Search PubMedSearch

SEARCH · Search PubMed

Results for “orbital implant”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

46 recordsLinked to original sources

Socket motility assessment of anophthalmic sockets: a systematic review.

PURPOSE: Systematically review and categorize the methods used to assess socket and prosthetic motility in anophthalmic patients following enucleation or evisceration. METHODS: A systematic review was conducted in accordance with PRISMA guidelines. PubMed, Embase, Web of Science, and Scopus were searched from inception through September 2024. Studies reporting qualitative or quantitative assessments of motility in anophthalmic sockets or ocular prostheses were included. Motility assessment methods were categorized as qualitative (descriptive or graded clinical evaluation) or quantitative (numerical measurements in millimeters, degrees, or objective tracking systems). RESULTS: Thirty-five studies encompassing 1,819 patients met inclusion criteria. Nineteen studies used qualitative assessment methods, including subjective observation, graded scales based on cardinal gaze positions, or comparison with the contralateral eye. Sixteen studies employed quantitative techniques, such as the Kestenbaum limbus test, Lister perimeter measurements, conjunctival or limbal markings, photographic image analysis, infrared eye-tracking systems, and magnetic search-coil technology. Considerable heterogeneity was observed in measurement techniques, reporting standards, timing of assessment, and distinction between socket and prosthetic motility. CONCLUSIONS: Substantial variability exists in the methods used to assess motility in anophthalmic sockets, limiting comparability across studies. Establishing standardized, feasible, and reproducible assessment approaches may improve outcome reporting and facilitate meaningful comparisons in future oculoplastic research.

Humans

Orbital involvement in sickle cell disease: A systematic review.

Orbital involvement in sickle cell disease (SCD) is rare but potentially vision-threatening and is often misdiagnosed due to overlap with infectious orbital disease. We conducted a systematic review of case reports and series describing orbital complications in patients with confirmed SCD, following PRISMA and MOOSE guidelines. Across 53 studies, 76 cases were identified. Patients were predominantly male (77.6%), with an average age of 13.2 years. Orbital disease was the initial SCD manifestation in 6.6%. Presentations included periorbital edema in all, proptosis in 64.1%, restricted ocular motility in 56.5%, reduced visual acuity in 28.1%, and bilateral involvement in 38.2%. Laboratory findings commonly included leukocytosis (73%) and raised inflammatory markers (86.7%). Radiologically, orbital subperiosteal hematoma were observed in 70%, combined orbital bone infarction and hematoma in 38.2%, and orbital bone infarction alone in 19.7%. Magnetic resonance imaging is critical for accurate diagnosis. Intracranial hemorrhage was present in 9.2%. Less frequent manifestations included orbital apex syndrome, lacrimal gland disease, and nonspecific soft tissue swelling. Management was primarily conservative (82.9%), and surgery was reserved for vision-threatening or intracranial complications. Complete recovery was achieved in 93.1% of cases. While severe vision-threatening complications are uncommon, early recognition remains critical to optimising outcomes in sickle cell orbitopathy.

Humans

ORBIT: Oncogenic Representation Learning via Bi-Prototype Contrastive Learning in Hyperbolic Space for cancer driver gene identification.

Accurate identification of cancer driver genes is crucial for precision oncology but remains challenging due to the complexity of integrating heterogeneous data and modeling dynamic biological systems. To address these limitations, we propose ORBIT (Oncogenic Representation Learning via Bi-Prototype Contrastive Learning in Hyperbolic Space). Our framework synergistically fuses multi-omics profiles with functional network data using a context-adaptive graph reweighting mechanism to capture cancer-specific dynamics. The model employs a bi-prototype contrastive learning strategy within hyperbolic space, which aligns gene representations around distinct driver and non-driver semantic anchors while preserving the intrinsic hierarchy of biological networks. Comprehensive evaluations demonstrate that ORBIT achieves highly competitive stability in pan-cancer analysis while consistently outperforming state-of-the-art methods in cancer-specific predictions. Furthermore, functional enrichment analysis confirms that the model effectively segregates core cancer pathways, and drug sensitivity profiling validates the clinical relevance of the identified drivers. By integrating hyperbolic geometry with context-adaptive learning, ORBIT offers a robust and interpretable paradigm for precision medicine. The source codes and datasets are publicly accessible at https://github.com/spcho-dev/ORBIT.

Humans

Indications, Techniques and Complications Associated With Pterygoid Implants: A Systematic Review and Meta-Analysis.

