Search PubMedSearch

SEARCH · Search PubMed

Results for “measurement error”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

579 recordsLinked to original sources

Test-retest reliability of spatiotemporal, kinematic, and kinetic measures in marker-based 3D gait analysis: A systematic review.

BACKGROUND: Marker-based 3D gait analysis (3DGA) is widely used to quantify impairments and evaluate treatment effects. For longitudinal clinical interpretation, clinicians and researchers need reference values for inter-session measurement error. For this purpose, this systematic review synthesized Standard Error of Measurement (SEM) values for spatiotemporal, kinematic, and kinetic (moments) outcomes obtained from marker-based 3DGA studies. METHODS: PubMed and Scopus were searched (final search: 11 December 2025). Studies reporting inter-session test-retest SEM and/or MDC for steady-state overground or treadmill walking using marker-based motion capture were included. Two authors screened records and appraised methodological/reporting quality using a custom tool informed by COSMIN, GRRAS, and biomechanics-specific items. Due to heterogeneity, results were synthesized descriptively using study-level median SEM values, stratified by joint, plane, population (healthy, pathological, single subgroups), and walking condition. Minimal Detectable Change (MDC) values were computed for all available data. RESULTS: Thirty-four studies (762 participants, 44.2% females) were included, with substantially more evidence for overground than treadmill walking. Overground spatiotemporal outcomes showed low errors (walking speed SEM of 0.06 m/s; timing typically ≤0.03 s; spatial parameters generally ≤0.03 m). For joint kinematics during overground walking, median SEMs were 2.4° (sagittal), 1.9° (frontal), and 3.3° (transverse). The corresponding joint-kinetic SEMs were approximately 0.06, 0.04, and 0.03 Nm/kg, respectively. Treadmill data followed similar patterns. SIGNIFICANCE: Marker-based 3DGA allows for accurate assessment of spatiotemporal, kinematic, and kinetic gait features. We provided detailed SEM/MDC lookup tables to support clinical decision-making. Results further offer a benchmark for validating emerging gait assessment technologies (e.g., markerless systems) against realistic limits of marker-based 3DGA.

Humans

Effects of Dynamic Neck Sensorimotor Biofeedback Training in Individuals With Mechanical Neck Pain: A Pilot Randomized Controlled Trial.

Mechanical neck pain (MNP) is commonly accompanied by pain-related functional limitations, sensorimotor disturbances, and fear of movement, which together may contribute to persistent disability. This preliminary randomized controlled trial study investigated the short-term effects of dynamic neck sensorimotor-based biofeedback training in individuals with MNP. 20 MNP patients from outpatient clinics were assigned to a biofeedback training group or a control group. The training group underwent dynamic biofeedback exercises twice weekly for 2&#xa0;weeks, whereas the control group performed repeated cervical movements without biofeedback. Outcomes included cervical kinematics as repositioning errors (RPE), movement units (MU), maximal range of motion (ROM), and subjective measures, including pain intensity, Neck Disability Index (NDI), and Fear-Avoidance Beliefs Questionnaire (FABQ). All participants completed post-intervention assessments; adherence in the training group was 100%, with no missing data and no adverse events reported. Within the biofeedback training group, participants receiving biofeedback training demonstrated greater improvements in cervical repositioning accuracy during flexion (51.95%, p&#xa0;=&#xa0;0.04) and extension (46.67%, p&#xa0;=&#xa0;0.02), along with reductions in fear-avoidance beliefs related to physical activity and work (p&#xa0;<&#xa0;0.05); these changes were less apparent in the active control group. Exploratory regression analyses suggested associations between improvements in repositioning accuracy and pain reduction, and between increased cervical range of motion and improvements in fear-avoidance beliefs related to physical activity. These pilot findings suggest that dynamic sensorimotor biofeedback training may improve proprioceptive acuity and fear-avoidance beliefs in individuals with MNP, supporting further evaluation in an adequately powered randomized trial.

Humans

The influence of organizational culture on medication safety practices and associated risk factors in the community setting: A systematic review.

