Ross River virus isolations from mosquitoes in arid regions of Western Australia: implication of vertical transmission as a means of persistence of the virus.

Outbreaks of mosquito-borne Ross River (RR) virus disease (epidemic polyarthritis) occur suddenly in the arid north and interior of the State of Western Australia, often within a few weeks of heavy rainfall. Between outbreaks, these regions may undergo long periods of drought, with little or no mosquito or arbovirus activity. The means by which RR virus is reintroduced or reactivated in these areas when environmental conditions favor mosquito-borne virus activity are unknown. In this paper, we describe isolations of RR virus from eight mosquito species trapped at two different locations, one coastal and one inland, in the arid Pilbara region of Western Australia, prior to outbreaks of epidemic polyarthritis. The isolation of RR virus has not been previously reported for five of these species and the isolations from the other three species are new records for Western Australia. The timing and number of isolations of RR virus from Aedes (Ochlerotatus) vigilax (Skuse, 1889) implicate that species as a vector of the virus on the Pilbara coast. Significantly, RR virus was isolated from pools of male Ae. vigilax and male Ae. (Macleaya) tremulus (Theobald, 1903) mosquitoes. This is the first report of RR virus (or other Australian arbovirus) isolates from wild-caught male mosquitoes. Both Ae. vigilax and Ae. tremulus have desiccation-resistant eggs that can survive long periods of drought, making them ideal candidates for the overwintering of arboviruses. The findings implicate vertical transmission as a means of persistence of RR virus in arid regions of Australia and therefore offer a likely explanation for the sudden recurrence of virus activity after heavy rains.

Aedes↗

Diterpene metabolites from two chemotypes of the marine sponge Myrmekioderma styx.

Three apparent chemotypes of the marine sponge Myrmekioderma styx exist. An acyclic diterpene, styxenol A [1], has been isolated from the shallow water chemotype, while three tricarbocyclic diterpenes 3, 6, and 7 have been isolated from the deep chemotype. The structures were elucidated based on spectral methods including homo- and hetero-nuclear 2D nmr experiments. Compounds 1, 3, and 6 exhibit moderate cytotoxicity against the P-388 murine leukemia cell line and the A549 human lung tumor cell line.

Animals↗

Isolation of fetal trophoblast cells from peripheral blood of pregnant women.

Fetal trophoblast cells were isolated from maternal peripheral blood by means of murine monoclonal antibodies of high specificity and affinity for human syncytiotrophoblast and nonvillous cytotrophoblast cells. The cells were isolated in sufficient numbers to allow polymerase chain reaction (PCR) amplification of the Y-chromosome-specific DNA sequence from the peripheral blood of thirteen pregnant women. The fetal sex predicted by PCR analysis of the isolated trophoblast cells accorded with that ascertained by karyotyping of chorionic villus samples in eleven of twelve women studied in early pregnancy and with the sex of the baby on delivery in one woman studied at 34 weeks' gestation. Isolation of these fetal cells could allow noninvasive diagnosis of a wide range of inherited disorders.

Antibodies, Monoclonal↗

Isolation of Murray Valley encephalitis and Ross River viruses from Aedes normanensis (Diptera: Culicidae) in Western Australia.

Of eight viruses isolated from 28,909 female (643 pools) Aedes normanensis collected from the north of Western Australia, two were identified as Murray Valley encephalitis virus and six as Ross River virus. The two isolates of Murray Valley encephalitis virus represent the first confirmed isolations of this virus from an Aedes species. The possible implications of these findings with regard to virus survival mechanisms during the dry season are discussed.

Aedes↗

In vitro assays to study role of T cell-derived factors on human B lymphocytes should take into consideration inhibiting effect of large granular lymphocyte subset (CD5-,CD16+) that can contaminate B cell preparations.

In these studies, the inhibitory role of a large granular lymphocyte (LGL) subset (CD5-,CD16+) on pokeweed mitogen (PWM)-induced B lymphocyte differentiation was examined. CD5-,CD16+ LGL cells are the predominant subset of LGL cells and are possibly distinct from other LGL subsets in that they lack B and T cell markers. CD5-,CD16+ LGL possess abundant FcIgG receptors and previous studies have clearly demonstrated that in the presence of insoluble immune complexes, this LGL subset will inhibit B lymphocyte differentiation in the presence of T cells. In the present studies, we analyzed the inhibiting role of CD5-,CD16+ LGL cells that had not been activated by immune complexes. B + L preparations obtained by removal of E rosette-forming T cells were further depleted of T lymphocytes by complement-dependent lysis of T cells using a monoclonal antibody reactive to total T cells (Leu-1, CD5 antigen, Becton-Dickinson). B lymphocytes in such B + L preparations failed to differentiate into plasma cells containing intracytoplasmic immunoglobulin (Ig), in the presence of PWM, T cell-derived helper supernatants (THS), and interleukin-2 (IL-2). However, B cells differentiated under these conditions, when B + L preparations were further depleted of CD5-,CD16+ LGL cells by complement-dependent lysis using a monoclonal antibody (Leu-11) reactive to CD16 antigen of FcIgG receptors present on LGL cells. These studies indicated that CD5-,CD16+ cells unlike the CD8-positive T suppressor cell, will directly inhibit B lymphocyte differentiation into plasmacytoid cells containing intracytoplasmic Ig when T lymphocytes are not present. However, addition of a few T lymphocytes (less than 10%) to purified B + L preparations abrogated the CD5-,CD16+ LGL cell inhibition of B cell differentiation.

