A physical phantom for the calibration of three-dimensional X-ray microtomography examination.

X-ray microtomography is rapidly gaining importance as a non-destructive investigation technique, especially in the three-dimensional examination of trabecular bone. Appropriate quantitative three-dimensional parameters describing the investigated structure were introduced, such as the model-independent thickness and the structure model index. The first parameter calculates a volume-based thickness of the structure in three dimensions independent of an assumed structure type. The second parameter estimates the characteristic form of which the structure is composed, i.e. whether it is more plate-like, rod-like or even sphere-like. These parameters are now experiencing a great diffusion and are rapidly growing in importance. To measure the accuracy of these three-dimensional parameters, a physical three-dimensional phantom containing different known geometries and thicknesses, resembling those of the examined structures, is needed. Unfortunately, such particular phantoms are not commonly available and neither does a consolidated standard exist. This work describes the realization of a calibration phantom for three-dimensional X-ray microtomography examination and reports an application example using an X-ray microtomography system. The calibration phantom (external size 13 mm diameter, 23 mm height) was based on various aluminium inserts embedded in a cylinder of polymethylmethacrylate. The inserts had known geometries (wires, foils, meshes and spheres) and thicknesses (ranging from 20 microm to 1 mm). The phantom was successfully applied to an X-ray microtomography device, providing imaging of the inserted structures and calculation of three-dimensional parameters such as the model-independent thickness and the structure model index. With the indications given in the present work it is possible to design a similar phantom in a histology laboratory and to adapt it to the requested applications.

Calibration↗

Human postural response to lower leg muscle vibration of different duration.

Body lean response to bilateral vibrations of soleus muscles were investigated in order to understand the influence of proprioceptive input from lower leg in human stance control. Proprioceptive stimulation was applied to 17 healthy subjects by two vibrators placed on the soleus muscles. Frequency and amplitude of vibration were 60 Hz and 1 mm, respectively. Vibration was applied after a 30 s of baseline. The vibration duration of 10, 20, 30 s respectively was used with following 30 s rest. Subjects stood on the force platform with eyes closed. Postural responses were characterized by center of pressure (CoP) displacements in the anterior-posterior (AP) direction. The CoP-AP shifts as well as their amplitudes and velocities were analyzed before, during and after vibration. Vibration of soleus muscles gradually increased backward body tilts. There was a clear dependence of the magnitude of final CoP shift on the duration of vibration. The amplitude and velocity of body sway increased during vibration and amplitude was significantly modulated by duration of vibration as well. Comparison of amplitude and velocity of body sway before and after vibration showed significant post-effects. Presented findings showed that somatosensory stimulation has a long-term, direction-specific influence on the control of postural orientation during stance. Further, the proprioceptive input altered by soleus muscles vibration showed significant changes in postural equilibrium during period of vibration with interesting post-effects also.

Adult↗

Device to measure intra-operatively the primary stability of cementless hip stems.

The primary stability of cementless prostheses is critical for the long-term outcome of the operation. Surgeons are currently driven only by their experience in evaluating the extent of stem stability achieved. The aim of the present work was to develop a new device that enables the stability of a cementless stem to be quantitatively assessed intraoperatively. The angle of the stem/femur rotation under torsion and the torque are acquired and compared in real-time to a pre-set threshold inferred from the literature. The device indicates whether the stem is stable or not. It was extensively tested and finally validated in vitro on cadaveric and composite femurs hosting different sizes of the same kind of prostheses, implanted with different levels of press-fitting. The overall accuracy (23%) takes into account not only the overall measurement error but also the variability due to differences in bone quality and stem press-fitting. This error was deemed sufficient to discriminate between stable and unstable implants.

Arthroplasty, Replacement, Hip↗

Periodical in-situ re-calibration of force platforms: a new method for the robust estimation of the calibration matrix.

The paper provides a new technique based on a least-squares approach for the accurate estimation of a force platform calibration matrix using simple manual procedures, when the direction of the applied loads cannot be perfectly aligned with the axes of the platform. This new procedure can be applied to all force platforms and allows the combined application of vertical and horizontal forces, both static and time-varying. The robust calibration method includes the angular errors in the least-squares parameter vector, thus reducing the bias in the estimated calibration matrix parameters. The performance of the robust method was compared with the conventional one, using a numerical simulation approach starting from a known calibration matrix. With the conventional approach, in noiseless conditions, the maximum error due to load misalignment (SD = 3 degrees) was 6% for the direct terms and over 10% for the cross-talk terms. With the robust method, these errors reduced to zero and were always below 0.4%, even when realistic noise was superimposed on the measures. With perfectly aligned loads and realistic output noise, the confidence intervals of the calibration matrix parameters were very similar for the two methods, demonstrating that the increased number of parameters did not affect the reliability of the estimate.

