Search PubMed⌕ Search

Biomedical subjects

A Frigerio

Publications and source records attributed to A Frigerio.

At least 19 recordsLinked to original sources

Screen-detected vs clinical breast cancer: the advantage in the relative risk of lymph node metastases decreases with increasing tumour size.

Screen-detected (SD) breast cancers are smaller and biologically more indolent than clinically presenting cancers. An often debated question is: if left undiagnosed during their preclinical phase, would they become more aggressive or would they only increase in size? This study considered a registry-based series (1988-1999) of 3329 unifocal, pT1a-pT3 breast cancer cases aged 50-70 years, of which 994 were SD cases and 2335 clinical cases. The rationale was that (1) the average risk of lymph node involvement (N+) is lower for SD cases, (2) nodal status is the product of biological aggressiveness and chronological age of the disease, (3) for any breast cancer, tumour size is an indicator of chronological age, and (4) for SD cases, tumour size is specifically an indicator of the duration of the preclinical phase, that is, an inverse indicator of lead time. The hypothesis was that the relative protection of SD cases from the risk of N+ and, thus, their relative biological indolence decrease with increasing tumour size. The odds ratio (OR) estimate of the risk of N+ was obtained from a multiple logistic regression model that included terms for detection modality, tumour size category, patient age, histological type, and number of lymph nodes recovered. A term for the detection modality-by-tumour size category interaction was entered, and the OR for the main effect of detection by screening vs clinical diagnosis was calculated. This increased linearly from 0.05 (95% confidence interval: 0.01-0.39) in the 2-7 mm size category to 0.95 (0.64-1.40) in the 18-22 mm category. This trend is compatible with the view that biological aggressiveness of breast cancer increases during the preclinical phase.

Aged↗

[A rationale basis for airways conditioning: too wet or not too wet? ].

Medical gases conditioning during mechanical invasive ventilation is nowadays a problem. In fact, in spite of conditioning guidelines, absolute humidity (AH) into 25-35 mg/l, clinical evaluation of the optimal level of airway humidification has not yet been established with certainty. Physiologically, during spontaneous respiration the airway hydric balance, inspiratory AH expiratory AH, is negative of 27 mg/l about. Usually the patients on mechanical ventilation have an expiratory AH of 32-33 mg/l. An overhumidification of inspired gases, positive airway hydric balance, gives anatomic-physiological alterations of airways and lung parenchyma. During invasive mechanical ventilation, the practice of active hot humidifiers has a positive or level airway hydric balance. We think that inspired AH must be equal to expired AH to maintain an airway hydric balance at least level. At last, the temperature of inspired gases, with active hot humidifiers, shouldn't exceed 32-34 degrees C.

Algorithms↗

Depressive symptoms as measured by the CDI in a population of northern Italian children.

The aim of this study was to evaluate some Children's Depression Inventory (CDI) psychometric properties and the prevalence of depressive symptoms in an unselected Italian sample of two hundred and eighty-four children aged 8 years. The CDI internal consistency was adequate (Cronbach's alpha:.80). The mean and standard deviation of CDI and the percentage of children at risk of depression (10.6%) in this sample are consistent with the figures reported by other studies carried out in northern Europe and North America. There were differences in gender and socioeconomic level in that boys scored higher than girls, and in the lower socioeconomic level there were more children at risk of depression. Ten items best discriminated children at risk for depression with 94% of correct classification. Most of these items consisted of observable signs. It is suggested that the CDI has noteworthy consistency across samples of relatively different cultures, that it can reliably be employed in the assessment of young children, and that observable signs outnumber internalizing symptoms of depression among children at risk

Catchment Area, Health↗

A brief neuropsychological assessment for the differential diagnosis between frontotemporal dementia and Alzheimer's disease.

The neuropsychological performance (including measures of language, semantic memory, visual and spatial perception and executive functions) of a group of 14 patients with the clinical diagnosis of probable frontotemporal dementia was compared with that of a group of 14 patients with a clinical diagnosis of probable Alzheimer's disease. The aim was to identify a specific cognitive profile of frontotemporal dementia, which could be used to select a sensitive, short evaluation for the differential diagnosis with Alzheimer's disease. Both groups were severely impaired in most tasks, including those 'frontal lobe' tests which have been suggested to play an important role in differential diagnosis. Significant differences were found only for a minority of tests (oral praxis, visual-spatial perception, and verbal fluency). A logistic regression showed that a shortened testing procedure based on four tests (Rey-Osterreith complex figure test recall, phonemic fluency, oral apraxia, and cube analysis) achieved a 70% sensitivity and 80% specificity for the correct classification of patients in the frontotemporal dementia or Alzheimer's disease group. In conclusion, a brief neuropsychological evaluation including these four tests, as well as other measures sensitive to the frontal impairment, can be useful in the differential diagnosis between the two pathologies, along with the clinical data.

