Search PubMedSearch

SEARCH · Search PubMed

Results for “powered mobility devices”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

269 recordsLinked to original sources

Comparison of three tracking methods to assess usage of two pediatric powered mobility devices for young children with cerebral palsy.

Powered mobility devices are underutilized for promoting self-initiated mobility in young children with cerebral palsy due to prioritization of walking, caregiver effort, device characteristics, and environmental factors. Understanding device usage patterns is important to assess the impact of powered mobility interventions on child outcomes. As part of clinical trial (NCT04684576), three objective tracking methods including integrated loggers, Global Positioning System trackers (GPST), and caregiver reported activity logs (CRAL) were compared to provide insights into device usage patterns. Metrics included play session frequency, session duration, total usage minutes, and unique usage days for two powered mobility devices: Modified Ride-on Cars (MROC) and the Permobil Explorer Mini (EM). Twelve children with cerebral palsy used each device for eight consecutive weeks in home and community settings (16 weeks total), with device ordered randomized. Results showed no significant differences among tracking methods for the MROC. For the EM, only session duration differed between GPST and CRAL. Correlation analysis revealed variable relationships amongst tracking methods for both devices. The EM was used more frequently than the MROC, with significantly greater total usage minutes and session duration via CRAL, not GPST. The findings highlight the need for reliable tracking technologies that can be used across powered mobility devices.

Child, Preschool

Effectiveness and usability of artificial intelligence-powered assistive technologies in Supporting daily activities of children with cerebral palsy: a systematic review.

BACKGROUND: Cerebral Palsy (CP) is the main cause of motor disabilities in childhood, necessitating innovative approaches to rehabilitation and assistive technology (AT). Simultaneously, artificial intelligence (AI) is increasingly being integrated into devices to create more adaptive, personalized, and effective AT. This systematic review aimed to evaluate the effectiveness and usability of AI-powered assistive technologies designed to support daily activities and rehabilitation in children with CP. MATERIALS AND METHODS: Five databases, including Scopus, Web of Science, PubMed, Embase, and IEEE Xplore, were systematically searched, and 23 articles were included in the final analysis. Articles were identified, selected, and categorized into emerging thematic areas based on the primary function and application of the technology. RESULTS: Five key thematic topics were identified: 1) AI-driven motor rehabilitation and gait training for functional mobility; 2) intelligent assessment and monitoring systems for clinical decision support; 3) AI-supported communication, social interaction, and intention recognition tools; 4) gamified and virtual reality-based interventions to enhance engagement and usability; and 5) smart assistive systems supporting daily living and independent mobility. The findings demonstrate a strong trend toward the application of AI technologies in personalized, engaging, and data-driven interventions for children with CP. However, the field is predominantly in the proof-of-concept stage, with limitations including small sample sizes, lack of long-term clinical validation, challenges in user-centered design, and usability for children with CP. CONCLUSION: AI-powered assistive technologies hold significant potential for transforming the care of children with CP by enabling highly personalized and engaging interventions. To actualize this potential, future work must realize that practical application remains challenging owing to limited clinical validation, technological integration, and usability barriers for children with CP. Future research must prioritize user-centered design and multidisciplinary collaboration to ensure that AI and robotic advancements improve the usability and quality of life for children with CP.

Humans

User Engagement and Feature Preferences in an AI-Powered mHealth Intervention for Diabetes Prevention: Secondary Analysis of a Randomized Controlled Trial.