Adult↗

Control of infection in general practice: a survey and recommendations.

Twenty general practices in four areas in Britain were surveyed to establish their needs for and practices of sterilising and disinfecting equipment. Of the 327 items of equipment and instruments examined in the survey, 190 were satisfactorily decontaminated, 100 were treated in a way judged to result in doubtful decontamination, and in 37 cases treatment was considered unsatisfactory. Decontamination apparatuses (autoclaves, hot air ovens, and hot water disinfectors) were generally in good working order, but the use of chemical disinfectants was often inappropriate. Recommendations were made on appropriate methods of decontamination for various items in common use in general practice. By virtue of the large numbers of patients treated by general practitioners there is a substantial possibility of transmitting infection; having appropriate methods for decontaminating instruments and equipment is therefore imperative.

Communicable Disease Control↗

Water quality control trials: statistical tables for direct comparison between membrane filtration bacterial counts and the multiple tube method with a description of the bacteriological method.

Experiments in the quality control of water samples are being conducted in the Public Health Laboratory Service and the water industry in the United Kingdom. The number of distributions which have been made is 7 and 92 laboratories are now participating. The methods used for preparing and distributing samples are described. Some participating laboratories use the multiple tube method and some use membrane filtration to assess the presence of coliforms and Escherichia coli. The results are, therefore, a mixture of estimated numbers and direct colony counts. In order to compare results from these two different laboratory methods statistical tables have been compiled to show the most likely multiple tube result corresponding to each colony count. Tables relating to two commonly used tenfold dilution series are presented. To illustrate how these tables may be used we present results from a typical quality control distribution. The analyses of these results are generally satisfactory but show a tendency for lower counts using the membrane filtration method and more false negative results with E. coli counts.

Colony Count, Microbial↗

Legionella pneumophila in aerosols from shower baths.

Routine examination of the water system in an establishment where showers were used by staff after work or leisure activities revealed the presence of Legionella pneumophila. Descaling and steaming cleared the system but six months later recolonization was found to have occurred. L. pneumophila was isolated from air samples collected in the shower room whilst the shower was in operation. No clinical cases have occurred. Serological examination of those using the showers throughout the six month period together with a control group showed no evidence of infection.

Aerosols↗

Survival of Legionella pneumophila in a model hot water distribution system.

A virulent strain of Legionella pneumophila was inoculated into an enclosed system supplied with unsterilized water from a domestic hot water supply. Growth of bacteria was monitored over 10 weeks. An increase in the number of organisms other than legionellas occurred but few amoebae were observed and none could be cultured. Viable counts of L. pneumophila in the circulation fluid decreased slightly. However, particles of debris which accumulated in the apparatus and which were stained by the indirect fluorescent antibody technique were found to be almost totally composed of L. pneumophila. On dismantling the apparatus Legionella was isolated in moderately high numbers from several different types of surfaces, particularly natural rubber and silicone.

Hot Temperature↗

An assessment of some hazards associated with the collection of venous blood.

Some potential hazards of three commercially available blood collecting devices are compared with the conventional syringe method. A simulated venous system using blood containing a bacterial spore tracer was used to estimate surface and aerosol contamination. No appreciable difference in potential hazard to the operator was demonstrable by the methods employed.

Aerosols↗

Comparison of dose-time-fractionation schemes in non-oat cell lung cancer.

A series of 205 patients with inoperable, non-oat cell carcinoma of the lung were treated with three different dose-fractionation schedules. Fifty-six patients received 5000 rads in 25 fractions over five weeks (continuous, A); 79 patients received 2000 rads in five fractions over five days, with two weeks' rest, followed by 2000 rads in five fractions over five days (split-course, B); 70 patients received 3000 rads in 10 fractions over two weeks, followed by three weeks' rest and another 3000 rads (split course, C). The 24-month survival was 33% for A, 15% for B and 25% for C. The split course was better tolerated and radiation fibrosis was dose-related.