Search PubMedSearch

Biomedical subjects

A Cole

Publications and source records attributed to A Cole.

At least 19 recordsLinked to original sources

Intramuscular wire electromyography of the subscapularis.

The action of the subscapularis muscle is an important component in maintaining shoulder stability. Because of its relative inaccessibility, there have been few electromyographic (EMG) studies of its normal patterns of activity. The subscapularis is innervated by two or more distinct nerves, and therefore the upper and lower parts of the muscle may have different functional roles depending on the position of the humerus. The purpose of this study was to develop safe, reproducible insertion paths to the upper and lower parts of the subscapularis. Six subjects with no previous history of shoulder injury were evaluated. The paths of insertion were designed based on previous anatomical studies as well as dissections. Two pairs of intramuscular wire electrodes were inserted: one directed toward the upper subscapularis and one toward the lower subscapularis. Electrode locations were confirmed using posteroanterior and lateral radiographs and through electrical stimulation. EMG data were recorded during isometric internal rotation exercises with the humerus in 0 or 90 degrees abduction. Significant differences were observed in the EMG activity recorded from the two pairs of electrodes. The EMG activity of the upper subscapularis either remained the same or decreased in going from 0 to 90 degrees abduction, while that of the lower subscapularis increased. The observed differential response confirmed that the electrodes were in different parts of the subscapularis. These preliminary results suggest that in future EMG studies, the subscapularis should be considered as at least two independent muscle units.

Electric Stimulation

Possible protein binding displacement interaction between glibenclamide and metolazone.

The effects of metolazone on the protein binding of glibenclamide were studied. It was found that increasing metolazone concentrations up to 100 ng/ml had no significant effect on the protein binding of glibenclamide studied at 10 micrograms/ml. Metolazone is unlikely to cause a clinically significant increase in the free fraction of glibenclamide in patients receiving both drugs.

Aged

The use of balloon-tipped electrodes for permanent cardiac pacing.

A new balloon-tipped ventricular endocardial electrode for permanent artificial cardiac pacing is described. Following transvenous insertion of the electrode to the right ventricular apex, the distal balloon is inflated with contrast material in order to wedge the electrode tip between or beneath trabeculae and prevent displacement. fifty-nine electrodes were implanted, including a second generation type incorporating a wedge tip as well as the balloon. The incidence of displacement was 17% with 10% of cases being early, and 7% late. Early in the series, 50% Urografin was used to inflate the balloon and this resulted in premature deflation and early electrode displacement in two of the nine patients. When the concentration of Urografin was reduced, the balloon remained inflated for a longer period and the incidence of early displacement was reduced to 8%. However, there was still a late displacement of 8%. Only one wedge-tipped balloon electrode displaced. This electrode had a faulty sealing mechanism and the balloon could not be adequately inflated. There was a 3% incidence of early and a 3% incidence of late threshold problems with the electrode. However, name of the wedge-tipped balloon electrodes exhibited this problem. It was concluded that this new electrode did not fulfill its objectives. The total electrode failure rate, including displacements and episodes of high threshold was approximately 24%.

Aged

A metallurgical examination of fractured stainless-steel ASIF tibial plates.

Between 1970 and 1973 99 tibial fractures were treated by rigid internal fixation with ASIF plates. The fractures were all regarded as sufficiently stable for exercise without weight bearing, thus needing no additional external support during the healing period. Four of the plates broke late in the healing period, after the onset of weight bearing. These fractures had some degree of delayed union with slight resorption of the bone ends, resulting in cyclical bending of the plate. Examination of 2 of the fractured plates by scanning electron microscopy, electron microprobe analysis and optical metallography revealed that the primary cause of plate fracture was fatigue. There was no evidence that corrosion fatigue or inclusion content were factors leading to plate fracture.

Adult

CHO cell repair of single-strand and double-strand DNA breaks induced by gamma- and alpha-radiations.

Neutral and alkaline sucrose gradient sedimentation analysis was used to measure double- and single-strand breaks in the DNA of Chinese hamster ovary (CHO) cells exposed to either gamma- or alpha-radiation. After irradiation, cells were incubated for 15-180 min to test the ability of the cell to rejoin the DNA breaks. Essentially complete rejoining was observed for single-strand breaks induced by gamma- or alpha-doses below 20 krad and for double-strand breaks induced by gamma doses below 60 krad. Approximately 80% rejoining was observed for double-strand breaks induced by alpha doses below 40 krad. At higher doses, the repair system appeared to saturate in such a way that essentially no additional breaks were rejoined.

Alpha Particles

Computer takeover?

Explore the source record for details and available documents.

Child