Biomechanical Phenomena↗

Numerical model to predict the long-term mechanical stability of cementless orthopaedic implants.

The objective of this research was to develop a purely biomechanical model, intended to predict the long-term secondary stability of the implant starting from the biomechanical stability immediately after the operation. A continuous rule-based adaptation scheme was formulated as a dynamic system, and the work verified if such a model produced unique and clinically meaningful solutions. It also investigated whether this continuous model provided results comparable with those of a simpler, discrete-states model used in a previous study. The proposed model showed stable convergence behaviour with all investigated initial conditions, with oscillatory behaviour limited to the first steps of the simulation. The results obtained with the wide range of initial conditions support the hypothesis of the existence and uniqueness of the solution for all initial conditions. The differences between the continuous model and the simpler and more efficient finite-states model were found to be extremely modest (less than 4% over the predicted bonded area). Because of these minimal differences, the use of the much faster finite-states model is recommended to investigate asymptotic conditions, and the continuous model described should be used to investigate the evolution over time of the adaptive process.

Adaptation, Physiological↗

Feature selection of stabilometric parameters based on principal component analysis.

This study addresses the challenge of identifying the features of the Centre of pressure (COP) trajectory that are most sensitive to postural performance, with the aim of avoiding redundancy and allowing a straightforward interpretation of the results. Postural sway in 50 young, healthy subjects was measured by a force platform. Thirty-seven stabilometric parameters were computed from the one-dimensional and two-dimensional COP time series. After normalisation to the relevant biomechanical factors, by means of multiple regression models, a feature selection process was performed based on principal component analysis. Results suggest that COP two-dimensional time series can be primarily characterised by four parameters, describing the size of the COP path over the support surface; the principal sway direction; and the shape and bandwidth of the power spectral density plot. COP one-dimensional time series (antero-posterior (AP) and medio-lateral (ML)) can be characterised by six parameters describing COP dispersion along the AP direction; mean velocity along the ML and AP directions; the contrast between ML and AP regulatory activity; and two parameters describing the spectral characteristics of the COP along the AP direction. On the basis of the results obtained, some guidelines are suggested for the choice of stabilometric parameters to use, with the aim of promoting standardisation in quantitative posturography.

Adult↗

Comparison of logistic and Bayesian classifiers for evaluating the risk of femoral neck fracture in osteoporotic patients.

Femoral neck fracture prediction is an important social and economic issue. The research compares two statistical methods for the classification of patients at risk for femoral neck fracture: multiple logistic regression and Bayes linear classifier. The two approaches are evaluated for their ability to separate femoral neck fractured patients from osteoporotic controls. In total, 272 Italian women are studied. Densitometric and geometric measurements are obtained from the proximal femur by dual energy X-ray absorptiometry. The performances of the two methods are evaluated by accuracy in the classification and receiver operating characteristic curves. The Bayes classifier achieves an accuracy approximately 1% higher than that of the multiple logistic regression. However, the performances of the two methods, evaluated by the area under the curves, are not statistically different. The study demonstrates that the Bayes linear classifier can be a valid alternative to multiple logistic regression in the classification of osteoporotic patients.

Aged↗

HIDE: a new hybrid environment for the design of custom-made hip prosthesis.

This technical note describes a new software environment (HIPCOM design environment, HIDE) for the design of custom-made total hip replacements. These devices are frequently designed using general-purpose mechanical computer-aided design (CAD) programs using a set of bone contours extracted from the computer tomography (CT) images as anatomical reference. On the contrary, the HIDE system was developed to let the operator directly design the stem shape onto the CT images in a single-step operation. The operator can directly import CT data in DICOM format or use special functions to reconvert to a digital stack, the CT images printed on a radiological film. Once the stack of CT images is loaded, the operator can design the implant shape by imposing control sections directly on the CT images. The interpolation of these control sections produces the basic 3D shape of the custom-made stem. The shape is then exported to the CAD-computer-aided manufacturing (CAM) program to refine the design and to generate the part program to manufacture the implant with a CNC tooling machine. Using HIDE, the duration of design steps it affected was reduced by more than 50% with respect to the standard method in use at the manufacturer site. HIDE also improved the accuracy and the repeatability of the whole procedure. The learning curve became flat after only ten cases. These good results were achieved because of the integration of the vectorial description of the prosthetic component with the raster description of the CT data that allowed the designer to use all details available in the CT images.

