Continuous plasma filtration coupled with sorbents.

An in vitro system composed of a plasma separation membrane coupled with natural (charcoal) or synthetic (Amberlite, Amberchrome) types of sorbents was evaluated for the simultaneous removal of proinflammatory cytokines (TNF-alpha, IL-1 beta and IL-8) and cytokine antagonists [interleukin (IL)-1 receptor antagonist (IL-1Ra), soluble tumor necrosis factor-alpha (TNF-alpha) receptor I and II (sTNFR I and II)] in whole blood spiked with bacterial lipopolysaccharide (LPS). These studies showed that plasma filtration rather than ultrafiltration significantly increased the clearance of all cytokines, particularly TNF-alpha, and the synthetic (Amberlite-type of resin) but not natural (uncoated charcoal) membrane could extensively absorb almost 100% of plasma filtered IL-Ra, IL-1 beta and IL-8, but only 40% of TNF-alpha. Other synthetic (Amberchrome) membranes could also effectively (80%) remove TNF-alpha. In the complex scenario of sepsis, the simultaneous removal of excess proinflammatory and/or immunomodulatory mediators may play a role in reducing the hemodynamic alterations, thus resulting in enhanced patient survival. Whether this occurs in the human setting awaits the results of an ongoing clinical investigation.

Adsorption↗

Beta 2-microglobulin removal by synthetic dialysis membranes. Mechanisms and kinetics of the molecule.

Beta 2-microglobulin (beta 2-m) accumulation represents a possible complication of long term dialysis. It is therefore important to evaluate the capacity of removal of this molecule from the patient by different dialysis membranes. The present study is aimed at evaluating the mechanisms involved in beta 2-m removal by three different synthetic membranes: a) highly asymmetric hydrophobic polysulfone (Biosulfane, NMC), b) moderately asymmetric and hydrophobic polysulfone (PS600, Fresenius), c) Polyacylonitrile (AN69HF, Hospal). The adsorption capacity and sieving coefficients of the three membranes for native and labeled beta 2-m were studied in vitro utilizing human blood. The amount adsorbed by the membrane was measured by the elution of the molecule obtained with a detergent solution. Clearances, total removal and membrane adsorption were studied in six patients treated in a randomized sequence with the three membranes. For this purpose, plasma and dialysate measurements as well as total collection of spent dialysate and beta 2-m elution from the used dialyzers were carried out. Ex novo generation of beta 2-m did not take place during in vitro circulation. The molecule was removed by the studied membranes both by filtration and adsorption. The Biosulfane membrane removed beta 2-m mostly by adsorption while the PS600 membrane removed beta 2-m almost entirely by filtration. Intermediate behaviour was shown by AN69 membrane. Similar quantities of beta 2-m were removed from the patients with the three membranes. Total removal could only be precisely measured by adding the quantity of beta 2-m eluted from the membrane to the amount recovered in the spent dialysate. Out of total removal, adsorption was more than 90% with Biosulfane, while only 5% with the PS600. These findings contribute to the understanding of the discrepancy found between the clearance measured from the plasma side and that measured from the dialysate side. In conclusion, clearance and sieving measurements for beta 2-m cannot be correctly performed unless the capacity of adsorption of the membrane is taken into account.

Acrylic Resins↗

Impact of spacing filaments external to hollow fibers on dialysate flow distribution and dialyzer performance.

A new type of dialyzer (PAN 650 SF Asahi) is analyzed in terms of hydraulic properties, solute clearances and dialysate flow distribution. The new type of dialyzer is a polyacrylonitrile hollow fiber filter, equipped with spacing filaments placed externally to the fibers to facilitate dialysate distribution and avoid channeling. The new filter is compared with a similar filter without spacing filaments. For this purpose, blood and dialysate side clearances have been measured in sequential dialysis session carried out randomly in the same patients. Furthermore, a last generation helical scanner (X-Press/HS1, Toshiba) has been utilized to analyze in vitro the flow distribution of dialysate inside the dialyzer. A contrast medium was injected and a sequence of images has been achieved on a longitudinal section of the dialyzer. This new method permits to avoid any bias due to the cylindrical shape of the dialyzer, since a 10 mm thick rectangular section is analyzed and not the entire body of the filter. The dialyzers equipped with spacing filaments displayed a significant improvement of the dialysate distribution as demonstrated by the radiological pattern. In detail, despite a channeling phenomenon in the peripherical region of the bundle is still present, this is remarkably reduced in comparison with the channelling phenomenon observed in the standard dialyzers. This improved distribution is confirmed by a significant improvement of the solute clearances.

Dialysis Solutions↗

Treatment of acute renal failure in intensive care patients by continuous arteriovenous hemofiltration (CAVH): two years' experience in two centres.