BACKGROUND AND OBJECTIVES: Pterygoid implants represent a graftless option for rehabilitation of patients with posterior maxillary atrophy, engaging the dense cortical bone of the pterygomaxillary complex. Despite clinical growth, a comprehensive synthesis of indications, surgical techniques, and complications is lacking. This review evaluated the prevalence of complications, implant survival rates, and marginal bone loss (MBL) associated with pterygoid implant placement. METHODS: The reporting of this review follows PRISMA 2020 guidelines. Six electronic databases (PubMed, Ovid, Scopus, WoS, CENTRAL, and Dentistry & Oral Sciences Source) were searched from 1 January 2020 to 31 December 2025. Included criteria comprised randomized and non-randomized clinical studies reporting outcomes of pterygoid implants (≥ 13 mm) in adult patients with posterior maxillary atrophy (minimum 10 implants). Risk of bias was assessed using JBI critical appraisal checklists. Proportions were pooled using the Freeman-Tukey double arcsine transformation under a random-effects model. Certainty of evidence was assessed using GRADE. RESULTS: Seventeen studies reporting 846 patients and 1915 pterygoid implants were included. The pooled survival rate was 97.9% (95% CI: 97.1%-98.6%; I2 = 0%; 14 studies) and the overall failure rate was 2.1% (95% CI: 1.4%-3.0%). Early failure rate was 0.9% (95% CI: 0.0%-3.0%; I2 = 59.5%). Late failure and MBL were summarized narratively. Certainty of evidence was low to very low. CONCLUSIONS: Pterygoid implants demonstrate excellent survival (97.9%) and low failure rates (2.1%), primarily early, supporting their reliability as a graftless solution for posterior maxillary atrophy. Complications appear infrequent though heterogeneously reported. Low evidence certainty necessitates prospective studies with standardized outcome reporting.

Humans

Clinical accuracy and short-term outcomes of intraoral photogrammetry for complete-arch implant rehabilitation: A retrospective multicentre study on 35 patients.

OBJECTIVES: To evaluate the clinical accuracy and short-term outcomes of complete-arch implant-supported fixed dental prostheses (ISFDPs) fabricated using an intraoral photogrammetry (IPG) based digital workflow in completely edentulous patients. METHODS: This multicenter retrospective clinical study included 35 patients rehabilitated with 52 complete-arch ISFDPs (10 FP1, 18 FP2 and 24 FP3 restorations) supported by 221 implants. All definitive prostheses were designed and fabricated using a fully digital workflow initiated by IPG acquisition with the Aoralscan Elite IPG® (SHINING 3D). The primary outcome was clinical accuracy, assessed at definitive prosthesis delivery through evaluation of passive fit using the Sheffield test and radiographic verification. Secondary outcomes included biologic and prosthetic complications, as well as implant and prosthesis survival rates during the follow-up. RESULTS: Passive fit was achieved in all definitive restorations (100%). Radiographic evaluation confirmed accurate marginal adaptation at the implant-prosthesis interface in all cases. No statistically significant differences in clinical accuracy were observed according to treated arch, number of supporting implants, or prosthetic design (P > .05). During a mean follow-up period of 12.1 ± 3.5 months, biologic and prosthetic complications were limited and generally minor. Implant survival was 99.5%, and prosthesis survival was 100%. CONCLUSIONS: Within the limitations of this retrospective clinical study, the IPG based workflow demonstrated high clinical accuracy and predictable short-term outcomes for complete-arch implant rehabilitation, consistently enabling passive fit and favorable prosthetic performance. CLINICAL RELEVANCE: IPG may represent a clinically reliable and predictable approach for complete-arch digital implant impression acquisition. The high rates of passive fit, together with the low incidence of biologic and prosthetic complications observed in this multicenter clinical study, support the use of IPG based workflows for the fabrication of complete-arch ISFDPs.

Humans

The use of diode laser and scalpel blade in stage-two dental implant surgery: a comparative study.

