-h infusion of milrinone or dobutamine. Drugs were titrated to achieve at least a 30% increase in cardiac index (CI) from mean baseline or at least a 25% decrease in mean pulmonary capillary wedge pressure (MPCWP) from baseline. Both drugs improved CI, MPCWP, and other hemodynamic parameters. Criteria for decrease in MPCWP were met by 94% (15/16) of the milrinone-treated patients and 57% (8/14) of dobutamine-treated patients (p = 0.03). Both groups met the minimum efficacy criterion for CI. Maximal reduction in MPCWP over 0-3 h was greater in the milrinone group (-53.2%) than in the dobutamine group (-31.0%; p < or = 0.01); reductions were sustained over 24 h. Both drugs improved echocardiographic global ejection fraction and were generally well tolerated. The short-term infusion of milrinone may have a role in the management of CHF following AMI, especially when the aim is the rapid reduction of pulmonary congestion.

Acute Disease↗

Differential responses in left ventricular diastolic filling dynamics with isometric handgrip versus isotonic treadmill exertion.

Although the hemodynamic responses to isotonic and isometric exercise are different, few data exist comparing the response to left ventricular (LV) diastolic filling dynamics with these two forms of exertion. Therefore we performed Doppler examination before and at the end of isotonic and isometric exercise in 20 normal volunteers to define the differential responses of LV filling to these two forms of exertion. Transmitral inflow velocity signals from the apical view and phonocardiography were recorded before and at the termination of treadmill exercise (TRD) to 11 METs and handgrip (HG) 50% maximal for 2 minutes). Mean blood pressure (mBP), heart rate (HR), early diastolic (E) and late atrial (A) inflow velocities, mean acceleration rate (ACC) of E wave, time velocity integral of inflow (Ti), and isovolumic relaxation time (IRT) from second heart sound to onset mitral inflow were measured. Absolute changes from baseline were significantly different for the two forms of exertion: TRD versus HG: BP = 11 +/- 9 versus 36 +/- 10 mm Hg, HR = 37 +/- 16 versus 16 +/- 9 beats/min, E = 11.6 +/- 11.3 versus -7.0 +/- 9.4 cm/sec, A = 29.9 +/- 14.5 versus 14 +/- 12 cm/sec, ACC = 164 +/- 151 versus -56 +/- 135 cm/sec2, Ti = 1.9 +/- 3.0 versus -1.7 +/- 1.7 cm, and IRT = -12 +/- 9 versus 9 +/- 10 msec, all p < 0.0001 except for A, p < 0.001). Isotonic treadmill exercise resulted in enhanced early diastolic filling manifested by increases in E and ACC and a decreased in IRT. Conversely, isometric handgrip exercise produced evidence of reduced early filling including decreased E and ACC and slightly increased IRT. Thus the response of LV filling dynamics recorded by Doppler differs for isotonic and isometric exertion and likely reflects the variable pressure and flow alterations induced by these two forms of exertion.

Adult↗

Relation of Doppler transmitral flow patterns to functional status in congestive heart failure.

We analyzed the relation of Doppler transmitral flow patterns and New York Heart Association (NYHA) classification in 60 consecutive patients with heart failure (44 men and 16 women; mean age 58 +/- 13 years) with left ventricular ejection fraction of < 40 percent. Of the study population, 40 patients with mild to moderate heart failure underwent symptom-limited exercise testing. The relation of transmitral flow pattern and exercise tolerance was also analyzed. Doppler echocardiography was performed in all patients. The patients were subdivided into nonrestrictive and restrictive groups according to the pattern. The univariate analysis showed a relation for left ventricular ejection fraction (p = 0.01 by analysis of variance testing) and transmitral flow pattern (p = 0.0003 by chi-squared test) with NYHA classification. When the multivariate regression analysis was performed, only the restrictive pattern by Doppler emerged as an independent determinant of the advanced NYHA class (p = 0.005). In mild to moderate congestive heart failure, patients with nonrestrictive pattern exercised significantly longer than those with the restrictive pattern by an average of 133 seconds (p = 0.003) despite comparable reductions in ejection fraction. Thus the restrictive transmitral flow pattern by Doppler is a noninvasive marker for severe symptoms and diminished exercise tolerance in heart failure patients.

