Search PubMedSearch

SEARCH · Search PubMed

Results for “imaging”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

Investigation of basic imaging properties in digital radiography. 11. Multiple slit-beam imaging technique with image intensifier-TV digital system.

We are developing a digital x-ray imaging system using a multiple slit assembly (MSA) and an image intensifier (II)-TV digital system. The advantage of this approach is that the scatter from an object and the veiling glare in the II-TV system can be reduced significantly while the x-ray utilization is maintained much better than that with a single slit-beam technique. The quality of reconstructed images is related to many parameters such as the slit width, the lead spacer, the number of image frames, and the reconstruction algorithm. In this study, reduction of scatter and veiling glare was measured quantitatively, and image artifacts were analyzed. It was found that the fraction of scatter and veiling glare can be reduced to approximately 0.01-0.1 by use of the MSA imaging technique, and that the magnitude of the fractions is strongly dependent upon the slit width and the lead spacer of the MSA used. The artifacts are caused by inaccuracies in the slit width, lead spacer, and scan motion, and by undersampling of image data. The overlap scanning technique was effective in reducing the magnitude of these artifacts in the reconstructed image.

Humans

Tapetool: a software tool for importing image data from image acquisition computers to image processing computers.

Currently, the image distribution gap between image acquisition computers and image processing computers is bridged through magnetic tapes. The tape formats used by the manufacturers of the image acquisition computers are idiosyncratic and fairly complex. A general purpose window based software tool is herein described, which frees the clinical and research sectors of the responsibility of understanding and decoding these complex formats in order to import image databases from acquisition computers to image processing computers. This software tool provides a cornerstone for developing image processing software for diagnostic, therapeutic and surgical planning purposes.

Algorithms

Near-infrared imaging in vivo (I): Image restoration technique applicable to the NIR projection images.

To enhance spatial resolution of NIR projection images in vivo, we performed refocusing of NIR projection images of human forearm of about 50 mm thickness. A volunteer's forearm was illuminated by parallel light beam-flux, and then projection images at 750 nm was measured with a Pertier-cooled CCD video camera and digitized. For refocusing computation, PSF of the light transmitted through the tissue was calculated by general equation proposed by van der Zee and Delpy (1988). Simple inverse, constrained least squares, and Wiener filters were tested as refocusing algorithms. Wiener filter gave the best result in terms of image quality and computation time. By applying Wiener filter to the image refocusing of NIR projection images of human forearm, we obtained enhanced spatial resolution.

Evaluation Studies as Topic

MR imaging of the portal venous system: value of gradient-echo imaging as an adjunct to spin-echo imaging.

We evaluated the use of gradient-echo (GRE) as an adjunct to spin-echo (SE) MR imaging of the portal venous system. GRE imaging was performed in 31 subjects, 15 normal volunteers and 16 patients with documented portal venous disease (15 cases) or suspected disease (one case). Eight of 16 patients had venous thrombosis, five had focal thrombus, and three had complete occlusion. Six patients had extrinsic venous compression by tumor. Of the two other patients, one had an arteriovenous fistula and the other a falsely positive angiogram, suggesting portal vein occlusion. In normal subjects, GRE scans had excellent visualization of the portal venous system with high intravascular signal compared with surrounding tissues. Nine (60%) of 15 normal subjects and three patients had an artifact consisting of a curvilinear area of decreased signal that could mimic clot. In three of five patients with focal thrombus, clot was identified on GRE but not on SE images. In all three patients with occlusion, SE and GRE images demonstrated similar findings. In five of the six patients with extrinsic venous compression by tumor, SE and GRE studies showed similar findings. Of the two patients, an arteriovenous fistula was seen on GRE MR in one, and in the other, patency of the left portal vein was seen on SE and GRE images after angiography had suggested portal vein occlusion. Collateral vessels were seen in nine of 16 patients. In five of nine cases, GRE MR demonstrated more extensive collaterals than did SE MR. In summary, GRE MR provides a useful adjunct to standard SE MR imaging. Benefits include high contrast between vascular structures and surrounding tissues, reduced motion artifact, and rapid scanning within a breath-hold.

Adolescent

[Image diagnosis of adrenal disorders--I. CT images of control subjects and image diagnosis of primary aldosteronism].