OBJECTIVE: The use of lasers in dental implant procedures raises questions regarding the preservation of keratinized tissues and implant outcomes. This study aimed to compare the clinical effects (pain and impression time) and soft tissue healing (keratinization, peri-implant probing, bleeding, and healing) of diode lasers and scalpels used during stage-two dental implant surgery. METHOD AND MATERIALS: A prospective randomized clinical trial with a 1:1 allocation ratio was conducted. The study included 30 patients, each with a single, fully osseointegrated implant. Patients were categorized into two groups. The study group underwent stage-two implant surgery using a 970-nm diode laser. In the control group, implants were exposed using a conventional surgical blade. A comparison between the diode laser and conventional scalpel groups was made based on clinical outcomes (pain and impression time) and soft tissue healing (keratinization, peri-implant probing, bleeding, and healing). Data were analyzed using a paired t test. RESULTS: Pain intensity significantly decreased from immediate postoperative to 7 days in both scalpel (49.87 ± 6.78, t = 28.48, df = 14, P .001) and diode laser (7.67 ± 7.58, t = 3.91, df = 14, P = .002) groups. Immediately after surgery, pain scores were significantly higher in the scalpel group compared with the diode laser group (94.53 ± 4.45 vs 46.93 ± 5.85, t = 25.076, df = 26.151, P .001). Although pain decreased in both groups by day 7, the scalpel group continued to exhibit significantly greater pain (44.67 ± 5.96 vs 39.27 ± 3.73, t = 2.974, df = 23.513, P = .007). Impression time (P = .231) and gingival keratinized tissue (P = .736) did not differ significantly between the scalpel and diode laser approaches. At week 6, the scalpel group exhibited a significantly higher mean peri-implant bleeding index (2.60 ± 0.507) compared with the laser group (0.07 ± 0.258, P .001). However, after 12 weeks, no significant difference was observed (1.58 ± 0.19 vs 1.55 ± 0.21, P = .748). Laser surgery produced significantly better early wound healing at all intervals (P .001), while intraoperative bleeding was more common with the scalpel technique than with the diode laser (100.0% vs 66.7%, P = .042). CONCLUSION: Compared with the scalpel method, the diode laser method resulted in a significant reduction in pain intensity, improved wound healing, and less peri-implant bleeding during the stage-two dental implant surgery.

Humans

Comparison of short-term clinical outcomes and patient satisfaction between intraoral scanning and conventional impressions for complete-arch implant prostheses: a pilot RCT.

OBJECTIVE: To compare framework passive fit, subjective evaluations, and short-term clinical outcomes between conventional impressions (CI) and intraoral scanning (IOS) for complete-arch implant-supported fixed dental prostheses (CIFDPs). METHODS: In this randomized controlled trial, 22 patients were allocated to the CI or IOS groups. All participants received a definitive one-piece CIFDP. The primary outcome was framework passive fit, assessed using the Vision and Tactile Score (V&T score), which included framework lift-off, the single-screw test, the full-screw test, smoothness of screw insertion, and radiographic gap assessment. Secondary outcomes included operator evaluation, patient satisfaction using a visual analog scale (VAS), early implant survival, marginal bone loss (MBL), modified Plaque Index (mPII), and complications at the 6-month follow-up. RESULTS: Twenty-two patients were enrolled (CI: n = 11; IOS: n = 11), and one patient in the CI group was lost to follow-up. No statistically significant difference in the V&T score was observed between the CI and IOS groups (4.66 &#xb1; 0.17 vs. 4.65 &#xb1; 0.28; P = 0.93). The operator reported greater nervousness during the CI procedure than during IOS (21.82 &#xb1; 15.69 vs. 8.64 &#xb1; 7.47; P < 0.05). Patients in the CI group reported significantly greater discomfort, including nausea and anxiety, than those in the IOS group (P < 0.05). At the 6-month follow-up, the early implant survival rate was 100% in both groups. No significant differences were found between the groups in MBL (0.09 &#xb1; 0.09 vs. 0.06 &#xb1; 0.10 mm; P = 0.43) or mPII (0.10 &#xb1; 0.12 vs. 0.10 &#xb1; 0.28; P = 0.99). CONCLUSION: IOS and CI achieved comparable short-term clinical outcomes in patients who met the predefined inclusion criteria, including controlled implant number, spacing, and angulation. IOS provided a more favorable experience for both operators and patients. CLINICAL SIGNIFICANCE: In complete-arch implant restorations, intraoral scanning may provide clinical outcomes comparable to those of conventional impressions while improving patient comfort.

Humans

Evaluation of intravenous sedation in dental implant surgeries: A prospective cohort study.