Aged↗

Distortion of intravascular ultrasound images because of nonuniform angular velocity of mechanical-type transducers.

The purpose of this study was to quantify nonuniform rotation in a current mechanical intravascular ultrasound (IVUS) instrument and its effect on arc, area, and diameter measurements. The accurate reconstruction of IVUS two-dimensional images is dependent on uniform rotation of the catheter tip. Prior investigations suggested that bends in the catheter driveshaft may be responsible for poor torque transmission, nonuniform rotation, and consequent errors in IVUS measurements. Eight 30 MHz mechanically driven IVUS catheters were evaluated in a model simulating the catheter course through the aorta and coronary ostium in a clinical study. Angular velocity and posi-ion profiles of the transducer, image angle, and diameter and area measurement errors were obtained from each catheter by imaging a vascular phantom with eight equispaced echogenic markers from concentric and eccentric positions. Six catheters also were tested for comparison in a simple curvature model. Rotational error was found in all catheters tested and worsened in the aortic model. Maximal angular error, defined as the largest angle between actual and presumed transducer direction, increased when measured in the aortic model as compared with the simple curvature model (17 +/- 12 degrees to 45 +/- 25 degrees; p < 0.05). Angles of 45 degrees were misrepresented with a mean range of values of 26 to 63 degrees. With eccentric catheter placement, area and diameters had average maximal absolute errors of 26% +/- 7.8% and 23% +/- 10%, respectively. In conclusion, nonuniform rotation of mechanical IVUS transducers constitutes a significant potential source of error in IVUS measurement of arcs of calcification, and lumen shape, area, and diameter.

Humans↗

Effect of managed care on cardiovascular specialists: involvement, attitudes and practice adaptations.

OBJECTIVES: This study was undertaken to determine the extent to which cardiovascular specialists are involved with and affected by managed care and to ascertain their attitudes toward it. This survey also served as the follow-up to an initial study on the subject performed by the American College of Cardiology in 1993. BACKGROUND: The initial 1993 study was performed to address the lack of any comprehensive examination of the impact of managed care on cardiovascular specialists. In 1995, to reexplore this question and follow up the 1993 findings, the College conducted a survey of its membership in the following areas: 1) physician relationship with managed care plans; 2) number of managed care contracts; 3) breakdown of revenue by payment source; 4) changes in practice in response to managed care; and 5) physician attitudes toward managed care. To the extent feasible, the 1995 questionnaire paralleled the 1993 instrument to facilitate comparisons. METHODS: A questionnaire was mailed to 5,147 practicing College members in the United States, who were categorized by specialty as pediatric cardiologists, adult cardiologists or cardiovascular surgeons. Mailings were sent to 1) all pediatric cardiologists and cardiovascular surgeons; 2) randomly selected adult cardiologists practicing in 10 states with high managed care penetration; and 3) randomly selected adult cardiologists in the nine U.S. census areas who were not practicing in the 10 states with high managed care penetration. RESULTS: Usable surveys were returned by 1,236 respondents, for an overall response rate of 24%. Involvement with at least one type of managed care organization was reported by 89% of respondents, up from 76% in 1993. Although managed care relationships had increased across physician age, region, practice and specialty, respondents indicated that, on average, well below 50% of their practice revenues stem from managed care contracts. To adapt to the managed care environment, strategic practice changes, such as joining a cardiovascular network, implementing continuous quality improvement systems and adopting clinical pathways, were being instituted by most respondent practices of nine or more physicians. Smaller groups were less active. Most respondents involved with managed care disliked its effects, particularly in clinical matters. Their attitudes toward the assumption of risk, managed fee-for-service arrangements and a private versus single-payer system show that there is no uniformity of opinion regarding the best means to contain costs and promote efficiency. CONCLUSIONS: Managed care has become an established part of cardiovascular specialist practice in the United States. Although this trend is viewed with some disfavor, most respondents are making practice changes to adapt to this new environment.

Attitude of Health Personnel↗

Intracoronary gene transfer of fibroblast growth factor-5 increases blood flow and contractile function in an ischemic region of the heart.

