Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “computed tomography imaging”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

Digiplot: a PC programme for drawing tumour volumes for radiation therapy treatment planning using computed tomography images.

Computed tomography (CT) provides explicit information for tumour localisation. However, CT data are displayed in the transverse plane, whereas on the Radiotherapy Simulation films, radiation portals are commonly directed into anteroposterior and lateral planes. Using present day radiotherapy planning computers, it is possible to read in the CT data to determine the tumour volume in anterior/posterior and lateral directions and to perform dosimetry calculations. In cases where the digital computer data cannot be used directly by the radiotherapy planning computer, (for example, owing to compatibility problems) the radiation oncologist must transfer information about tumour location from the CT hard copy images to the longitudinal planes of the simulation film by hand. This manual data transfer can now also be performed using the new personal computer programme, Digiplot, which we have developed and is described below. The application of Digiplot to the head and neck area has shown that it complies with the accuracy requirements laid down by the radiation oncologist. The clinical impact of Digiplot was tested on ten patients with a brain tumour. In two cases, Digiplot detected errors which had not been observed using the conservative (manual) method.

Humans↗

Detection of hepatocellular carcinoma: comparison of dynamic three-phase computed tomography images and four-phase computed tomography images using multidetector row helical computed tomography.

PURPOSE: The purpose of our study was to assess the value of additional early arterial phase computed tomography (CT) imaging in the detection of hepatocellular carcinoma (HCC) by comparing three-phase and four-phase imaging by using multidetector row helical CT. METHODS: Twenty-five patients with 33 HCCs underwent four-phase helical CT imaging. The diagnosis was established by pathologic examination after surgical resection in 19 patients and by biopsy in six. Four-phase CT imaging comprises early arterial, late arterial, portal venous, and delayed phase imaging obtained 25 seconds, 45 seconds, 75 seconds, and 180 seconds after the start of contrast material injection using multidetector row helical CT. Three-phase CT images (late arterial, portal venous, and delayed phase) and four-phase CT images (early arterial, late arterial, portal venous, and delayed phase) were interpreted independently for the detection of HCC by three blinded observers on a segment-by-segment basis. Sensitivity, specificity, and area under the receiver operating characteristic (ROC) curve (Az) for three-phase CT images and four-phase CT images were calculated. The enhancement pattern of HCC was analyzed on early arterial and late arterial phase imaging. RESULTS: The mean sensitivity of three- and four-phase CT images was 94% and 93%, respectively. The differences between sensitivities were not statistically significant (all p > 0.05). The mean specificities of three- and four-phase CT images were 99% and 98%, respectively. The differences between the specificities were not statistically significantly (all p > 0.05). Neither were the mean areas under the ROC curve for four-phase CT images (Az = 0.976) and three-phase CT images (Az = 0.971) statistically significant (p > 0.05). On early arterial phase imaging, 16 HCCs were hyperattenuating and 17 HCCs were isoattenuating. On late arterial phase imaging, 24 HCCs were hyperattenuating and nine HCCs were isoattenuating. CONCLUSIONS: Additional early arterial phase imaging did not improve the detection of HCC compared with three-phase CT images, including late arterial, portal venous, and delayed phase imaging.

Adult↗

I-131 anti-B1 therapy/tracer uptake ratio using a new procedure for fusion of tracer images to computed tomography images.