PURPOSE: This study aimed to evaluate the impact of intravenous sedation on patient-centered outcomes during implant and bone augmentation surgeries. METHOD: A prospective observational cohort study included 40 patients undergoing placement of &#x2265;3 implants, with or without bone augmentation. Patients underwent surgery under either intravenous sedation (n = 20) or local anesthesia alone (n = 20), according to routine clinical decision-making and patient preference. The sedation group received intravenous sedation with a multimodal regimen comprising remimazolam, dexmedetomidine, alfentanil, and low-dose esketamine, whereas the control group received local anesthesia only. Patient-reported outcome measures, hemodynamic parameters (SBP, DBP, HR, SpO2), postoperative pain (0-10 scale), and OHRQoL (OHIP-14) were recorded from baseline through 7 days post-surgery. RESULTS: Intravenous sedation was associated with significantly lower intraoperative pain (0.5 [IQR: 0&#x223c;2.75] vs. 3.25 &#xb1; 2.40, p = 0.003), anxiety (1 [IQR: 0&#x223c;2.75] vs. 4 [IQR: 3&#x223c;6], p = 0.001), and experienced discomfort (2 [IQR: 1&#x223c;3.75] vs. 4.15 &#xb1; 2.16, p = 0.016), and shortened perceived treatment duration (2.90 &#xb1; 2.34 vs. 5 [IQR: 4&#x223c;5], p = 0.020). Early postoperative pain was lower in the sedation group from Days 1-4 (p = 0.003-0.010). Hemodynamic parameters were more stable under sedation, with lower SBP (116.42 &#xb1; 13.32 vs. 144.11 &#xb1; 17.42 mmHg, p < 0.001), DBP (73.21 &#xb1; 10.28 vs. 82.37 &#xb1; 11.03 mmHg, p = 0.012), and HR (71.00 [IQR: 62.50&#x223c;79.25] vs. 85.00 &#xb1; 10.72 bpm, p = 0.021). OHRQoL scores favored the sedation group in swallowing, diet, malaise, and daily activities, particularly during the first three postoperative days (p=0.006-0.040). CONCLUSION: Intravenous sedation may enhance the patient experience during implant and/or bone augmentation procedures by reducing intraoperative pain and anxiety, improving hemodynamic stability, and promoting better early-postoperative recovery and OHRQoL. These findings suggest that intravenous sedation provides a safe and effective alternative for implant dentistry surgery, particularly for anxious or pain-sensitive individuals.

Humans

Influence of nicotine on protein expression around hydrophilic osseointegrated implants: A proteomic study in male rats.

OBJECTIVE: To ensure the success of dental implant treatment, various factors must be considered, including osseointegration and systemic conditions. There is evidence in the literature that smokers may exhibit alterations in tissue healing, which can compromise the success of implant rehabilitation. Therefore, this study aimed to investigate the influence of nicotine on the protein profile of bone tissue around hydrophilic implants during the osseointegration process in rats. DESIGN: Bone tissue samples from the control and nicotine groups (n&#x202f;=&#x202f;3 per group) were subjected to protein extraction, mass spectrometry, and bioinformatic analyses. Protein identification was performed using Proteome Discoverer 2.1 software and the SEQUEST algorithm, and the protein data were compared with those of a protein database of Rattus norvegicus obtained from UniProt. RESULTS: A total of 740 proteins were detected in both the control group and the nicotine-exposed group. Among them, the proteins biglycan, periostin and histone H4 were highlighted because of their higher abundance in the healthy implant group, while they were reduced in the nicotine-exposed group. CONCLUSIONS: Nicotine has the potential to alter the protein profile of bone tissue around hydrophilic implants during osseointegration, which may impair tissue remodeling and healing.

Animals

Assessment of Surgical Salvage Outcomes for Exposed Cranial Neuromodulating Devices.

OBJECTIVES: Implanted neuromodulating devices (NMDs) such as cochlear implants (CIs) and deep brain stimulators (DBSs) are commonly used in modern medicine. Rarely, complications arise post-operatively, including hardware exposure. Traditional teaching suggests that these devices require removal if exposed; however, surgical salvage is a high risk, high reward alternative. We review our single institution experience managing NMD exposure with surgical salvage. METHODS: Retrospective chart review was performed on individuals who had a NMD implanted and underwent an attempt at surgical salvage for exposure during the study period (January 01, 2021 through December 31, 2023). Study outcome success was defined as maintaining a functional NMD 1&#x2009;year after salvage was attempted. Surgical techniques associated with successful salvage were compared. RESULTS: Nine of 729 patients (1.2%) implanted with NMDs experienced hardware exposure during this 2-year study period. Nine subjects were referred for NMD salvage; however, only 6 of 9 subjects (66.7%, CI&#x2009;=&#x2009;3; DBS&#x2009;=&#x2009;3) underwent NMD salvage attempts. Four of the subjects had successful salvage demonstrated successful salvage with a functioning NMD and without wound healing concerns 1&#x2009;year after their salvage procedure. CONCLUSIONS: Classic teaching states that exposed NMDs require explantation. However, this approach necessarily imposes time without benefit from the NMD between explantation and reimplantation. Our experience demonstrates that surgical salvage can be a successful alternative for the majority (66.7%) of individuals.