The shape and size of the adrenals in control subjects without adrenal disorders were studied by computed tomography (CT), and a comparative assessment of diagnostic values of ultrasonography (US) by electronic linear scanner, CT, and adrenal scintigraphy was made on 9 patients with primary aldosteronism. Adrenal imaging by scintigraphy was performed on the 5th and 6th day, or further on the 7th day after the injection of 1 mCi of Adosterol. CT findings of the adrenals in control subjects: Eighty-two % of 100 control right adrenals, and 89% of 100 control left adrenals were detected by CT. Seventy-seven % of the right adrenals were in linear-shape, and the others were in V-shape. The shape of the left adrenals could be classified into triangular-shape (54%), Y-shape (28%) and V-shape (18%). The mean width and thickness of the right adrenals were 28.6 +/- 7.5 mm (M +/- SD) and 3.8 +/- 1.4 mm, respectively. Those of the left ones were 19.4 +/- 5.5 mm and 5.3 +/- 1.8 mm. Image diagnosis of primary aldosteronism: In 2 out of 3 patients examined by US, aldosteronomas were detected. In these 2 patients, one had 2 adenomas 2.8 X 1.7 X 1.2 cm and 1.0 X 1.0 X 2.0 cm in size, and the other had one adenoma 0.8 X 1.0 X 2.0 cm in size. On adrenal scintiscanning under dexamethasone pretreatment (DP), the isotope uptake of aldosteronoma was still seen with the disappearance of the contralateral adrenal in 7 out of 9 cases. In these 7 cases, the laterality of the tumor was confirmed. In one of the remaining 2 cases, the bilateral adrenal images were obtained regardless of DP. In the other case, of which aldosteronoma was the smallest (0.6 X 0.6 X 0.8 cm), the image of the affected adrenal with adenoma as well as the contralateral adrenal disappeared under DP. CT delineated all aldosteronomas in 8 cases examined including 2 cases in which adrenal scintiscanning failed to elucidate the localization of aldosteronoma. These results indicated that the combination of these 3 new image diagnostic methods was available for the detection of aldosteronomas of various sizes.

Adenoma

Respiratory gating in magnetic resonance imaging: improved image quality over non-gated images for equal scan time.

Magnetic resonance image quality is adversely affected by respiratory (RESP) motion during the scan. Respiratory gating improves magnetic resonance image (MRI) quality and removes artifacts, but has not been widely used, as RESP gating increases scan time. Our RESP-gating device was used to study scan time versus improvement in image quality using various gating modes; with and without combined electrocardiographic (ECG) gating. When RESP scans were acquired for the same time as non-gated scans, by using a wide RESP-gating window bracketing end expiration and a reduced number of pulse sequence repetitions, substantial improvement in image quality (over non-gated scans) resulted, despite the inferior statistical content of the acquisition.

Abdomen

[Lung imaging in intensive medicine. A comparison of digital storage-screen imaging and conventional film-screen imaging].

Luminescence radiography is a new digital imaging modality, which can be used instead of conventional film radiography for many examinations. Imaging capabilities of luminescence radiography were compared with film radiography by test images and examinations especially in intensive care radiology. The results demonstrate, that luminescence radiography is an advantageous imaging method for intensive care radiology.

Humans

Interrelationships between the heart and central nervous system: localization of neuro-transmitters and imaging of their associated nuclei, including the raphe nuclei & the locus coeruleus, as well as the imaging of the heart and its representation areas in slices of the human central nervous system using the "Bi-Digital O-Ring Test" imaging method.

