Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “biomaterial(s)”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

Biomaterial-neutrophil interactions: dysregulation of oxidative functions of fresh neutrophils induced by prior neutrophil-biomaterial interaction.

Biomaterial-associated infection results in increased morbidity and mortality, and may occur because of nonproductive premature activation of neutrophils resulting in impaired phagocyte function at the biomaterial surface in the event of bacterial challenge. To further explore the effects of this premature activation, we evaluated the supernatants of biomaterial associated neutrophils to determine whether soluble mediators were released, and the likely role of these mediators. We show that these supernatants contain a chemoattractant and thereby induce chemotaxis by fresh neutrophils. No evidence of enhanced oxidative free radical production by either unstimulated neutrophils or a primed response to other mediators occurs when neutrophils were incubated with these supernatants. We also examined the effect of adding fresh neutrophils to a biomaterial surface containing a previous inoculum of neutrophils, and observed that the fresh cells did not become stimulated to release reactive oxygen intermediates (ROI) and also exhibited impaired killing of staphylococci. These studies suggest that not only does the biomaterial surface activate the initial wave of neutrophils but that subsequent waves of neutrophils exhibit an impaired host-defense function. These results are consistent with the known impairment of host defense in the presence of biomaterials, and provide evidence for a long-term down-regulation of neutrophil function at biomaterial surfaces.

Biocompatible Materials↗

Opinions and trends in biomaterials education: report of a 2003 Society for Biomaterials survey.

The Society for Biomaterials (SFB) aims to serve its members through acting as a forum for the exchange of information and ideas. To aid in the practical development of the SFB and more specifically biomaterials education, all active, associate, and student members were surveyed. In general, the survey asked questions regarding respondent demographics, experiences and activities with the SFB, and opinions about biomaterials education. Perceptions and needs of biomaterials-related education and career-related training practices were a specific focus of the survey. A total of 140 individuals responded to the survey for a response rate of 18%. Members from industry felt that new hires, in general, should be better trained in product development, regulatory issues for new materials and devices, and in the relevant testing required. When asked what was missing from their professional education, many respondents commented that business training in areas such as negotiations, management, and understanding the needs outside of academia was lacking. Also, many respondents seemed to have trouble identifying with what they were supposed to know and felt a "lack of set professional knowledge." This study has raised many ideas and questions that require further discussion. The results should ultimately be useful for helping the SFB decide how best to focus future efforts in biomaterials education.

Biocompatible Materials↗

In vitro induction of a calcifying matrix by biomaterials constituted of collagen and/or hydroxyapatite: an ultrastructural comparison of three types of biomaterials.

The induction of a calcifying matrix was studied in vitro and compared for three biomaterials (collagen sponge, hydroxyapatite material and a mixture of both (Biostite)) cultured with human osteoblast-like cells. The influence of biomaterials on organic matrix synthesis and the calcification process was analysed at the ultrastructural level (transmission electron microscopy and X-ray microanalysis). Biomaterials were well tolerated by bone cells. Whichever biomaterial was used, osteoblasts proliferated and synthesized a new matrix constituted of fibrillar and non-fibrillar elements. This activity appeared earlier and was more intense with Biostite than with collagen sponge alone. A deposition of a mineral substance in this newly formed matrix was observed with the collagen sponge and Biostite, but never with hydroxyapatite alone. The mineral deposits were identified as hydroxyapatite crystals, similar to those observed and analysed in bone tissue. These in vitro observations clearly demonstrated the property of Biostite to produce a calcified collagenous matrix similar to bone tissue. However, in vivo confirmation is required before extending the use of this biomaterial to periodontology.

Biocompatible Materials↗

Cell-cycle control in cell-biomaterial interactions: expression of p53 and Ki67 in human umbilical vein endothelial cells in direct contact and extract testing of biomaterials.

