Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “fitness factor”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

Correlations between workplace protection factors and fit factors for filtering facepieces in the welding workplace.

Workplace protection factor (WPF) means a measure of the actual protection of respirator provided in the workplace when correctly worn. While fit factor (FF) represents a quantitative measure of the fit of a particular respirator to an individual and it is determined in the laboratory. To evaluate the relationship between WPF and FF is very important since FF may or may not be taken advantage of estimating WPF. Outside and inside Fe concentrations for three brand N95 filtering facepieces were collected on 14 workers/three respirator combinations in the welding workplace. The WPF measurements on the samples of the three respirator brands worn by 14 workers were observed to range from 2.2 to 132.9 with a geometric mean of 15.9 and a geometric standard deviation of 2.63. Respirator performances as measured by the WPF differed significantly among different respirator brands (p<0.05). In this study, correlations were found between the WPF measurements and the FF data for all samples of the three respirators (R2=0.38). The percentage of Fe particles having a smaller fraction than 1.1 microm diameter was observed as 71.6% of the total.

Filtration↗

Variation in quantitative respirator fit factors due to fluctuations in leak size during fit testing.

Variation in fit factors during quantitative respirator fit testing was studied for a high degree of fit (aerosol fit factors > 1000) and a low degree of fit (aerosol fit factors < 1000). In a controlled human study, fit factors were determined sequentially for three different exercises by (1) an aerosol fit test (using a portable condensation nuclei counter and room aerosol as the test agent) and (2) the newly developed dichotomous-flow fit test (Dichot). For the higher level of respirator fit, the aerosol fit factors were 30 to 60 times the corresponding flow fit factors, and for the lower level of respirator fit they were 2 to 4 times the flow fit factors. A coefficient of variation (CV) of 84% (GSD 1.6) for the higher respirator fit and 178% (GSD 2.2) for the lower respirator fit data was observed in the human study when aerosol fit factors for the three exercises were pooled. In a similar mannequin study, the center sampling probe gave aerosol fit factors with a CV of 5.4% (GSD 1.05). The flow fit factors for all three exercises pooled had a CV of 36% (GSD 1.3) for the higher respirator fit and 40% (GSD 1.5) for the lower respirator fit data, while the mannequin study gave flow fit factors with a CV of 2.2% (GSD 1.02). Thus, the variation in fit factors obtained in the human study was much higher than that obtained in a mannequin study. However, the variation in the aerosol method relative to the flow method, in the human study, os of the same order of magnitude as in the mannequin study.(ABSTRACT TRUNCATED AT 250 WORDS)

Air↗

Fit factors for quarter masks and facial size categories.

Respirator fit testing is necessary before entering hazardous working environments to ensure that the respirator, when worn, satisfies a minimum fit and that the wearer knows when the respirator fits properly. In the many countries that do not have fit testing or total inward leakage regulations (including Korea), however, many workers wearing respirators may be potentially exposed to hazardous environments. It is necessary to suggest a useful tool to provide an alternative for fit testing in these countries. This study was conducted to evaluate fitting performance for quarter-mask respirators, and fit factors in facial size categories based on face lengths and lip lengths of the wearers. A total of 778 subjects (408 males, 370 females) were fit tested for three quarter masks: Sejin Co. SK-6 (Ulsan, Korea), Yongsung Co. YS-2010 S (Seoul, Korea), and 3 M Co. Series 7500 Medium (MN, USA) masks with a PortaCount 8020 (TSI Co., USA). A facial dimension survey of the subjects was conducted to develop facial size categories, on the basis of face length and lip length. Geometric mean fit factors (GMFFs) of Series 7500 Medium were found to be the highest of the three respirators. All of the respirators were more suitable for males than females in fitting performance. The Series 7500 Medium fitted a large number of the males tested, since the GMFFs for males were above 100 for every box of facial size categories, and high pass proportion rates were shown at an individual fit factor level of 100. The YS-2010 S provides an adequate fit for males in a limited range of facial dimensions. The Series 7500 Medium is more limited in providing adequate fit for females at specific facial dimensions than for males. For adequate fitting performance, the SK-6 is not preferentially recommended for Korean male and female workers due to low GMFFs and pass proportions. The result of this study indicates that after more accurate studies are performed, facial size categories, on the basis of facial dimensions, could be a useful tool to assist in the selection of adequately fitting respirators for workers in the countries having no fit testing requirements.

