Coronary angiography with magnetization-prepared T2 contrast.

A magnetization-prepared, T2-weighted sequence (T2 Prep) is used to suppress muscle and venous structures. When combined with lipid suppression, this technique improves the visualization of the coronary arteries. T2 Prep was designed to be rebust in the presence of flow as well as B0 and B1 inhomogeneities and may be combined with virtually any imaging technique. Here, it is implemented with both a single-slice spiral acquisition and a multi-slice spiral method that acquires up to 15 slices in a single breath-holding interval.

Arteries↗

The diminishing variance algorithm for real-time reduction of motion artifacts in MRI.

A technique has been developed whereby motion can be detected in real time during the acquisition of data. This enables the implementation of several algorithms to reduce or eliminate motion effects from an image as it is being acquired. One such algorithm previously described is the acceptance/rejection method. This paper deals with another real-time algorithm called the diminishing variance algorithm (DVA). With this method, a complete set of preliminary data is acquired along with information about the relative motion position of each frame of data. After all the preliminary data are acquired, the position information is used to determine which data frames are most corrupted by motion. Frames of data are then reacquired, starting with the most corrupted one. The position information is continually updated in an iterative process; therefore, each subsequent reacquisition is always done on the worst frame of data. The algorithm has been implemented on several different types of sequences. Preliminary in vivo studies indicate that motion artifacts are dramatically reduced.

Algorithms↗

MR spectroscopic imaging of collagen: tendons and knee menisci.

Water molecules associated with collagen have short transverse (T2) relaxation times. Projection-reconstruction techniques are able to achieve an echo time (TE) much shorter than conventional techniques, allowing imaging of tissues with T2 < 5 ms. Using these techniques, a conventional 1.5-T MRI human imaging system can directly image collagen-associated water from knee menisci and tendons in normal volunteers and patients. Long-T2 suppression improves the contrast between these structures and the surrounding tissue with long-T2 relaxation times. Spectroscopic imaging provides improved lipid/water registration and information about chemical composition and relaxation times. Direct imaging of tendons and menisci may provide more information about these structures and provide a new way to assess both injury and repair.

Collagen↗

MRS imaging using anatomically based k-space sampling and extrapolation.

A comprehensive strategy for the acquisition, reconstruction, and postprocessing of MR spectroscopic images is presented. The reconstruction algorithm is the most critical component of this strategy. It is assumes that the desired image is spatially bounded, meaning that the desired image contains an object that is surrounded by a background of zeros. The reconstruction algorithm relies on prior knowledge of the background zeros for k-space extrapolation. This algorithm is a good candidate for proton MR spectroscopic image reconstruction because these images are often spatially bounded and prior knowledge of the zeros is easily obtained from a rapidly acquired high resolution conventional MRI. Although the reconstruction algorithm can be used with the standard 3DFT k-space distribution, a distribution that relies on anatomical features that are likely to occur in the spectroscopic image can produce better results. Prior knowledge of these anatomical features is also obtained from a conventional MRI. Finally, the postprocessing component of this strategy is valuable for reducing subcutaneous lipid contamination. Overall, the comprehensive approach presented here produces images that are better resolved than standard approaches without increasing acquisition time or reducing SNR. Examples using NAA data are provided.

Algorithms↗

Short TE phosphorus spectroscopy using a spin-echo pulse.

In vivo phosphorus spectroscopy requires very short acquisition delays in order to capture the signal from components with short transverse relaxation times (T2). The echo time typical of standard slice selective spin-echo pulses are too long for this application, so hard pulse, free induction decay (FID) acquisitions have frequently been used instead. With FID, however, there is an interval between the time of coherence and data acquisition (acquisition delay), with resulting baseline distortions. In this paper we describe the design of a new short TE, slice-selective, composite spin-echo pulse with echo times as short as 2.5 ms. With a long TR, fully relaxed, multislice spectra can be collected. This technique will be useful for assessing in vivo, changes in brain phospholipid activity associated with psychiatric and neurological diseases.

Brain↗

Real-time motion detection in spiral MRI using navigators.