BACKGROUND: Increasing attention has been given to the role of organizational culture in influencing medication safety practices across healthcare settings. The lack of widely accepted standardized instrumentation makes operational measurement of organizational culture and medication safety challenging. The purpose of this systematic review was to examine the impact of organizational culture on medication safety within community healthcare settings. METHODS: MEDLINE, CINAHL, Scopus, and Nursing & Allied Health were searched in August 2025 using keywords, subject terms, field codes, and Boolean operators to identify papers relevant to the review question; bibliographies of included studies were also reviewed. Screening and full-text review were completed independently by two reviewers with a third to adjudicate conflicts. The Critical Appraisal Skills Programme was used for quality assessment. The PRISMA statement guided the development and implementation of the review. RESULTS: Thirteen articles were included representing various community settings. Most studies reported on untoward medication events, but few measured systematically collected safety data before and after an intervention. Organizational culture was seldom defined or operationalized. Most studies were methodologically sound, but the overall level of evidence was weak to moderate. CONCLUSION: Organizational culture influences medication safety through aspects such as communication channels, teamwork, training, and an environment that allows error and near-miss reporting. Few studies explicitly evaluate the causal impact of culture interventions on measurable medication safety outcomes in community healthcare settings. Further research should incorporate standardized measurement tools and intervention-based, pre-post designs to better understand how organizational culture influences medication safety in community healthcare settings.

Organizational Culture

List randomization for prevalence estimation of sensitive behavioral data among women with HIV of reproductive age in Lilongwe, Malawi.

Self-reported data are subject to reporting biases, including social desirability bias. List randomization is one method that can help mitigate the impact of such biases. Here, we examined the utility of list randomization among women of reproductive age living with HIV in sub-Saharan Africa. In the Family Planning and Antiretroviral Therapy study, participants were randomized to answer 5 blocks of true/false statements via either direct or list response. Each block contained 3 nonsensitive statements and 1 sensitive statement related to either condom use or HIV disclosure. For each sensitive statement, we calculated the prevalence difference (PD) comparing list response to direct response overall and stratified by socioeconomic status. The PD for 4 of the sensitive statements was negligible. However, we found that self-report of always using a condom was reported by 53.1% at list response visits vs 34.7% at direct response visits (PD, 18.5%; 95% CI, 6.2%-30.7%), a difference that was attenuated among those with higher socioeconomic status. In this setting, list randomization did not meaningfully change the estimated prevalence for most questions, except for one question, which unexpectedly produced a higher estimate for a positive behavior. Examining this method in other settings and populations is warranted.

Humans

Sitosterolemia: evolving strategies for earlier diagnosis.

PURPOSE OF REVIEW: Sitosterolemia is a rare autosomal recessive lipid disorder caused by biallelic pathogenic variants in ABCG5 or ABCG8 , resulting in excessive intestinal absorption and impaired biliary excretion of plant sterols. Although historically considered exceptionally rare, recent genetic studies suggest the disorder is substantially underdiagnosed, with marked phenotypic heterogeneity ranging from xanthomas and premature atherosclerosis to hematologic abnormalities, and frequently mimics familial hypercholesterolemia. This review summarizes recent advances in the clinical, biological, and genetic diagnosis of sitosterolemia, with a focus on strategies that may facilitate earlier detection. RECENT FINDINGS: Phytosterol quantification, particularly sitosterol, campesterol, and stigmasterol, remains indispensable for accurate diagnosis. Hematologic abnormalities, including hemolytic anemia, stomatocytosis, and macrothrombocytopenia, are increasingly recognized as valuable diagnostic clues complementing the biochemical approach. Expanded variant catalogs for ABCG5/ABCG8 and genome-wide association studies have revealed potentially polygenic contributions to phytosterol metabolism extending beyond these two genes. However, no specific guidelines have yet been established for cascade screening. SUMMARY: Earlier diagnosis requires integration of clinical, biochemical, hematologic, and genetic data. Plasma phytosterol measurement remains the diagnostic cornerstone. Improved disease awareness, broader access to sterol testing, and expanded genetic screening may reduce diagnostic delays and enable timely management, including ezetimibe and dietary phytosterol restriction.

Humans

Patient-reported outcome measures for depression or anxiety symptoms in patients with cardiovascular disease: A COSMIN systematic review.