Adult↗

Correlation between quantitative fit factors and workplace protection factors measured in actual workplace environments at a steel foundry.

Past studies have found little or no correlation between workplace protection factors (WPFs) and quantitative fit factors (FFs). This study investigated the effect of good- and poor-fitting half-facepiece, air-purifying respirators on protection in actual workplace environments at a steel foundry and the correlation between WPFs and FFs. Fifteen burners and welders, who wore respirators voluntarily, and chippers participated in this study. Each subject was fit-tested with two respirator models each with three sizes, for a total of six fit-tests. Models and sizes were assigned this way to provide a wide range of FFs among study participants. Each worker donned the respirator twice per day (at the beginning of the shift and following the lunch break) for 2 days. Quantitative FFs were first obtained for each donning using the PortaCount Plus trade mark in a separate room. Without redonning the respirators, workers performed normal work for 1 to 2 hours, and WPFs were measured by collecting ambient and in-facepiece samples simultaneously. A second fit-test was conducted without disturbing the respirator. FFs were obtained by averaging the results from the first and second fit-tests. The resulting FFs had a geometric mean (GM) of 400 (range=10-6010) and a geometric standard deviation (GSD) of 6.1. Of the 55 valid donnings, 43 were good fitting (FFs> or =100) and 12 were poor fitting (FFs<100). The WPFs had a GM of 920 (range=13-230,000) and a GSD of 17.8. The WPFs were found to be significantly correlated with the FFs (R(2)=.55 and p-value=.0001). Therefore, FF was shown to be a meaningful indicator of respirator performance in actual workplace environments.

Adult↗

Respirator fit factor performance while sweating.

The extent to which sweat accumulation inside respirators affects respirator fit has not been quantified. This study represents an attempt to measure facial sweating and to quantify its effects on fit factors of negative pressure, full-facepiece respirators. Respirator fit factor (FF) data were obtained while 14 subjects completed 30 minutes of treadmill walking at an intensity of 75% of age-predicted maximal heart rate in an aerosol test chamber under ambient environmental conditions. Subject facial and whole body sweat production were also measured. Statistical analysis of the treadmill FF results showed that respirator fit was significantly (p < 0.05) degraded after 14 minutes of exercise. Sweat accumulation inside the respirator facepiece averaged 30.9 +/- 15.5 g. However, no significant correlation of subject facial sweat production with overall FF values measured during exercise was found. The results of this study indicate that respirator FFs degrade significantly over time under moderate exercise and environmental conditions and suggest that facial sweat accumulation alone does not account for the reduced FF levels.

Adult↗

The effects of strapped spectacles on the fit factors of three manufactured brands of full facepiece negative pressure respirators.

A study was conducted to determine the effects of strapped spectacles on the fit factors obtained during quantitative fit testing on three different brands of full facepiece negative pressure respirators. The three brands of respirators were evaluated with and without strapped spectacles worn by the test subjects. A total of 180 quantitative fit testing trials were conducted on ten male test subjects. For each test subject, three quantitative fit testing trials were performed with each brand of respirator with and without the spectacles. The average of the fit testing trials for each subject with each respirator was used for statistical analysis. The results demonstrated that the fit factor values were significantly lower during use of the spectacles (p < 0.05). The estimated percentage of test subjects who failed the American National Standards Institute pass/fail criteria for quantitative fit testing (1000) increased by 15-36% when spectacles were worn.

Adolescent↗

Formulation optimization of controlled-release pellets of metoclopramide hydrochloride using dissolution fit factor approach.

The purpose of this study was to optimize the formulation variables for the preparation of ethyl cellulose-coated nonpareils loaded with metoclopramide hydrochloride (MCL). The approach to evaluate the effectiveness of formulation parameters was monitored by release rate testing using dissolution fit factors as a tool. The content of ethyl cellulose used in the formulation was based on the drug-loaded weight. The interrelationship of each developed formulation and the reference formulation Gastro-Timelets and their respective dissolution curves were evaluated using Moore's equation: [equation: see text]. The relationship between the ethyl cellulose content in the formulation and the dissolution fit factor f2 can be described as the following regression equation: Y = -0.054X2 + 3.347X - 1.915 (r2 = 0.99). The optimum ethyl cellulose content obtained from the equation was 30.8%. The type and content of plasticizer used in the formulation to achieve the greatest f2 were determined to be Myvacet 9-40 at the concentration of 25%. Results indicated that using the release rate testing approach with the dissolution fit factor as a tool could provide valuable information for formulation optimization.