BACKGROUND: Prediabetes is highly prevalent and increasing globally, yet lifestyle interventions remain underused. AI-driven mobile health (mHealth) tools can help scale diabetes prevention efforts, but the key factors driving their success are not well understood. OBJECTIVE: This post hoc secondary analysis of a randomized controlled trial (RCT) aimed to characterize the most valued features and the role of user engagement in outcomes of a fully automated mHealth intervention for diabetes prevention. METHODS: Data from 151 participants with prediabetes and overweight or obesity who were assigned to an AI-based diabetes prevention program (Sweetch) in a parent RCT (NCT05056376) were analyzed. Engagement (defined as the total number of days the app was used) was categorized into tertiles (low, medium, and high). Baseline characteristics were compared across engagement groups using ANOVA, Kruskal-Wallis, and chi-square tests, and regression models assessed the association between engagement and achievement of diabetes risk reduction outcomes (&#x2265;5% weight loss, &#x2265;4% weight loss with &#x2265;150 min/week of physical activity, or &#x2265;0.2 percentage point reduction in hemoglobin A1c [HbA1c] at 12 months). Perceived usefulness of intervention features was surveyed at 12 months. RESULTS: Median engagement was 98 (IQR 34-232) days. Older age (P<.001) and lower baseline BMI (P=.04) were significantly associated with higher engagement. Compared with low engagement, high engagement was associated with greater odds of achieving the composite diabetes risk reduction outcome (odds ratio [OR] 2.59, 95% CI 1.11-6.01; P=.03), &#x2265;5% weight loss (OR 3.31, 95% CI 1.16-9.42; P=.03), and &#x2265;0.2 percentage point reduction in HbA1c (OR 3.57, 95% CI 1.19-10.75; P=.02). Participants most frequently rated weight tracking, physical activity tracking, and the digital body weight scale as the features that were most helpful for achieving their health goals. CONCLUSIONS: Higher engagement with an AI-driven intervention requiring no human intervention was associated with improved diabetes risk reduction. Contrary to concerns about lower digital literacy, older adults engaged with the intervention more than younger adults. Features related to weight and physical activity tracking were most valued by patients in the program. TRIAL REGISTRATION: ClinicalTrials.gov NCT05056376; https://clinicaltrials.gov/study/NCT05056376.

Humans

The effect of dietetic counseling combined with digital tools intervention on hemodynamic markers in Greek adults: The GATEKEEPER Study.

BACKGROUND AND AIM: Hypertension is a leading cardiovascular risk factor with substantial global impact on morbidity, mortality, and healthcare costs. While lifestyle interventions remain central to management, mHealth technologies offer promising adjunctive support, though their clinical effectiveness remains uncertain. This study evaluated whether combining dietetic counseling with digital tools improves hemodynamic markers in adults aged &#x2265;55 years with increased cardiometabolic risk. METHODS AND RESULTS: This 3-month RCT (NCT05031299) included 954 adults with at least one metabolic syndrome risk factor, allocated 1:1:1 to Standard Care (dietetic counseling), Platform (counseling plus web-based platform), or Platform&#xa0;+&#xa0;Devices (counseling plus platform plus wearables). Outcomes included anthropometrics, lifestyle characteristics, blood pressure, pulse pressure, and estimated pulse wave velocity, analyzed using linear mixed-effects models adjusted for age and sex. All groups improved over 3 months. Waist circumference decreased by -6.29, -4.92, and -4.69&#xa0;cm across Standard Care, Platform, and Platform&#xa0;+&#xa0;Devices groups respectively, and systolic blood pressure declined by -4.84 to -7.15&#xa0;mmHg across groups. The Platform&#xa0;+&#xa0;Devices group showed greater increases in physical activity (94.62 MET-min/week; 95% CI 66.49 to 122.76) and greater reductions in pulse pressure (-3.90&#xa0;mmHg; -6.58 to -1.22) versus Standard Care. Weight loss was associated with lower odds of hypertension (OR 0.4; 95% CI 0.2-0.7), greater likelihood of hypertension reversal (OR 3.6; 1.2-10.3), and higher probability of achieving normal pulse pressure (OR 1.8; 1.1-3.1). CONCLUSIONS: Dietary lifestyle intervention improved cardiometabolic outcomes, with limited added benefit from digital tools. Weight loss was the primary driver of hemodynamic improvement.

Aged

Analyzing the impact of subcutaneous injection needle, device, and administration characteristics on patient pain, anxiety, and safety: a systematic literature review.

The subcutaneous (SC) injection route is a commonly used and important method for therapeutic delivery of a wide range of compounds, and needle characteristics have a significant influence on patient pain, anxiety, safety, and other outcomes. This systematic review evaluates the evidence on how needle-specific characteristics (e.g. gauge, length, tip design, wall thickness, concealment) and administration- or device-related factors can affect patient-reported outcomes and clinical safety indicators during and following SC injections. A comprehensive search was conducted in MEDLINE, PubMed, Embase, and ClinicalTrials.gov in June 2024. Studies were included if they assessed the relationship between needle characteristics and pain, anxiety, safety, or related outcomes in individuals receiving SC injections. A dual-reviewer process was used for study selection, data extraction, and quality assessment. Sixty-two studies met inclusion criteria. Evidence consistently indicated that thinner and shorter needles reduced patient-reported pain and adverse events such as bruising and bleeding. Tapered and lubricated needles, hidden or retractable needle designs, and use of autoinjectors or prefilled syringes also contributed to reduced anxiety and improved user satisfaction. However, results were heterogeneous, and many studies lacked sufficient power or single-variable evaluation of individual needle parameters, limiting definitive conclusions. Needle characteristics significantly influence patient experience and safety with SC delivery. While both clinical evidence and practical experience clearly favor thinner, shorter, and concealed needles, further standardized, high-quality research is needed to isolate and quantify the specific contributions of individual needle characteristics to optimize injection practices and support patient-centered device design.