BACKGROUND: Depression and anxiety are common in patients with cardiovascular disease (CVD), but the measurement quality of patient-reported outcome measures (PROMs) used in this population remains unclear. This review aimed to evaluate the methodological quality, measurement properties, and certainty of evidence for depression and anxiety PROMs in adults with CVD and to inform instrument selection. METHODS: Following COSMIN and PRISMA guidance, four databases were searched from inception to February 2026. Studies assessing measurement properties of PROMs in adults with CVD were included. Methodological quality was evaluated using the COSMIN Risk of Bias checklist, and certainty of evidence was graded using an adapted GRADE approach. RESULTS: Sixty-six studies assessing 38 PROMs were included, comprising 29 generic and 9 CVD-specific instruments. Six PROMs met COSMIN Category A criteria: Cardiac Depression Scale-Short Form, Patient Health Questionnaire-9, Beck Depression Inventory-II, Hospital Anxiety and Depression Scale, Generalized Anxiety Disorder-7, and Major Depression Inventory. Four instruments were classified as Category C because of insufficient structural validity. Content-validity evidence was largely indeterminate or of limited certainty. Only 24 studies used confirmatory factor analysis or Rasch analysis, and no study assessed measurement error or responsiveness. Cross-cultural validity evidence was scarce. CONCLUSIONS: Six PROMs met Category A criteria, but selection should remain purpose- and context-specific. Particular attention should be given to somatic symptom overlap and intended clinical use. Further validation should prioritize content validity, measurement invariance, responsiveness, measurement error, and clinimetric performance.

Humans

Associations between smart infusion pump-electronic health record interoperability and healthcare outcomes: A systematic review.

OBJECTIVE: This study synthesized available evidence on the associations between smart infusion pump-electronic health record (EHR) interoperability and healthcare outcomes. METHODS: A systematic review of PubMed, CINAHL, Embase, and Scopus databases identified 901 records, which were imported into Rayyan&#xae; for duplicate removal, independent screening by three reviewers, and resolution of discrepancies. Eligible studies were peer-reviewed, data-driven, and reported associations between smart infusion pump-EHR interoperability and healthcare outcomes. Studies focused solely on technical validation or interoperability prototypes were excluded. A backward citation search identified additional studies. Two reviewers independently extracted and cross-validated study characteristics using standardized templates. Methodological quality was assessed with the Joanna Briggs Institute Critical Appraisal Tools. RESULTS: Twenty records of 14 full-text studies and 6 conference proceedings were included. Most records reported positive associations between smart infusion pump-EHR interoperability and outcomes related to safety (e.g., medication administration errors, safety-reported events, pump alerts, and compliance with interoperability and drug library), operational efficiency (e.g., programming and documentation time and technical issues), financial performance (e.g., charges captured, and cost avoided), and user experience domains. Most studies used observational designs, reflecting real-world interoperability implementations, where controlling confounding factors is challenging. Limited reporting of baseline characteristics, pump type, and sample sizes limited comparability across studies. CONCLUSIONS: Smart infusion pump-EHR interoperability was associated with improvements in patient safety, efficiency, charge capture, and user experience, with variable findings across studies. Future research should use rigorous methodologies and standardized measures, examine relationships across outcome domains, assess limitations of pump-EHR interoperability, and evaluate underexplored outcomes, including team communication, cognitive workload, and AI-enabled pumps. IMPLICATIONS FOR CLINICAL PRACTICE: Interoperability should be viewed as a component of a broader sociotechnical system, in which technology, user, workflow, clinical content, and organizational practices collectively determine overall effectiveness.

Humans

Pictographs: feasibility and acceptability of a novel method of newborn identification to reduce wrong-patient errors in the NICU.