A technique has been developed whereby motion can be detected in real time during the acquisition of data. This enables the implementation of an algorithm to accept or reject and reacquire data during a scan. Frames of data with motion are rejected and reacquired on the fly so that by the end of the scan, a complete motion-free data set has been acquired. The algorithm has been implemented on several different types of sequences. Preliminary in vivo studies indicate that motion artifacts are dramatically reduced.

Abdomen↗

A three-dimensional spin-echo or inversion pulse.

In theory, multidimensional pulses can be designed to be selective in any number of dimensions. In practice, available gradient power has enforced a limit to two dimensions. We show here that three-dimensional pi pulses are feasible on commercial imaging machines provided that the range of off-resonance frequencies are limited.

Image Processing, Computer-Assisted↗

Echo-planar spin-echo and inversion pulses.

The echo-planar k-space trajectory can be used as the basis for any two-dimensional selective pulse. The main application is spectral-spatial pulses, which must be based on the echo-planar trajectory. In this paper we show how echo-planar spin-echo (EPSE) pulses may be designed.

Body Water↗

Incorporating lactate/lipid discrimination into a spectroscopic imaging sequence.

A spectroscopic imaging sequence incorporating a two-shot lactate editing method was used in two human brain studies to image lactate and NAA. The subtractive editing method allows separate images of lactate, NAA, and lipids to be collected during a single study with no SNR penalty. The sequence uses a spectral-spatial excitation for slice selection and water suppression, and employs inversion recovery and an echo time of 136 ms for additional lipid suppression.

Aspartic Acid↗

Novel approaches to low-cost MRI.

This paper presents a combination of speculative approaches, some related to earlier work and some apparently novel, which show great promise in providing a new class of MRI machines that would be considerably less expensive. This class would have advantages and disadvantages as compared to existing MRI, over and above that of low cost. The disadvantages include the apparent inability to perform classic spectroscopy, and limited flexibility in the area of selective excitation. The advantages include a fundamental immunity to inhomogeneity and susceptibility problems, the ability to create a wide class of machines that are designed for specific anatomy-related applications, the ability to design open machines for physician access, and improved capability for high speed imaging. Generic to all of the methods presented are a pulsed polarizing field and an oscillatory read-out bias field. The pulsed field initially polarizes the magnetic moments. Since it is not on during the readout operation it has negligible homogeneity requirements since changes in the field amplitude will merely shade the image intensity. During readout a relatively low bias field is used. To enable the use of a relatively inhomogeneous bias field, an oscillatory field is used that has a zero average value. This prevents any long-term buildup of phase errors due to a frequency error associated with inhomogeneity. Thus the average bias frequency will be determined solely by the frequency rather than the amplitude of the bias field. Three methods are described, all including the above features. The first two involve imaging in the laboratory frame, while the third involves imaging in the rotating frame. The second approach requires no RF excitation and the third approach uses RF bias and gradient signals. Some approaches to slice selection are described.

Costs and Cost Analysis↗

Magnetic resonance spectroscopic imaging of ethanol in the human brain: a feasibility study.

The in vivo distribution of ethanol in normal human brain following the consumption of a moderate amount of alcohol was measured using magnetic resonance spectroscopic imaging. Three subjects were studied, and the spatial distribution of brain ethanol, 60-min postingestion and measured at a spatial resolution of 1.5 cm, was found to be highly nonuniform with the relative ethanol signal in cerebral spinal fluid, gray matter, and white matter determined to be 1.00, 0.72, and 0.37, respectively. These spectroscopic imaging results indicate that whereas in vivo magnetic resonance studies of ethanol are feasible, quantitative studies of alcohol need to account carefully for the various tissue types within the observed volume.

Alcoholic Intoxication↗

Prospects for ultrasonic spectroscopy and spectral imaging of abdominal tissues.

A system for the digitization and frequency spectral analysis of radiofrequency data for ultrasonic waveforms backscattered from abdominal tissues is described. Studies of phantoms meant to simulate abdominal tissues of differing scattering characteristics indicated that frequency spectral differences due to differences in the frequency dependence of backscattering were seen with 5 MHz probes, but not with a 3.5 MHz probe. Studies of a phantom with a simulated lesion of altered scattering characteristics indicated potential for improved lesion detection and characterization, using custom circuitry developed for variable bandwidth filtering of received ultrasonic beams. The techniques discussed have potential for improved diagnosis of diffuse and focal abdominal abnormalities over that obtained with conventional ultrasonic imaging.