Current biocompatibility testing involves the demonstration of cell proliferation, which is usually interpreted as a sign of positive biocompatibility when the materials sustain cell proliferation. As the field of biomaterials research is rapidly moving toward tissue-engineered devices and hybrid organs, control of cell function has become a main topic. Cell function, which involves specific differentiation pathways, cannot be separated from cell-cycle control. The study of cell-cycle control is an important extension of routine proliferation assays and has extensive roots in developmental and tumor biology. We studied the expression of the tumour suppressor gene p53 and the proliferation-associated antigen Ki67 of endothelial cells in response to biomaterial contact. Cells were seeded in six- or 24-well plates, in which one or three 12-mm-diameter biomaterial disks were laid down. After 48- and 72-h incubation periods, cells were processed for flow cytometry, immunofluorescence, or Western blotting. The following materials were used: titanium, NiCr alloy, and CoCr alloy. Cells were also exposed to 24-h (ISO-norm) extracts in 25-cm(2) culture flasks (600, 000 cells) for 24 and 48 h. For extract testing, serially diluted Ni-ion suspensions were also used. Human umbilical vein endothelial cells adhered to metal surfaces and started forming a monolayer within 3 days. Ki67 expression was positive in more than 60% after 2 days and decreased markedly after 3 days of adhesion. During this time cells developed focal contacts and produced a fibronectin matrix. p53 expression could be demonstrated with Western blotting and flow cytometry, but not with immunofluorescence. Differences due to both culturing time and material were found in expression patterns with both methods. Inverse correlations between Ki67 and p53 expression were detected, which are probably based on culture kinetics. The results indicate that expression of p53 and also Ki67 is clearly influenced by biomaterials in direct contact testing, despite the absence of obvious morphological differences. The p53 marker can be used for defining cell function in more detail, although the correlation with specific physiological function has still to be clarified.

Biocompatible Materials↗

Student Research Award in the Undergraduate Degree Candidate category, 30th Annual Meeting of the Society for Biomaterials, Memphis, Tennessee, April 27-30, 2005. Monocyte/lymphocyte interactions and the foreign body response: in vitro effects of biomaterial surface chemistry.

To determine the effect of biomaterial surface chemistry on leukocyte interaction and activity at the material/tissue interface, human peripheral blood monocytes and lymphocytes were cultured on a series of poly(ethylene terephthalate) (PET)-based biomaterials. Both monocytes and lymphocytes were isolated from whole human blood and separated by a nonadherent density centrifugation method before being plated on PET disks, surface modified by photograft copolymerization to yield hydrophobic, hydrophilic, anionic, and cationic surface properties. Monocytes and lymphocytes were cultured separately, to elicit baseline levels of activity, in direct coculture, to promote direct cell surface interactions, or in an indirect coculture system with both cell types separated by a -0.02-microm Transwell apparatus, to promote indirect paracrine interactions. Monocyte adhesion, macrophage fusion, and lymphocyte proliferation were measured on days 3, 7, 10, and 14 of culture. Results demonstrated that the presence of monocytes increased the activity of cocultured lymphocytes at the biomaterial/tissue interface, while the corresponding presence of lymphocytes increased the activation and fusion of indirectly cocultured monocytes. Biomaterial surface chemistry was also found to have a significant effect on monocyte adhesion and activation, and lymphocyte activity. Hydrophilic surfaces significantly inhibited both initial and longterm monocyte adhesion, and inhibited lymphocyte proliferation at longer time points. Anionic and cationic surfaces both exhibited mild inhibition of monocyte adhesion at prolonged time points and increased levels of macrophage fusion, while cationic surfaces decreased levels of lymphocyte proliferation and inhibited monocyte activity. These results elucidate the complex role of juxtacrine and paracrine interactions between monocytes and lymphocytes in the foreign body response, as well as promote the consideration of hydrophilic surfaces in future designs of implantable biomedical devices and prostheses.

Biocompatible Materials↗

Mechanisms of the removal of hexavalent chromium by biomaterials or biomaterial-based activated carbons.

Three papers published during recent 2 years in Journal of Hazardous Materials made a mistake in analyzing chromium species in aqueous solution, resulting in incorrect elucidation of Cr(VI) biosorption; the Cr(VI) was removed from aqueous solution systems by 'anionic adsorption'. However, it has been proved that Cr(VI) is easily reduced to Cr(III) by contact with organic materials under acidic conditions because of its high redox potential value (above +1.3 V at standard condition). Therefore, it is strongly possible that the mechanism of Cr(VI) removal by biomaterials or biomaterial-based activated carbons is not "anionic adsorption" but "adsorption-coupled reduction". Thus, for researches of Cr(VI) biosorption, researchers have to analyze not only Cr(VI) but also total Cr in aqueous solution and to check the oxidation state of chromium bound on the biomaterials or activated carbons.

