Dialysate flow distribution in hollow fiber hemodialyzers with different dialysate pathway configurations.

UNLABELLED: The efficiency of a hemodialyzer is largely dependent on its ability to facilitate diffusion, since this is the main mechanism by which small solutes are removed. The diffusion process can be impaired if there is a mismatch between blood and dialysate flow distribution in the dialyzer. The objective of the paper was to study the impact of different dialysate compartment designs on dialysate flow distribution and urea clearances. Eighteen hollow fiber 1.3 m2 hemodialyzers were studied, 6 each of 3 designs: Type A--standard fiber bundle (PAN 65DX Asahi Medical, Tokyo, Japan); Type B--spacing filaments external to the fibers (PAN 65SF Asahi Medical, Tokyo, Japan); Type C--fibers waved to give Moiré structure (FB130 Nissho-Nipro, Osaka, Japan). IN VITRO STUDIES: 3 dialyzers of each type were studied following dye injection into the dialysate compartment. Dynamic sequential imaging of longitudinal sections of the dialyzer were undertaken, using a new generation helical CT scanner (X-Press/HS1 Toshiba Corporation, Tokyo, Japan). In vivo studies: 3 dialyzers of each type were studied, in randomized sequence, in 3 different patients under standardized dialysis conditions. Blood- and dialysate-side urea clearances were measured at 30 and 150 minutes of treatment. Macroscopic and densitometrical analysis revealed that flow distribution was most homogeneous in the dialyzer with Moiré structure (Type C) and least homogeneous in the standard dialyzer (Type A). Space yarns (Type B) gave an intermediate dialysate flow distribution. Significantly increased urea clearances (p<0.001) were seen with Types B and C, compared to the standard dialyzer. Type C (Moiré) had the highest clearances although these were not significantly greater than Type B (space yarns). In conclusion, more homogeneous dialysate flow distribution and improved small solute clearances can be achieved by use of spacing yarns or waved (Moiré structure) patterns of fiber packing in the dialyzer. These effects are achieved probably as a result of reduced dialysate channeling resulting in a lower degree of mismatch between blood and dialysate flows. The new radiological technique using the helical CT scanner allows detailed flow distribution analysis and has the potential for testing future modifications to dialyzer design.

Equipment Design↗

A non-parametric method for the analysis of experimental tumour growth data.

Analysis of tumour growth is required to investigate the biology of tumours and to determine the effects of new anti-tumour therapies. A non-parametric mathematical method for the analysis of a set of experimental tumour growth data is described. The method is based on the similarity between time series of tumour size measurements (e.g. tumour volume), similarity being defined as the Euclidean distance between data measured for each tumour at the same time. Subsets of similar time series are found for a given population of tumours. A biologically meaningful parameter H has been derived which is a measure of the scattering of experimental volume samples. The method has been applied to the analysis of the growth of (i) untreated multicellular tumour spheroids obtained with different cell lines and (ii) spheroids treated with cytotoxic drugs (immunotoxins). Results are compared with those previously obtained by applying the classical Gompertz growth model to the analysis of treated and untreated spheroids.

Animals↗

New perspectives in the treatment of acute renal failure.

The evolution of technology and biomaterials has permitted a parallel development of renal replacement therapies in the acute, critically ill patient. From the original description of continuous arterio-venous haemofiltration, new techniques such as continuous veno-venous haemofiltration, haemodiafiltration and high flux dialysis have been developed and clinically utilised. A parallel improvement in efficiency has been achieved with urea daily clearances as high as 50 litres or more. The use of special highly permeable dialysers has also permitted to increase the clearances of larger solutes thus leading to significant removals of chemical substances involved in the acute inflammation and sepsis. In this field, recent observations have suggested to use haemofiltration with high volumes of fluid exchange. The hardware and software of the newer continuous renal replacement therapies (CRRT) are certainly the key point in achieving these results and in safely performing such challenging techniques.

Acute Kidney Injury↗

Oscillating growth patterns of multicellular tumour spheroids.

The growth kinetics of 9L (rat glioblastoma cell line) and U118 (human glioblastoma cell line) multicellular tumour spheroids (MTS) have been investigated by non-linear least square fitting of individual growth curves with the Gompertz growth equation and power spectrum analysis of residuals. Residuals were not randomly distributed around calculated growth trajectories. At least one main frequency was found for all analysed MTS growth curves, demonstrating the existence of time-dependent periodic fluctuations of MTS volume dimensions. Similar periodic oscillations of MTS volume dimensions were also observed for MTS generated using cloned 9L cells. However, we found significant differences in the growth kinetics of MTS obtained with cloned cells if compared to the growth kinetics of MTS obtained with polyclonal cells. Our findings demonstrate that the growth patterns of three-dimensional tumour cell cultures are more complex than has been previously predicted using traditional continuous growth models.