In patients with non-Hodgkin's lymphoma being treated by I-131-radiolabeled anti-B1 monoclonal antibody, we test the hypothesis that the activity taken up in tumors during therapy is the same as that observed during tracer evaluation, except for scaling by the ratio of administered activities. Chemotherapy-relapsed patients are imaged only with planar conjugate views, whereas previously untreated patients are imaged with planar conjugate views and with single-photon emission computed tomography (SPECT). The SPECT tracer activity quantification requires computed tomography (CT) to SPECT image fusion, for which we devised a new procedure: first, the tracer SPECT images are fused to the therapy SPECT images. Then, that transformation is combined with the therapy SPECT-to-CT transformation. We also use (a) the same volumes of interest defined on CT for both tracer and therapy image sets, and (b) a SPECT counts-to-activity conversion factor that adapts to background and rotation radius. We define R as the ratio of therapy activity percentage of infused dose over tracer activity percentage of infused dose at 2-3 days after monoclonal antibody infusion. For 31 chemotherapy-relapsed patients, the R ratio for 60 solitary or composite tumors averages 0.931 +/- 0.031. The hypothesis of R being 1 is rejected with greater than 95% confidence. However, the difference from 1 is only 7.4%. The range of R is 0.43-1.55. For seven previously untreated patients, R averages 1.050 +/- 0.050 for 24 solitary tumors evaluated by SPECT. For six of these patients, R averages 0.946 +/- 0.098 for one of these solitary tumors and for five composite tumors, evaluated by conjugate views. Both results agree with the hypothesis that R is 1. The range of R for the SPECT tumors is 0.71 +/- 0.03 to 1.82 +/- 0.53, and for the conjugate view tumors, it is 0.70-1.35. Plots of R versus tumor volume yield small correlation coefficients. That from SPECT approaches a statistically significant difference from zero correlation (P = 0.06). In summary, on average, the tumor percentage of infused dose following tracer administration is predictive of therapeutic percentage of infused dose within 8%. For greater accuracy with individual tumors, however, an intratherapy evaluation is probably necessary because the range of R is large.

Antibodies, Monoclonal↗

The reliability of imaging (computed tomography, magnetic resonance imaging, myelography) in documenting the cause of spinal pain.

Computed tomography, magnetic resonance imaging and myelography have all been utilized in diagnosing the various causes of low back pain. Each procedure has certain strengths and weaknesses. This article discusses the reliability of each procedure. The article concludes by noting that each procedure should be used to confirm the clinical impression derived from the physical examination.

Back Pain↗

In vivo assessment of trabecular bone structure at the distal radius from high-resolution computed tomography images.

A dedicated computed tomography system was used to acquire transaxial images of the distal radius to assess trabecular bone structure in vivo. We segmented trabecular bone from the marrow and soft tissue background by postprocessing the image with a region grow and skeletonization step. From the processed image we assessed the integrity of the bone by examining the continuity of its trabecular network and by determining the area of the holes comprising its marrow space. The continuity of the bone imaged was assessed by a proposed connectivity index (CI) and the size of the marrow spaces was assessed by calculating a mean hole area (H(A)) in the bone cross-section. Repeat measurements revealed that the intra-subject variability in CI and H(A) was small (CV < 6%). Both CI and H(A) were sensitive enough to reflect differences in structure at the head of the radius and at several sites along its shaft. We tested the diagnostic value of assessing bone structure at the distal end of the radius by measuring trabecular bone density, CI and H(A) in a mixed group of 26 subjects, nine of whom had suffered a wrist fracture. We found that a trabecular bone density threshold of 116 mg cm-3, corresponding to two standard deviations below the mean density in the 17 non-fractured subjects, separated fractured from non-fractured subjects with a sensitivity of 22% and a specificity of 100%. A CI threshold of -4.7 doubled the sensitivity (44%) and maintained the 100% specificity. An H(A) threshold of 4.5 mm2 achieved a sensitivity of 89% and a specificity of 94%. This increased sensitivity achieved by our indices suggests that an in vivo assessment of trabecular bone structure can contribute significantly to the identification of persons at risk of fracture.

Adult↗

Information and artifact in computed tomography image statistics.

In conventional computed tomography images only the average CT number, which is a first-order statistical parameter, is used to characterize the tissues by giving an estimate of tissue density. Second order statistical parameters such as the signal variance and cross-correlation function have also been used to obtain additional information to discriminate between certain tissues and lesions. However, the contribution of quantum noise to the signal variance and cross-correlation function creates, for the conventional CT patient dose, a background signal often larger than the signal containing the information about tissue structure. The misleading information, called "artifacts", in second-order image statistics caused by quantum noise, is studied.