Humans

Adding Rib Mobilization to Diaphragm Release Techniques in Patients With Non-Specific Neck Pain: Randomized Controlled Trial.

BACKGROUND: Non-specific neck pain (NSNP) is a frequent issue that can negatively affect both mobility and function. Recently, there has been growing interest in newer therapeutic approaches, including rib mobilization and diaphragm release techniques, as potential ways to address NSNP and support better outcomes for those affected. PURPOSE: To find out the immediate effects of how (DRT) combined with (RMT) affects the level of pain and the extent to which patients' functional abilities are improved in cases of NSNP. METHODS: For this prospective RCT, 96 participants aged 20 to 45&#xa0;years were randomly assigned to one of three equal groups based on their pain score (VAS). Group B engaged in (DRT) for 40&#xa0;minutes, three times weekly for 8&#xa0;weeks, in contrast to Group A, which got both RMT combined with DRT. Group C (active control) received advice and some exercises. Measurements were collected before and after the intervention; the primary outcomes included pain severity, evaluated using a visual analog scale (VAS); active neck range of motion (ROM), measured with a cervical range of motion (CROM) device; and neck flexion endurance. Additionally, the secondary outcome of neck-related disability was assessed using the Neck Disability Index (NDI). RESULTS: No statistically significant difference was identified among the three groups at baseline; nevertheless, a treatment effect emerged after 8&#xa0;weeks (p&#xa0;=&#xa0;0.001 and f-value&#xa0;=&#xa0;4.15, &#x19e;2&#xa0;=&#xa0;0.306). A statistically significant time-treatment interaction was seen when comparing the pre- and post-treatment periods in groups A and B (p&#xa0;=&#xa0;0.001, f-value&#xa0;=&#xa0;3.16, &#x19e;2&#xa0;=&#xa0;0.251). CONCLUSION: The addition of rib mobilization to diaphragm release techniques in patients with non-specific neck pain resulted in statistically significant improvements in pain intensity, cervical flexion, right lateral rotation, left lateral rotation, right rotation, and neck flexor endurance, with moderate to large effect sizes for pain reduction and cervical motion. However, no statistically significant differences were observed between groups for cervical extension, left rotation, or the Neck Disability Index (NDI), and only a marginal clinical improvement in NDI was noted in Group A. The observed benefits in the combined intervention group may not be attributable solely to rib mobilization. The increased treatment complexity and greater therapist interaction inherent in the combined approach could also have influenced the outcomes. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT07133646.

Humans

Smart crutch tipsTM real-time feedback improves adherence to partial weight-bearing protocols following lower extremity fracture surgery: a pilot study.

PURPOSE: To evaluate the effectiveness of Smart Crutch Tips&#x2122; in promoting adherence to prescribed early partial weight-bearing (PWB) protocols and to assess patient experience with real-time weight-bearing feedback during home rehabilitation. METHODS: Twenty patients with lower extremity fractures prescribed partial weight-bearing (PWB) were randomized into two groups utilizing real-time feedback crutch tips (RFC). The Intervention group (n&#x2009;=&#x2009;10) used Smart Crutch Tips&#x2122; (ComeBack Mobility Inc., Kiev, Ukraine), which provided real-time feedback on weight-bearing compliance. The Control group (n&#x2009;=&#x2009;10) also used crutches equipped with Smart Crutch Tips&#x2122;, but notifications were disabled, allowing passive data collection without patient feedback. Weight-bearing compliance was defined as the percentage of steps within &#xb1;&#x2009;10% of the prescribed target. Secondary outcomes included patient satisfaction and device usability assessed using the System Usability Scale (SUS) throughout the home rehabilitation period. RESULTS: The Intervention group demonstrated significantly greater PWB compliance compared with the Control group (73.6% vs. 21.1%, p&#x2009;<&#x2009;0.01). The Intervention group reported a mean SUS score of 84.25, indicating excellent usability. No device-related complications or adverse events were observed. Patient satisfaction, assessed through video interviews, was high, with participants in the Intervention group expressing a strong willingness to recommend the device to others with similar injuries and rating it 10 out of 10. CONCLUSION: Smart Crutch Tips&#x2122; significantly improved adherence to prescribed partial weight-bearing protocols following lower extremity fracture surgery. The RFC device demonstrated high usability, excellent patient satisfaction, and no device-related complications during home rehabilitation throughout the study period.