Animals↗

Present and future options in continuous renal replacement therapies of sepsis and MOF.

Conventional continuous extracorporeal treatments such as hemofiltration and hemodiafiltration have not achieved significant reduction in cytokine plasma levels, in spite of their increasing popularity mainly related to the unnecessary fluid restriction thereby rendering adequate caloric intake possible (Actualités Nephrologiques, 1994). This is mainly due to reduced filtration, to saturability of the adsorption-related phenomena and to the absence of a convective mass transfer. New approaches have been more recently introduced. The concept of blood purification has been applied in some new innovative techniques that use non-selective or selective sorbents. We will focus on the criteria used by others and us to assess the efficiency in vitro and in animal models of sepsis of more recently introduced non-selective and selective devices. Among the innovative techniques, modalities aimed at the plasma treatment will receive emphasis. These modalities that are based on plasma filtration with the use of different sorbents. The preliminary results obtained from ongoing clinical trials will be presented. We will also expand on the technical, biological and clinical aspects that should be addressed in order to establish a new modality as innovative in the treatment of sepsis.

Hemofiltration↗

In vitro and in vivo evaluation of a new polysulfone membrane for hemodialysis. Reference methodology and clinical results. (Part 1: in vitro study).

Different high flux membranes have been recently developed. The present study is aimed at describing the technical features and the clinical performances of a new high flux polysulfone membrane (T-sulfone, Toray, Japan). The study has been carried out on two different dialyzers (surface area = 1.3 and 1.8 m2). The filters have been tested in vitro under definite experimental conditions. The hydraulic flow resistance, the pressure drop in the blood compartment and the hydraulic permeability have been determined in a wide range of in vitro experimental conditions. The in vitro sieving coefficients for various solutes have also been determined utilizing human blood. Hydraulic permeability was found in the range of 28.4 ml/h/mm Hg/m2 and sieving coefficients were between 0.96 and 1.0 for all low molecular weight solutes. The sieving coefficient for inulin was 0.95. The pressure drop in the filter at 300 ml/min of blood flow was 95 mm Hg for the 1.3 m2 and 57 mm Hg for the 1.8 m2. The filters are then designed to operate in the presence of high blood flows without excessive resistance in the blood compartment. The blood compartment analyzed by means of a special radiological sequence obtained with a helical scanner after dye injection confirmed the homogeneous distribution of the blood flow in several cross sections of the bundle. Adequate distribution of dialysate was confirmed with a similar method applied to the dialysate compartment. The new imaging techniques utilized were greatly helpful to determine adequacy of filter design and flows distribution.

Biocompatible Materials↗

In vitro and in vivo evaluation of a new polysulfone membrane for hemodialysis. Reference methodology and clinical results. (Part. 2: in vivo study).

Different high flux membranes have been recently developed. The present study is aimed at describing the technical features and the clinical performances of a new high flux polysulfone membrane (T-sulfone, Toray, Japan). The study has been carried out on two different dialyzers (surface area = 1.3 and 1.8 m2). The filters have been tested in vivo during hemodialysis and hemodiafiltration. The in vivo study was carried out on 12 ESRD patients on regular hemodialysis treatment. The protocol was reviewed and approved by the local ethical committee. The in vivo clearances (K) at 300 ml/min of blood flow are reported in the following Table: [Table in text]. Beta-2-m reduction ratio exceeded 50% in all sessions. Beta-2-m mass balance executed by collection of spent dialysate and elution from the used filters evidenced that removal is obtained mostly by filtration while absorption is negligible. Excellent tolerance and hemocompatibility was observed in all the studied sessions.

Adsorption↗

Online monitoring in continuous renal replacement therapies.

Technical improvements in dialysis equipment for chronic hemodialysis patients has mirrored improvements in continuous renal replacement therapies (CRRTs) for patients with acute renal failure who are critically ill. This article reviews the available types and importance of online monitors such as urea sensors to provide real-time urea kinetic parameters, temperature sensors to target thermal balance throughout each session, conductivity measurement of sodium balance in the dialysate, blood volume monitoring to aid against cardiovascular instability and treatment-induced hypotension, biofeedback systems, and remote dialysis/teledialysis for efficient use of trained personnel.

Biosensing Techniques↗

Use of adsorptive mechanisms in continuous renal replacement therapies in the critically ill.

