Determination of x-ray spectral distribution from transmission measurements using K-edge filters.

Accurate high-resolution x-ray spectral distributions can be obtained with an intrinsic germanium crystal. This technique is difficult to implement since it requires expensive, complicated, and bulky equipment. If energy resolution requirements are relaxed, then the above drawbacks can be overcome and an x-ray spectrometer that is small, inexpensive could be built. A technique that meets these requirements is described here. X-ray spectra with about 7-keV resolution can be achieved by obtaining transmission measurements through a number of different K-edge filters. Using these measurements, a system of equations is set up and solved giving the required spectral distribution. The technique has been tested using 80, 100, and 120-kVcp x-ray beams with total filtrations of 3.78, 5.78, 9.06 mm A1, and 3.78 mm A1 + 0.137 mm Ho. The results show that the calculated spectra closely resemble tabulated spectra. The errors ranged from 3% to 13%. The half-value layers (HVL) were also calculated and compared to the HVL obtained from tabulated spectra and were found to differ by about 7%.

Spectrum Analysis↗

Selective iodine imaging using lanthanum K fluorescence.

Time-dependent subtraction techniques have tremendously improved the visualization of iodinated vessels. These techniques suffer from motion artifacts, however, since the mask image is acquired several seconds prior to the contrast image. A K-edge subtraction technique for selectively imaging iodine using the characteristic x rays from a lanthanum secondary target is presented. The K alpha lines of lanthanum closely straddle the K edge of iodine. A prepatient iodine filter will alter the ratio of K alpha 1 to K alpha 2 intensities; by subtracting two images made with different K alpha 1/K alpha 2 ratios, iodinated structures can be isolated. Since the method requires no mask image, motion artifacts are reduced. Preliminary images acquired with an image intensifier/photodiode array detector system are shown. Theoretical performance of this method is compared to other iodine-selective imaging techniques on the basis of exposure and dose. The feasibility of using lanthanum K fluorescence for rapid clinical iodine-selective imaging is discussed.

Angiography↗

A xenon ionization detector for scanned projection radiography: 95-channel prototype evaluation.

We have designed, constructed, and tested a 95-channel prototype xenon ionization detector for use in scanned projection radiography (SPR). This detector has higher spatial resolution, is more dose efficient, and is easier to construct than computed tomography (CT) xenon ionization detectors. It consists of two parallel plates separated by a 2-mm gap filled with xenon gas at 2 MPa (20 atm). One plate is a high-voltage electrode while the other is a circuit board etched to form an array of metal collector strips focused on the x-ray source. The resulting detector channels are 0.5 mm wide and 6 cm long. In this paper we present results from measurements of system noise and detector channel calibration. We compared the detector system to a screen/film system and found that it allows the detection of structures with 0.17% radiographic contrast compared to 2% contrast required for detection with screen/film when tested by imaging a 10-cm-thick Lucite phantom with a 10 X 10(-6) C/kg exposure. From images of resolution test patterns, the limiting resolution of the detector is 2.0 1p/mm at 1.6 magnification. Images of reduction mammoplasty tissue samples, obtained with 1/17 the exposure of screen/film images, had the same low-contrast sensitivity but contained less high-contrast detail than the film images.

Radiographic Image Enhancement↗

A xenon ionization detector for scanned projection radiography: Xenon/Freon 13B1 comparison.

In a companion paper, we reported on the construction and testing of a xenon gas ionization detector for use in line scanned projection radiography. Experimental results indicate that the detector has sufficient resolution for chest radiography, but higher resolution is required for mammography. Theoretical analysis suggested that a detector pressurized with Freon 13B1 would have better resolution and higher x-ray energy efficiency than a xenon-filled detector for energies below 60 keV. In this paper we compared, theoretically and experimentally, Freon 13B1 to xenon as the detector gas. For a 120-kVp x-ray spectrum, the detector filled with 2.0 MPa of xenon had less channel-to-channel crosstalk, a higher quantum efficiency (QE), and twice the output signal than the detector filled with 1.4 MPa of Freon (highest possible pressure at room temperature), while for a 60-kVp spectrum, crosstalk is the same, but the detector has slightly higher QE and 1.4 times the energy efficiency when filled with Freon instead of xenon. We conclude that xenon is better for high-kVp imaging, while Freon at a lower pressure is slightly better for low-kVp imaging.