Information Theory↗

Detection of central pulmonary embolism on computed tomography densitometry images before computed tomography pulmonary angiography.

OBJECTIVE: The purpose of this article is to describe the imaging findings of acute central pulmonary embolism on computed tomography (CT) densitometry images performed before contrast-enhanced CT pulmonary angiography. METHODS: A retrospective review was conducted of reports from all CT pulmonary angiograms performed at our institution, and cases of acute central pulmonary embolism, defined as those with clot in the main, left, or right pulmonary arteries, were identified. Images of positive studies were reviewed on a picture archiving and communications system (PACS) workstation. RESULTS: A total of 1282 CT pulmonary angiograms were obtained for evaluation of possible acute pulmonary embolism, and 1 combined CT aortogram and pulmonary angiogram was performed for aortic dissection and acute pulmonary embolism. Two hundred fourteen (16.7%) examinations positive for acute pulmonary embolism were identified, 26 (12.1%, 2.0% of total examinations) of which had central clots. Of the 26 patients with central acute pulmonary embolism, 12 (46.1%, 5.6% of all positive studies and 0.9% of all CT pulmonary angiograms) had clots that were visible on the densitometry images. CONCLUSION: Although an uncommon finding, acute central pulmonary embolism can be detected on CT densitometry performed to optimize opacification of the pulmonary arteries for CT pulmonary angiography and may prove useful in selected clinical situations.

Acute Disease↗

Histogram-based selective deblurring to improve computed tomography imaging of calcifications.

OBJECTIVES: Computed tomography (CT) imaging of small high-density structures, eg, calcifications, is hampered by image blur. This study aims to deconvolve calcifications in the transverse and longitudinal directions while avoiding noise amplification and edge-ringing artifacts in the surrounding low-density structures. MATERIALS AND METHODS: A method referred to as histogram-based selective deblurring (HiSD) has been developed to generate a restored image by combining the low-intensity (ie, Hounsfield Units) information of the original image with the high-intensity information of the deconvolved image. HiSD is evaluated on phantom and in vitro atherosclerotic plaque CT images by comparing the original and restored images with their corresponding reference micro-CT images both qualitatively and quantitatively. RESULTS: HiSD reduces calcification blur in the transverse and longitudinal directions without introducing noise and ringing-artifacts in the surrounding tissues. Calcification area and volume measurements are significantly improved in the restored images (reducing on average overestimation by 32% and 83%, respectively). CONCLUSIONS: HiSD significantly improves CT visualization and quantification of small high-density structures imaged in vitro.

Algorithms↗

Iterative three-dimensional expectation maximization restoration of single photon emission computed tomography images: application in striatal imaging.

Single photon emission computed tomography imaging suffers from poor spatial resolution and high statistical noise. Consequently, the contrast of small structures is reduced, the visual detection of defects is limited and precise quantification is difficult. To improve the contrast, it is possible to include the spatially variant point spread function of the detection system into the iterative reconstruction algorithm. This kind of method is well known to be effective, but time consuming. We have developed a faster method to account for the spatial resolution loss in three dimensions, based on a postreconstruction restoration method. The method uses two steps. First, a noncorrected iterative ordered subsets expectation maximization (OSEM) reconstruction is performed and, in the second step, a three-dimensional (3D) iterative maximum likelihood expectation maximization (ML-EM) a posteriori spatial restoration of the reconstructed volume is done. In this paper, we compare to the standard OSEM-3D method, in three studies (two in simulation and one from experimental data). In the two first studies, contrast, noise, and visual detection of defects are studied. In the third study, a quantitative analysis is performed from data obtained with an anthropomorphic striatal phantom filled with 123-I. From the simulations, we demonstrate that contrast as a function of noise and lesion detectability are very similar for both OSEM-3D and OSEM-R methods. In the experimental study, we obtained very similar values of activity-quantification ratios for different regions in the brain. The advantage of OSEM-R compared to OSEM-3D is a substantial gain of processing time. This gain depends on several factors. In a typical situation, for a 128 x 128 acquisition of 120 projections, OSEM-R is 13 or 25 times faster than OSEM-3D, depending on the calculation method used in the iterative restoration. In this paper, the OSEM-R method is tested with the approximation of depth independent resolution. For the striatum this approximation is appropriate, but for other clinical situations we will need to include a spatially varying response. Such a response is already included in OSEM-3D.