Using microscopic slides of specific tissues from the human body or pure substances including neuro-transmitters such as serotonin, dopamine, norepinephrine, etc., as reference control substances in the Bi-Digital O-Ring Test Molecular Identification Method, the author was able to localize and image normal and abnormal internal organs, and to localize and trace the distribution of neurotransmitters in the different parts of the central nervous system. Using microscopic slides of different parts of the heart, we were able to image the outline of the heart as well as the SA node, AV node, tricuspid valve, mitral valve, aortic valve, pulmonary valve, coronary arteries, and aorta and its branches, including the vertebral arteries, without using any bulky or expensive imaging instruments. Using serotonin as a reference control substance on the different parts of the central nervous system, it was possible to demonstrate the 6 well-known raphe nuclei and the locus coeruleus (which contains serotonin & norepinephrine), as well as the distribution of serotonin in the cerebrum and the cerebellum, all of which closely resembled previously published well-known neuroanatomical structures and distributions of neurotransmitters. As an extension of this work, possible representations of different internal organs on the central nervous system were examined using microscopic slides of different internal organs as reference control substances. The results indicated that the entire heart is represented primarily in the medulla oblongata, and that the SA node and the upper half of the left atrium are represented in the caudal end of the pons; the right side of the heart (i.e. R-atrium, AV node, tricuspid valve, R-ventricle) is represented on the right side of the medulla oblongata, and the left side of the heart (i.e. lower half of the L-atrium, mitral valve, L-ventricle) is represented on the left side of the medulla oblongata, and the upper half of the left atrium is represented in the caudal end of the left side of the pons. The bottoms of the ventricles are located near the spinal cord. Furthermore, the right and the left sides of the heart are represented in specific areas of each side of the right and left hemispheres of the cerebral cortex, and there are connecting pathways between the representation areas of identical parts of the heart, through the corpus callosum and other neuro-pathways.

Central Nervous System

Myocardial imaging with radionuclide-labeled particles. Analysis of the normal image, abnormal image, and technical consideration.

Myocardial imaging following the direct injection of labeled particles is an effective and safe method of studying regional perfusion. Perfusion defects can conveniently be classified as apical, anterior, inferior, or posterior and related to the distribution of specific coronary arteries. The hemodynamic effects of contrast material, inadequate mixing of particles, coronary anatomy, and associated cardiac pathology are important technical considerations affecting the performance and interpretation of studies using this technique.

Albumins

Differential uptake and apparent 201Tl washout after thallium reinjection. Options regarding early redistribution imaging before reinjection or late redistribution imaging after reinjection.

BACKGROUND: Because thallium reinjection enhances the identification of viable myocardium, many laboratories have adopted the routine practice of performing reinjection imaging instead of 3-4-hour redistribution imaging. This approach assumes that the stress-reinjection protocol provides the necessary information regarding both exercise-induced ischemia and myocardial viability. Because apparent "washout" of thallium may occur between redistribution and reinjection studies, we examined the limitations created by eliminating 3-4-hour redistribution images. METHODS AND RESULTS: We studied 50 patients with chronic stable coronary artery disease by exercise thallium tomography, radionuclide angiography, and coronary arteriography. Immediately after the 3-4-hour redistribution images, 1 mCi thallium was injected at rest, and images were reacquired both 10 minutes and 24 hours after reinjection. The stress, redistribution, reinjection, and 24-hour images were then analyzed quantitatively, and the magnitude of change in regional thallium activity after reinjection was termed "differential uptake." Of the 127 abnormal myocardial regions on the stress images, 55 (43%) demonstrated either complete or partial reversibility on 3-4-hour redistribution images. After reinjection, 14 of these regions (25%) demonstrated apparent thallium washout due to low differential uptake of thallium, which was only 46 +/- 20% of that observed in normal regions. As a result, the relative thallium activity, which was 55 +/- 13% during stress (relative to normal regions) and increased significantly to 75 +/- 13% on 3-4-hour redistribution studies (p less than 0.001), decreased to only 58 +/- 13% after thallium reinjection. At 24 hours, redistribution again developed in all 14 regions, resulting in a relative thallium activity of 71 +/- 16% (p less than 0.03), which was similar to that achieved on 3-4-hour redistribution images. Twelve of the 14 regions (86%) exhibiting apparent washout after reinjection were supplied by a totally occluded coronary artery, of which eight (67%) had normal wall motion at rest. In contrast, only 41% of the regions with either improved or unchanged thallium uptake after reinjection were supplied by a totally occluded coronary artery (p less than 0.05). CONCLUSIONS: These data indicate that regions with thallium defects that are reversible on 3-4-hour redistribution images may demonstrate apparent washout of thallium after reinjection due to low differential uptake. Although this occurs in only a small fraction of regions (8%) identified as abnormal on exercise images, these regions represent approximately 25% of regions showing redistribution. Such defects would appear irreversible if redistribution imaging is not performed before reinjection. However, these same myocardial regions also redistribute further after reinjection and are identified as reversible on 24-hour images. Thus, one of two imaging options, either stress-redistribution-reinjection imaging or stress-reinjection-24-hour imaging, may be used for a comprehensive assessment of myocardial ischemia and viability.