Bromochlorofluorocarbons↗

A photodiode array x-ray imaging system for digital angiography.

A line scanning imaging system that can be used to make low-noise x-ray images to detect low-contrast structure is described. The system makes use of a 1024-element, self-scanning, photodiode array (Reticon RL 1024S) optically coupled to an x-ray image intensifier tube. Low-noise images are obtained by imaging only small areas of interest at a time to reduce the noise resulting from the detection of scattered radiation, and by making use of the very large dynamic range (8000:1) solid-state photodetector. Some performance characteristics of the diode array system are discussed. It was found that while sensitivities of individual elements differed by up to +/- 15% from the average, they could be corrected with a precision of 0.02% to 0.04% of the maximum signal. The limiting spatial resolution of the system in the direction of the diode array was 2.0 cycles/mm, limited by the image intensifier. The system linearity was studied by measuring the attenuation of a monoenergetic x-ray beam by Plexiglas. The measured attenuation agreed with the expected exponential decrease over a range of approximately 1000 to within experimental error. The imaging capabilities of the system were demonstrated by imaging an angiographic phantom consisting of an iodine-filled tube with an asymmetric 20% stenosis. The stenosis was oriented on the tube surface furthermost from the detector resulting in an image with a 2% radiographic contrast change but no decrease of the tube width. The stenosis was clearly imaged using a temporal subtraction technique.

Angiography↗

Dual-energy mammography: initial experimental results.

Dual-energy x-ray techniques may be able to enhance the detectability of calcifications in mammographic examinations by removing the background "clutter" caused by contrast between adipose and glandular tissue. This hypothesis is examined experimentally by implementation of dual-energy imaging on a prototype digital scanned projection radiography system developed in our laboratory. A model of the propagation of signal and noise in dual-energy processing for a given radiation dose is validated by measurements from phantom images. The experimental imaging system has low spatial resolution and cannot be operated at dose-optimum energies; however, since both the single- and dual-energy images are subject to the same technical limitations, a comparison of such images allows an assessment of the benefits of dual energy. Experimental images of breast tissue specimens, showing improved detectability of calcifications when obscuring background clutter is removed, are presented. The dose required for a given signal-to-noise ratio can be reduced by smoothing the higher energy image prior to dual-energy processing. For practical implementation, it is reasonable to smooth the higher energy image such that its variance is reduced fourfold.

Computers↗

A method for modulation transfer function determination from edge profiles with correction for finite-element differentiation.

In this paper we describe a technique for determining the modulation transfer function (MTF) of an imaging system from an experimentally obtained edge profile. The technique includes an exact correction for the frequency passband of the finite-element differentiation required to obtain the line spread function from the edge spread function. This correction has been ignored by investigators in the past and is required whenever finite-element differentiation is used rather than analytic differentiation of a model fitted to the edge response data. The magnitude of the MTF correction is approximately 11% at f = fc/2 and approximately 57% at f = fc, where fc = fs/2 is the maximum frequency reproducible without aliasing with a sampling rate of fs. The correction is performed in the spatial frequency domain by multiplying the uncorrected MTF by 1/sinc (pi f/2fc). A computer simulation is presented to demonstrate the effect and the correction procedure. An experimental MTF of an x-ray image intensifier system obtained using this technique is found to be consistent with an MTF obtained using a bar pattern test phantom.

Computer Simulation↗

Therapy imaging: a signal-to-noise analysis of metal plate/film detectors.