Computer-Aided Design↗

Border-tracing algorithm implementation for the femoral geometry reconstruction.

In some orthopaedic applications such as the design of custom-made hip prostheses, reconstruction of the bone morphology is a fundamental step. Different methods are available to extract the geometry of the femoral medullary canal from computed tomography (CT) images. In this research, an automatic procedure (border-tracing method) for the extraction of bone contours was implemented and validated. A composite replica of the human femur was scanned and the CT images processed using three different methods, a manual procedure; the border-tracing algorithm; and a threshold-based method. The resulting contours were used to estimate the accuracy of the implemented procedure. The two software techniques were more accurate than the manual procedure. Then, these two procedures were applied to an in vivo CT data set in order to determine to most critical region for repeatability. Only for the images located in this region, the repeatability measurement was carried out for six in vivo CT data sets to evaluate the inter-femur repeatability. The border-tracing method was found to achieve the highest repeatability.

Algorithms↗

Effects of hip joint centre mislocation on gait analysis results.

Methods to determine the hip joint centre (HJC) location are necessary in gait analysis. It has been demonstrated that the methods proposed in the literature involve large mislocation errors. The choice should be made according to the extent by which HJC location errors distort the estimates of angles and resultant moments at the hip and knee joints. This study aimed at quantifying how mislocation errors propagate to these gait analysis results. Angles and moments at the hip and knee joint were calculated for five able-bodied subjects during level walking. The nominal position of the HJC was determined as the position of the pivot point of a 3D movement of the thigh relative to the pelvis. Angles and moments were then re-calculated after having added to HJC co-ordinates errors in the range of +/-30 mm. Angles and moments at both hip and knee joints were affected by HJC mislocation. The hip moments showed the largest propagation error: a 30 mm HJC anterior mislocation resulted in a propagated error into flexion/extension component of about -22%. The hip abduction/adduction moment was found the second largest affected quantity: a 30 mm lateral HJC mislocation produced a propagated error of about -15%. Finally, a 30 mm posterior HJC mislocation produced a delay of the flexion-to-extension timing in the order of 25% of the stride duration. HJC estimation methods with minimum antero-posterior error should therefore be preferred.

Adult↗

An improved technique for the extraction of stochastic parameters from stabilograms.

An improved characterization of the dynamics of postural sway can provide a better understanding about the functional organization of the postural control system as well as a more robust tool for postural pattern recognition. To this aim, a novel parameterization was applied to the stabilogram diffusion analysis formerly proposed by Collins and De Luca [Collins JJ, De Luca CJ. Open-loop and closed-loop control of posture: a random-walk analysis of center-of-pressure trajectories. Exp Brain Res 1993;95:308-18] that considered the act of maintaining posture as a stochastic process. The main purpose of the present technique was to overcome some drawbacks of the model presented by Collins and De Luca that may restrain its potential application in clinical practice. The approach uses a unique non-linear model to describe the center of pressure (COP) dynamics that reduces the number of parameters and decreases their intra-subject variability; consequently, fewer trials are required to perform reliable estimates of stochastic parameters and this is of particular importance for subjects that cannot afford many repeated measurements because of age or pathology. Four new statistical mechanics parameters (NSMP) were computed on the log-log stabilogram diffusion plots and their estimates were compared in terms of reliability and sensitivity to the visual conditions with: (1) a minimal set of four summary statistic scores (SSS); and (2) the six statistical mechanics parameters (SMP) proposed by Collins and De Luca. All four NSMP showed at least a fair-to-good reliability (intraclass correlation coefficient, ICC>0.49) while SMP (ICC>0.20) showed some poor reliability. A better overall reliability was also observed with respect to SSS. Moreover, only NSMP had a similar score for eyes open and eyes closed conditions. Three out of four NSMP were also significantly sensitive to eyes open or closed conditions (P<0.001) while only three out of six SMP were sensitive to operating conditions (P<0.01).

Humans↗

A novel transducer for the measurement of cement-prosthesis interface forces in cemented orthopaedic devices.

