Search PubMedSearch

PubMed · 8350720

Echo-planar spin-echo and inversion pulses.

Abstract

The echo-planar k-space trajectory can be used as the basis for any two-dimensional selective pulse. The main application is spectral-spatial pulses, which must be based on the echo-planar trajectory. In this paper we show how echo-planar spin-echo (EPSE) pulses may be designed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J Pauly, D Spielman, A Macovski. 1993. Echo-planar spin-echo and inversion pulses.. https://doi.org/10.1002/mrm.1910290609

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A model of unloaded human intervertebral disk based on NMR relaxation.

NMR relaxation rates were related to the composition of the nucleus pulposus from 11 and anulus fibrosus from six human intervertebral disks. Tissue water was proportional to glycosaminoglycan (GAG) and residue, the noncollagen, non-GAG portion of the dry weight (R2 = 0.74). The solid signal fraction depended on collagen and residue protons (R2 = 0.89). 1/T1 was proportional to collagen and residue (R2 = 0.97). T2 showed 2-4 components labeled A, B, C, and D, with means +/- standard deviations of 3.1 +/- 1.6, 17.5 +/- 9.5, 64 +/- 22, and 347 +/- 162 msec. Signal fractions of A and B depended on the collagen-associated water protons (R2 = 0.94 and 0.85), C on residue-associated water protons (R2 = 0.82), and D on GAG-associated water protons (R2 = 0.74). The data led to a model of disk architecture in which the collagen and residue were largely solid, forming distinct water compartments; the remaining water was present in a proteoglycan gel.

Body Water

An alternative explanation of the origin of the signal in diffusion-weighted MRI.

I formulated an alternative explanation for the origin of the signal in diffusion-weighted MRI (DWI) and tested it in a simple experimental model using gelatin. My findings indicate that the signal in DWI is influenced by the passage of water from the sol to the gel state, independently of the presence of cell structures or membrane-dependent diffusion.

Body Water

Non-invasive measurement of water content in a lung phantom by neutrons.

A novel, non-invasive technique for measuring water content in lungs is described. This technique could find important medical applications such as real time monitoring of lung edema development in patients affected by cardiac insufficiency undergoing physical effort. The technique is based on the moderation (speed decrease) of fast neutrons crossing the lungs, due mostly to the water contained in lungs. In the application of this diagnostic method, the necessary dose given to the patient is lower than that associated with lung imaging techniques that do not use an image intensifier. The results so far obtained are encouraging, and the method appears to be an improvement over those so far reported in literature as it is able to detect a lung water increase equivalent to 25% of a full edema with a 20% standard error. Research is being performed in order to refine the technique, investigate geometry effects and make the method suitable to the medical field.

Body Water