Biocompatible Materials↗

New ideas in biomaterials science--a path to engineered biomaterials.

Our existing biomaterials, although demonstrating generally satisfactory clinical performance, were developed based upon a trial-and-error optimization approach rather than being engineered to produce the desired interfacial reaction. Most biomaterials exhibit a nonspecific biological reaction, with sluggish kinetics and a broad spectrum of active processes simultaneously occurring. This article describes materials science nanotechnology, and molecular biology techniques that may permit the synthesis of precisely engineered surfaces. Such surfaces might demonstrate rapid, precise reactions with proteins and cells. This opens the question, "what type of specific surface bioreactions do we want?" New thoughts on biocompatibility are presented that may be helpful in the design of specific surfaces yielding precise, defined biological responses.

Biocompatible Materials↗

Recent results on functional polymers and macromonomers of interest as biomaterials or for biomaterial modification.

Different families of functionalized polymers with potential as biomaterials, or for biomaterial modification, have been investigated. In particular, degradation studies have been performed on poly(amidoamines), a family of polymers obtained by polyaddition of amines to bisacrylamides, and endowed with heparin-complexing ability. Some new poly(amidoamines) with more resistance towards hydrolytic degradation than traditional ones have been discovered. Other ter-amino polymers deriving from the polyaddition of ter-amino functionalized bis-thiols to bis-acrylic esters, or other activated unsaturated compounds, have been studied. Their quaternarization products have been proven, in a parallel work, to act as powerful antimicrobial agents. By performing in situ the polyaddition reaction, semi-interpenetrated networks based on silicone rubber and the same polymers have been prepared. Finally, end-functionalized amphiphilic oligomers have been prepared by radical polymerization techniques, and their use for enzyme modification considered.

Biocompatible Materials↗

[The toxicologic evaluation of biomaterials. 1. Results of biomaterial tests in cultures of human amnion epithelial cells and human fibroblasts].

Cell cultures are a highly sensitive toxicological model used also for the testing of biomaterials. Beside the safety tests provided in the Pharmacopoeia of GDR cultures from human amnionepithelial cells and fibroblasts are used. The paper reports the results of some methodical investigations concerning the procedure of extraction of biomaterials, the evaluation of test results and the comparison with the results of other biological tests.

Amnion↗

Reactivity of blood with biomaterials in vitro: evaluation of some in vitro test systems for estimation of the blood compatibility of biomaterials.

Several different in vitro tests designed to estimate the degree of compatibility of blood with biomaterials have been examined to determine possible effects of donor or donor-material interaction. Statistical evaluation of data was performed, and adequate data were collected with each different test system to render such evaluation meaningful. Isolated examples of donor and donor-material interaction were detected, but these proved to be minor or insignificant in each case. Data are presented for each of the in vitro test systems examined to indicate the number of replicate determinations required for observed differences to be significant at the 5% level.

Biocompatible Materials↗

[Microrough surface and its bio-effects of metallic biomaterials (II)--bio-effects of microrough surface of metallic biomaterials].

As for bio-effect of microrough surface of metallic biomaterials, seven aspects are reviewed in this article: i.e., the relationship between microrough surface (MRS) and corrosion resistance, ion release rate; the relationship between MRS and inflammation; the relationship between MRS and epithelium cells, fibroblast cells; the relationship between MRS and soft tissue; the relationship between MRS and bone; the relationship between MRS and blood tissue; the relationship between MRS and microorganism, contamination, decontamination. To sum up, MRS has its advantages in biocompatibility.

Biocompatible Materials↗

Vitamin E as an antioxidant for poly(etherurethane urea): in vivo studies. Student Research Award in the Doctoral Degree Candidate Category, Fifth World Biomaterials Congress (22nd Annual Meeting of the Society for Biomaterials), Toronto, Canada, May 29-June 2, 1996.