Humans

A Multimethod Evaluation to Assess Feasibility, Acceptability, and Preliminary Efficacy of HPVVaxFacts, a Tailored Mobile Web App, for Parents With Unvaccinated Children: Pilot 2-Arm Randomized Controlled Trial.

BACKGROUND: Mobile health (mHealth) interventions may improve provider-parent communication on human papillomavirus (HPV) vaccination to reduce concerns, and increase intention and uptake. HPVVaxFacts (233 Analytics) is a novel, mobile web app delivering tailored education based on the Health Belief Model and Theory of Reasoned Action, addressing parental concerns preclinic visit. OBJECTIVE: This study aimed to assess the feasibility, acceptability, and preliminary efficacy of HPVVaxFacts among parents of adolescents aged 9-17 years. METHODS: We conducted a pilot, randomized controlled trial in 2 urban Tennessee clinics from June to September 2023 comparing 2 groups: tailored education via HPVVaxFacts mobile web app (intervention, n=27), and nutrition education (attention control, n=30). Eligible parents had or were caregivers to a child aged 9 to 17 years unvaccinated against HPV, had a mobile phone, had an upcoming clinic visit, and spoke English. The recruitment strategy was patient intake software-Phreesia (Phreesia, Inc) and eClinicalWorks (eClinicalWorks). Although unblinded, parents could deduce their study arm assignment. Providers were blinded. Feasibility, acceptability, and preliminary efficacy (HPV vaccine knowledge, concerns, intentions, and vaccination rates) were assessed using multimethod evaluation. Parents were assessed at baseline and immediately post intervention via surveys. Vaccination rates were assessed at 12 months post intervention via electronic health records. Nineteen parent interviews were conducted up to 9 months post intervention. A clinic staff consultation (n=6) was 1 month post intervention. RESULTS: Of 57 enrolled parents, most were female (52/57, 91%), non-Hispanic White (44/57, 77%), had &#x2264;US $80,000 household income (32/57, 56%), and had some college or less (27/57, 47%). In total, 81% (29/36) of parents viewed HPVVaxFacts. Post intervention, HPV vaccine initiation was higher in the intervention group compared to the attention control group (48% vs 17%; difference 0.24; 95% CI 0.03-0.46; P=.01). Parents in the HPVVaxFacts arm demonstrated a greater reduction in knowledge (ie, knowledge increase; mean change: -0.6 vs 0.1) and concern scores (mean change: -3.4 vs -1.4) than those in the nutrition education arm. However, between-arm differences were not statistically significant (P=.13 and P=.14, respectively). The majority found the study protocol and HPVVaxFacts acceptable. Benefits of HPVVaxFacts include confirming their decision to vaccinate, supporting parent-child discussion on the vaccine, and answering questions preclinic visit or offering questions for the provider. Study protocol delivery and mobile web app instructions were suggested areas for improvement. Barriers for HPVVaxFacts use include content in English only and digital format. CONCLUSIONS: Our study suggests HPVVaxFacts was feasible and acceptable among parents to provide previsit, tailored information on HPV vaccination. Outcomes offer a positive trajectory but need more exploration. Next steps include a well-powered efficacy trial to determine the impact of HPVVaxFacts on initiation vaccine rates and parental hesitancy factors, as well as to explore an interaction, effect modification, and mediation among different variables.

Humans

Use of Wearable Sensors in Angelman Syndrome: A Systematic Review.