When a cemented orthopaedic device is being investigated there is a need to estimate the forces at the cement-prosthesis interface. For this reason a miniature transducer was developed that could be included inside the surface of most prostheses. A load cell (based on a piezoelectric sensor) and the required accessories and amplification were custom designed and built. The present work describes the validation that was performed on the piezo sensors alone, when mounted on a simplified structure, and when applied to a hip stem.Linearity, repeatability, reproducibility, and sensibility to shear and axial eccentric loads were tested, yielding satisfactory results. The repeatability on the same sensor was found to be good while reproducibility between sensors was lower. Thus, each sensor was calibrated separately with a second order relationship. Sensitivity to shear and eccentric loads was very low. The overall accuracy of the load cell (including non-linearity, and signal drift) was of the order of about 1%.A hip stem instrumented with four such sensors was successfully implanted in a composite femur, yielding meaningful readouts.Thus, this type of sensor can readily be used to assess the cement-prosthesis interface forces in cemented devices.

Biomechanical Phenomena↗

Color doppler ultrasonography imaging to guide transluminal angioplasty of venous stenosis.

BACKGROUND: The objective of access surveillance is the early recognition of dysfunction in order to be able to correct the stenosis by angioplasty or surgery before access thrombosis occurs. The advent of color Doppler imaging has enabled studies of color Doppler ultrasonography (CDU) for the guidance of percutaneous transluminal angioplasty (PTA). The aim of the present study was to investigate whether color Doppler imaging alone can be safely and effectively used to diagnose vascular graft access stenoses and guide subsequent PTA. METHODS: Using the ultrasound velocity dilution method, we measured access blood flow (Qa) during the first hour of hemodialysis every month in patients with grafts as vascular access. When the decrease in Qa from the baseline value was 40% or more, CDU was performed and immediately followed by PTA in the presence of a stenosis of more than 50%. The Qa was then measured during the first dialysis after PTA and one month later. Repeated-measure analysis of variance was applied to evaluate the early and late (after one month) effect of PTA. RESULTS: Twelve PTAs were performed under CDU guidance in nine patients and led to the elimination of the stenosis or its reduction (two cases). The mean Qa was 809 +/- 263 mL/min at baseline, 468 +/- 153 before PTA, and 820 +/- 281 after PTA. The difference between the pre-PTA and post-PTA values was highly significant (P < 0.001), and the mean value after PTA was not different from baseline (P = 0.672). There were no relevant complications directly related to the procedure. CONCLUSIONS: The CDU procedure is effective for the diagnosis of vascular access stenosis and as a guide during the PTA procedure. It could improve stenosis screening by avoiding the risks of exposure to ionizing radiation and of adverse reactions to contrast media.

Aged↗

CT data sets surface extraction for biomechanical modeling of long bones.

In modelling applications such as custom-made implants design is useful to have a surface representation of the anatomy of bones rather than the voxel-based representation generated by tomography systems. A voxel-to-surface conversion process is usually done by a 2D segmentation of the images stack. However, other methods allow a direct 3D segmentation of the CT or MRI data set. In the present work, two of these methods, namely the Standard Marching Cube (SMC) and the Discretized Marching Cube (DMC) algorithms, were compared in terms of local accuracy when used to reconstruct the geometry of a human femur. The SMC method was found to be more accurate than the DMC method. The SMC method was capable of reconstructing the inner and outer geometry of a human femur with a peak error lower than 0.9 mm and an average error comparable to the pixel size (0.3 mm). However, the large number of triangles generated by the algorithm may limit its adoption in many modelling applications. The peak error of the DMC algorithm was 1.6 mm but it produced approximately 70% less triangles than the SMC method. From the results of this study, it may be concluded that three dimensional segmentation algorithms are useful not only in visualisation applications but also in the creation of geometry models.

Algorithms↗

Risk of fracture in elderly patients: a new predictive index based on bone mineral density and finite element analysis.

Hip fracture is more and more frequent in elderly population. For this reason, an increasing attention has been focused on the development of a non-invasive method to predict femoral neck fracture. A conventional approach to fracture diagnosis is the measurement of bone mass by dual-energy X-ray absorptiometry in some regions of interest. The aim of this work is to assess a method that accounts for the structural details of the bone providing a more direct determination of strength properties, and improving the diagnostic power of the current densitometric systems. A 2D finite element model of the proximal femur is derived from dual-energy X-ray absorptiometry data. Initially, the method is validated in vitro using a replica of the human femur. The predicted results are compared to strain-gauge measurements and to a 3D finite element model, with good agreement being observed. Then, an in vivo preliminary study on a limited group of patients is carried out. The loading condition that simulates a fall to the side onto the greater trochanter from standing height is employed. All simulations show a peak strain at the femoral neck region with a strain distribution typical of a fall on the side. The proposed method seems to supply a useful tool for the in vivo analysis of the risk of hip fracture.

Aged↗

Flat foot functional evaluation using pattern recognition of ground reaction data.