Increased coronary blood vessel development could potentially benefit patients with ischemic heart disease. In a model of stress-induced myocardial ischemia, intracoronary injection of a recombinant adenovirus expressing human fibroblast growth factor-5 (FGF-5) resulted in messenger RNA and protein expression of the transferred gene. Two weeks after gene transfer, regional abnormalities in stress-induced function and blood flow were improved, effects that persisted for 12 weeks. Improved blood flow and function were associated with evidence of angiogenesis. This report documents, for the first time, successful amelioration of abnormalities in myocardial blood flow and function following in vivo gene transfer.

Adenoviruses, Human↗

Arterial compliance by cuff sphygmomanometer. Application to hypertension and early changes in subjects at genetic risk.

Abnormalities of the arterial pulse waveform reflect changes in cardiovascular structure and function. These abnormalities may occur early in the course of essential hypertension, even before the onset of blood pressure elevation. Previous studies of cardiovascular structure and function have relied on invasive intra-arterial cannulation to obtain the arterial pulse wave. We evaluated arterial structure and function using a noninvasive cuff sphygmomanometer in hypertensive (n = 15) and normotensive (n = 36) subjects stratified by genetic risk (family history) for hypertension. Using a simple physical model in which the aorta was assumed to be a T tube and the brachial artery a straight tube, we determined vascular compliance and peripheral resistance by analyzing the brachial artery pulsation signal from a cuff sphygmomanometer. Essential hypertensive subjects tended to have higher peripheral resistance (P = .06) and significantly lower vascular compliance (P = .001) than normotensive subjects. Vascular compliance correlated with simultaneously determined pulse pressure in both groups (n = 51, r = .74, P < .0001). Higher peripheral resistance (P = .07) and lower vascular compliance (P = .04) were already found in still-normotensive offspring of hypertensive parents (ie, normotensive subjects with a positive family history of hypertension) than in normotensive subjects with a negative family history of hypertension. Multivariate analysis demonstrated that both genetic risk for hypertension (P = .030) and blood pressure status (P = .041), although not age (P = .207), were significant predictors of vascular compliance (multiple R = .47, P = .011). However, by two-way ANOVA, genetic risk for hypertension was an even more significant determinant (F = 7.84, P = .007) of compliance than blood pressure status (F = 2.69, P = .089). Antihypertensive therapy with angiotensin-converting enzyme inhibitors (10 days, n = 10) improved vascular compliance (P = .02) and reduced resistance (P = .003) significantly; treatment with calcium channel antagonists (4 weeks, n = 8) tended to improve vascular compliance (P = .07) and significantly reduced peripheral resistance (P = .006). We conclude that arterial vascular compliance abnormalities detected by a noninvasive cuff sphygmomanometer reflect treatment-reversible changes in vascular structure and function. Early changes in vascular compliance in still-normotensive individuals at genetic risk for hypertension may be a heritable pathogenetic feature of this disorder.

Adult↗

Detection of regional left ventricular dysfunction in early pacing-induced heart failure using ultrasonic integrated backscatter.

BACKGROUND: It has been demonstrated that cyclic variation of ultrasonic integrated backscatter (CVIBS) may be useful in detecting altered physical conditions in the heart. However, no previous study has examined serial changes of CVIBS in the myocardium during the development of left ventricular dysfunction. METHODS AND RESULTS: We examined alterations of CVIBS in pacing-induced cardiac dysfunction. Eight pigs (36 +/- 2 kg) were studied before and sequentially during sustained rapid ventricular pacing (225 +/- 9 beats per minute). CVIBS was measured in the IVS and left ventricular PLW before pacing and daily for 4 days after onset of pacing. Five additional pigs (35 +/- 10 kg) were examined after 14 days of pacing. Regional function and CVIBS were assessed with pacemakers inactivated. A quantitative integrated backscatter imaging system (two-dimensional format) was used. Over 4 days of pacing, the magnitude of CVIBS progressively decreased in the PLW but was unchanged in the IVS, findings that persisted at 14 days. Percent wall thickening in the PLW progressively decreased to a greater degree than percent wall thickening in the IVS. A linear relation between the magnitude of CVIBS and percent wall thickening was found. At 14 days, blood flow to the two regions was similar but regional differences in CVIBS persisted. CONCLUSIONS: Rapid left ventricular pacing produces abnormalities of regional myocardial function within 48 hours of pacing. Regional myocardial dysfunction is accompanied by a reduction in CVIBS in the same region.