Algorithms↗

Estimation of the heart respiratory motion with applications for cone beam computed tomography imaging: a simulation study.

Computed tomography (CT) reconstruction methods assume imaging of static objects; object movement during projection data acquisition causes tomogram artifacts. The continuously moving heart, therefore, represents a complicated imaging case. The associated problems due to the heart beating can be overcome either by using very short projection acquisition times, during which the heart may be considered static, or by ECG-gated acquisition. In the latter case, however, the acquisition of a large number of projections may not be completed in a single breath hold, thus heart displacement occurs as an additional problem. This problem has been addressed by applying heart motion models in various respiratory motion compensation algorithms. Our paper focuses on cone beam computed tomography (CBCT), performed in conjunction with isocentric, fluoroscopic equipment, and continuous ECG and respiratory monitoring. Such equipment is used primarily for in-theater three-dimensional (3-D) imaging and benefits particularly from the recent developments in flat panel detector technologies. The objectives of this paper are: i) to develop a model for the motion of the heart due to respiration during the respiratory cycle; ii) to apply this model to the tomographic reconstruction algorithm, in order to account for heart movement due to respiration in the reconstruction; and iii) to initially evaluate this method by means of simulation studies. Based on simulation studies, we were able to demonstrate that heart displacement due to respiration can be estimated from the same projection data, required for a CBCT reconstruction. Our paper includes semiautomatic segmentation of the heart on the X-ray projections and reconstruction of a convex 3-D-heart object that performs the same motion as the heart during respiration, and use of this information into the CBCT reconstruction algorithm. The results reveal significant image quality improvements in cardiac image reconstruction.

Algorithms↗

Single-photon emission computed tomography gallium imaging versus computed tomography: predictive value in patients undergoing high-dose chemotherapy and autologous stem-cell transplantation for non-Hodgkin's lymphoma.

PURPOSE: To evaluate the predictive value of computed tomography (CT) scanning and single-photon emission computed tomography (SPECT) gallium (Ga) scanning in the disease-free survival of patients receiving high-dose chemotherapy and autologous stem-cell transplantation for non-Hodgkin's lymphoma (NHL). PATIENTS AND METHODS: One hundred forty-three patients undergoing transplant for NHL underwent CT scanning of chest, abdomen, and pelvis, and a SPECT Ga scan before transplantation and at day + 100 after transplant. The failure-free survival (FFS) by scan result was analyzed. RESULTS: In the diffuse aggressive lymphoma patients, the 1-year FFS for patients having a positive SPECT Ga scan at day + 100 was 15% compared with a 3-year FFS of 47% for those with a negative scan (P < .001). Patients with a positive CT scan at day + 100 had a 36% 3-year FFS, and those with a negative CT scan had a 39% 3-year FFS (P = not significant [NS]). An analysis of the combination of CT scan and SPECT Ga scan results at day + 100 posttransplant demonstrated a 3-year FFS of 14% if they were both abnormal; if the CT was positive and Ga was negative, the 3-year FFS was 68%; positive Ga with a negative CT was 25%; and both negative was 34% (P = .0015). For the patients with follicular NHL, those with a positive SPECT Ga at day + 100 had a 14% 1-year FFS compared with those with a negative scan, who had a 45% 3-year FFS (P < .001). In the follicular NHL patients, the 3-year FFS of those with a positive CT was 17% compared with a 64% 3-year FFS for patients with a negative CT scan (P < .001). CONCLUSION: The use of SPECT Ga scan at day + 100 posttransplant for evaluation of disease activity in patients with diffuse aggressive NHL was highly predictive of eventual outcome and was more predictive than the CT scan results. However, for patients with follicular NHL, the addition of SPECT Ga scanning to CT scanning did not add substantially to the evaluation of transplant outcome.