Wrong-patient errors cause serious harm in newborns. These errors involve ordering and administering tests, procedures, medications, and breast milk to an unintended patient. Newborns receiving care in neonatal intensive care units (NICUs) are at particularly high risk. Although more distinct newborn naming conventions as recommended by the Joint Commission significantly reduce wrong-patient orders, name similarities among multiple-birth infants and truncation of differentiating information in some electronic health record (EHR) systems contribute to this persistent increased risk. Accordingly, novel newborn identifiers are urgently needed. We propose Pictographs&#xa0;-&#xa0;images that are appealing, recognizable, and appropriate&#xa0;-&#xa0;to serve as visual identifiers for newborns in NICUs. Pictographs are selected by caregivers, uploaded into the EHR, and displayed at bedside. As part of a multicenter randomized controlled trial assessing effectiveness of Pictographs to prevent wrong-patient order errors, we initially evaluated feasibility and acceptability of Pictographs at two study sites. Pictographs as novel visual identifiers for newborns in the NICU were generally well received by caregivers and clinicians, and the vast majority of caregivers selected a Pictograph for their infant(s), which was posted at the bedside and uploaded into the EHR. Ordering clinicians&#xa0;-&#xa0;the primary target of the intervention to prevent wrong-patient errors&#xa0;-&#xa0;recognized the potential for Pictographs to provide a visual cue when placing orders, particularly for multiple-birth infants. Here, we describe the rationale, implementation, framework, feasibility, usefulness, and acceptability of Pictographs among key stakeholders. If found effective for preventing wrong-patient errors, Pictographs could be adopted as a patient safety solution in hospitals worldwide.

Female

Family-Wise Error Rate Control in Clinical Trials With Overlapping Populations.

We consider clinical trials with multiple, overlapping patient populations that test multiple treatment policies specifically tailored to these populations. Such designs may lead to multiplicity issues, as false statements will affect several populations. For type I error control, often the family-wise error rate (FWER) is controlled, which is the probability to reject at least one true null hypothesis. If the joint distribution of the test statistics is known, the FWER level can be exhausted by determining critical values or adjusted-levels. The adjustment is typically done under the common ANOVA assumptions. However, the performed tests are then only valid under the rather strong assumption of homogeneous null effects, that is, when the null hypothesis applies to all subpopulations and their intersections. We show that under cancelling null effects, when heterogeneous effects cancel out in some or all subpopulations, this procedure does not provide FWER control. We also suggest different alternatives and compare them in terms of FWER control and their power.

Humans

The effect of olfactory training and odor exposure on visual selective attention.

Olfactory training (OT) is a well-established, non-invasive intervention that improves olfactory function by repeated, structured exposure to odorants. Beyond sensory outcomes, it also influences multiple aspects of cognition. Yet, its influence on attention, a fundamental process underlying many cognitive domains, remains unclear. This study examined the impact of a 12-week OT program on visual selective attentional performance and the effect of on-task odor exposure. Ninety-four healthy participants were initially included, and randomized into OT or placebo groups. Participants completed the d2 Test of Attention simultaneously with and without odor exposure in a randomized sequence at baseline, post-training, and a follow-up four weeks after stopping the training. The d2 test measures commission errors, omission errors, and concentration performance. Ninety-three participants (OT=51, placebo=42) completed baseline measurement, 74 (OT=39, placebo=35) returned for post-training session, and 57 participants (OT=29, placebo=28) returned for the follow-up appointment. Results showed that OT did not significantly improve d2 test performance. In the primary model, on-task PEA exposure reduced commission errors compared to the odorless condition, suggesting a possible transient effect of olfactory input on the inhibitory control in the context of the d2 attentional test. This effect, however, was no longer significant once the follow-up data were included and should be regarded as preliminary. Overall, these findings raise the possibility of a distinction between relatively long-term OT and short-term odor exposure: while OT did not improve visual selective attention, brief on-task odor exposure may transiently enhance inhibitory control during attentional tasks, a possibility that remains to be confirmed.

Humans

An Update on Inborn Errors of V(D)J Recombination.

V(D)J recombination is the fundamental process by which developing T and B lymphocytes generate diverse antigen receptors, enabling adaptive immunity. This tightly regulated program operates exclusively in lymphoid precursors during G1 phase and depends on the lymphocyte-specific RAG1-RAG2 recombinase to introduce programmed DNA double-strand breaks at recombination signal sequences, followed by repair through the classical nonhomologous end joining (c-NHEJ) pathway. Disruption of any step in this molecular choreography compromises antigen receptor diversity and underlies a spectrum of inborn errors of immunity (IEIs), ranging from severe combined immunodeficiency (SCID) to immune dysregulation with autoimmunity and granulomatous disease. In this review, we place disorders of V(D)J recombination within the broader framework of T-cell development, detailing the temporal waves of recombinase activity, chromatin accessibility, and DNA damage responses that guide thymocyte differentiation. We discuss pathogenic variants affecting the cleavage phase [RAG1, RAG2, and the recently identified RAG cochaperone NudC domain-containing 3 (NUDCD3)], end processing (ARTEMIS), ligation and repair (LIG4, XLF, XRCC4, PRKDC), and genome surveillance pathways (ATM, MRN complex, RNF168), highlighting genotype-phenotype correlations and mechanisms driving immune deficiency and dysregulation. We briefly review recent diagnostic advances, including newborn screening using T-cell receptor excision circles, repertoire sequencing, and functional assays, alongside current therapeutic strategies. Finally, we outline key unanswered questions and argue that continued integration of clinical observation with molecular discovery is essential to improve outcomes and deepen understanding of adaptive immune development.