Animals↗

Effects of pulmonary venous flow direction on mitral regurgitation jet area as imaged by color Doppler flow mapping. An in vitro study.

BACKGROUND: Although the effects of adjacent walls and left atrial pressure on mitral regurgitation (MR) jet area imaged by color Doppler have been examined, few data exist regarding the influence of pulmonary venous (PV) filling flow on regurgitant jets. Therefore, we designed a left atrial model to examine the relation between PV flow direction and MR jet area. METHODS AND RESULTS: The left atrial chamber (7.6 cm in diameter) was built with a PV inflow (1.0 cm in diameter) and mitral valve regurgitant orifice in the same plane. The MR jet was simulated as fixed in volume and velocity (3.5 m/s) and directed with a pulsatile pump into the left atrial model. PV flow with a constant velocity (30 cm/s) was driven by gravity (83 cm H2O). With left atrial mean pressure at either 10, 30, or 50 mm Hg, four flow patterns were examined: (1) PV flow away from the mitral valve, MR jet toward the pulmonary vein; (2) PV flow toward the mitral valve, MR jet toward the pulmonary vein; (3) PV flow away from the mitral valve, MR jet away from the pulmonary vein; and (4) PV flow toward the mitral valve, MR jet away from the pulmonary vein. MR color Doppler images were recorded with a 3.5-mHz frequency transducer and at 7-kHz pulse repetition frequency. For each condition, we compared jet area, length, and width of the MR signal. MR jet areas for conditions 3 and 4 were larger at 10 mm Hg than at 30 or 50 mm Hg left atrial pressure. Especially at the lower pressures, PV flow diminished the MR jet area in condition 4 compared with that in condition 3, such that MR jets were smaller in condition 4. In conditions 1 and 2, the jets were imaged at an oblique angle and were smaller than in conditions 3 and 4 (P < .001), but they were not significantly different from each other as imaged. CONCLUSIONS: In this model, factors including the direction of PV flow, the direction of MR as relates to the angle of interrogation, and the level of left atrial pressure influenced the size of MR jets. The effect of PV flow direction was diminished by increased left atrial pressure. PV flow directed away from the mitral valve was associated with larger MR jets than when PV flow was directed toward it (condition 4), probably because of jet distortion and flattening.

Blood Flow Velocity↗

Subintimal wire position during angioplasty of a chronic total coronary occlusion: detection and subsequent procedural guidance by intravascular ultrasound.

We report a case of intravascular ultrasound (IVUS) imaging of a chronic total coronary artery occlusion angioplasty initially complicated by subintimal wire penetration. IVUS provided unique images of wire position and a "double-barrel" lumen that complemented angiographic data in initial diagnosis and in subsequent guidance of the procedure.

Adult↗

Value and limitations of intravascular ultrasound imaging in characterizing coronary atherosclerotic plaque.

Intravascular ultrasound uses a high-frequency, miniaturized, ultrasound transducer positioned on the tip of a coronary catheter to provide detailed cross-sectional images of the coronary vessel wall. Unlike angiography, which details only luminal encroachment, this imaging technique has the unique potential to provide an image of the atherosclerotic plaque, characterize its composition, and assess stenosis severity. Lipid-filled "soft" plaque, dense fibrous "hard" plaque, calcification, and thrombosis have all been identified on intravascular ultrasound images. Individual lesion types have been associated with specific clinical ischemic syndromes and with different responses to catheter-based intervention. By means of analyzing tissue composition, intravascular ultrasound may permit identification of high-risk lesions that may eventually rupture and cause unstable coronary ischemic syndromes. This article reviews the current approaches to plaque characterization by two-dimensional intravascular ultrasound imaging and addresses clinical implications, technical limitations, and future promise of the technique.

Calcinosis↗

Coronary reactivity to nitroglycerin: intravascular ultrasound evidence for the importance of plaque distribution.