Cellulose↗

An evaluation of fit factors and dissolution efficiency for the comparison of in vitro dissolution profiles.

Dissolution efficiency (D.E.), the area under a dissolution curve between defined time points, and the fit factors (f1 and f2) have been compared for the characterisation of dissolution profiles, using data from three batches of a product in nine different packs stored under two conditions. The factors f1 and f2 offer ease of calculation and a simple measure of similarity between pairs of dissolution profiles. This is well suited to the qualitative determination of 'similarity' as required by the FDA's SUPAC Guide. However, they do not provide information on individual batches, including their consistency. In contrast, D.E. does provide such information is well-suited to making quantitative comparisons amongst batches. Because D.E. has a simple physical meaning, it is easier to interpret D.E. data then corresponding f1 and f2 results. The confidence limits in D.E. values provide a useful measure of the variability in batch dissolution and allow the statistical significance of difference in D.E. between pairs of batches to be determined. Both of the above measures lead to the same conclusions regarding the similarity in protective power amongst the nine packs under test and to the value of added desiccant in maintaining the dissolution profile of the product when stored under high humidity conditions. It is concluded that D.E. offers a suitable alternative to the single point dissolution measurement for QC of immediate release products.

Models, Chemical↗

Comparison of simulated respirator fit factors using aerosol and vapor challenges.

Although not well established, mask leakage measured using submicron aerosol challenges is generally accepted as being representative of vapor challenges. The purpose of this study was to compare simulated respirator fit factors (FFs) measured using vapor challenges to those measured using an aerosol challenge. A full-facepiece respirator was mounted on a headform inside a small enclosure and modified with controlled leaks (laser-drilled orifices) to produce FFs ranging from about 300 to 30,000. A breathing machine was used to simulate breathing conditions of 1.0 L tidal volume and 25 breaths/min. A monodisperse aerosol consisting of 0.72 micron polystyrene latex spheres (PSL) was used for the reference test aerosol, and FFs were measured using a laser aerosol spectrometer. An inert gas, sulfur hexafluoride (SF6), and an organic vapor, isoamyl acetate (IAA), were used as the vapor challenges. The in-mask concentration of SF6 was measured using a gas chromatograph (GC). A GC was also used to quantify in-mask IAA concentration samples actively collected with sorbent tubes. FF measurements made with the PSL aerosol challenge were conducted in sequence with the SF6 and IAA challenges, without disturbing the mask, to yield matched data pairs for regression analysis. FFs measured using the PSL reference aerosol were found to correlate well with those measured with the SF6 (r2 = 0.99) and IAA (r2 = 0.98) vapor challenges. FFs measured using IAA tended to be higher at values below 10,000. The best agreement was observed with the inert gas, SF6. The results of this study suggest that submicron aerosols are suitable as quantitative fit test challenges for assessing the performance of respirators against inert vapors.

Aerosols↗

Cerato-ulmin, a hydrophobin secreted by the causal agents of Dutch elm disease, is a parasitic fitness factor.

Dutch elm disease is caused by the aggressive Ophiostoma novo-ulmi and the nonaggressive O. ulmi. Both secrete the protein cerato-ulmin (CU). To determine what role CU plays in the pathology of Dutch elm disease, we constructed a CU overexpression mutant of the nonaggressive O. ulmi H5. Stable integration of a single copy of the cu gene from the aggressive O. novo-ulmi into the genome of the nonaggressive isolate resulted in increased secretion of CU protein. Trials with American elm, Ulmus americana, suggested no alteration of virulence of this overexpressing transformant. Using aggressive and nonaggressive wild types, the cu overexpressing mutant, and our cu- mutant (Bowden et al., 1996), we have demonstrated that CU production is correlated with an altered phenotype and more hydrophobic and adherent yeast-like cells. Our results also demonstrate that CU has a role in protecting infectious propagules from desiccation. These biological roles for CU would affect transmission of Dutch elm disease, and we therefore propose that this hydrophobin acts as a parasitic fitness factor.

Cell Adhesion↗

Use of analgesics in Sweden--the importance of sociodemographic factors, physical fitness, health and health-related factors, and working conditions.