Humans

Proteomic insights into the immunomodulatory effects of Ca/Sr co-doped sol-gel coatings for titanium implants.

Ionic functionalization of biomaterial coatings has emerged as a powerful strategy to regulate early host responses at the implant interface. However, how combined Ca/Sr incorporation governs the adsorbed proteome and downstream immune signaling remains poorly understood. This study analyses, employing in vitro tests and proteomics, the effect of adding Sr and Ca to Si-based coatings designed to bioactivate Ti implants. Hybrid Si-based coatings were synthesized by the sol-gel route with a fixed Ca content (0.5&#x202f;wt%) and increasing Sr contents (0.5, 1.0, 1.5&#x202f;wt%), and their physicochemical properties, ion release kinetics, and hydrolytic stability were characterized. The coatings remained highly crosslinked despite Ca/Sr incorporation, whereas the highest Sr content increased hydrolytic degradation to around 70% after 56 days. Proteomic analysis identified 183 adsorbed proteins, of which 56 were differentially adsorbed on Ca/Sr-coatings, mainly associated with immune and coagulation pathways. In vitro, RAW 264.7 showed increased gene expression of TNF-&#x3b1; and TGF-&#x3b2;; with an enhanced TNF-&#x3b1; secretion by the addition of Ca and Sr. In parallel, MC3T3-E1 indicated that Ca/Sr-coatings were not cytotoxic and did not impair cell proliferation. However, ALP activity was reduced in the co-doped groups, indicating that the immunomodulatory effects induced by Ca/Sr incorporation were not accompanied by enhanced early osteogenic differentiation. The Ca/Sr combination induced alterations in the adsorption of immune-related proteins, which correlated with the in vitro findings. The deeper insight into how Ca/Sr mixtures modulate protein adsorption on biomaterial surfaces may be key to understanding the immunomodulatory capacity of these bioactive cations.

Animals

Cochlear Implantation in Sickle Cell Disease: A Systematic Review of Feasibility and Outcomes.

INTRODUCTION: Sickle cell disease (SCD) is associated with systemic complications, including sensorineural hearing loss (SNHL) from microvascular occlusion and chronic inflammation. Although reports link SCD to higher rates of SNHL, current evidence is limited by small sample size, varied audiologic methods, and lack of standardized screening. This systematic review summarizes available literature on SNHL and cochlear implantation (CI) in SCD. METHODS: A literature search of PubMed MEDLINE, Embase, Scopus, Web of Science, and CINAHL identified 79 citations. After removal of duplicates, 35 records were screened in Rayyan. Studies published between January 1, 2000, and June 30, 2025, were eligible if they reported patients with SCD who developed hearing loss and underwent CI. Nine full texts were reviewed, and 4 met the inclusion criteria. Screening and review were performed independently by 2 authors per PRISMA guidelines. RESULTS: Across 4 case reports, a total of 5 patients with SCD underwent CI, ranging in age from 2 to 42 years. Four presented with bilateral severe-to-profound SNHL and one with unilateral loss. Implantation was technically feasible in all cases, including patients with cochlear fibrosis or ossification requiring modified insertion techniques. Postoperative outcomes were favorable: all patients demonstrated reliable device function and low impedances. Only 60% showed meaningful auditory benefit, characterized by improved functional speech perception in 2 patients (40%) and access to the speech frequency range with hearing testing going from moderate/profound hearing loss to mild hearing loss in 3 patients (60%). Complications occurred in 2 patients (40%): one developed unilateral middle ear infection leading to meningitis, and another experienced a postoperative pulmonary embolism requiring anticoagulation. The remaining 3 patients (60%) had uncomplicated recoveries with reported improved hearing from moderate/profound hearing loss to mild hearing loss post implantation. CONCLUSION: While CI appears feasible in SCD, our findings suggest that additional data are needed to assess its effectiveness in this patient population. However, evidence is limited to case reports, and complications such as thromboembolism and rapid cochlear fibrosis highlight the need for close perioperative management. More comprehensive studies with larger sample size are required to define surgical risk, optimize management, and establish best practices for timely implantation in this population.

Humans

Fused Deposition Modeling (FDM) of polyether-ether-ketone (PEEK) dental implants: A systematic review of the effect of printing parameters on mechanical behaviour and surface quality.