OBJECTIVES: This study was designed to assess the extent and timing of vasodilation after intracoronary administration of nitroglycerin using intravascular ultrasound. We also sought to relate the magnitude of nitroglycerin-induced dilation to the distribution of atherosclerotic plaque. BACKGROUND: Although previous angiographic studies have shown that nitroglycerin can dilate both normal and stenotic coronary arteries, it remains uncertain whether atherosclerotic vessels can respond to nitroglycerin to the same extent as normal arteries in the clinical setting. METHODS: We analyzed a total of 48 segments from 48 patients by means of a multielement 3.5F to 5.5F 20-MHz intravascular ultrasound system before and after intracoronary administration of nitroglycerin (250 micrograms). Videotaped images were digitized, and the lumen cross-sectional area was measured with an electronic cursor. In noncircumferential lesions, the perimeters of the normal and diseased portions were measured separately to compare the reactivity to nitroglycerin in each portion. RESULTS: Of 48 sites examined 14 were normal by ultrasound, and 34 revealed atherosclerotic lesions. In the 14 normal segments nitroglycerin produced a large increase in cross-sectional area (31 +/- 16% [mean +/- SD]) within 60 s after injection. In the 34 atherosclerotic segments, nitroglycerin-induced dilation was impaired, and the cross-sectional area increased only 12 +/- 8% (p < 0.01). In 15 of 34 atherosclerotic segments, a noncircumferential lesion was identified, and the cross-sectional area after nitroglycerin increased an average of 17 +/- 6%. In the remaining 19 sites, circumferential disease was present, and the cross-sectional area increased by only 8 +/- 7% (p < 0.05 vs. normal or noncircumferential atherosclerotic segments). In noncircumferential lesions, the increase in the perimeter of the normal portion of the wall was significantly greater (14 +/- 6%) than the increase in the diseased portion (5 +/- 3%, p < 0.05). CONCLUSIONS: These data indicate that vasoreactivity after nitroglycerin administration is reduced in segments with atherosclerosis by ultrasound. We suggest that nitroglycerin-induced vasodilation at the stenotic segments can be produced primarily by expansion of the nondiseased portion of the vessel wall.

Adult↗

Myocardial contrast echo effect: the dilemma of coronary blood flow and volume.

Despite the useful information provided by myocardial contrast echocardiography, the meaning of myocardial contrast intensity remains elusive. This review is meant to define the contribution of physical and biologic factors in producing myocardial contrast and to elucidate the relative roles of coronary blood flow and intramyocardial blood volume in determining contrast effect. The main physical factors influencing the contrast echo effect include the properties of microbubbles as scattering elements (mainly their radius, compressibility, stability and concentration), electronic signal processing, instrument setting and contrast-induced signal attenuation. The effect of these factors can be limited by an appropriate experimental or clinical setup. Biologic factors are less easily controllable, and changes in coronary blood flow and alterations in myocardial blood volume appear to be the main determinants of myocardial contrast intensity. Moreover, these factors influence contrast intensity in opposite directions. Both the area under the time-intensity curve and the mean transit time of myocardial contrast are inversely related to coronary blood flow but directly related to myocardial vascularity and blood volume. Therefore, an increase in coronary flow not accompanied by an increase in myocardial vascularity and volume is accompanied by a decrease in the area under the curve and mean transit time of contrast. Conversely, an increase in coronary flow mediated by augmented myocardial vascularity and volume will produce an increase in the area under the curve and mean transit time. A better understanding of the physical and biologic determinants of contrast echo intensity will be fundamental in the clinical application of new agents and technologies.

Blood Flow Velocity↗

The assessment of left ventricular filling dynamics using an online automatic border detection algorithm: comparison with cineventriculography.

An echocardiographic system has been developed that performs automatic endocardial border detection and instantaneously calculates and displays a waveform of left ventricular cavity area versus time. The purpose of this study was to compare measurements of left ventricular filling dynamics from automatic border detection echocardiography with similar measurements from cineventriculography. Thirty-three patients undergoing cardiac catheterization had automatic border detection echocardiography performed within 45 minutes of cineventriculography. Ten patients had normal catheterization findings and 23 had cardiac disease. The automatic border detection waveforms generated from two echocardiographic views were measured to determine the fraction of filling occurring during the early diastolic rapid filling phase and during the filling phase resulting from atrial contraction. Similar fractions were derived from curves generated from frame-by-frame measurements of cineangiographic volumes. Results were analyzed by correlating echocardiographic and cineventriculographic results, and by a limits of agreement analysis (limits of agreement were +/- 2 standard deviations of the mean difference between echocardiography and cineventriculography). There were significant correlations between echocardiography and cineventriculography for each of the parameters studied. The best results were obtained for the apical four-chamber view (rapid filling fraction r = 0.72, P < 0.0001, atrial filling fraction r = 0.56, P < 0.001). Differences in filling patterns between normal and abnormal patient groups detected by cineventriculography were also detected by automatic border detection echocardiography. However, broad limits of agreement were observed, that may limit the ability of the automatic border detection system to reliably predict cineventriculographic results in an individual patient. Automatic border detection echocardiography can provide information about left ventricular filling dynamics that is similar to that obtained from frame-by-frame analysis of cineventriculograms. However, the variability in the results may limit the application of the technique in individual patients.