Coronary Angiography

Thallium-201 for assessment of myocardial viability: quantitative comparison of 24-hour redistribution imaging with imaging after reinjection at rest.

Redistribution thallium-201 imaging 2 to 4 h after exercise may be incomplete and therefore may be inadequate to fully assess myocardial variability. Late redistribution imaging 24 h after exercise has been proposed to overcome this limitation of thallium stress imaging. However, because of poor count density the image quality on these studies is often suboptimal. In the present study the diagnostic information on 24-h planar thallium redistribution images was compared with that on images obtained after a reinjection of thallium at rest. Eighty-four patients with a stress thallium-201 defect had delayed redistribution imaging after 2 to 4 h and 24 h later, and again after an injection of thallium at rest. Defect reversibility on 24-h redistribution images was compared quantitatively with that on images after injection of thallium at rest. The quality of thallium images at rest was consistently better than that of 24-h redistribution images. Poor quality studies occurred in 13% of 24-h redistribution images compared with 0.4% of the studies at rest. Significantly more defect reversibility was detected on images after the reinjection at rest. Of 41 patients who appeared to have a fixed defect at 2- to 4-h redistribution imaging, 11 (27%) had a reversible defect by 24-h redistribution imaging compared with 29 (71%) after thallium-201 reinjection. No clinical variables at the time of stress testing were predictive of late defect reversibility. It is concluded that in patients with fixed a thallium defect at 2 to 4 h after exercise, reimaging after a reinjection at rest provides better diagnostic information than does 24-h late redistribution imaging.

Adult

MR imaging in the evaluation of benign uterine masses: value of gadopentetate dimeglumine-enhanced T1-weighted images.

Forty-six patients with surgically proved disease (115 leiomyomas, 19 cases of adenomyosis, and 14 endometrial polyps) were studied to determine if gadopentetate dimeglumine-enhanced T1-weighted MR images improve the detection and characterization of benign tumors of the uterus. Lesion detection and characterization were assessed separately for each sequence (unenhanced T1-weighted, proton-density-weighted, and T2-weighted and contrast-enhanced T1-weighted images) and for combinations of sequences (unenhanced T1- and T2-weighted images, unenhanced and contrast-enhanced T1-weighted images, and unenhanced T1- and T2-weighted and contrast-enhanced T1-weighted images). In the evaluation of leiomyomas, analysis of all three sequences provided the best detection (92%) and characterization (92%), but the improvement, except when compared with unenhanced T1-weighted images alone, was not statistically significant. The use of contrast medium did not contribute to either tumor detection or characterization. In the evaluation of adenomyosis, T2-weighted images provided significantly better lesion detection and characterization than did either unenhanced or contrast-enhanced T1-weighted images. In the evaluation of endometrial polyps, however, contrast-enhanced T1-weighted images provided significantly better lesion detection and characterization than did unenhanced images. With contrast-enhanced images, the detection rate was 79%, compared with 36% for T2-weighted images and 7% for T1-weighted images. Lesion characterization was the best (73%) when all imaging sequences were analyzed. Our study shows that with conventional spin-echo sequences, the use of contrast-enhanced T1-weighted images does not improve the detection or characterization of uterine leiomyomas or adenomyosis but significantly improves the detection of endometrial polyps.

Contrast Media

MR imaging of pelvic masses in women: contrast-enhanced vs unenhanced images.