Humans

Smartphone Apps for Preventing Adolescent Health Problems Among Health Care Professionals: Systematic Search and Quality Assessment.

BACKGROUND: Health care professionals must consider multiple dimensions of prevention when consulting with adolescents. Identifying risky behaviors early in adolescence is crucial for reducing both morbidity and mortality. General practitioners are increasingly eager to incorporate digital tools for prevention into their consultations with adolescents; however, the relevance and clinical validity of these digital tools are not always established or well-known. Consequently, primary care professionals require guidance and support in selecting relevant mobile health (mHealth) tools. OBJECTIVE: The aim of this study is to identify relevant and useful digital apps to help primary care professionals detect at-risk adolescents across all recommended areas of prevention: orthopedics, mental health, substance abuse, risk behaviors, sexual health, vaccinations, social relationships, and nutrition. METHODS: A systematic review of smartphone apps, with an analysis of content quality, was carried out by 4 researchers using the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) checklist. The App Store and Google Play Store platforms were surveyed. The inclusion criteria were as follows: free of charge, date of last update, availability in French or English, relevance of the preventive approach to adolescents, and scientific validation. Four health care professionals assessed the apps: 2 selected the apps relevant to health care professionals, then 3 analyzed these apps using the French version of the Mobile App Rating Scale (MARS-F). Intraclass correlation coefficient, model (2,1) (2-way random effects, absolute agreement, single measures); standard error of measurement; and mean absolute error were also calculated. RESULTS: A total of 976 apps were identified, 49 of which had disappeared from the platforms prior to analysis. Nine apps were retained. Seven (0.72%) were included after evaluation using the MARS-F: 2 on mental health and 5 on sexual health (including 3 on contraception only). The mean MARS-F interrater score ranged from 2.5/5 to 3.8/5. The global MARS-F score demonstrated a pooled SD of 0.60 and an intraclass correlation coefficient (2,1) of 0.0003, resulting in a calculated standard error of measurement of 0.60. The average discrepancy between raters was a mean absolute error of 0.53. CONCLUSIONS: No similar studies have been identified in the literature that specifically focus on mobile apps designed to support health care professionals in delivering preventive care to adolescents. Of the 8 areas of prevention identified as relevant for adolescents, only 3 are addressed by the apps validated through our methodology (5 focus on sexual health). Consequently, current apps are insufficient to support health care professionals in their overall preventive work with adolescents. Such a review should be conducted systematically prior to the development of any new tool to prevent duplication and channel creative efforts toward truly innovative digital solutions. Furthermore, a thorough analysis of relevant, recommended websites is essential, as these resources complement the use of mobile apps designed for health care professionals.

Humans

Beyond Photometric Consistency: Addressing Loss Insensitivity to Depth Noise in Endoscopic Estimation via Error Calibration.

Self-supervised monocular depth estimation in endoscopy is fundamentally constrained by the ill-posed nature of photometric supervision. In this work, we identify a critical yet overlooked cause of this ambiguity: the inherent insensitivity of photometric loss to depth noise. To overcome this intrinsic limitation, we propose Depth Error Calibration Learning (DECL), a two-stage framework that suppresses prediction variance and mitigates residual errors in self-supervised depth estimation. In Stage I (Variance Reduction), a cyclic depth generation strategy produces multiple depth hypotheses for the input image. The per-pixel empirical variance is quantified and integrated into a dedicated variance loss term, which penalizes inconsistent predictions and encourages the network to generate more stable and reliable depth estimates. In Stage II (Bias Calibration), an image-conditioned diffusion model refines the Stage-I depth prior and mitigates structured residuals through iterative denoising, thereby improving geometric accuracy and global consistency. Extensive experiments on three public endoscopic datasets demonstrate that DECL achieves consistent improvements over representative self-supervised monocular depth estimation methods under the evaluated protocols. Moreover, ablation studies on two representative backbones indicate that DECL is not restricted to a single network implementation, while broader validation on additional backbone families remains necessary. The source code is publicly available at https://github.com/DavidLuBit/EndoDenoising.