Aged↗

Effect of a single dose of ibuprofen lysinate before embryo transfer on pregnancy rates in cows.

Embryo implantation is a critical step in both cows and humans. The use of ibuprofen lysinate to enhance implantation has been investigated in cattle with the specific aim of improving pregnancy rates after embryo transfer. In this study, heifers (n = 100) were assigned randomly to one of two groups: one group was treated i.m. with 5 mg ibuprofen lysinate kg(-1) body weight 1 h before embryo transfer and a control group received vehicle only. A single embryo was transferred into each recipient cow. There was a significant difference in the number of pregnancies after embryo transfer between cows in the treated (41 of 50; 82%) and control (28 of 50; 56%) groups (P < 0.05). These data indicate that ibuprofen lysinate may be an effective adjunctive treatment for assisted reproduction in cattle. Further studies are needed to clarify whether this effect is associated with the reduction of cyclooxygenase enzyme isoforms during embryo transfer or whether other mechanisms are involved.

Animals↗

Mammographically detected in situ lobular carcinomas of the breast.

We present ten cases of mammographically detected lobular carcinoma in situ (LCIS), involving a single area of variable size (up to a quadrant) in seven cases and the entire gland in three cases. Histologically, calcifications were associated with necrotic central areas within the in situ carcinomatous foci. Multiple foci of LCIS were observed in all five cases in which mastectomy had been performed. Cytologically, the lesions were characterized by a solid proliferation of round noncohesive cells with nuclei of intermediate size. Immunocytochemically, all cases were E-cadherin and p53 negative, and c-ErbB-2, GCDFP-15 and estrogen receptor positive. The proliferation index, evaluated with Ki67, was in the low range. Four cases were associated with foci of infiltrating lobular carcinoma (ILC). These findings contradict the commonly held opinion that LCIS is not mammographically detectable because of its lack of necrosis and calcification. This study documents the existence of a variant of LCIS exhibiting the mammographic features and central necrosis classically associated with ductal carcinoma in situ (DCIS), while retaining the spatial distribution, cytological composition and immunocytochemical features of lobular carcinoma.

Biomarkers, Tumor↗

Effects of serotonin transporter promoter genotype on platelet serotonin transporter functionality in depressed children and adolescents.

OBJECTIVE: To investigate possible associations between serotonin transporter (5-HTT) promoter genotypic variants (l/l, l/s, and s/s) and differential regulation of platelet 5-HTT functionality parameters in a group of drug-naive depressed children and adolescents and healthy controls. METHOD: Children and adolescents with major depression (n = 18) defined by DSM-III-R criteria and normal controls (n = 21) were assessed both for platelet serotonin functionality and for genotypic variants on 5-HTT promoter region. Four parameters were considered: (1) serotonin uptake rate (Vmax); (2) serotonin dissociation constant (K(m)); (3) paroxetine binding and density of site (Bmax); and (4) paroxetine dissociation constant (Kd). RESULTS: Depressed children had lower Vmax and K(m). Control subjects with l/l genotype had significantly higher Vmax than control subjects with l/s and s/s genotype. Control subjects with l/l genotype also had significantly higher Vmax than their depressed homologs. In contrast, Vmax was not significantly different between depressed and nondepressed subjects who carried the other 2 genotypes. The 5-HTT promoter genotype, diagnoses, or their interaction had no effect on the other serotonin parameters. CONCLUSIONS: While showing a significant decrease of Vmax and K(m) in a group of drug-naive depressed children and adolescents, these data suggest that l/l genotype has a substantial effect on the decrease of Vmax during a depressive episode.

Adolescent↗

[Positive predictive value of radiologic features in mammography and contribution of assessment procedures].