Adolescent↗

Diagnosis of hepatic tumors with texture analysis in nonenhanced computed tomography images.

RATIONALE AND OBJECTIVES: Computed tomography (CT) after iodinated contrast agent injection is highly accurate for diagnosis of hepatic tumors. However, iodinating may have problems of renal toxicity and allergic reaction. We aimed to evaluate the potential role of the computer-aided diagnosis (CAD) with texture analysis in the differential of hepatic tumors on nonenhanced CT. MATERIALS AND METHODS: This study evaluated 164 liver lesions (80 malignant tumors and 84 hemangiomas). The suspicious tumor region in the digitized CT image was manually selected and extracted as a circular subimage. Proposed preprocessing adjustments for subimages were used to equalize the information needed for a differential diagnosis. The autocovariance texture features of subimage were extracted and a support vector machine classifier identified the tumor as benign or malignant. RESULTS: The accuracy of the proposed diagnosis system for classifying malignancies is 81.7%, the sensitivity is 75.0%, the specificity is 88.1%, the positive predictive value is 85.7%, and the negative predictive value is 78.7%. CONCLUSIONS: This system differentiates benign from malignant hepatic tumors with relative high accuracy and is therefore clinically useful to reduce patients needed for iodinated contrast agent injection in CT examination. Because the support vector machine is trainable, it could be further optimized if a larger set of tumor images is to be supplied.

Algorithms↗

Computerized scheme for automated detection of lung nodules in low-dose computed tomography images for lung cancer screening.

RATIONALE AND OBJECTIVES: A computerized scheme for automated detection of lung nodules in low-dose computed tomography images for lung cancer screening was developed. MATERIALS AND METHODS: Our scheme is based on a difference-image technique for enhancing the lung nodules and suppressing the majority of background normal structures. The difference image for each computed tomography image was obtained by subtracting the nodule-suppressed image processed with a ring average filter from the nodule-enhanced image with a matched filter. The initial nodule candidates were identified by applying a multiple-gray level thresholding technique to the difference image, where most nodules were well enhanced. A number of false-positives were removed first in entire lung regions and second in divided lung regions by use of the two rule-based schemes on the localized image features related to morphology and gray levels. Some of the remaining false-positives were eliminated by use of a multiple massive training artificial neural network trained for reduction of various types of false-positives. This computerized scheme was applied to a confirmed cancer database of 106 low-dose computed tomography scans with 109 cancer lesions for 73 patients obtained from a lung cancer screening program in Nagano, Japan. RESULTS: This computed-aided diagnosis scheme provided a sensitivity of 83% (91/109) for all cancers with 5.8 false-positives per scan, which included 84% (32/38) for missed cancers with 5.9 false-positives per scan. CONCLUSION: This computerized scheme may be useful for assisting radiologists in detecting lung cancers on low-dose computed tomography images for lung cancer screening.

False Positive Reactions↗

Magnetic resonance and computed tomography imaging in multiple myeloma.

This article reviews current knowledge on the various lesion patterns that can be observed at magnetic resonance (MR) imaging and on computed tomography images in patients with plasma cell neoplasms. It reviews limitations in specificity of imaging features and emphasizes difficulties in the recognition of the benign or malignant origin of vertebral fractures in these patients. The prognostic significance of MR imaging findings with respect to the natural history of the disease or to survival after treatment is discussed.

Bone Marrow↗