The study objective was to evaluate the outcome of continuous arteriovenous hemofiltration (CAVH) as a first choice treatment for acute renal failure (ARF) in critically ill intensive care patients in two centres with a long experience in the field of continuous renal replacement therapies. Sixty consecutive intensive-care ARF patients from Uppsala Centre and 71 consecutive ARF patients from Vicenza Centre were included during a period of two years. Their age range was 58 +/- 16 and 52 +/- 15 years in Uppsala and Vicenza, respectively. CAVH was performed in the postdilution form using different types of hemofilters. Three choices of vascular access were utilised in each centre, namely: the Buselmeier shunt, femoral vessel catheter and the Scribner shunt. The pre-treatment serum urea level (mean +/- SD) in the Uppsala patients (30 +/- 14 mmol/l) was significantly higher (p < 0.001) than that of the Vicenza patients (17 +/- 10 mmol/l). The Uppsala patients had a longer treatment duration than the Vicenza patients; 8 +/- 6 vs 5 +/- 5 days (p < 0.05) perhaps because they were much older than the Vicenza patients (p < 0.05) in addition to their multi-organ failure. However, the total outcome of CAVH in the two centers was not significantly different (52 and 58% patient's survival in Uppsala and Vicenza, respectively).(ABSTRACT TRUNCATED AT 250 WORDS)

Acute Kidney Injury↗

On-line urea monitoring: a further step towards adequate dialysis prescription and delivery.

The aim of this study is to present a clinical experience carried out with a new device designed to measure on-line Urea Nitrogen concentration in the effluent dialysate. The Biostat 1000 Urea Monitor (Baxter Healthcare, Dirfield, Ill, USA) was utilized in the present study. The monitor is based on the principle that multiple urea measurements in the dialysate effluent from the dialyzer, permit to built a double exponential regression leading to the urea kinetic parameters of the dialysis session. Data obtained with the Urea Monitor were, in the present study, compared with those obtained by direct measurements carried out in blood and dialysate and by the collection of the whole amount of spent dialysate. The monitor provided an accurate value of predialysis BUN without any blood drawing. Urea kinetics were established from multiple dialysate measurements and no blood drawing was necessary. The double pool kinetics were taken into account and Kt/V, PCR and SRI% obtained were comparable to those obtained from direct measurement. Since a projected value of Kt/V can be obtained, the monitor could represent a potential source of information to detect possible filter and machine dysfunction, as well as high rate of recirculation.

Adult↗

Ultrafiltration and clearance studies in human isolated peritoneal vascular loops.

Eight samples of human peritoneal tissue were obtained from patients undergoing hemicholectomy for cancer. An artery and a vein were cannulated and perfused with blood in vitro with a special circuit able to provide different perfusion pressures. Ultrafiltration and clearance studies were performed in these samples. Both ultrafiltration and small-solute clearances linearly correlated with the blood flow, demonstrating a strong dependence on this parameter. The peritoneal capillary showed a typical filtration pressure equilibrium with a constant filtration fraction at different blood flows. The results suggest that the blood flow may be a factor limiting the efficiency of peritoneal dialysis both in terms of mass transfer coefficients and maximal ultrafiltration rates.

Blood↗

Changes in the peritoneal equilibration test in selected chronic peritoneal dialysis patients.

Fifty-five patients on chronic peritoneal dialysis with two or more peritoneal equilibration tests (PET) performed between 1983 and 1992 with a mean interval of 21.9 +/- 22.7 months were studied retrospectively. Repeated PET were performed when transport changes were suspected rather than routinely. According to the initial PET, there were 16 high (HI), 17 high-average (HA), 15 low-average (LA), and 7 low (LO) transporters. There was a significant decrease in the mean creatinine dialysate to plasma ratio (D/P creatinine) in the HI transporters and an increase in the LA and LO transporters. The mean dialysate to instilled glucose ratio (D/Do) significantly increased in the HI transporters. The change in both the D/P creatinine and the D/Do of an individual strongly and inversely correlated to their respective initial values. The change in D/P creatinine and D/Do were significantly and inversely correlated to each other, indicating an actual transport change. No correlation was found between the change in transport with peritonitis episodes or frequencies. The centripetal [corrected] change of transport toward average described here may explain why low clearances or low ultrafiltration rates due to rapid transport are infrequent causes of peritoneal dialysis technique failure, and why patients who have been dialyzed for a long period are usually HA transporters.

Biological Transport, Active↗

Double pass dialysis: a new method of renal replacement in patients with malfunctioning vascular access.