BACKGROUND: Wearable sensors are a promising method for collecting clinical trial outcome data for people with Angelman syndrome (AS). However, there has yet to be a systematic probe into the ways in which wearable sensors have been successfully used in AS. The current study aims to provide a quantitative summary of wearable sensors used in AS, including contexts of use and psychometric properties, and to present key narrative highlights. METHOD: Literature searches were performed in three electronic databases: APA PsycInfo, PubMed and Web of Science Core Collection. Data items were categorized into four categories: sample characteristics, study methodological details, wearable sensor characteristics and psychometric properties assessed. Sample characteristics included sample size, age, biological sex, race/ethnicity and cognitive/developmental functioning. Study methodological details were subdivided into study design and setting. Wearable sensor characteristics included sensor type, placement site, means of attachment, assessed construct and sensor-related data loss. Psychometric properties assessed included reliability and validity of sensor-derived data. RESULTS: We identified 16 articles through our systematic review. Wearable sensors were used to study sleep (n&#x2009;=&#x2009;10, 62.5%), language (n&#x2009;=&#x2009;2, 12.5%), gait (n&#x2009;=&#x2009;2, 12.5%), caregiver proximity (n&#x2009;=&#x2009;1, 6.3%), EEG power (n = 1, 6.3%),&#xa0;and arousal (n&#x2009;=&#x2009;1, 6.3%) in AS through actigraphs, vocalization recorders, inertial sensors, radio-frequency identification watches, wireless EEG caps,&#xa0;and functional near-infrared spectroscopy caps, respectively. Findings from these studies broadly indicate that wearable sensors are feasible, reliable and valid for assessing a range of behaviours relevant to AS. CONCLUSIONS: Wearable sensors are a promising solution to enhance assessments in AS. However, with the small extant literature characterized by small sample sizes and restricted focus on a few relevant features in AS, there remains ample opportunities to explore the use of wearable sensors in people with AS. Additional studies will better inform clinical decision-making and ultimately improve the lives of people with AS and their families.

Humans

Effects of free-weight resistance training based on hexagonal barbell deadlift in older women: A 24-week randomized controlled trial.

PURPOSE: This randomized controlled trial examined effects of a 24-week hexagonal barbell deadlift (HBDL)-based free-weight resistance training program on body composition, trunk muscle function, and functional performance in older women. METHODS: Thirty-two women (67.6&#xa0;&#xb1;&#xa0;6.3&#xa0;years) were randomly assigned to an HBDL group (DG, n&#xa0;=&#xa0;16) or control group (CG, n&#xa0;=&#xa0;16). DG trained twice weekly for 24&#xa0;weeks under supervision. Primary outcomes were body composition and isokinetic trunk peak torque and average power at 60&#xb0;/s and 120&#xb0;/s. Secondary outcomes were isokinetic knee function, mobility, and maximal isotonic strength. Between-group differences after the intervention were examined by analysis of covariance (&#x3b1;&#xa0;=&#xa0;0.05). RESULTS: After intervention, DG showed greater trunk lean mass (+0.4&#xa0;kg vs. -0.2&#xa0;kg, p&#xa0;=&#xa0;0.006) than CG, and reductions in body fat percentage (-1.4% vs. +0.3%, p&#xa0;=&#xa0;0.003), total fat mass (-1.1&#xa0;kg vs. +0.3&#xa0;kg, p&#xa0;=&#xa0;0.013), and regional fat mass (trunk, gluteal, thigh; all p&#xa0;<&#xa0;0.05). Trunk extensor peak torque at 60&#xb0;/s (+26.0% vs. -6.3%, p&#xa0;<&#xa0;0.001) and average power at 60&#xb0;/s (+38.1% vs. -7.6%, p&#xa0;<&#xa0;0.001) and 120&#xb0;/s (+33.2% vs. +0.1%, p&#xa0;=&#xa0;0.002) improved significantly. DG also showed better eyes-closed static balance and 6-min walk performance (both p&#xa0;<&#xa0;0.05). Whole-body lean mass and lower-limb isokinetic strength did not differ between groups. Attendance was 89.6% with no adverse events. CONCLUSION: HBDL-based free-weight resistance training is a safe, feasible, and effective strategy to improve body composition, trunk extensor function, and mobility in older women.

Humans

Health Literacy and Capecitabine Adherence in a Remote Monitoring Pilot Trial for Breast Cancer: Post Hoc Exploratory Analysis.