OBJECTIVE: We compared the value of contrast-enhanced MR images with that of T2-weighted MR images in the diagnosis and staging of pelvic masses in women. MATERIALS AND METHODS: The findings on preoperative MR studies of 97 patients with a total of 124 surgically proved lesions were retrospectively analyzed. Unenhanced T1- and T2-weighted spin-echo images were compared with contrast-enhanced T1-weighted images. The final diagnosis included benign (36 patients), borderline (six patients), and malignant (15 patients) ovarian masses, fallopian tube masses (15 patients), endometrial tumors (seven patients), cervical carcinomas (32 patients), subserous leiomyomas (11 patients), and two masses of extragenital origin. RESULTS: In the depiction of pelvic lesions, the sensitivity of contrast-enhanced MR imaging (96%) was equal to that of unenhanced T2-weighted imaging (97%). Contrast-enhanced images were useful in the definition of intratumoral architecture and tumor borders of 72 adnexal masses, resulting in better determination of malignancy (accuracy, 95%) than on T2-weighted images (85%). Size of viable tumor, differentiation of tumor from retained fluid, and depth of myometrial invasion of six endometrial carcinomas were most reliably shown on contrast-enhanced images. In the evaluation of cervical carcinoma, overall staging accuracy of contrast-enhanced imaging (80%) was slightly inferior to that of T2-weighted imaging (83%). However, contrast-enhanced images improved assessment of parametrial and organ invasion in seven cases in which findings on T2-weighted MR images were equivocal. Administration of contrast material was not helpful in the evaluation of subserous leiomyomas or masses of extragenital origin. CONCLUSIONS: The findings suggest that when results of unenhanced T1- and T2-weighted MR imaging of pelvic masses are equivocal, contrast-enhanced MR images should be used as supportive and complementary pulse sequences to (1) improve definition of intratumoral architecture and prediction of malignancy in adnexal tumors, (2) stage endometrial carcinoma, and (3) determine tumor extension in cervical carcinoma.

Adult

Diagnostic value of gadopentetate dimeglumine for 1.5-T MR imaging of musculoskeletal masses: comparison with unenhanced T1- and T2-weighted imaging.

Three magnetic resonance (MR) imaging techniques (T1-weighted, T2-weighted, and T1-weighted gadopentetate dimeglumine--enhanced) were compared in 32 consecutive MR imaging studies of 26 patients with suspected musculoskeletal masses. T2-weighted images were superior to T1-weighted enhanced images with respect to detection and definition of lesions in 12% of cases (n = 4) and were equal in 88% of cases (n = 28). T2-weighted images were also superior to T1-weighted images in 38% of cases (n = 12). In no cases were T1-weighted enhanced images superior to T2-weighted images. In two cases, T1-weighted images were superior to both T1-weighted enhanced and T2-weighted images. The authors conclude that gadopentetate dimeglumine did not provide much value in lesion detection above that obtained with T2-weighted images. They also conclude that T1-weighted images were occasionally superior to T1-weighted enhanced images and T2-weighted images because of loss of definition between fat and lesion on the latter.

Adolescent

GRASE (gradient- and spin-echo) MR imaging: a new fast clinical imaging technique.

A novel technique of magnetic resonance (MR) imaging, which combines gradient-echo and spin-echo (GRASE) technique, accomplishes T2-weighted multisection imaging in drastically reduced imaging time, currently 24 times faster than spin-echo imaging. The GRASE technique maintains contrast mechanisms, high spatial resolution, and image quality of spin-echo imaging and is compatible with clinical whole-body MR systems without modification of gradient hardware. Image acquisition time is 18 seconds for 11 multisection body images (2,000/80 [repetition time msec/echo time msec]) and 36 seconds for 22 brain images (4,000/104). With a combination of multiple Hahn spin echoes and short gradient-echo trains, the GRASE technique overcomes several potential problems of echo-planar imaging, including large chemical shift, image distortions, and signal loss from field inhomogeneity. Advantages of GRASE over the RARE (rapid acquisition with relaxation enhancement) technique include faster acquisition times and lower deposition of radio-frequency power in the body. Breath holding during 18-second GRASE imaging of the upper abdomen eliminates respiratory-motion artifacts in T2-weighted images. A major improvement in T2-weighted abdominal imaging is suggested.

Abdomen

Thallium reinjection after stress-redistribution imaging. Does 24-hour delayed imaging after reinjection enhance detection of viable myocardium?