Several patients undergoing chronic renal replacement therapy present problems related to their vascular access. Low blood flows and high rates of recirculation are common in such patients in which, for this reason, it becomes difficult to apply highly efficient techniques or techniques where diffusion and convection are combined as in hemodiafiltration. In these patients we studied the possibility of partially recirculating the blood in the extracorporeal circuit in order to increase the flow rate per single hollow fiber; we defined our system "double pass dialysis". We evaluated the system's efficiency in 12 patients during 24 dialysis sessions: 12 high flux dialysis sessions (without reinfusion) and 12 hemodiafiltration sessions (9 liters reinfusion). Different surfaces of polyacrylonitrile dialyzers were utilized (1.3-1.7-2.1 sqm) at 250 and 350 ml/min of blood flow with or without 100 ml/min of recirculation. During each dialysis session blood and dialysate samples were taken in order to calculate BUN, Creatinine, Phosphate and Inuline clearances from both the blood and dialysate side. The clearances of low molecular weight solutes were not really influenced by the artificial increase of the blood flow, but on the other hand, the clearances of higher molecular weight solutes increased from 10 to 30% during both high flux dialysis and hemodiafiltration with recirculation. This increase was evident mostly in hemodiafiltration suggesting that the cleaning effect on the membrane has a positive impact on the permeability. The good clinical results obtained with the double pass dialysis show that the system is safe and reliable and may become a valid support in critical situations in order to reach adequate dialysis treatment.

Adult↗

A new blood module for continuous renal replacement therapies.

A new blood module for continuous renal replacement therapies has been utilized to perform CVVH in critically ill patients. The features of the new module named (HP300 and manufactured by Medica srl (Medolla, Modena) are the easy installation and transportability to the bedside, the simple and safe management and the continuous measurement of the pre and post filter pressure with automatic calculation of the end-to-end pressure drop inside the filter. The last feature permits to detect early malfunctions of the filter due to fibers clotting or due to the internal coating of the hollow fibers by plasma proteins. In both cases the efficiency of the treatment can be reduced because of a significant reduction of the ultrafiltration rates or a remarkable decay of the membrane permeability and solute sieving coefficients. In many cases this reduction is only detected when important effects on solute removal have already occurred. In our experience, the new module permitted the substitution of the filters when early malfunctions were detected and maximal treatment efficiency was therefore guaranteed over extended periods of time.

Hemofiltration↗

Technical and clinical evaluation of a new asymmetric polysulfone membrane (Biosulfane).

First generation asymmetric polysulfone membranes had high hydraulic permeability (kf = 40 ml/h/mmHg/sqm) but a low diffusive permeability due to the hydrophobic nature and wall thickness of 75-100 microns. We have tested a new polysulfone membrane with a wall thickness of 40 microns in a series of in vitro and in vivo dialysis session experiments. The new "Biosulfane" membrane presented a Kf of 45.8 with constant performance up to 240 mins. The koA was 760 and the clearance value at 350 ml/min of Qb in hemodiafiltration was 255 ml/min for urea, 210 for creatinine, 225 for phosphate, 76 for inulin. In high flux dialysis the clearances were similar except for inulin which was 32% lower due to the lower convection amount. Beta-2 microglobulin clearance was 22 ml/min in high flux dialysis and 37 in hemodiafiltration. Solute sieving coefficients were close to 1 for the majority of the studied solutes in a wide range of molecular weights and slight variations were observed for charged solutes due to Donnan's effect. The sieving for Inulin was 0.96 while that for Beta-2 microglobulin was not measurable due to a large molecule adsorption on the inner structure of the fibres. The good performances of this membrane are probably due to reduced wall thickness and a consequent improvement in diffusive permeability to small size solutes.

Blood Urea Nitrogen↗

A new scintigraphic method to characterize ultrafiltration in hollow fiber dialyzers.

Ultrafiltration and pressure profiles in hollow fiber dialyzers with different hydraulic permeabilities have been investigated with a new scintigraphic method. Radiolabelled albumin macroaggregates, used as a nondiffusible marker molecule, were added to the blood in an in vitro circuit and circulated through cuprophan and polysulphon dialyzers. Since the marker molecule was too big to cross the dialysis membrane, its changes in concentration were assumed to occur in response to the variation of the blood water content (filtration or back-filtration). These changes in concentration, recorded by a gamma camera, were evaluated to establish the cumulative values of filtration and back-filtration and their relevant profiles along the length of the dialyzer. The achieved data were compared with the experimental values of ultrafiltration empirically measured and with the theoretical values predicted by a classic linear method. Two conditions were analyzed: A) the minimal filtration rate necessary to avoid back-filtration (critical filtration); and B) the condition of zero net filtration in which filtration equals back-filtration. The nuclear method proved to be extremely precise in predicting the ultrafiltration values and significantly more precise than the linear method, especially for the highly permeable dialyzer. The reason for that probably depends on the non-linear pressure and ultrafiltration profile observed with the scintigraphic pattern of the dialyzer. Viscosity changes and local variations in blood flow may in fact interfere with the pressure drop inside the hollow fibers and result in such a complex behavior. The other interesting aspect of this method is the possibility of accurate measurement of the amount of back-filtration that wouldn't be possible with simple calculations. In conclusion, the complex nature of the phenomena regulating the water fluxes in hollow fiber dialyzers requires more complex calculation than a simple linear model to achieve an accurate range of predictability.

Biophysical Phenomena↗