The pathophysiology of sepsis is becoming a more complicated scenario. In sepsis, endotoxin or other gram-positive derived products induce a complex and dynamic cellular response giving rise to several mediators known to be relevant in the pathogenesis of septic shock, such as specific mediators. substances responsible for up- or down-regulation of cytokine receptors and cytokine antagonists, inactivators of nuclear factor-kappaB or signal transduction pathways, and precursor molecules. In this article, we delve into some new concepts stemming from the use of sorbents in continuous plasma filtration. The rationale is based on the assumption that the nonspecific removal of several mediators of the inflammatory cascade and cytokine network may improve outcome in a rabbit model of septic shock and hemodynamics in a pilot clinical study. The importance of looking for innovative treatments specifically targeted for the special needs of the critically ill patients rather than using concepts and technology applied to the treatment of chronic renal failure is underlined.

Animals↗

Enhancement of convective transport by internal filtration in a modified experimental hemodialyzer: technical note.

BACKGROUND: Hemodialysis using high flux membranes today is a commonly used therapy. The primary advantage is the larger spectrum of molecules removed with these membranes, and the mechanism of removal is in part due to a phenomenon of filtration and backfiltration along the length of the hollow fibers. We hypothesized that increasing the filtration and backfiltration fluxes by modifying the structure of the dialyzer could enhance the convective transport of various solutes. METHODS: A modified high flux dialyzer was compared to the standard model in terms of pressure profiles, filtration-backfiltration rates and solute clearances. The modification consisted on the placement of a O-ring around the fiber bundle to create a resistance for the flow of the dialysis solution external to the fibers. The study on filtration fluxes was carried out using a scintigraphic method previously described, and solute clearances were studied during ultrafiltration-controlled hemodialysis sessions. RESULTS: Utilizing a net filtration condition proximal to zero, the rates of proximal filtration and distal backfiltration in the experimental dialyzer were significantly enhanced in comparison with the standard dialyzer. The pressure drop in the dialysate compartment could be increased significantly, thus permitting an increase in the positive transmembrane pressure in the first half of the dialyzer and a parallel increase in the negative transmembrane pressure in the second half of the dialyzer. This resulted in a significant enhancement of the convective transport of middle-large solutes as demonstrated by the increase in vitamin B12 and inulin clearances. CONCLUSIONS: This approach suggests that changes in design of the dialyzer may affect its performance. The use of internal filtration is suggested to improve convection and dialyzer efficiency for larger solutes without the requirement for high volumes of replacement fluid, as is the case for current hemodiafiltration techniques.

Hemodiafiltration↗

Chronic renal replacement therapy in children: which index is best for adequacy?

BACKGROUND: The dialysis dose, Kt/V, and Solute Removal Index (SRI) have been proposed as tools to measure and compare adequacy of different renal replacement therapies in adults. The aim of our study was to elucidate whether the Kt/V and SRI could be appropriate parameters to compare different treatments and define adequacy targets in children. METHODS: Twenty-two pediatric chronic dialysis patients (2 to 17 years) were prospectively studied. Six patients were on continuous ambulatory peritoneal dialysis (CAPD), 7 patients were on automatic nightly peritoneal dialysis (ANPD), and 9 were on hemodialysis (HD). Patients had no peritonitis and were not hospitalized during the previous two months and, as proved by growth and subjective well being, were in steady state condition at the initiation of the protocol. As a consequence, the treatment delivered was assumed to be adequate and the prospective analysis was carried out within one month. Urea levels in dialysate, plasma and urine were measured to determine urea kinetics and measure adequacy parameters. RESULTS: Instantaneous urea clearance was much higher when hemodialysis was used (124.67 +/- 32.04 ml/min) compared to CAPD (2.79 +/- 0.29 ml/min) and ANPD (6.60 +/- 1.42 ml/min), as expected. The Urea dialytic clearance per week was greater in HD (67320 +/- 17299 ml) than in CAPD(28144 +/- 2895 ml) and ANPD (29910 +/- 4234 ml). Residual renal function contributed to the overall weekly clearance by 47% in CAPD, while it was only by 19% in HD and 26% in ANPD. The overall weekly clearance was therefore 79,842 ml/week in HD, 53,340 ml/week in CAPD and 41,012 ml/week in ANPD. Weekly dialytic Kt/V results were much higher in HD (3.75) than in CAPD (1.78) and ANPD (2.37). To these values, the renal Kt/V was added, reaching the values of overall (dialytic + renal) weekly Kt/V of 4.53 in HD, 3.41 in CAPD and 3.41 in ANPD. Although higher Kt/V values were observed in HD, when the SRI % was considered, HD appeared to be less efficient compared with the other two techniques. Since postdialytic rebound in HD patients averaged 22.5%, we may speculate that hemodialysis in children is less efficient than continuous or daily peritoneal dialysis because of a remarkable cardipulmonary recirculation and solute sequestration. CONCLUSION: In the global evaluation, dialysis SRI% appears to be more reliable as an index of adequacy compared to Kt/V in children. At least an integration between the two indices is strongly recommended.

Adolescent↗