Journal Article

Angiotensin II regulates anxiety and social-affective top-down and bottom-up attention control in a sex-dependent manner.

BACKGROUND: The renin-angiotensin system (RAS) has been increasingly recognized as potent modulator of cognitive and affective functions, with angiotensin II type 1 receptor (AT1R) antagonists emerging as repurposing candidate for anxiety and stress-related disorders. However, it remains unclear whether transient AT1R blockade modulates emotional attentional control and whether these effects are sex-dependent. METHODS: We conducted a preregistered, randomized, double-blind, placebo-controlled pharmacological eye-tracking study in 79 healthy adults (males and females) and determined effects of transient AT1R blockade via losartan (50&#xa0;mg) on emotional attention control using a validated anti-saccade paradigm with social (emotional faces) and non-social stimuli. Treatment effects on state anxiety and oculomotor responses were characterized using traditional metrics and a novel trial-history informed dynamic control framework. RESULTS: Losartan reduced state anxiety irrespective of sex but induced sexually dimorphic effects on attentional control. In females, losartan enhanced performance by reducing endpoint error without altering latency. Conversely, in males, losartan increased endpoint error and prolonged latency of the first correct saccade. Trial-history analyses revealed losartan reduced error probabilities following errors and repeat trials in both sexes. Yet, following correct trials, females receiving losartan maintained lower error probabilities, while males exhibited higher errors, potentially reflecting failure to disengage from effortful control. CONCLUSIONS: The RAS modulates anxiety and attentional control, the latter sex-dependently. AT1R blockade reconfigures attentional processing and adaptive control, suggesting sex-specific therapeutic potential in disorders characterized by excessive anxiety and attentional dysregulation. CLINICAL TRIALS REGISTRATION: ClinicalTrials.gov; https://clinicaltrials.gov/;NCT06329050.

Humans

RR-interval-based atrial fibrillation detection and burden estimation: cross-dataset validation and calibration-aware probability analysis.

Objective.Atrial fibrillation (AF) burden has become an increasingly important endpoint in long-duration rhythm monitoring, but reliable burden estimation requires more than accurate AF detection alone. In particular, when burden is derived by aggregating predicted AF probabilities over time, probability calibration may directly affect burden validity under external dataset shift.Approach.This study developed an interpretable-interval feature model for AF detection and evaluated it using record-wise cross-validation on a development cohort and independent cross-dataset external validation on public Holter electrocardiographic databases. Window-level performance was assessed using the area under the receiver operating characteristic curve (ROC-AUC), area under the precision-recall curve (PR-AUC), Brier score, expected calibration error (ECE), and calibration intercept and calibration slope. Recording-level AF burden was estimated using both probability-based and hard-label aggregation and evaluated using mean absolute error (MAE) and agreement analyses.Main results.The model showed high discrimination in both development and external evaluation, with external ROC-AUC ofand PR-AUC of. However, external calibration deteriorated despite preserved ranking performance, with Brier score of, ECE(15) of, calibration intercept of, and calibration slope of. In the external cohort, probability-based burden estimation preserved strong association with reference burden but showed weaker raw agreement than hard-label aggregation, with MAE ofversus, consistent with systematic probability underprediction. Repeated external recalibration across record-level splits substantially improved probability quality and probability-based burden estimation. Median probability-burden MAE decreased fromwithout recalibration toafter Platt recalibration andafter isotonic recalibration, while median ECE(15) decreased fromtoand, respectively.Significance.These findings indicate that-interval-based AF detection maintained strong ranking performance in the tested external cohort, but probability calibration should be evaluated explicitly when predicted probabilities are aggregated into AF-burden estimates.