PURPOSE: This systematic review evaluated how FDM printing parameters influence mechanical behaviour and surface characteristics of 3D-printed PEEK and identified parameter combinations linked to the most favourable mechanical performance and surface quality. MATERIALS AND METHODS: An electronic search was conducted in: MEDLINE (Ovid), PubMed, Embase, Web of Science, Scopus, and Compendex (last update: January 2025). Studies that evaluated the effect of FDM printing parameters on mechanical and surface properties of PEEK were included. Outcomes comprised compressive, tensile, and flexural strengths, elastic modulus, fracture toughness, surface hardness, roughness, and wettability. RESULTS: Of 4005 reports screened, 54 manuscripts were included. 92.6% (n&#x202f;=&#x202f;50) of articles showed low risk-of-bias, while 7.4% (n&#x202f;=&#x202f;4) showed medium risk-of-bias. Tensile strength was the most investigated mechanical parameter (78%), followed by elastic modulus (41%), flexural strength (30%), compressive strength (20%), and fracture toughness (6%). Surface roughness was the most evaluated surface property (30%), followed by hardness (17%) and wettability (6%). Across studies, higher printing temperatures, lower printing speed, thinner layer thickness, and maximum infill ratio in a horizontal printing orientation were associated with higher strengths, less warpage, increased accuracy, and improved surface quality. CONCLUSION: Specific combinations of FDM printing parameters can significantly improve the mechanical and surface properties of PEEK. However, it is difficult to meet all the optimal conditions simultaneously. Thus, balancing between different parameters must be considered in practical production.

Benzophenones

Soft Tissue Volume Augmentation at Single Implant Sites Applying Collagen Matrices or Connective Tissue Grafts: 10-Year Follow-Up of a Randomized Controlled Trial.

AIM: To compare up to 10&#x2009;years clinical, profilometric and patient-reported outcomes of implant sites previously augmented using a volume-stable collagen matrix (VCMX) or connective tissue graft (SCTG) in the aesthetic zone. METHODS: The original non-inferiority randomized controlled trial (RCT) enrolled 20 patients who received soft tissue volume augmentation with VCMX or SCTG at single implant sites. Clinical assessments and standardized measurements were performed at baseline after crown insertion and at 6&#x2009;months, 1, 3, 5, 7.5, and 10&#x2009;years. The primary outcome was mucosal thickness. Secondary outcomes included marginal bone levels (MBL), probing depth (PD), bleeding on probing (BOP), plaque control record, Pink Aesthetic Score (PES), OHIP-14 and buccal profilometric changes. Group comparisons were performed using mixed-effects and generalized estimating equation (GEE) models, which account for within-patient correlations due to repeated measurements and allow inclusion of all available data without requiring imputation for missing observations. RESULTS: Of the 20 originally enrolled patients, 10 (5 in the SCTG group and 5 in the VCMX group) were available for re-examination at 10&#x2009;years. The adjusted between-group difference in mucosal thickness was -0.02&#x2009;mm (95% CI -0.99 to 0.96). As the lower bound of the confidence interval remained above the prespecified non-inferiority margin of -1&#x2009;mm, non-inferiority of VCMX was shown. Buccal contour changes were comparable during the early follow-up, while a trend toward a greater long-term contour decrease was observed in group VCMX (-0.31&#x2009;mm [95% CI, -0.65 to 0.03]; p&#x2009;=&#x2009;0.07). Mean PES values were 10.6 in the SCTG group and 9.6 in the VCMX group, with no significant between-group differences (p&#x2009;=&#x2009;0.45). Both groups revealed high levels of oral health-related quality of life, with low median OHIP-14 scores (SCTG, 0.0; VCMX, 1.0; p&#x2009;=&#x2009;0.26). CONCLUSION: These preliminary long-term findings showed no clinically relevant differences between SCTG and VCMX in terms of clinical, profilometric and patient-reported outcomes. While SCTG remains the reference standard, VCMX represents a less invasive alternative but with a slight tendency toward greater long-term contour reduction. CLINICAL SIGNIFICANCE: Volume-stable collagen matrices serve as a viable alternative to autogenous connective tissue grafts for peri-implant soft tissue volume augmentation, particularly in patients seeking a reduced morbidity, without compromising long-term clinical or aesthetic outcomes. TRIAL REGISTRATION: German Clinical Trials Register: DRKS00017484.

Humans

Influence of Concave Versus Convex Emergence Profiles on Midfacial Mucosal Stability-A Systematic Review With Meta-Analysis.