BACKGROUND: Thallium reinjection immediately after conventional stress-redistribution imaging improves the detection of viable myocardium, as many myocardial regions with apparently "irreversible" thallium defects on standard 3-4-hour redistribution images manifest enhanced thallium uptake after reinjection. Because the 10-minute period between reinjection and imaging may be too short, the present study was designed to determine whether 24-hour imaging after thallium reinjection provides additional information regarding myocardial viability beyond that obtained by imaging shortly after reinjection. METHODS AND RESULTS: We studied 50 patients with chronic stable coronary artery disease undergoing exercise thallium tomography, radionuclide angiography, and coronary arteriography. Immediately after the 3-4-hour redistribution images were obtained, 1 mCi thallium was injected at rest, and images were reacquired at 10 minutes and 24 hours after reinjection. The stress, redistribution, reinjection, and 24-hour images were then analyzed qualitatively and quantitatively. Of the 127 abnormal myocardial regions on the stress images, 55 had persistent defects on redistribution images by qualitative analysis, of which 25 (45%) demonstrated improved thallium uptake after reinjection. At the 24-hour study, 23 of the 25 regions (92%) with previously improved thallium uptake by reinjection showed no further improvement. Similarly, of the 30 regions determined to have irreversible defects after reinjection, 29 (97%) remained irreversible on 24-hour images. These findings were confirmed by the quantitative analysis. The mean normalized thallium activity in regions with enhanced thallium activity after reinjection increased from 57 +/- 13% on redistribution studies to 70 +/- 14% after reinjection but did not change at 24 hours (71 +/- 14%). In regions with irreversible defects that were unaltered by reinjection, mean regional thallium activity did not differ from the reinjection to the 24-hour studies (57 +/- 17% and 58 +/- 17%, respectively). Twenty-four-hour imaging after reinjection showed improvement in only four of 35 irreversible regions (involving three of the 50 patients). CONCLUSIONS: These data indicate that thallium reinjection at rest after 3-4 hours of redistribution provides most of the clinically relevant information pertaining to myocardial viability in regions with apparently irreversible thallium defects. Hence, thallium reinjection may be used instead of 24-hour imaging in most patients in whom a persistent thallium defect is observed on conventional redistribution images.

Coronary Angiography

[Clinical trial of 111In-antimyosin antibody imaging: (3) Comparison with 99mTc-pyrophosphate imaging].

Clinical value of 111In-antimyosin monoclonal antibody F ab (AM) was compared with 99mTc-pyrophosphate (PYP) in 13 patients with myocardial infarction and 3 patients with myocarditis. Following PYP injection, PYP imaging was performed 3 hours later. Immediately after PYP imaging, AM was administrated and AM images were obtained 48 hours later. Abnormal accumulation in the infarcted myocardium was observed in 11 patients (85%) on AM images but only in 3 patients (23%) on PYP images. All patients within 8 days after the onset of infarction showed abnormal uptake on both images. Of 5 patients with 1 to 2 weeks after the onset of infarction, abnormal uptake was observed in all of them on AM images but only in one of them on PYP imaging. Furthermore, of 6 patients with more than 2 weeks after the onset, AM imaging showed abnormal uptake in 4 (67%) but PYP imaging did not show abnormal uptake in any of them. Similarly. Of 3 patients with myocarditis, diffuse uptake in the myocardium ws observed in 2 of them on AM images but none of them showed abnormal uptake on PYP images. We conclude that AM imaging is a useful means for identifying not only acute stages but also subacute stages of myocardial necrosis where PYP imaging did not show any abnormality.

Adult

Optimization of signal-to-noise ratio in calculated T1 images derived from two spin-echo images.

A simplified model relating signal intensity in an MR image to spin-lattice relaxation time (T1), repetition time (TR), number of signal averages and the average tip angle (-alpha) of the protons within the slice has been developed. This model has been used to select the optimal repetition times of two spin-echo images for a fixed total imaging time to maximize signal to noise in calculated T1 images. Theoretical predictions of T1 are virtually identical to spectroscopically measured values, and the relative noise (delta T1) in T1 images calculated from two measured spin-echo images is in good agreement with the theoretically predicted values of delta T1/T1. This model predicts that: (a) for a T1 of approximately 500 ms, the least T1 image noise is obtained with one of the spin-echo images collected with a TR of 400-500 ms. The longer the TR of the other spin-echo image, the lower the T1 image noise, but past a TR of approximately 1400 ms, T1 image signal/noise is optimized for the same total imaging time by increasing the number of averages in the shorter TR spin-echo image rather than increasing the TR of the second spin-echo image. (b) The error is reduced and the optimum TR1 is reduced as -alpha is increased from 63 to 90 degrees. (c) For a range of T1, optimal selection of TR1 and TR2 based on an intermediate value of T1, results in relatively little increase over optimal values in delta T1/T1 for the entire T1 range.

Humans