OBJECTIVE: Main purpose of this study was to apply quantitative gait analysis and statistical pattern recognition as clinical decision-making aids in flat foot diagnosis and post-surgery monitoring. DESIGN: Statistical pattern recognition techniques were applied to discriminate between normal and flat foot populations through ground reaction force measurements; ground reaction forces time course was assumed as a sensible index of the foot function. BACKGROUND: Gait analysis is becoming recognized as an important clinical tool in orthopaedics, in pre-surgery planning, post-surgery monitoring and in a posteriori evaluation of different treatment techniques. Statistical pattern recognition techniques have been utilized with success in this field to identify the most significant variables of selected motor functions in different pathologies, and to design classification rules and quantitative evaluation scores. METHODS: Ground reaction forces were recorded during free speed barefoot walks on 28 healthy subjects, and 28 symptomatic flexible flat foot children selected for surgical intervention. A new feature selection algorithm, based on heuristic optimization, was applied to select the most discriminant ground reaction forces time samples. A two-stage pattern recognition system, composed by three linear feature extractors, one for each ground reaction force component, and a linear classifier, was designed to classify the feet of each subject using the selected features. The output of the classifier was used to define a functional score. RESULTS: The classifier assigned the ground reaction force patterns performed by each subject into the right class with an estimated error of 15%, corresponding to an assignment error for each subject's foot of 9%. The most discriminant ground reaction forces time samples selected are in full agreement with the pathophysiology of the symptomatic flexible flat foot. The obtained score was utilized to monitor the 1 and 2 years post-operative functional recovery of two differently treated subgroups of 32 flexible flat foot subjects. CONCLUSIONS: Statistical pattern recognition techniques are promising tools for clinical gait analysis; the obtained score provides important functional information that could be used as a further aid in the clinical evaluation of flat foot and different surgical treatment techniques. RELEVANCE: Symptomatic flexible flat foot surgical decision making is frequently difficult because of the lack of objective criteria to assess functional abnormalities of the foot/ankle complex. Gait analysis and statistical pattern recognition can give us parameters with which to characterize "functional" flat foot. Moreover, we can objectively follow up the recovery of the foot/ankle complex function after surgical treatment.

Algorithms↗

A model-based method for the reconstruction of total knee replacement kinematics.

A better knowledge of the kinematics behavior of total knee replacement (TKR) during activity still remains a crucial issue to validate innovative prosthesis designs and different surgical strategies. Tools for more accurate measurement of in vivo kinematics of knee prosthesis components are therefore fundamental to improve the clinical outcome of knee replacement. In the present study, a novel model-based method for the estimation of the three-dimensional (3-D) position and orientation (pose) of both the femoral and tibial knee prosthesis components during activity is presented. The knowledge of the 3-D geometry of the components and a single plane projection view in a fluoroscopic image are sufficient to reconstruct the absolute and relative pose of the components in space. The technique is based on the best alignment of the component designs with the corresponding projection on the image plane. The image generation process is modeled and an iterative procedure localizes the spatial pose of the object by minimizing the Euclidean distance of the projection rays from the object surface. Computer simulation and static/dynamic in vitro tests using real knee prosthesis show that the accuracy with which relative orientation and position of the components can be estimated is better than 1.5 degrees and 1.5 mm, respectively. In vivo tests demonstrate that the method is well suited for kinematics analysis on TKR patients and that good quality images can be obtained with a carefully positioning of the fluoroscope and an appropriate dosage. With respect to previously adopted template matching techniques, the present method overcomes the complete segmentation of the components on the projected image and also features the simultaneous evaluation of all the six degrees of freedom (DOF) of the object. The expected small difference between successive poses in in vivo sequences strongly reduces the frequency of false poses and both the operator and computation time.

Algorithms↗

Global asymptotic stability of bone remodeling theories: a new approach based on non-linear dynamical systems analysis.

Mathematical tools for the analysis of nonlinear dynamical systems are applied to the study of stability of bone remodeling theories. As a practical application, the same problem studied by Harrigan and Hamilton (1992) and Cowin et al. (1994b) is analysed using these tools, and their findings on the necessary and sufficient conditions to ensure local asymptotic stability are easily confirmed. Using a general approach based on Lyapunov's method the same condition has been found to be necessary and sufficient also for the global asymptotic stability, thus confirming a result obtained by Harrigan and Hamilton (1994) by variational methods applied to finite-element models. The proof is based on the discretization of the spatial domain but the results for the continuum can be easily extrapolated.

Animals↗