OBJECTIVES: To systematically evaluate the influence of concave versus convex emergence profiles on midfacial mucosal stability in partially edentulous patients restored with implant-supported single restorations. MATERIALS AND METHODS: A systematic review and meta-analysis of randomized controlled trials (RCTs) was conducted and registered in PROSPERO (CRD420251139042). An electronic search in MEDLINE (PubMed) and Embase was performed up to May 7, 2026. Eligible studies included RCTs comparing concave (test group) and convex (control group) transmucosal prosthetic designs and reporting midfacial mucosal level changes (mm). Data extraction and risk of bias assessment (RoB 2) were performed independently. A random-effects meta-analysis was conducted using weighted mean differences (MDs) and 95% confidence intervals (CIs). Heterogeneity was assessed using the I2 statistic and sensitivity analyses were performed to evaluate the robustness of the findings. RESULTS: Four RCTs including 144 implants with a 12-month follow-up were included. Of these, 128 implants contributed to the quantitative synthesis, with 66 implants allocated to the concave/modified emergence profile group and 62 implants allocated to the convex/non-concave emergence profile group. The pooled analysis demonstrated a mean difference of -0.31&#x2009;mm (95% CI -0.63 to 0.02; p&#x2009;=&#x2009;0.064), indicating a trend toward greater midfacial mucosal recession with convex emergence profiles compared with concave designs. Between-study heterogeneity was low to moderate (I2&#x2009;=&#x2009;28%), suggesting consistent findings across studies. Sensitivity analyses confirmed the direction of the effect, with pooled estimates ranging from -0.12 to -0.43&#x2009;mm. Exclusion of one study resulted in a statistically significant difference favoring concave emergence profiles (-0.43&#x2009;mm; 95% CI -0.70 to -0.16; p&#x2009;=&#x2009;0.002). CONCLUSIONS: Convex emergence profiles are associated with a tendency toward increased midfacial mucosal recession. Concave profiles are preferable to support peri-implant soft-tissue stability. CLINICAL RELEVANCE: Emergence profile design should be considered an integral component of prosthetic and surgical planning. The use of concave transmucosal contours during provisionalization and definitive restoration may contribute to improved peri-implant soft tissue stability and enhanced esthetic outcomes.

Humans

Intravenous Tranexamic Acid Reduces Perioperative Blood Loss in Reduction Mammoplasty With Immediate Implant-Based Reconstruction: A Randomized, Triple-Blinded, Placebo-Controlled Trial.

BACKGROUND: Postoperative hematoma and oozing can compromise outcomes after reduction mammoplasty with immediate reconstruction. Intravenous (IV) tranexamic acid (TXA) is antifibrinolytic, but prospective evidence in this setting is limited. OBJECTIVES: The aim of this study was to determine whether a single pre-incision dose of IV TXA reduces perioperative blood loss and fibrinolytic activation vs placebo. METHODS: In this randomized, triple-blinded, placebo-controlled trial, 60 women (American Society of Anesthesiologists I/II, 18-75 years) undergoing bilateral reduction mammoplasty with immediate implant-based reconstruction received TXA 10&#x2005;mg/kg in 100&#x2005;mL saline or placebo 10&#x2005;min before incision. The primary outcome was total blood loss within 24&#x2005;h (intraoperative suction + swab plus drain output). Secondary outcomes were perioperative changes in hemoglobin, D-dimer and fibrinogen, and complications within 30 days. Intention-to-treat analyses were performed. RESULTS: All patients completed follow-up. Total blood loss was lower with TXA than with placebo (mean &#xb1; standard deviation: 221.1 &#xb1; 72.4 vs 298.1 &#xb1; 90.6&#x2005;mL; mean difference -77.0&#x2005;mL; 95% CI, -122.4 to -31.6; P = .001). Intraoperative loss and 24&#x2005;h drain output were also reduced. Postoperative D-dimer rise was attenuated with TXA (0.31 &#xb1; 0.15 vs 0.49 &#xb1; 0.22&#x2005;&#xb5;g/mL; P = .002); hemoglobin decline was smaller. No thromboembolic, neurologic, or allergic events occurred; no skin-flap necrosis was observed. CONCLUSIONS: Pre-incisional IV TXA safely reduces perioperative bleeding and fibrinolytic activity after reduction mammoplasty. These findings support incorporation of IV TXA into perioperative protocols. LEVEL OF EVIDENCE: 2 (THERAPEUTIC): For image description, please refer to the figure legend and surrounding text.

Humans

Intraocular Pressure Changes Following Intraluminal Stent Removal From the Paul Glaucoma Implant: A Systematic Review and Meta-Analysis.