We have measured the modulation transfer functions [MTF (f)'s] and the noise power spectra [NPS (f)] of therapy x-ray detectors irradiated by 60Co, 6- and 18-MV radiotherapy beams. Using these quantities, we have calculated the noise-equivalent quanta [NEQ (f)] and the detective quantum efficiency [DQE (f)] to quantitate the limitations of therapy detectors. The detectors consisted of film or fluorescent screen-film combinations in contact with copper, lead, or tungsten metal plates. The resolution of the detectors was found to be comparable to fluorescent screen-film combinations used in diagnostic radiology, however, the signal-to-noise ratio [SNR (f)] of the detectors was limited due to film granularity. We conclude that improved images can be obtained by using alternative detector systems which have less noise or film granularity.

Cobalt Radioisotopes↗

Scanned-projection digital mammography.

The effectiveness of film-screen mammography is limited by tradeoffs between latitude and contrast, film granularity, and the need to increase dose when antiscatter methods are used. We are currently developing a scanned-projection digital mammography (SPDM) system to overcome these limitations. The system consists of a pair of scanning slits, a high-resolution x-ray image intensifier tube, a linear photodiode array, and a digital display. The detective quantum efficiency of the SPDM system at spatial frequencies up to 3 cycles/mm is similar to that of mammographic film-screen combinations, but is lower at high frequencies. For low-contrast objects as small as 0.1 mm in diameter, the signal-to-noise ratio is currently equal to that of optimally exposed mammographic film-screen images for equal dose to the breast and superior for regions which would be underexposed or overexposed on film. This is achieved by the use of a low-noise detector system, geometric magnification, and scatter elimination. Images of a contrast-detail phantom and excised breast tissue illustrate the superior contrast sensitivity of SPDM.

Female↗

Theoretical optimization of a split septaless xenon ionization detector for dual-energy chest radiography.

It is proposed that digital scanned projection radiography of the chest be performed by using an energy-sensitive septaless xenon ionization detector (SXID) to obtain dual-energy images. The proposed detector is composed of a front region, sensitive to low-energy x rays, and a rear region, sensitive to high-energy x rays, separated by a suitable filter layer. We have developed a simple, precise theoretical formulation for dual-energy optimization, and applied it to the split SXID. We describe the variation of optimum detector performance with source kilovoltage and filtration (material and thickness), and hence heat loading, under conditions of constant exposure and constant dose. We estimate dose as the average absorbed dose to an equivalent water layer of suitable thickness, assuming slab geometry, so that the calculation is as simple as that for exposure.

Humans↗

Therapy imaging: source sizes of radiotherapy beams.

We have developed a novel method, which employs large lead collimators and computed tomography reconstruction techniques, to measure the intensity distributions of x-ray sources of radiotherapy devices. Using this method, we have measured the intensity distributions of x-ray sources from 60Co, 6-, 18-, and 25-MV radiotherapy devices. The x-ray sources of the accelerators were all elliptical in shape, but varied in eccentricity, and the sizes of the accelerator sources varied from 0.7 to 3.3 mm full width at half-maximum. The 60Co source was circular in shape and 20 mm in diameter, however, the output from this source was not uniform across its face. The modulation transfer functions (MTF's) (at the image plane) calculated for the accelerator sources, assuming an image magnification of 1.2, had similar magnitudes at low spatial frequencies as the MTF's of the metal plate/film detectors commonly used for therapy imaging. However, the source MTF's declined much more rapidly at high spatial frequencies. Therefore, for geometries commonly found in radiotherapy, the loss in spatial resolution due to the x-ray source was at least equal to that caused by electron and photon scatter within the metal plate/film detectors.

Cobalt Radioisotopes↗

Arterial flow characterization with a photodiode array based imaging system.