PURPOSE: To investigate the positive predictive value for cancer of abnormal mammographic findings and the role of assessment procedures. MATERIALS AND METHODS: We reviewed a series of 962 patients recalled and examined in the 1st Breast Screening Center of Turin, out of 18; 996 women aged 50-59 screened for the first time from 1991 to 1995, within a population-based mammography program. The diagnostic assessment procedures included one or more of the following: physical examination, additional mammographic views (detail or magnification), ultrasonography, and ultrasonography/X-ray-guided fine needle aspiration cytology. Surgical biopsies detected 152 cancers. RESULTS: The positive predictive value for screening mammography with abnormal findings steadily grew from 10.9% in 1991-92 to 15.6% in 1993, topping 21.1% in 1994 and 20.1% in 1995. The highest positive predictive value for cancers was observed among cases referred for opacities with irregular margins (88.2%) and isolated calcifications (23.8%). The benign/malignant biopsy ratio was .54 in 1991-92, .31 in 1993, .27 in 1994 and .25 in 1995. The accuracy of assessment procedures was different for each abnormal radiologic sign: the accuracy of cytology was high for opacities, intermediate for calcifications, low for architectural distortions; ultrasonography and physical examination had low sensitivity among cases referred for calcifications or opacities with regular margins. The positive predictive value of surgical indications was high for opacities, intermediate for calcifications, low for architectural distortions. The role of assessment procedures in excluding surgery was different for each abnormal radiologic sign. DISCUSSION AND CONCLUSIONS: The results of this study confirm the accuracy of mammography in the early detection of breast cancer and the different role of assessment procedures in the various abnormal mammographic findings. The improvement in positive predictive value for screening recalls from about 10% (close to recommended European standards) up to about 20% (well above European standards) demonstrates the importance of the "learning curve" within the screening team. Most of this improvement could be referred to refined diagnostic criteria for calcifications, as shown by an increase in positive predictive value for calcifications from 13.7% in 1991-92 to 40.5% in 1995.

Breast Neoplasms↗

[Neurolytic block of the celiac plexus and splanchnic nerves with computed tomography. The experience in 150 cases and an optimization of the technic].

INTRODUCTION: CT-guided celiac plexus and splanchnic nerve neurolytic blocks are procedures for pain relief in patients with upper abdominal malignancies. In the last 20 years, the technique has been modified by the introduction of CT guidance providing improved precision and safety. We report our personal experience and provide suggestions for technique optimization. MATERIALS AND METHODS: In 1991-1998 we performed 150 celiac plexus and/or splanchnic nerve neurolytic blocks with ethyl alcohol in 144 cancer patients; the procedure was repeated in 6 patients. In 69% of cases the patient had a pancreatic lesion. We prefer an anterior approach with very thin needles (22 Gauge). The sites of alcohol injection (celiac plexus, splanchnic nerves or both) are chosen after evaluation of anatomy by preliminary CT scans, or during the procedure, depending on alcohol (mixed with a contrast agent) spread. RESULTS: The mean duration of the procedure ranged 50 min (1991) to 22 min (1998). 48 hours after the block we obtained major pain relief in 79% of cases. After 15 days, 21% of patients had no pain (drugs: none), 29% had mild pain (therapy: non-steroid anti-inflammatory drugs), 32% had marked pain (therapy: non-steroid anti-inflammatory drugs and, occasionally, opioids), 18% had severe pain (only opioid therapy). Pain relief was more frequent in splanchnic nerve blocks. DISCUSSION: Our experience confirms that neurolytic celiac plexus and/or splanchnic nerve block is a good choice in the treatment of upper abdominal cancer pain. We would also like to add that: 1) celiac plexus block with CT guidance (with the needle tip positioned anterior to aorta) and splanchnic nerve block (with the needle tip positioned posterior to diaphragmatic crura) are no longer two separated techniques, but they can be chosen and combined according to patients needs. 2) All procedures can be performed with anterior approach, in supine position, with a single thin needle, allowing to reach the target without any complication, even after puncturing stomach, liver, bowel, pancreas or aorta. 3) With CT guidance, even splanchnic nerve neurolysis is a low-risk technique, which should be adopted in all cases of insufficient alcohol spread in the celiac plexus. 4) When the operators are skilled and experienced enough, the time required for the block can be significantly decreased to nearly the time required for US-guided or fluoroscopic-guided procedures.

Autonomic Nerve Block↗

[Breast carcinoma diagnosed in mammographic screening incidentally. Research on the radiologic signs in prior mammograms].