PURPOSE: This study aims to systematically review and perform a single-arm meta-analysis to comprehensively evaluate the effect of removal of intraluminal stent from the Paul glaucoma implant (PGI) on intraocular pressure (IOP) changes and to summarize its long-term efficacy and safety. CLINICAL RELEVANCE: Glaucoma remains one of the leading global causes of irreversible vision loss, necessitating effective surgical management for refractory cases. Glaucoma drainage devices are critical for these complex forms, and intraluminal stent removal from the PGI serves as a key strategy to titrate aqueous outflow and optimize long-term IOP control. METHODS: A systematic review was conducted by searching EMBASE, Medline, and CENTRAL. The meta-analysis ultimately included 5 observational studies. The Risk of Bias in Nonrandomized Studies of Interventions (ROBINS-I) tool was used to assess the quality of the included studies. Continuous outcomes (eg, postremoval stent IOP reduction) were analyzed using the mean difference (MD) with 95% confidence intervals (CI); dichotomous outcomes (eg, hypotony incidence) were evaluated using pooled proportion with 95% CI. All meta-analyses employed a random-effects model. RESULTS: Our meta-analysis included 5 studies, involving a total of 283 eyes. The meta-analysis revealed that removal of the stent leads to a significant and immediate IOP reduction. The IOP reduction (immediate postremoval stent IOP minus preremoval stent IOP) was significant, with a pooled MD of -9.09 mm Hg IOP (MD = 9.09; 95% CI = [-11.77, -6.41]). In the preremoval stent high-IOP (>21 mm Hg) subgroup, the IOP reduction is -11.82 (95% CI = [-10.14, -13.51]). This reduction was significantly greater than the preremoval stent low-IOP (<21 mm Hg) subgroup, whose reduction is -6.66 mm Hg (95% CI = [-5.55, -7.77]). Regarding safety, the pooled proportion of clinically hypotony was low and highly consistent (I&#xb2; = 0.00%) at only 0.03 (95% CI = [0.00, 0.15]). CONCLUSIONS: Intraluminal stent removal from the PGI is an effective and safe IOP-lowering intervention. Its IOP reduction effect is significantly more pronounced in patients with preremoval stent high IOP, providing crucial clinical guidance for managing persistently high IOP after PGI implantation.

Humans

Risk Factors and Predictive Model for Postoperative High Myopia in Children Undergoing Congenital Cataract Surgery With Intraocular Lens Implantation.

PURPOSE: To identify risk factors associated with the development of high myopia following congenital cataract surgery and to establish a robust predictive model. DESIGN: Retrospective clinical cohort study. SUBJECTS: This retrospective study included 106 pediatric patients who underwent congenital cataract surgery with primary IOL implantation (mean follow-up 8.19 years). The model was externally validated in an independent cohort of 72 patients with a mean follow-up of 7.83 years. METHODS: Preoperative and postoperative ocular biometric parameters were collected. Risk factors for postoperative high myopia were analyzed using Cox proportional hazards regression, which served as the basis for model construction. The predictive performance of the model was rigorously evaluated for discrimination and calibration. Discriminative ability was quantified using Harrell's C-index and the area under the receiver operating characteristic curve (AUC). Model calibration was assessed via calibration plots by comparing predicted probabilities with actual observed outcomes. Internal validation was performed using a bootstrapping method (500 iterations) to ensure model stability and adjust for potential overfitting. RESULTS: An initial postoperative refraction of <+0.75D, and a higher IOL Power to Axial length Ratio (IOL/AL ratio) were identified as significant risk factors for the development of postoperative high myopia. Shorter preoperative axial length was associated with a greater magnitude of postoperative myopic shift. The predictive model demonstrated robust performance, achieving a C-index of 0.711 (internal validation C-index: 0.713). The area under the receiver operating characteristic curve (AUC) values for predicting high myopia at 5 and 10 years were 0.858 and 0.745, respectively. Furthermore, calibration curves demonstrated excellent agreement between the predicted and observed outcomes throughout the follow-up period. In external validation, the model achieved a C-index of 0.825, 5-year AUC of 0.833, and 10-year AUC of 0.713. CONCLUSIONS: Our analysis established that initial postoperative refraction <+0.75D, and an elevated IOL/AL ratio are key determinants of high myopia risk following surgery. Shorter preoperative axial length was associated with a greater magnitude of postoperative myopic shift. This predictive framework provides clinicians with a practical tool to optimize preoperative IOL selection and identify high-risk infants who require vigilant myopia prevention and balanced amblyopia management.

Humans