An x-ray imaging system is described that can be used for obtaining arterial blood flow information. The system consists of a linear photodiode array image detector, simple optical and mechanical components, and a data acquisition microcomputer that connect to a conventional x-ray image intensifier based fluorography system. Flow information is obtained by detecting the movement of a small, locally injected bolus of radio-opaque contrast agent. This is done by determining the bolus mass, integrated over the cross-sectional area, at each of 1024 positions along the length of the artery with a sampling rate of up to 200 samples per s. It is shown in a phantom study that the peak flow velocity can be measured with an accuracy of +/- 5% by detecting the bolus arrival times at each of the 1024 positions. The mean velocity is obtained with similar accuracy using a cross-correlation technique and a modified form of the Stewart-Hamilton principle. In addition, it is shown that the separation and reattachment points resulting from flow separation near a stenosis can be determined from the bolus clearance times. The locations of these points are consistent with theoretical values for the cosine shaped symmetric 89% stenosis used in this study.

Angiography↗

Therapy imaging: a signal-to-noise analysis of a fluoroscopic imaging system for radiotherapy localization.

We have been developing a digital fluoroscopic imaging system to replace the portal films that are currently used to verify patient positioning during radiotherapy treatments. Our system differs from previously reported devices in the construction of the detector and in the operation of the TV camera. The signal, noise, and signal-to-noise properties of this system have been determined by measuring the modulation transfer function [MTF(f)], the noise power spectra [NPS(f)], and by calculating the detective quantum efficiency [DQE(f)] of the system. The results show: (i) that the spatial resolution of the system is determined largely by the lens of the TV camera and by frame grabber; and (ii) that the noise in the system is dominated by the secondary light quanta, due to the poor light collection efficiency of the optical chain. Despite these physical limitations, a contrast-detail study shows that the fluoroscopic system is better at detecting large, low contrast objects than portal films. Therefore the system is already a reasonable alternative to portal films and modifications to the metal plate/phosphor detector, lens, TV camera, and frame grabber should improve the performance of the system further.

Fluoroscopy↗

An accurate method for direct dual-energy calibration and decomposition.

We propose the use of conic and cubic surface equations (surfaces of second and third order) to directly approximate the dual-energy equations (the integral equations for the dual-energy log-signal functions, i.e., the negative logarithms of the relative detector signals, considered as functions of the basis-material component thicknesses of the object) and especially their inverses. These types of surface equations require a minimum number of calibration points, and their solutions are smooth, monotonic functions with the correct linear asymptotic behavior. The accuracy of this method is investigated and compared to that of conventional polynomial approximations, both for simulated and real calibration data, taken from two split-detector systems. These systems provide a more stringent test of our method than comparable dual-kVp systems, due to the greater nonlinearity of their log-signal and inverse functions. For these systems, we show that direct approximation of the inverse dual-energy equations using the simple eight-term rational form of the conic surface equation provides an extremely fast decomposition algorithm, which is accurate, robust in the presence of noise, and which can be calibrated with as few as 9 calibration points, or robustly calibrated, with a built-in accuracy check, using only 16 calibration points. Also, we show that extreme accuracy of approximation (to within less than 10(-6) in log-signal and 1 micron in material thickness) is theoretically attainable using the eighteen-term form of the cubic surface equation, which has a closed-form analytic solution. Finally, we consider the effects of noise on calibration accuracy, and derive simple formulas which relate the true and apparent root-mean-square (rms) accuracies. These formulas then allow the comparison of the true rms calibration accuracies of various surface approximations, considered as functions of the total calibration heat loading of the x-ray tube.

Algorithms↗

An in-line optical image translator with applications in x-ray videography.