PURPOSE: To determine how many cancers screen-detected at subsequent rounds were already visible on previous screening mammograms, and to study their radiological features. MATERIALS AND METHODS: The previous screening mammograms of 100 women who had cancers screen-detected at subsequent rounds (group A), and the negative screening mammograms of 200 women (group B) who had a further negative screening test two years later, were mixed for a new reading. The two groups were similar for age and year of examination. These films were blindly reviewed by 5 radiologists. Then, mammograms were reviewed retrospectively, with knowledge of subsequent diagnostic results. Finally the A group findings were classified as: 1) true negative: no radiological signs; 2) minimal sign: a nonspecific abnormality is retrospectively visible at the site of subsequent cancer; 3) false negative: "she should have been recalled"; 4) misdiagnosis at assessment: the woman had been recalled, but the cancer was missed after the assessment procedures. RESULTS: 60% of cases were true negatives, 29% were minimal signs, 9% were false negative and 2% were misdiagnosed at assessment. The most common radiological sign found among false negative cases was an architectural distortion: opacities and calcifications were more frequent among minimal signs. Only 10 of 40 cancers retrospectively visible on previous mammograms had reached stage II at diagnosis. At blinded review, the radiologists found false abnormalities in a considerable number of healthy women (average: 29%). DISCUSSION AND CONCLUSIONS: Our study shows that mammography sensitivity can be improved. Cancer radiological signs may go undetected due to difficult interpretation (opacities, calcifications) or perception (architectural distortions). The use of a low threshold of suspicion (as in a reading test) in real screening might permit to detect more cancers (most of them, however, would not reach advanced stages at subsequent rounds), but might also lead to many unnecessary assessments and, probably, to some benign biopsies in healthy women. In conclusion, an attempt at improving mammography sensitivity by lowering the threshold of suspicion can not be directly recommended due to the considerable negative effects related to a loss in specificity. A reading test similar to the one presented in our study would be a useful training procedure for radiologists who are involved in a screening program.

Breast Neoplasms↗

[Quality and homogeneity monitoring of radiologists in the Turin mammographic screening. Comparison of the pilot phase results].

The Turin mammographic screening program was designed to be carried out in several independent screening centers because of the large proportion of population involved (76,000 women aged 50 to 59 years). The first center began working in 1992 and the second center was opened in 1995. The latter center carried out an early pilot study in which 1024 women were examined to assess the homogeneity and the quality of the results. The results were then compared with European quality standards and with the results of both the pilot and the active screening periods in the first center. The results from the second center were very good as far as detection rate is concerned (7.8/1000-2.9/1000 in carcinoma < or = 1 cm). This rate is higher than the so-called "desirable" European standard. Recall rate and benign/malignant biopsy ratio were higher than the so-called "fair" European standard (recall rate: 7.1%; B/M biopsy ratio: 0.62). These results are slightly superior to those of the pilot period in the first center and slightly inferior to the results of active screening in the same center. The improvement relative to the pilot period in the first center (1991) is probably related to technical progress, such as the introduction of the double mammographic projection. The difference relative to the results from the active screening period in the first center (1992-1994) reflects different specific experience. Even though pilot periods have no statistical significance, they can be used for comparison, and in our experience they have proved, with positive results, the quality of the mammographic screening program provided to the Turin population.

Female↗

[Cost analysis of a mammographic screening program].

In this paper we evaluate the principal direct costs (staff, capital and maintenance equipment, supplies, hardware and software system, mail, advertising campaign) of the mammographic screening programme "Prevenzione Serena" (Torino), from the recruitment time to the diagnostic assessments of screen positive cases. On the basis of the annual situation of a screening Unit which supplies two-view mammographies, read by two radiologists, and of a 60% attendance rate and a 5% recall rate, we estimate a total annual cost of 1.4 thousand million lire (875,000$), a cost per invited woman of 38,600 lire (24$), per tested woman of 64,400 lire (40$) and per breast cancer detected of 9.2 million lire (5,750$). Staff accounts for about 60% of the total cost. We evaluate also some alternative scenarios, with different hypothesis about the useful life of the equipment, the discount rate, the attendance and the recall rate.

Aged↗

[Dosimetric and qualitative evaluations of the use of rhodium filtration in mammography].

The value of rhodium filtration in mammography was compared with that of conventional molybdenum; dosimetric and qualitative tests were performed on a phantom and in vivo on informed and consenting patients. Phantom dosimetric tests confirmed a dose reduction with rhodium filtration changing according to thickness and primary beam energy. With rhodium filtration the dose decreased by 40% on the average topping 67% in breasts thicker than 6.5 cm. No significant differences were observed between rhodium and molybdenum filtration in clinical and phantom qualitative tests. Four radiologists--three of them in double blind--studied 29 mammograms repeated in the same technical setting and expressed a very slight preference for molybdenum also in thick and dense breasts. The slight preference was not based on higher diagnostic yield and therefore clinically irrelevant. Preferences appeared to be subjective, differing from one radiologist to another. In conclusion, the authors suggest the use of rhodium filtration in thick breasts because of the lower administered dose and of shorter exposure time with direct magnification.

Breast Neoplasms↗

[Diagnostic imaging in non-palpable breast lesions. Targeted++ ultrasonography versus direct radiologic magnification].