BACKGROUND: Oral anticancer therapy enables convenient, home-based cancer care but can introduce adherence challenges, particularly with complex dosing schedules. Capecitabine is commonly used in breast cancer, often as adjuvant therapy or in advanced disease, and typically requires twice-daily dosing on cyclical schedules, increasing the risk of missed or incorrect doses. Low health literacy may exacerbate these difficulties, and emerging remote monitoring tools may help close this gap. OBJECTIVE: In this post hoc exploratory analysis, we evaluated whether health literacy (1) was associated with capecitabine adherence and (2) modified a remote monitoring intervention's effectiveness. METHODS: We conducted post hoc analyses of a 2-arm pilot trial that randomized women with breast cancer treated with capecitabine to enhanced usual care (EUC) or remote patient monitoring (RPM). Adherence was captured with a smart pill bottle, Nomi by SMRxT, that recorded dose timing and quantity. Participants in the RPM group received messages for missed or incorrect doses and weekly symptom assessments. Incorrect or missed doses and severe symptoms triggered alerts to the oncologist. Health literacy was assessed at enrollment. To evaluate moderation, we used linear regression with an interaction term (health literacy &#xd7; intervention arm) predicting adherence (proportion of days). Marginal effects quantified differences in adherence by study arm and health literacy. RESULTS: Among 28 participants (EUC, n=15 and RPM, n=13), 9 (32.1%) had lower health literacy, 16 (57.1%) identified as Black, 10 (35.7%) identified as White, and 15 (53.6%) had income below 200% of the federal poverty level. In the regression model, the health literacy &#xd7; randomized group interaction did not reach statistical significance (-16.3 percentage points, 95% CI -35.5 to 2.9; P=.09). Predicted adherence among lower health literacy participants was 87.5% in the RPM group and 65.5% in the EUC group (difference: +22.1 percentage points, 95% CI 6.2-37.9; P=.008). Among participants with higher health literacy, adherence was 89.9% in the RPM group and 84.1% in the EUC group (difference: +5.7 percentage points, 95% CI -5.2 to 16.7; P=.29). Within the EUC group, predicted adherence was 18.6 percentage points lower among those with lower versus higher health literacy (95% CI -32.4 to -4.9; P=.01); within the RPM group, this difference was 2.3 percentage points lower among those with lower versus higher health literacy (95% CI -15.8 to 11.1; P=.73). CONCLUSIONS: In this post hoc exploratory analysis, the estimated difference in capecitabine adherence between the RPM and EUC groups was larger among participants with lower health literacy. Although the formal interaction test was not statistically significant, the magnitude and direction of the observed difference support further investigation of RPM as a potential approach to improve adherence among patients facing health literacy-related adherence barriers. Larger, prospectively powered studies are needed to confirm these findings and evaluate downstream clinical outcomes.

Humans

An impact assessment of the European medical device regulations implementation - the current status quo.

BACKGROUND: This research aims to assess the current impact of the medical and in-vitro diagnostic devices regulations (MDR/IVDR) on the device industry in the EU, under the lens of postimplementation and the amending regulation, and in advance of the final transition to the IVDR/MDR in the future. RESEARCH DESIGN AND METHODS: A quantitative survey was administered to a diverse cohort of medical device enterprises, ranging from micro to large organizations. RESULTS: The survey indicates that the MDR/IVDR has harmed innovation, leading many manufacturers to seek initial device approval and launch elsewhere before in Europe. There is evidence that some manufacturers have rationalized their existing product portfolios and removed devices from the market as they stated they would in previous industry surveys. The MDR/IVDR has been shown to negatively impact manufacturers, with increased costs related to notified body (NB) fees, maintaining and updating documentation, recertification fees, and hiring additional staff. CONCLUSION: This study provides a current status of the effects of MDR/IVDR on manufacturers and finds that despite amending regulations and other interventions taken by the EU to mitigate regulatory burden, ensure product availability, and address stakeholder concerns, the EU is no longer the market of choice for new products.

Equipment and Supplies

Review of regulatory requirements for benefit-risk assessment for medical devices: uncovering existing methodologies.