Many applications in radiography require, or would benefit from, the ability to translate, i.e. move, an optical image in the detector plane. In this paper, we describe the design and characterization of a prism-based optical image translator for insertion into existing XRII-video imaging systems. A pair of prisms rotatable about the optical axis form a very compact in-line optical image translator for installation in the parallel light path between an x-ray image intensifier and its video camera. Rotation of the prisms translates the XRII optical image on the camera target. With the addition of x-ray and light collimators to limit the image to a single video line, x-ray streak images may be acquired. By rotating an object in the x-ray beam during a streak, a complete computed tomography (CT) data set may be acquired. This image translator can translate an image anywhere in the focal plane of a 50-mm-output lens within a 40-mm-diam circle. The prisms have an aperture of 50 mm, permitting an optical speed of F/2 with a 50-mm output lens. The design is insensitive to angular alignment errors. This image translator is achromatic, since the spectral width of the output phosphorus of image intensifiers is sufficient to introduce blurring in a nonacrhomatic design. A prism-based image translator introduces image distortion, since the prisms do not operate at minimum deviation. The distortion is less than 4% over all parts of a typical detector area, and less than 1% in the central region of the image.(ABSTRACT TRUNCATED AT 250 WORDS)

Biophysical Phenomena↗

A time-delay integration charge-coupled device camera for slot-scanned digital radiography.

We have developed a low-noise digital camera based on a 512 x 96 element CCD operating in the time-delay integration mode. This camera has been combined with an x-ray image intensifier to record radiographic images produced by a scanning slot beam of radiation. This results in the rejection of a large fraction of scattered radiation, without a significant increase in x-ray tube heat loading or image acquisition time. Here we describe the design of our CCD camera and the results of our investigations of camera resolution, linearity, noise, and quantum efficiency. We have found that both the resolution limit (50 mm-1) and the dynamic range (2100) of this novel camera are greater than reported values for conventional video cameras. Applications of this system in digital angiography and mammography are discussed.

Angiography↗

Activity distribution of a cobalt-60 teletherapy source.

In the course of quantifying the effect of radiation source size on the spatial resolution of portal images, a concentric ring structure in the activity distribution of a Cobalt-60 teletherapy source has been observed. The activity distribution was measured using a strip integral technique and confirmed independently by a contact radiograph of an identical but inactive source replica. These two techniques suggested that this concentric ring structure is due to the packing configuration of the small 60Co pellets that constitute the source. The source modulation transfer function (MTF) showed that this ring structure has a negligible influence on the spatial resolution of therapy images when compared to the effect of the large size of the 60Co source.

Cobalt Radioisotopes↗

Analytic approximation of the log-signal and log-variance functions of x-ray imaging systems, with application to dual-energy imaging.

In the analysis of x-ray system performance, the log-signal function, or negative logarithm of the relative detector signal, and the analogously defined log-variance function, are of central importance. These are smooth, monotonic functions of object thickness, which are nonlinear for nonmonoenergetic x-ray source spectra. If we assume a dual-energy decomposition of the object into two basis materials, then they can be written as analytic functions f(x,y) and f*(x,y), respectively, of the component thicknesses (x,y) of the object. In this paper, we analytically develop the Taylor series of these functions, prove that they converge everywhere, and parametrize their coefficients via suitable central spectral moments of the basis-material attenuation coefficients. We then show how the lower-order moments can be used to construct, in closed form, smooth, monotonic, second-order (conic) surface functions which closely approximate f(x,y) and f*(x,y) over the entire feasible domain. A simplified construction, based on using appropriate asymptotic values of the basis-material attenuation coefficients to match the asymptotic behavior of these functions, is also given. The inclusion of image components with K-edge absorption spectra, such as iodine, is done without effort. Extension of the results to the construction of similar (virtually exact) third-order (cubic) surface approximations is straightforward. As an illustration of the broad applicability of this approach, we extend our analysis to the construction of similar approximations to the inverse (decomposition) functions for an arbitrary dual-energy system, and investigate their numerical accuracy for a model dual-kVp system. We conclude that this extended analysis provides an accurate description of the system behavior in terms of a small number of physically meaningful parameters. This parametrization permits greater physical insight into the system behavior, while at the same time simplifying its mathematical description, and similarly facilitates the analysis of various measures of imaging performance via either analytic or numerical methods.

Aluminum↗