Adult↗

Transesophageal echocardiography of the aorta.

Transesophageal echocardiography (TEE) has become a widely used imaging technique for evaluating cardiac structure, function, and valvular anatomy. Transesophageal echocardiography has also provided a new perspective on the thoracic aorta, and there is growing evidence that the technique contributes valuable and sometimes unique information about aortic structure and pathology. Recently introduced multiplane transesophageal probes have improved visualization of the proximal and transverse aorta, but few comprehensive discussions of TEE's application in aortic disease exist. Therefore, we have reviewed the published literature and our institutional experience in transesophageal aortic ultrasonography. The available evidence strongly supports the use of TEE in aortic dissection and atherosclerosis and suggests potential utility in additional diseases of the aorta such as aneurysm, ulceration, trauma, and congenital or inherited malformation.

Aortic Dissection↗

Prognostic value of Doppler transmitral flow patterns in patients with congestive heart failure.

OBJECTIVES: This study was designed to determine whether Doppler echocardiographic transmitral flow patterns can predict cardiac mortality in patients with congestive heart failure. BACKGROUND: Previous studies have indicated that Doppler transmitral flow patterns are related to New York Heart Association functional class and exercise capacity in patients with congestive heart failure. However, the prognostic significance of these flow patterns is not known. METHODS: We analyzed the relation of transmitral flow patterns and cardiac mortality in 100 consecutive patients (76 men, 24 women; mean [+/- SD] age 60 +/- 11 years) with congestive heart failure symptoms and left ventricular ejection fraction < 40%. At the time of entry into the study, functional class and ejection fraction by radionuclide angiography were determined, and Doppler echocardiography was performed in all patients. Transmitral flow was obtained from the apical four-chamber view at the mitral annulus level. Measurements included early (E) and atrial (A) filling velocities, E/A ratio and deceleration time of the E wave. The patients were assigned to two groups according to E/A ratio or deceleration time of transmitral flow patterns, or both: a non-restrictive group (42 patients) with E/A < or = 1 or E/A = 1 to 2 and deceleration time > 140 ms, and a restrictive group (58 patients) with E/A > or = 2 or E/A = 1 to 2 and deceleration time < or = 140 ms. RESULTS: Of 100 patients, 26 died during a mean follow-up period of 16 +/- 8 months. The cumulative cardiac mortality rate determined by the Kaplan-Meier method was 14% at 1 year and 35% at 2 years. Cox proportional hazards model analysis revealed that transmitral flow (restrictive vs. nonrestrictive, chi-square 6.99, p = 0.008), patient gender (female vs. male, chi-square 4.59, p = 0.03) and New York Heart Association functional class (IV vs. II, chi-square 3.95, p = 0.05) were significantly related to cardiac mortality in patients with congestive heart failure. Mortality rate in the restrictive group was markedly higher than that in the nonrestrictive group at 1 year (19% vs. 5%, respectively, p < 0.05) and at 2 years (51% vs. 5%, respectively, p < 0.01) by log-rank test. Relative risk for cardiac death was estimated as 4.1 at 1 year and 8.6 at 2 years in the restrictive group compared with the nonrestrictive group. CONCLUSIONS: In patients with congestive heart failure, a restrictive transmitral flow pattern, female gender and advanced functional class are predictive of higher cardiac mortality. The restrictive transmitral flow pattern by Doppler echocardiography is the single best clinical predictor for cardiac death in patients with congestive heart failure.

Aged↗