Atrial Fibrillation

Axial Length Adjustment and AL/R Ratio Optimization of IOL Power Calculation in Extremely Long Eyes.

PURPOSE: To evaluate the accuracy of modern intraocular lens (IOL) power calculation formulas and axial length (AL) adjustment methods in eyes with AL &#x2265; 30.0 mm. DESIGN: Retrospective consecutive cross-sectional study. PARTICIPANTS AND CONTROLS: A total of 308 eyes (308 patients) with AL &#x2265; 30.00 mm were included. METHODS: Accuracy of modern online formulas, alone or with established AL adjustments methods, was analyzed. Subgroup analyses were performed based on AL, keratometry (K), anterior chamber depth (ACD), lens thickness (LT), and AL-to-corneal radius (AL/R) ratio. MAIN OUTCOME MEASURES: Predictive accuracy was evaluated using the formula performance index (FPI), root mean square absolute prediction error (RMSAE), standard deviation (SD) of prediction error (PE), and percentage of eyes within &#xb1;0.25 and &#xb1;0.50 diopters (D). RESULTS: Overall, Holladay 1 combined with the nonlinear polynomial Wang-Koch axial length adjustment (H1-PWK) demonstrated the best overall performance, achieving the lowest SD (0.40), RMSAE (0.40), and highest FPI (0.494). A tendency toward hyperopic error was observed in eyes with AL &#x2265; 32.0 mm, K &#x2265; 46.0 D. The AL/R ratio showed a significant positive correlation with PE in the Ladas Super formula, Barrett Universal II, EVO, PEARL-DGS, and Hoffer QST formulas. Spline-based regression analysis indicated that the transition point of AL/R from myopic to hyperopic PE varied across different formulas. CONCLUSIONS: H1-PWK provides robust refractive accuracy in extremely long eyes. The AL/R ratio may provide a useful composite biometric stratification parameter compared to AL alone.

Humans

Pilot Distractions and Interruptions in Airlines: Ranking of Sources by Analytic Hierarchy Process.

ObjectiveThis work establishes a methodological framework for sources of pilot distraction and interruptions in a structured model that can be used as a tool for cockpit design/procedure assessment.BackgroundPilots must complete complex tasks, and distractions can impair performance and lead to errors that can cause aircraft accidents. Although various cockpit distractors are examined individually, there is no integrated approach.MethodDistraction and interruption sources were identified through a literature review and confirmed/extended by interviews with airline pilots. Associated weights were determined through pairwise comparisons, yielding a hierarchical model using the Analytic Hierarchy Process.Results26 sources of pilot distraction and interruptions were quantified and categorized into four categories: communication, head-down time, responding to abnormal conditions & unexpected situations, and searching for traffic.ConclusionA taxonomic structure for assessment is achieved with the top 5 sources identified as communications, technical interruptions, experience in type, environmental factors, operational irregularities, and airspace high terrain, accounting for 63.07%.ApplicationThe structured system is a flexible assessment scale that provides a taxonomic framework for airline risk management, supports future research, and cockpit design efforts.

Humans

Civil liability in oral & maxillofacial surgery: &#x391; systematic review.

Maxillofacial surgery is a surgical specialty with anatomical, functional, and aesthetic requirements, which makes it a field at increased risk of medical negligence and subsequent legal claims. The review was conducted in accordance with the PRISMA guidelines and used international medical and legal databases. Studies that analyzed court decisions, insurance claims, or recorded compensation data related to maxillofacial surgery were included. The extracted data included, among others, the year and country of publication, the causes of action, and the amounts of financial compensation. Most lawsuits originate from countries with developed medical liability systems, primarily the United States and the United Kingdom, and there has been an increasing trend in publications over the last two decades. The most common causes of lawsuits involve nerve injuries, delayed or incorrect diagnoses, technical errors during surgery, and inadequate informed consent. The amounts of compensation vary widely, from lower five-digit amounts in milder cases to particularly high amounts in cases of permanent functional or aesthetic damage, placing a significant overall financial burden on health systems. Medical negligence in maxillofacial surgery constitutes an important forensic and socioeconomic issue. Understanding the causes of lawsuits and their financial consequences can help improve clinical practice, inform patients, and prevent legal disputes.

Humans