INTRODUCTION: A positive benefit-risk profile is a prerequisite for the market approval of medical devices. However, regulations are often criticized for providing limited information on benefit-risk assessment (BRA) despite growing expectations for quantitative methods. A clearer understanding of regulatory requirements, existing methodologies, and unresolved issues is needed. AREAS COVERED: Relevant regulatory documents referencing BRA for medical devices were systematically identified, with a primary focus on the European regulation followed by screening to extract BRA&#x2011;related requirements and any explicitly or implicitly described methods. The findings were analyzed and consolidated by BRA context, type, objective, methodological description, and implementation, thereby establishing a basis for the BRA methodological landscape. EXPERT OPINION: BRA is not a single concept, but a set of context&#x2011;dependent assessments across lifecycle of a medical device. BRA within clinical evaluation framed into BRAs of risk management holds a pivotal role and is supported by the most detailed methodological guidance, although BRAs in other contexts are important. A structured overview of existing BRA requirements clarifies their treatment across regulatory documents. By differentiating BRA contexts, types, objectives, and required methodological detail, the analysis supports a more transparent understanding of BRA and helps identify priorities for methodological refinement and interface clarification.

Risk Assessment

Insights from expert panels on the EU clinical evaluation consultation procedure.

BACKGROUND: The Clinical Evaluation Consultation Procedure (CECP) under the EU Medical Device Regulation aims to strengthen and harmonize the assessment of high-risk medical devices. This review summarizes early insights from expert panels to support improved clinical evaluation practices. RESEARCH DESIGN AND METHODS: This review analyses 34 expert panel opinions derived from 281 CECP submissions between April 2021 and December 2025. Statements from opinions were systematically extracted, de-duplicated, and grouped into thematic categories, with independent review and validation. The analysis focuses on common challenges found during the consultation procedure of the expert panels on the content of the clinical assessment in relation to clinical evidence, benefit-risk assessment, intended purpose alignment, and post-market clinical follow-up planning. RESULTS: Expert panel findings highlight recurrent issues in the sufficiency, consistency, and transparency of clinical evidence, underscoring the need for improved standardization and clearer guidance. CONCLUSIONS: Strengthening documentation quality and alignment across stakeholders will enhance the robustness, efficiency, and predictability of conformity assessments for high-risk medical devices.

Humans

Percutaneous left ventricular assist device in cardiogenic shock associated with and without acute myocardial infarction: a real-world retrospective cohort study.

BACKGROUND: Percutaneous left ventricular assist devices (pLVAD, such as Impella), are increasingly used for cardiogenic shock (CS). Outcomes may differ between acute myocardial infarction-related CS (AMI-CS) and non-AMI CS due to differing pathophysiology and trajectories. METHODS: Using the USA TriNetX Network (2016-2024), we identified adults with CS treated withpLVAD. AMI-CS was defined by MI within seven days of implantation; non-AMI CS included all patients with CS not attributable to acute MI, representing heterogeneous etiologies such as decompensated cardiomyopathy, myocarditis, valvular failure, pulmonary vascular causes, and arrhythmic shock. Patients with recent coronary artery bypass graft (CABG) were excluded. Propensity matching produced two balanced cohorts (n&#x2009;=&#x2009;2,026 each). RESULTS: Among 6,873 AMI-CS and 4,521 non-AMI CS patients, matched groups were similar (mean age 63&#x2009;years, 26% female). AMI-CS had higher mortality at 30&#x2009;days (hazard ratio [HR] 1.19, p&#x2009;=&#x2009;0.002), 90&#x2009;days (HR 1.13, p&#x2009;=&#x2009;0.02), and 180&#x2009;days (HR 1.14, p&#x2009;=&#x2009;0.007). Heart failure (HF) exacerbations (HR 1.21, p&#x2009;<&#x2009;0.001) and pulmonary edema (HR 1.23, p&#x2009;=&#x2009;0.005) were also more common in AMI-CS. Stroke, ventricular arrhythmias, cardiac arrest, acute kidney injury, major bleeding, vascular complications, and hemodialysis were comparable. CONCLUSION: AMI-CS patients supported with pLVAD experienced higher mortality and greater HF-related morbidity than non-AMI CS.

Humans

Morphology-Encoded Colorimetric Hydrogen Sensing Using Embedded Reactive Pd Absorbers in Fabry-Perot Cavities.

Chemical reactions offer a powerful strategy for generating visible optical responses through localized changes in absorption, dielectric environment, and interfacial wetting. A palladium (Pd)-embedded Fabry-Perot cavity is introduced as a reaction-active optical platform in which structural color is governed by intracavity absorption coupled with reaction-induced dielectric perturbation. Positioning Pd within the dielectric spacer creates a spatially controllable reactive absorber whose vertical location relative to the standing-wave field dictates wavelength-selective absorption within the cavity. The morphology of the embedded Pd layer provides an additional design parameter by modulating both optical loss and interfacial wetting. Under hydrogen exposure in the presence of oxygen, catalytic water formation at the Pd/polymer interface generates localized dielectric heterogeneity and interfacial water droplets, thereby perturbing the optical path length and amplifying the visible response. As a result, the cavity exhibits pronounced, morphology-dependent color transitions that are inaccessible through dielectric-layer engineering or Pd/PdH refractive-index changes alone, enabling direct visual hydrogen sensing under ambient light, as well as flexible optical devices capable of large-area patterning. These findings establish a design framework for reaction-active optical cavities that translate localized chemistry into a colorimetric hydrogen sensing mechanism.