In this study, factors related to analgesic use-independent of their association with pain-were studied in the general Swedish population. These included sociodemographics, health and health-related factors, physical fitness and working conditions. Data from the Swedish Survey of Living Conditions for the two-year period 1988/89 were used. In this survey a random sample (n = 13,295, response rate 79.4%) of the Swedish population aged 16 years and older was interviewed about health, medication use and related matters, among other things. In all, 35% of the population used analgesics at least once during a two-week period, and analgesic use was more than 50% higher among women than men. Analgesic use was less common among those aged 45-64 years and 65-74 years than those 18-44, after controlling for all other variables. The study showed that self-perceived poor health and pain explain much analgesic use. Analgesic use is further explained by lifestyle, sleeping problems, and health care utilization. Marital status, educational level, socioeconomic status, social network and working conditions were found to be of minor importance.

Adolescent↗

Evaluation of a quantitative fit testing method for N95 filtering facepiece respirators.

A method for performing quantitative fit tests (QNFT) with N95 filtering facepiece respirators was developed by earlier investigators. The method employs a simple clamping device to allow the penetration of submicron aerosols through N95 filter media to be measured. The measured value is subtracted from total penetration, with the assumption that the remaining penetration represents faceseal leakage. The developers have used the clamp to assess respirator performance. This study evaluated the clamp's ability to measure filter penetration and determine fit factors. In Phase 1, subjects were quantitatively fit-tested with elastomeric half-facepiece respirators using both generated and ambient aerosols. QNFT were done with each aerosol with both P100 and N95 filters without disturbing the facepiece. In Phase 2 of the study elastomeric half facepieces were sealed to subjects' faces to eliminate faceseal leakage. Ambient aerosol QNFT were performed with P100 and N95 filters without disturbing the facepiece. In both phases the clamp was used to measure N95 filter penetration, which was then subtracted from total penetration for the N95 QNFT. It was hypothesized that N95 fit factors corrected for filter penetration would equal the P100 fit factors. Mean corrected N95 fit factors were significantly different from the P100 fit factors in each phase of the study. In addition, there was essentially no correlation between corrected N95 fit factors and P100 fit factors. It was concluded that the clamp method should not be used to fit-test N95 filtering facepieces or otherwise assess respirator performance.

Adult↗

Capability of respirator wearers to detect aerosolized qualitative fit test agents (sweetener and Bitrex) with known fixed leaks.

This study was designed to evaluate and compare the ability of respirator wearers to detect qualitative respirator fit test agents (saccharin and Bitrex) when the respirators were modified to include fixed size leaks. In recent years the number of persons who require fit testing has increased, partly in response to the needs of health care workers with potential exposure to infectious bio-aerosols. Many health care providers have chosen qualitative respirator fit testing using saccharin and/or Bitrex for a variety of reasons, including (but not limited to) low initial equipment cost. Respirators were modified to include a mid-line sampling probe between the nose and mouth for quantitative fit testing with a TSI PortaCount. A second modification included the introduction of a shortened 14-gauge intravenous catheter at the bridge of the nose. The fixed leak was designed to produce fit factors < 100 when unplugged, with an average fit factor of 67 among 26 respirator wearers. A complete fit test was not performed, because one purpose of this study was to determine the ability of respirator wearers to detect a known fixed leak during a single normal breathing exercise, without introducing unknown and potentially variable size leaks. Sensitivity threshold screening included a placebo and requirement to correctly characterize the taste of the agent used. Quantitative fit factors without leaks ranged from 96 to > 20,000 and 22 to 160 with the leak present. Twenty four of 26 subjects had fit factors < 100 (92%) when fixed leaks were induced. All subjects correctly detected Bitrex with fixed leaks (sensitivity = 100%). Nine of 26 subjects (35%) were unable to detect saccharin in the presence of a known fixed leak even though the average fit factor for these subjects was 77. When the two subjects with fit factors > 100 were excluded, only 16 of 24 respirator wearers were able to detect saccharin with fixed leaks (sensitivity = 67%). There were several important aspects of our study design worth noting, including the introduction of a placebo during sensitivity threshold testing, limiting the subject response time to a single maneuver, using a higher concentration of Bitrex than commercially available, and requiring the subjects to correctly characterize the taste of the qualitative test agent. In conclusion, leak detection was correctly identified with Bitrex, but not saccharin.