Poly(etherurethane) elastomers are useful materials in medical devices because of their mechanical properties and biocompatibility. However, it is necessary to stabilize these elastomers against the oxidation of their ether soft segments. Synthetic antioxidants such as Santowhite and Irganox are often satisfactory; however, particularly for biomedical applications, it was of interest to test the natural antioxidant vitamin E in poly(etherurethane urea) (PEUU) elastomers in vivo. The alpha-tocopherol form of vitamin E was added to PEUU at 5% by weight. Biaxially strained PEUU specimens with and without vitamin E were tested in vivo in the cage implant system. The influence of vitamin E on PEUU biostability was analyzed by attenuated total reflectance-Fourier transform infrared (ATR-FTIR) spectroscopy and scanning electron microscopic (SEM) characterization of the PEUU surface. ATR-FTIR results showed that vitamin E prevented chemical degradation of the PEUU surface up to 5 weeks implantation, and at 10 weeks 82% of the ether remained. In contrast, without an antioxidant, only 18% of the ether remained after 10 weeks. No surface pitting or cracking was observed by SEM on PEUU with vitamin E; PEUU without antioxidant ruptured owing to extensive pitting and cracking. It was concluded that the antioxidant properties of vitamin E prevented oxidation of strained PEUU elastomers in vivo. The influence of vitamin E on PEUU biocompatibility was characterized by exudate leukocyte counts, density of leukocytes adherent to the PEUU, and morphology of adherent leukocytes. These results indicated decreased leukocyte counts in the exudate and less active adherent cells on the PEUU with vitamin E compared to PEUU without antioxidant. A proposed cell-polymer feedback system demonstrates how vitamin E improves both biostability and biocompatibility of PEUU elastomers in vivo.

Animals↗

Founder's Award, Society for Biomaterials. Sixth World Biomaterials Congress 2000, Kamuela, HI,May 15-20, 2000. Really smart bioconjugates of smart polymers and receptor proteins.

Over the past 18 years we have been deeply involved with the synthesis and applications of stimuli-responsive polymer systems, especially polymer-biomolecule conjugates. This article summarizes our work with one of these conjugate systems, specifically polymer-protein conjugates. We include conjugates prepared by random polymer conjugation to lysine amino groups, and also those prepared by site-specific conjugation of the polymer to specific amino acid sites that are genetically engineered into the known amino acid sequence of the protein. We describe the preparation and properties of thermally sensitive random conjugates to enzymes and several affinity recognition proteins. We have also prepared site-specific conjugates to streptavidin with temperature-sensitive polymers, pH-sensitive polymers, and light-sensitive polymers. The preparation of these conjugates and their many fascinating applications are reviewed in this article.

Acrylamides↗

Influence of the substrate binding characteristics of fibronectin on corneal epithelial cell outgrowth. Student Research Award in the Doctoral Degree Candidate Category, Fourth World Biomaterials Congress (18th annual meeting of the Society for Biomaterials), Berlin, Germany, April 24-28, 1992.

The outgrowth of corneal epithelial cells onto a polymeric substrate is expected to be the primary event in the epithelialization of a synthetic corneal graft. Circular corneal buttons (5 mm) were punched from excised rabbit corneas and placed onto bare substrates or substrates preadsorbed with fibronectin (fn), albumin, or binary mixtures of both fn and albumin. Cell outgrowth areas were measured after culturing the buttons for 4 days in serum-free medium. Fibronectin adsorption to the materials was measured from pure and binary solutions with 125I-radiolabeled fibronectin. A parameter thought to be related to the binding strength of fn to polymeric substrates was measured in parallel experiments by partial elution of the adsorbed fn by 3% sodium dodecyl sulfate (SDS). Following pure solution fibronectin adsorption a range of outgrowth areas was measured (from 0.86 +/- 0.03 cm2 for glass to 1.49 +/- 0.03 cm2 for TCPS). On all of the materials tested cell outgrowth areas increased following fn preadsorption and decreased following albumin preadsorption relative to bare surfaces (p less than 0.05). Following preadsorption with binary protein mixtures cell outgrowth areas increased with fibronectin adsorption, however, the outgrowth areas were not determined solely by the concentration of fn adsorbed onto the surfaces. This result suggested that the biological efficiency of the adsorbed fibronectin was substrate-dependent. When the cell outgrowth data were cross-plotted against fn retention following SDS elution, the outgrowth areas were found to increase along with increases in fn retention. Based on these data we suggest that epithelial cell outgrowth may be partially governed by the tightness of binding between the fn molecules and the underlying substrate.

Adsorption↗