The main target of mammography in asymptomatic women is the early diagnosis, or rather the identification, of non-palpable breast cancers. Doubtful or suspicious findings on conventional mammograms with no clinical evidence call for radiologic or other complementary imaging techniques to assess the exact lesion nature. Direct magnification and US are targeted techniques to employ as additional investigations after conventional mammography. Fifty consecutive patients were referred to our department of radiology for the preoperative localization of non-palpable breast lesions previously identified on conventional mammograms. The diagnostic or complementary roles of direct magnification and of US were thus investigated. US was always repeated during the preoperative localization; a 10-MHz immersion sectorial probe was used. Magnification was performed if absent or poor in conventional mammograms. The contribution of each technique to conventional mammography was graded as valuable (A), medium (B), or null (C). The lesions were grouped according to their structure: microcalcifications (a), nodules (b), scars (c), and complex lesions (a+b, a+c, b+c, ecc.). Six cases are included in our series which had been diagnosed as questionable or suspicious on previous mammograms. In our department, they were diagnosed as benign. Two of them were operated on because biopsy was required by the gynecologist and the other underwent stereotaxic FNB: negative cytology was considered the final diagnosis. Forty-six histologic and 4 cytologic examinations diagnosed 25 malignant and 25 benign lesions. Direct magnification was of great value in all cases, whereas US was useless in microcalcifications and useful in nodular or complex lesions, especially those with a nodular component. However, the incidence of US false-negatives was high, even in very suspicious cases on mammography, which suggests that US negativity cannot be considered an adequate sign to rule malignancy out.

Breast Diseases↗

Inter-observer and intra-observer variability of mammogram interpretation: a field study.

To evaluate the performance of radiologists in mammographic mass screening, seven radiologists read blindly the mammograms of 45 women (two views for each breast). The films included 12 normal, 24 benign disease and 9 cancers. The readings were repeated after 2 years. As expected, variability was higher among radiologists than between the two readings of the same radiologist, but general reproducibility was moderate. Kappa values for a positive/negative classification were 0.45 at the first and 0.44 at the second reading (inter-observer comparisons). For the intra-observer comparisons, Kappa values ranged from 0.35 to 0.67 (mean 0.56). Generally, accuracy was low partly due to the difficulty of the cases. A slight increase in sensitivity was observed at the second reading. The level of agreement is a good indicator of accuracy. Proper training and standardization of criteria are essential before mass breast screening is implemented.

Breast Diseases↗

MOv18 monoclonal antibody in diagnostic applications: capability to recognize the histotype of the original tumor.

Cells from 52 ascitic fluids and 28 abdominopelvic cavity washings, obtained from 46 ovarian cancer patients, 17 patients bearing malignancies of non ovarian sites and 17 patients with non-malignant ovarian diseases, were tested using 2 methods: traditional cytology and monoclonal antibody immunofluorescence. The immunologic test using the MOv18 MAb, raised against ovarian carcinoma, revealed immunoreactive cells in 83% of the 36 cytologically positive fluids and in one of the 8 negative fluids from ovarian carcinoma patients and in 18% of the 17 fluids from patients with non-malignant ovarian disease. Forty six cytologically positive ascitic fluids from malignant patients were analyzed in order to evaluate the ability of this MAb to identify the histotype of metastatic cells. Ninety-three percent (26/28) of the effusions from nonmucinous ovarian carcinomas contained MOv18-positive cells, whereas no reactive cells were found in cytologically malignant fluids from patients with ovarian tumors of other oncotypes or with carcinomas of non-ovarian origin. The MOv18 reagent, used as an adjuvant in cytological analysis, can help in the identification of the histotype of metastatic cells of unknown origin.

Adenocarcinoma↗

Non-extraction HPLC method for simultaneous measurement of dyphylline and doxofylline in serum.

A direct injection HPLC method for the simultaneous measurement of dyphylline and doxofylline in serum is reported. Chromatography is carried out with a "Pinkerton" internal surface reversed-phase column and phosphate buffer (0.1 mol/L, pH 6.8) as mobile phase. Absorbance at 275 nm is monitored. Only 10 microL of serum is required to detect less than 1 mg of each drug per liter in biological samples. The standard curve for the method is linear over the range 6-100 mg/L, and precision is acceptable for both drugs, with CVs of 2% and 1.5% for respective concentrations of 6.2 and 25 mg/L. None of the 76 drugs tested for interference affected the measurement of either drug. Four samples can be injected per hour. This method provides a fast, accurate way to monitor two interesting therapeutic agents used in chronic obstructive airway diseases.

Chromatography, High Pressure Liquid↗