Adolescent↗

Effect of facial hair on the face seal of negative-pressure respirators.

The effect of facial hair on the face seal of negative-pressure respirators, both half-masks and full facepieces, has been investigated. Three hundred and seventy (370) male employees were fit tested both qualitatively and quantitatively. Of these, sixty-seven (67) had fully established beards varying in length, shape, density and texture. Bearded subjects consistently failed the qualitative fit test protocol. Quantitative fit testing with half-mask respirators indicated that bearded employees had a median fit factor of 12 (8% leakage). A median fit factor of 2950 (0.03% leakage) was obtained on clean-shaven employees. An average two hundred and forty-six (246) fold drop in protection was experienced by bearded employees. With full facepiece respirators, the bearded employees had a median fit factor of 30 (3% leakage). A median fit factor of greater than 10 000 (less than 0.01% leakage) was obtained on clean-shaven employees. At least a three hundred and thirty (330) fold drop in protection was experienced by bearded employees. Results indicate that the presence of a beard greatly increases the leakage through the respirator face seal, and this leakage should not be permitted when employees are required to wear respirators.

Face↗

Factors affecting abundance of Triaenophorus infection in Cyclops strenuus, and parasite-induced changes in host fitness.

Factors affecting the abundance of Triaenophorus crassus and Triaenophorus nodulosus procercoids in their copepod first intermediate host, Cyclops strenuus, and effects of infection on feeding behaviour, reproduction and survival of the host were studied experimentally. When exposed to the same number of coracidia, copepods harboured considerably less procercoids in the trials where ciliates or Artemia salina nauplii were given as alternative food items. The prevalence of infection was higher in adult copepods as compared with copepodite stage IV and stage V, and higher in stage V than in stage IV. The prevalences in adult females and males did not differ significantly from each other. The frequency of females carrying egg sacs was lower among infected than among exposed uninfected and unexposed copepods. The rate of feeding on Artemia nauplii remained at the same level in uninfected copepods, but decreased strongly in infected copepods during 7 days p.i. The survival of unexposed, exposed uninfected and infected copepods did not differ significantly from each other for the first 11 days post-exposure, but the mortality of infected copepods increased significantly after 3 weeks post-exposure. However, the rate of development and mortality of copepods might have been affected by the apparently arrested development of stage IV copepodites found in the experiment. Some of the contradictions between these results and earlier observations are suggested to be caused by the differences in the duration of exposure, intensity of infection and duration of observation post-exposure in the present study as compared with other experiments.

Animals↗

Workplace protection factor measurements on powered air-purifying respirators at a secondary lead smelter: results and discussion.

A study was conducted at a secondary lead smelter to evaluate the workplace performance of the 3M W-344 and Racal AH3 powered air-purifying respirators equipped with helmets and high efficiency filters. The research protocol developed for the study has been described in a companion paper. The results of the study indicate that the mean lead concentrations, measured inside the facepiece of both PAPRs, were significantly less than the OSHA lead exposure limit of 50 micrograms/m3. The means of the workplace protection factor measurements on both PAPRs were significantly less than the PAPR selection guide protection factor classification of 1000. Correlation analysis of preshift quantitative fit factors and corresponding workplace protection factors indicated no linear association between these two measures of performance. This finding suggests that for PAPRs equipped with helmets and high efficiency filters quantitative fit factors as presently determined are not indicative of the workplace protection which the respirators provide. Since the PAPR protection factor classification of 1000 was originally based on quantitative fit factors, the lack of a demonstrated association between quantitative fit factors and workplace protection as found in this study may explain why their performance was significantly less than expected.

Air Pollutants, Occupational↗

Fitting the factor analysis model in lI norm.

The well-known problem of fitting the exploratory factor analysis model is reconsidered where the usual least squares goodness-of-fit function is replaced by a more resistant discrepancy measure, based on a smooth approximation of the lI norm. Fitting the factor analysis model to the sample correlation matrix is a complex matrix optimization problem which requires the structure preservation of the unknown parameters (e.g. positive definiteness). The projected gradient approach is a natural way of solving such data matching problems as especially designed to follow the geometry of the model parameters. Two reparameterizations of the factor analysis model are considered. The approach leads to globally convergent procedures for simultaneous estimation of the factor analysis matrix parameters. Numerical examples illustrate the algorithms and factor analysis solutions.

Algorithms↗