Fabry&#x2013;Perot resonator

Effect of Music on Pain, Anxiety, and Satisfaction During Intrauterine Device Application: A Randomized Clinical Trial.

This randomized controlled trial aimed to determine the effect of music played during intrauterine device (IUD) insertion on perceived pain, state anxiety, and satisfaction levels. The study was conducted with 70 women who applied to a maternal and child health and family planning center and were randomly assigned to the intervention and control groups using simple randomization. Data were collected using a Demographic Information Form, the State-Trait Anxiety Inventory (STAI-I), and the Visual Analog Scale (VAS), as well as Bluetooth speakers and the musical piece Evgeny Grinko-Valse. Participants in the intervention group listened to music before and during the IUD insertion procedure, whereas the control group received routine care only. Data were analyzed using SPSS version 26 with appropriate descriptive and inferential statistical methods. Women in the music group had significantly lower perceived pain (p&#x2009;<&#x2009;0.001) and state anxiety levels during the procedure (p&#x2009;=&#x2009;0.022), and significantly higher satisfaction levels compared with the control group (p&#x2009;<&#x2009;0.001). In addition, post-procedure state anxiety levels were positively correlated with pain intensity experienced during and after the procedure (r&#x2009;=&#x2009;0.542 and r&#x2009;=&#x2009;0.496, respectively; p&#x2009;<&#x2009;0.001), and negatively correlated with procedural satisfaction (r&#x2009;=&#x2009;-0.652; p&#x2009;<&#x2009;0.001). These findings suggest that listening to music during IUD insertion may help reduce pain and anxiety while potentially enhancing patient satisfaction. Trial Registration: NCT06215183.

Humans

Clinical Trial: Effectiveness and Safety of a Novel Anal Insert Device for Treatment of Faecal Incontinence.

BACKGROUND: Treatment options for medically-refractory faecal incontinence (FI)-including anorectal biofeedback, dextranomer injection, and sacral nerve stimulation-are limited and outcomes are often suboptimal. Anal or vaginal insert devices are infrequently used. AIMS: We evaluated the safety and effectiveness of a new anal insert device (StaySure) in patients with FI. METHODS: Patients with FI for&#x2009;&#x2265;&#x2009;6&#x2009;months and&#x2009;&#x2265;&#x2009;4 moderate or large FI episodes during a 4-week baseline entered a 2-4&#x2009;week fitting/run-in period to individualise device size (10 or 13&#x2009;mm) followed by a 4-week treatment period. Outcomes included effectiveness, safety, and quality of life (QoL). The primary outcome was the proportion achieving a&#x2009;&#x2265;&#x2009;50% reduction in FI frequency. RESULTS: Of 124 enrolled patients, 98, 71, and 61 progressed through the baseline, fitting/run-in, and treatment phases respectively, with few exclusions due to device intolerance. In the intent-to-treat cohort of 59 participants (93% women), mean (SD) number of days with FI declined from 13.2 (7.0) to 6.3 (6.9), and FI weekly episodes declined from 5.4 (6.9) to 2.1 (5.1) (69% reduction; p&#x2009;<&#x2009;0.001) with similar results for both device sizes. The primary endpoint was achieved in 76.3% of participants; 54.2% achieved&#x2009;&#x2265;&#x2009;75% reduction. The FIQoL overall score increased from a mean (SD) of 1.9 (0.6) to 2.3 (0.6) (p&#x2009;<&#x2009;0.001), indicating improved QoL. Improvements in FI frequency, FIQoL exceeded minimal clinically important difference thresholds, confirming clear clinical benefit. No treatment-related serious adverse events were reported. CONCLUSIONS: The StaySure anal insert device is safe, well tolerated, and effective in reducing FI in patients with moderate to severe symptoms refractory to conservative therapies. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT03898778.

Adult