Abdomen↗

Inhomogeneity correction for in vivo spectroscopy by high-resolution water referencing.

One of the most common sources of distortion in in vivo spectroscopy is the inhomogeneity of the main magnetic field. This effect is particularly problematic when performing spectroscopic imaging, as the shim cannot be simultaneously optimized for all voxels. In this paper we present a technique to measure inhomogeneity rapidly, then show how to use the measurement to improve the analysis of the spectrum. This technique can be applied in conjunction with any spectroscopic localization method and any spectral quantitation algorithm. We present results from spectroscopic imaging of phantoms, then show application to a single-voxel water-suppressed proton brain study. We find that the quantitation of the in vivo spectrum is made immune to inhomogeneous line broadening.

Brain↗

Fast angiography using selective inversion recovery.

We have developed an enhancement of selective inversion recovery that allows us to obtain high-resolution angiograms in reduced scan time. By applying several read pulses following each tagging inversion pulse, we can obtain several phase encodes in each cardiac cycle, thereby reducing the total scan time required for a complete image. Using this technique, high-resolution angiograms can be obtained in as little as 15 s. Because the phase encodes are collected in short bursts separated by long pauses, care must be taken to maintain uniform signal weighting across phase-encoding views and avoid ghosting. We use an increasing flip-angle sequence to equalize signal level weighting across the readouts. The phase encodes are collected in a special order to minimize ghosting. A postprocessing technique is used to further reduce signal nonuniformity between phase encodes. This fast angiography technique can significantly reduce artifacts due to patient motion during scanning and is especially useful for imaging vasculature in regions of the body where respiratory motion is a problem.

Algorithms↗

Effects of RF amplifier distortion on selective excitation and their correction by prewarping.

In a magnetic resonance imaging system, an RF power amplifier is employed to boost an RF pulse to sufficient strength to excite the nuclear spins in a subject. The nonideal behavior of this amplifier distorts a selective-excitation pulse, and this distortion in turn degrades the slice profile. We have found two types of nonideal behavior particularly troublesome: nonlinearity and incidental phase modulation. One of their effects is the introduction of an unwanted "skirt" in the out-of-slice region of a slice profile. We present an effective method of correction in which a selective-excitation pulse is prewarped to compensate for the distortion.

Algorithms↗

Two-dimensional selective adiabatic pulses.

Using the technique of separable k-space excitation, we have designed a two-dimensional selective adiabatic pulse that inverts magnetization from a square region in the xy plane with insensitivity to RF variations. We also have designed a two-dimensional adiabatic pulse that inverts selectively in frequency and in one spatial dimension. The pulses should be useful for both MR imaging and spectroscopy. We present experimental results to demonstrate that the two-dimensional adiabatic pulses are feasible on commercial MR imaging systems.

Humans↗

Twisting radial lines with application to robust magnetic resonance imaging of irregular flow.

A problem with magnetic resonance angiograms of vessels containing irregular flow is that flow-induced dephasing can result in voids in the image. These void regions are susceptible to misinterpretation as regions of stenosis or other vessel pathology. Flow-induced dephasing can be minimized by using radial lines to cover k space. However, radial lines provide a very nonuniform, and hence, inefficient, coverage of k space. By twisting the outer portions of the radial trajectories, undistorted images of very rapid and turbulent flow can be obtained with a reasonable number of RF excitations.

Blood Flow Velocity↗

Deblurring for non-2D Fourier transform magnetic resonance imaging.

For several non-2D Fourier transform imaging methods, off-resonant reconstruction does not just cause geometric distortion, but changes the shape of the point spread function and causes blurring. This effect is well known for projection reconstruction and spiral k-space scanning sequences. We introduce here a method that automatically removes blur introduced by magnetic field inhomogeneity and susceptibility without using a resonant frequency map, making these imaging methods more useful. In this method, the raw data are modulated to several different frequencies and reconstructed to create a series of base images. Determination of degree of blur is done by calculating a focusing measure for each point in each base image and a composite image is then constructed using only the unblurred regions from each base image. This method has been successfully applied to phantom and in vivo images using projection-reconstruction and spiral-scan sequences.

Algorithms↗